G R AV I T Y M E T E R

Similar documents
Vibration Isolation in Data Centers

Building a simple seismometer

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Active noise control in practice: transformer station

Bandwidth-dependent transformation of noise data from frequency into time domain and vice versa

Everything you need for protection scheme testing

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Data in seismology: networks, instruments, current problems

Freezers - Ultrafreezers. Platilab & Irilab Series

READING DEVICE US-05

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Calibrating Differential Pressure Sensors

PowerGem Pro Uninterruptible Power Supply

USER MANUAL V5.0 ST100

Sound Level Meters Nor131 & Nor132

MATRIX borehole logging system

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

How to measure absolute pressure using piezoresistive sensing elements

Micro Motion 3098 Gas Specific Gravity Meter

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

CW46S GPS Sensor P R O D U C T B R I E F. Description. Features. Applications. Block Diagram

Woods Hole Group, Inc. Oceanography and Measurement Systems Division INTEGRATED REAL-TIME MONITORING SYSTEM

Leica WDM65 Waveform Digitizer Module Product Specifications

Practice Test SHM with Answers

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

CHARACTERISTICS OF DEEP GPS SIGNAL FADING DUE TO IONOSPHERIC SCINTILLATION FOR AVIATION RECEIVER DESIGN

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Moultrie Group Subsurface Geophysical Surveys

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Proximity Transmitters and Seismic Vibration Transmitters

Environment-Laboratory Ambient Conditions

INTREPID Perimeter Intrusion Detection System

Dash 18X / Dash 18 Data Acquisition Recorder

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Perimeter Security System

The Fundamentals of Spring Testing

VE464 ASSURING HIGH PRODUCTIVITY AND QUALITY FOR VIBROSEIS OPERATIONS. Ahead of the Curve SM

Three Methods for Calculating the Buoyant Force Gleue: Physics

Vehicle GPS Tracker GP268. GP268 Vehicle GPS/GPRS Tracking and Monitoring System Presentation July, 2009

PD Monitor GIS. 24/7 Partial Discharge (PD) monitoring system for Gas Insulated Switchgear. Benefits NEW PRODUCT

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

AS COMPETITION PAPER 2008

EDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

DC Electronic Loads 8500 series

SEISMIC MONITORING & PROTECTION SYSTEMS

SUNON SPECIFICATION FOR APPROVAL

Phase Modular Finally the benefits of Modular ups are for all

THE STRUCTURAL HEALTH MONITORING SYSTEM OF THE RION ANTIRION BRIDGE CHARILAOS TRIKOUPIS. Akis Panagis

State Newton's second law of motion for a particle, defining carefully each term used.

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Cell Phone Vibration Experiment

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Rackmount Intelligent Pressure Scanners

Voltech DC1000. Precision DC Bias Current Source

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

LOXONE 12 Channel Amplifier

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

State Newton's second law of motion for a particle, defining carefully each term used.

Hand-held thermometer Model CTH7000


LLRF. Digital RF Stabilization System

DCS Series 1 kw, 1.2 kw, & 3 kw

PHYSICAL QUANTITIES AND UNITS

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Online UPS. PowerWalker VFI 1000R/1U

Incubator with mechanical convection

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

How To Make A Fronius Cl Power Inverter

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

K-Type Thermocouple Sensor User s Guide

The Sonometer The Resonant String and Timbre Change after plucking

Frequency selective monitoring and logging of environmental electromagnetic fields

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

COMBIMASS. Technical Data COMBIMASS eco-bio +

Practice final for Basic Physics spring 2005 answers on the last page Name: Date:

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Cisco Nexus 7000 Series Power Supply Modules

IFC 070 Technical Datasheet

Automatic AES Change-Over

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Examination Space Missions and Applications I (AE2103) Faculty of Aerospace Engineering Delft University of Technology SAMPLE EXAM

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Research RF Sputtering Packages

BIOMEDICAL REFRIGERATORS

Transcription:

GRAVITY METER

Micro-g LaCoste is proud to introduce the gphonex gravity meter as the latest member of its land gravity meters. The gphonex gravity meter is based upon the LaCoste and Romberg technology that has dominated land gravity meters since 1939. The gphonex gravity meter has a low drift so that it can be used to integrate periodic signals (like earth tides) for very long time periods (years). The gphonex also has excellent high frequency response so they can be used to monitor higher frequency non-periodic events such as earthquakes. The gphonex can be coarse-ranged over 7000 milligal (worldwide, and has a 100 milligal dynamic range during measurement. The versatile gphonex gravity meter has a sophisticated data acquisition system synchronized by a rubidium clock that can be locked to GPS so that arrays of gphonexs can be used to give a wider area picture of seismic or long period gravity changes due to subsurface density changes. The instrument can be monitored and controlled via the internet for remote operation. The principal behind the Micro-g LaCoste s gphonex is the patented L&R zero-length spring suspension system. The gphonex is based upon the G-Meter, but with significant upgrades: It has an improved thermal system, a double-oven, for more precise temperature stability. It has a true vacuum seal so that it is completely insensitive to buoyancy changes due to atmospheric changes. The complete Micro-g LaCoste gphonex System is a light weight, compact system with a total weight including carrying case of 58 kg. WWW.MICROGLACOSTE.COM

INSTRUMENT FEATURES Zero Length Spring Tension system ensuring world-wide gravity range. Sensor housed in an insulated double-oven ensuring accurate temperature control. Pressure and temperature are continuously monitored and can be used to correct gravity data in real time. Gravity and Level signals digitized by accurate 24 A/D converters and stable voltage references. Synchronizes GPS time with extremely accurate Rubidium timing. Uninterruptible Power Supply (UPS) insulates the system from power fluctuations. Three sealed chambers isolate the sensor from humidity and pressure changes. A built-in internet webserver allows the gphonex data logging screen to be accessed in real-time from the internet and permits authorized users to download data remotely. gphonex APPLICATIONS Volcanic Monitoring Earth Tides Ground Water Monitoring Earthquake Monitoring Ocean Loading Studies gmonitor SOFTWARE SCREENSHOT gmonitor main screen Upper Left: Setup parameters Lower Left: Integrated acceleration provides velocity and position Upper Right: Raw Acceleration Lower Right: Measured earth tide (red line) compared with modeled earthtide (blue line)

gphone Data Example 2007 KIRIL ISLANDS EARTHQUAKE The January 13, 2007 earthquake (M8.2) off the coast of the Kiril Islands was detected by the gphone gravity meter at the Micro-g LaCoste facility in Colorado. These data demonstrate that gphones are capable of recording extremely precise vertical acceleration, velocity, and displacement during quiet periods as well as during period of high seismic activity. Kiril Islands earthquake recorded in Lafayette, CO USA. Displacement due to P, S, and Rayleigh waves recorded with gphone (data sampled at 1s). The above graph displays repeat wave arrivals as detected by the gphone. These Rayleigh waves traveled around the globe eleven times after the earthquake.

PERFORMANCE SPECIFICATIONS RESOLUTION 0.1 µgal PRECISION 1 µgal SYSTEM NOISE 0.1 to 0.3 µgal/ Hz RANGE FEEDBACK RANGE (DURING MEASUREMENT) INSTRUMENT DRIFT 7000 milligal uncalibrated (worldwide) +/- 100 milligal 1.5 milligal/month, typically < 500 µgal/month POWER SPECTRA COMPARISON Shown above is a typical power spectrum for a gphonex running in our factory test room. Note that the noise level is between 0.1 and 0.3 µgal / (Hz) at 0.01 Hz. WWW.MICROGLACOSTE.COM

SYSTEM POWER INPUT TO UPS SYSTEM (Must be selected at purchase time) TOTAL SYSTEM POWER (25 C) UPS UPTIME IN POWER OUTAGE Conditions: UPS fully charged prior to blackout Load on UPS is timing box and meter only Ambient temperature 27 C Meter temperature is at steady state at time of the blackout 110 or 220 VAC Steady State Load: 100 Watts Maximum Load: 330 Watts 4 hours WEIGHT & DIMENSIONS COMPONENT WEIGHT DIMENSION METER HOUSING 13kg 31 x 32.5 x 25.2 cm (meter leg height 9 cm) ELECTRONICS BOX 30kg 42.5 x 51 x 20.5 cm LAPTOP COMPUTER 3kg 26.5 x 32.5 x 4 cm CARRYING CASE 12kg 48.8 x 51.2 x 48 cm TOTAL 58kg 1401 Horizon Ave. Lafayette, CO 80026 USA PHONE (303) 828-3499 FAX (303) 828-3288 EMAIL info@microglacoste.com WWW.MICROGLACOSTE.COM