User s Manual Before using the inverter, you need to read and save the safety instructions.



Similar documents
User s Manual Before using the inverter, you need to read and save the safety instructions.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

VLT Series 300 Watt True Sine Wave Inverter

Online UPS. PowerWalker VFI 1000R/1U

3000W Power Inverter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

Battery Power Inverters

User Manual 1K/2K/3K Online UPS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

YSmart Technology Co.,Ltd

Installation and Operation Guide for PD4000 Series Power Control Center

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

BB800 Off-Grid Solar System

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

TIG INVERTER INSTRUCTION MANUAL

Installation and Operation Guide for PD4100 Series Power Control Centers

TruPower-Portable-500W. Solar Starter kit

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

12 Volt 30 Amp Digital Solar Charge Controller

Manual Ranging MultiMeter

USER MANUAL Online UPS 1K/2K/3K Rack

12-Volt 10-Amp Regulated Power Supply

USER MANUAL Online UPS 1K/2K/3K

10000HXL31/15000HXL31/20000HXL31

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User Manual HomeGrid 3000 Solar Generator

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

E Manual N Phoenix

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Manual. Solar Fountain Mobile Phone Charger

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

MAJORSINE Power Inverter

AutoRanging Digital MultiMeter

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

User Manual for CH-PFC76810

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

MCR1900 Media Converter 19-Slot Chassis

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

How To Use A Cdm250 Digital Multimeter

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

ADM1TE 5/30A DIN rail single phase two wire energy meter

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Photovoltaic Solar Energy Unit EESFB

BITMAIN. APW PSU Series User Guide

ST Series POWER SUPPLIES USER INSTRUCTIONS

Uninterruptible Power Supply

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Back-UPS Pro 1300/1500 Installation and Operation

INV Series Sine-Wave Inverter. Manual INV12/220-XXXX KLC INV24/220-XXXX KLC INV48/220-XXXX KLC INV110/220-XXXX KLC INV220/220-XXXX KLC

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Advantium 2 Plus Alarm

750 WATT Power Inverter

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ELECTRIC BICYCLE USER MANUAL

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

350, 500, 650 and 1000 MODELS

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Model UT33A: OPERATING MANUAL Table of Contents (1)

COLOR VIDEO DOOR PHONE CDV-71BE/D

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

USER MANUAL Online UPS 6K/10K RACK

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

Manual for Fire Suppression & Methane Detection System

Instructions & Safety Information Models A220-20D and A220-20L Version 2

650W Single Output Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply

Home Solar Kit Owner s Manual. Model: HS

Charge Regulator SCR 12 Marine

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Installation and Operation Back-UPS 1250, 1300, 1500

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

S10I / S20I / S30I Solar Light Controller USER MANNUAL

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

GRID TIE INVERTER MANUAL GRID TIE INVERTER SWEA EUROPE FRIENDLY CARE FOR YOUR EXPENSES AND OUR ENVIRONMENT!

POWER TO GET THE JOB DONE

Installation and Operating Instructions (for chargers shown below)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

XPower 1500 Portable Household Power

Transcription:

User s Manual Before using the inverter, you need to read and save the safety instructions.

SHI SERIES (SHI400, SHI600, SHI1000) Pure Sine Wave Inverter The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.

CONTENTS 1. Introduction... 1 2. Important Safety Instructions... 2 3. Inverter Operation... 4 4. Functions... 5 5. Troubleshooting... 12 6. Maintenance and Warranty... 14 7. Technical Specification... 15

1. Introduction Thanks for purchasing SHI series inverters. The product is a pure sine wave inverter which can convert 12/24/48Vdc to 220/230Vac 50/60Hz based on full digital and intelligent design. It features high reliability, high efficiency, concise outline, small volume, full protection functions, easy installation and operation. The inverter can be applied in many fields, such as household appliances, electric tools and industrial devices etc, especially for solar photovoltaic power system. Features: Complete isolation-type inverter technology. Adoption of advanced SPWM technology, pure sine wave output. Dynamic current loop control technology to ensure inverter reliable operation. Wide DC input voltage range. Low output harmonic distortion(thd 3%). LED indicators for input voltage range, load power range, normal output & failure state. Optional energy saving mode. The output voltage and frequency can be switched. Extensive protections: short-circuit, overload, under/over input voltage, over-temperature, and inverter s inner fault identification protections. Wide working temperature range (industrial level). Continuous operation at full power. 1

2. Important Safety Instructions As an AC power supply equipment, the inverter s output voltage is with the same level as that of household power plug. Mind the AC output terminals, or you may get an electric shock and result in life danger! Attentions: Connect the DC input according to the requirement strictly. The power inverter has a relatively wide input range, but too high or too low input may cause problems even destroy the inverter. The surge input voltage can t exceed 20V for the 12V inverters, 40V for 24V inverters, 80V for 48V inverters, or the inverters will be damaged. A reverse polarity connection will blow the fuses in the inverter and may damage the unit. Do not expose the inverter to humid, flammable, explosive or dust environment. Keep the inverter out of children touch. Inverter input is recommended to connect to battery, the min. capacity of battery(expressed in AH) should be calculated in the following way: 5times of the rated power of the inverter/battery voltage. If for testing purpose, user should select DC power supply current at least twice greater than that of the inverter rated input to keep inverter normal operation. Use DC power supply for testing may cause the damage of the inverter. When the inverter works continuously, its surface may became very hot, please make sure the air ventilation clearance around the inverter is more than 10cm. Keep away from the material or device which may suffer from high temperature when the inverter is working. Do not install the inverter in airproof location and keep enough space 2

around the inverter. The protective grounding must be connected to the ground. The cross section of wire should not be less than 4mm 2. A fuse or breaker should be used between battery and inverter, the value of fuse or switch should be twice of the inverter rated input current. The wire connects between battery and inverter should be shorter than 3m, the current density should be less than 3.5A/mm 2 while the output of inverter is fully loaded. If the wire longer than 3m, the current density should be reduced. Do not connect the battery charger or similar devices to the input terminal of the inverter. Do not put the inverter close to the flooded lead-acid battery because the sparkle in the terminals may ignite the hydrogen released by the battery. It s an off-grid inverter, if connect to the grid, the inverter may be damaged. This inverter can only be used singly, parallel connection or in series will damage the inverters. Do not attempt to repair the fault inverter yourself, otherwise it may lead to a serious accident. Please contact the manufacture s engineer. 3

3. Inverter Operation Connect the input and output terminals accurately. Turn on the power using the ON / OFF switch on the front panel. In order to avoid the protections resulted from the surge power, please turn on AC loads one by one after the output of the inverter is normal. Please check it as below: Set the power switch to the OFF position. Insert the load s plug into the inverter s output outlet. Connect the protective grounding to the ground. Make sure the fuse or breaker use between battery and inverter is off. Connect the battery ( + terminal with red line, - with black line). Do not connect them by contraries, or the power inverter will be damaged. Switch on the fuse or breaker. Switch the inverter to ON and then turn on the loads one by one. Check the operation state of both power inverter and loads. Green of the failure LED indicator means the state is normal. If there are different loads, it is suggested that turn on the load with large startup current first, such as television, then turn on the load such as lamp when the inverter works stable. If the failure LED indicator is Red and the buzzer alarms or no output when you turn on devices, switch off the loads and power inverter immediately. Check the system by referring to the troubleshooting guide. Turn on the devices again according to the operation methods after the failure is removed. 4

4. Functions DC Input Panel DC Input Terminal Negative DC Input Terminal Positive Protective Grounding Fan Ventilatio n AC Output Panel Load Level Indicator Input Level Indicator Fault Indicator AC Outlet RS485 Port Mode Switch ON/OFF Switch Switch Node 5

The Optional Outlet Australia/New Zealand European 6

Input Level: Display Input Voltages LED Status 12V 24V 48V RED Slow Blink <10.5 <21 <42 RED 10.5~11 21~22 42~44 ORANGE 11~12 22~24 44~48 GREEN 12~14.5 24~29 48~58 ORANGE Fast Blink 14.5~16 29~32 58~64 RED Fast Blink >16 >32 >64 Load Level: Display AC Loads LED Status AC Load ORANGE <20% GREEN 20%~75% RED >75% RED Slow Blink Overload RED Fast Blink Short Circuit Output & Fault Status LED Status GREEN RED Fast Blink RED Slow Blink ORANGE Fast Blink ORANGE OR RED OFF Status Output Normal Overload or Short circuit, No Output Over or Low input voltage, No Output Over temperature, No Output Inverter Fault, No Output Saving mode, Power Off,No Output 7

Alarms Alarms Buzzer Sounds Status Overload or Short circuit, No Output Over or Low input voltage, No Output Over temperature, No Output Inverter Fault, No Output The buzzer stops after 20S. 8

Protections Overload or Output Short Circuit Protection Overload 125% 150% 200% 230% >250% Character Continuance 60S 10S 1.5S <0.2S <0.01S Space 5 seconds for the first time, 10 seconds for Recover 3 times the second time, and 15 seconds for the third time If the overload or short circuit status still remains when the inverter tries to recover for 3 times, you should reduce or clear the loads and then restart the inverter manually. Load over than 250% will be treated as output short circuit. Input Low Voltage Protection The output is switched off when the input voltage is lower than low voltage protect value, and auto-switched on when the input voltage reach low voltage recover value. User can also manually restart the inverter to switch on output by the ON/OFF switch, when the input voltage is higher than low voltage protect value. 12V 24V 48V Low Voltage Protect Value 10.8 21.6 43.2 Low Voltage Recover Value 12.5 25 50 Input Over Voltage Protection The output is switched off when the input voltage is higher than over 9

voltage shut off value, also the output is auto-switched on when the input voltage drops below over voltage recover value. 12V 24V 48V Over Voltage Shut Off Value 16 32 64 Over Voltage Recover Value 14.5 29 58 Fault Protection The inverter will shut down when the output voltage is error or when the inverter has inner fault. Over Temperature Protection The inverter will shut off when the internal temperature is overheating. And it automatic restarts when the temperature recovers to the normal level. Others Saving Mode When the switch is on Saving side, the inverter will enter into the Saving Mode. It will shut off the output if the loads value is less than 20VA. Then restart and detect the power of the load again after 10s. If the load is more than 20VA, the inverter will turn on the output.otherwise it will shut off output again. It cycles like this. So please don t use the saving mode if the load is smaller than 20VA. 10

Mode Switch The output mode can be changed by the mode switch. When the switch No.1 is on the ON side, the inverter will enter into the saving Mode. This mode can be switched online. When the switch No.2 is on the ON side, the output frequency is 60Hz,otherwise is 50Hz. When the switch No.3 is on the ON side, the output voltage is 230Vac, otherwise is 220Vac. Both the output frequency and the output voltage change availability after restart the inverter. Switch Node The inverter can be control by the other equipment through the switch node. When the switch node is link, it equal to ON/OFF switch is on. The connection between the switch node and the ON/OFF switch as follow diagram: ON/OFF Switch POS(+) NEG(-) If need to use the switch node, a relay should be used. The rating current of the relay should not be less than 5A. The cross section of wire needs 1mm 2. 11

5. Troubleshooting WARNING: High voltage is inside the inverter, do not open or disassemble it! Attempting to service the unit yourself may cause the risk of electrical shock or fire! Problem Possible Cause Solution Input LED blink, Input voltage is Measure the input voltage. fault red LED slow too high or too low The inverter recovers when blink the input becomes normal. Load LED blink, Overload or load Check out if the AC load is fault red LED fast short within the rated power or blink whether there is load short. Fault orange LED Over temperature Improve the quality of fast blink inside the inverter ventilation and do not block the vent. Restart the inverter when it is cool down. Fault red LED Inverter abnormal Remove all the connected plugs then restart. If inverter works well, please check the load and line. If the LED keeps red, the inverter has inside faults and should be returned to the factory. 12

Fault orange LED Inverter abnormal Made sure the DC input terminals is tight, the input voltage between 10.8V and 15V (21.6~30V for 24V, 43.2~60V for 48V product) and restart the inverter. If the LED keeps orange the inverter has inside faults and should be returned to the factory. 13

6. Maintenance and Warranty The casing of the inverters may be cleaned regularly with a damp cloth (not wet) to prevent accumulation of dust and dirt. The screws on the DC input terminals must be tightened. The warranty period of the inverter is 2 year since the date of original shipping. Within the period, we will repair the product or replace the defective product for free. Return the defective with shipping cost prepaid. And provide proof of purchasing date. We will pay the return shipping charges within warranty period. The warranty doesn t apply under the following conditions: 1. Damaged by accident, negligence, abuse, improper use 2. Input voltage exceed the nominal input voltage of inverter 3. Unauthorized modification or attempted repair 14

7. Technical Specification Technical Data Types SHI400-12 SHI400-22 Nominal Battery Voltage 12V 24V Input Voltage Range 10.8 ~16Vdc 21.6 ~32Vdc No Load Current 0.8A 0.45A Output Wave Pure Sine Wave Output Voltage 220Vac±3% / 230Vac±10% Continuous Power 400W Power 10 sec 600W Power 1.5 sec 800W Surge Power 900W Frequency 50/60Hz±0.2% Distortion THD 3%( resistive load) Efficiency at Rated Power 91% 92% Max. Efficiency 92% 93% Terminal 16mm 2 Dimensions 280 166 74.3mm Installation 150 158mm Hole Size Φ5mm Net Weight 1.8kg 15

Types SHI600-12 SHI600-22 Nominal Battery Voltage 12V 24V Input Voltage Range 10.8 ~16Vdc 21.6 ~32Vdc No Load Current 0.7A 0.45A Output Wave Output Voltage Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency Distortion THD Efficiency at Rated Power Pure Sine Wave 220Vac±3% / 230Vac±10% 600W 900W 1200W 1350W 50/60Hz±0.2% 3%( resistive load) 91% 92% Max. Efficiency 93% 94% Terminal 25mm 2 Dimensions Installation Hole Size Net Weight 295 186 82mm 150 178mm Φ6mm 2.3kg 16

Types SHI1000-22 SHI1000-42 Nominal Battery Voltage 24V 48V Input Voltage Range 21.6 ~32Vdc 43.2 ~64Vdc No Load Current 0.45A 0.35A Output Wave Output Voltage Continuous Power Power 10 sec Power 1.5 sec Surge Power Frequency Pure Sine Wave 220Vac±3% / 230Vac±10% 1000W 1500W 2000W 2250W 50/60Hz±0.2% Distortion THD 3%( resistive load) Efficiency at Rated Power 93% 93.5% Max. Efficiency 94% 94% Terminal 25mm 2 Dimensions Installation Hole Size Net Weight 295 208 98mm 150 200mm Φ6mm 3.3kg 17

Environmental Parameters Working Temperature -20 ~+50 Storage Temperature -35 ~ +70 Humidity Altitude < 95%(N.C.) < 5000 m (Derating to operate according to IEC62040 at a height exceeding 1000 m) Others Insulation Resistance Dielectric Strength Between DC input terminals and metal case: 550MΩ; Between AC output terminals and metal case: 550MΩ. Between DC input terminals and metal case: Test voltage AC1500V, 1 minute Between AC output terminals and metal case: Test voltage AC1500V, 1 minute Version No. : V1.0 18

BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: +86-10-82894112 / 82894962 Fax: +86-10-82894882 E-mail: info@epsolarpv.com Website: http://www.epsolarpv.com/