AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Similar documents
PARTICLE GENERATOR MODEL 8026

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

GENERAL PURPOSE THERMAL MASS FLOWMETER MODEL 4140/4143

General Purpose Thermal Mass Flowmeter Model 4140/4143

i410/i1010 AC/DC Current Clamp

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Data Analysis Software

3 WATT LED SPOTLIGHT Model No. SLM

Alarm Clock USER GUIDE

Limited Warranty Letter for BYD Photovoltaic Module

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

24.2L M.A.N. V12 Engine Module

Mold Alert... Operation Manual P0270

Value Extended Warranty and Premium Extended Warranty. Terms and Conditions

Thermocouple Thermometer Models

ExStik TM ph Waterproof Meters

el-720 Carbon Dioxide Gas Leak Detector User s Guide

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

RT-200 HI-TEST ROPE TESTER

62 Max/62 Max + Infrared Thermometer

Installation Instructions

Dolphin 9900 Mobile Computers

How To Control A Pressura Room Pressure Monitor

How To Use The Visifault Visual Fault Locator

TERMS AND CONDITIONS

PRESSURA CLEAN ROOM PRESSURE MONITOR/CONTROLLER W/LON/BACNET

Residential Standby Extended Warranty Statements

LIMITED WARRANTY. (i) repair the defective portion of the BlackBerry Device without charge to YOU with new or reconditioned parts;

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

Model SRMD Setra Remote Monitoring Display

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Thermistor Thermometer MODEL NO

NFC Communication Tray Model: HHX-IT3-Z

Triton Systems of Delaware, LLC. Warranty Statement

Alarm Clock USER GUIDE

TERMS AND CONDITIONS 1 CONTRACT INFORMATION

LCD5500Z / PKP-LCD v3.x Installation Instructions

User and Installation Guide

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

900 MHz Lightweight Wireless Stereo Headphones

Transource Warranty & Support Agreement

Mini Power Bank and Charger

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

User Manual (English)

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Sip/Puff Switch User Guide

Dual Laser InfraRed (IR) Thermometer with Color Alert

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Mini-led spotlight with magnetic base

1. INTERPRETATIONS AND DEFINITIONS Whenever used in this Agreement, the following terms shall have the meaning set out below:

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Owner s Manual & Safety Instructions

Instructions & Safety Information Models A220-20D and A220-20L Version 2

ATS Overhead Table Shelf System INSTRUCTION MANUAL

81000 Series Aluminum Gate Valve Installation and Repair Manual

Panini Maintenance Program My Vision X STANDARD WARRANTY-

INSTRUCTION MANUAL DTH Fax: (503)

XP Series Balances Operation Manual

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

HotLok Pass Through Blanking Panel

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Wolverine Data PASS Portable Scanner User Manual V1.0

Seven function digital multimeter

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Installation Guide Smart-UPS X External Battery Pack SMX120BP

BroadBand PowerShield. User Manual

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Dual Laser InfraRed (IR) Thermometer

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer


Vibrating Alarm Clock VAC500

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

IR Repeater. Operation Manual P8620

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006


K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Atomic Alarm Clock model 13131W2

Owner s manual. Free 5 year parts, 1 year labour gurantee Register your guarantee at

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

EzFlex Combustible Gas Leak Detector Model EZ40

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

ELECTRIC FENCE ENERGISER

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

TC Electronic Extended Warranty Policy

323/324/325. Calibration Manual. Clamp Meter

General Terms and Conditions for Online Sales of TomTom Inc ( TomTom )

Laptop Power Adapter for home/office User Manual

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Quick Installation Guide TK-209K TK-409K

Section 1: Introduction Section 2: igolf Neo Section 3: igolf Neo Sync Section 4: Appendices... 26

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Transcription:

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410 OPERATION AND SERVICE MANUAL P/N 1980575, REV E SEPTEMBER 2014

Copyright TSI Incorporated / 2007-2014 / All rights reserved. Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA Fax No. (651) 490-3824 Limitation Of Warranty And Liability (effective April 2014) (For country-specific terms and conditions outside of the USA, please visit www.tsi.com.) Seller warrants the goods, excluding software, sold hereunder, under normal use and service as described in the operator's manual, to be free from defects in workmanship and material for 24 months, or if less, the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions and exceptions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment; b. Pumps are warranted for hours of operation as set forth in product or operator s manuals; c. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment; d. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies; e. This warranty does not cover calibration requirements, and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty; f. This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning; g. This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual.unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER S OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR i

REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS, BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call Customer Service department at +44 (0) 149 4 459200 (UK), (800) 874-2811 (USA), or (1) 651-490-2811 (International). ii

CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION... 1 CHAPTER 2 SETTING-UP... 3 Supplying Power to the Alnor AVM410/Airflow Instruments TA410... 3 Installing the Batteries... 3 Using The Telescoping Probe... 3 Extending The Probe... 3 Retracting The Probe... 3 CHAPTER 3 OPERATION... 5 Keypad Functions... 5 CHAPTER 4 MAINTENANCE... 7 Recalibration... 7 Cases... 7 Storage... 7 CHAPTER 5 TROUBLESHOOTING... 9 APPENDIX A SPECIFICATIONS... 11 iii

iv (This page intentionally left blank)

Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI immediately. 1. Carrying case 2. Instrument 1

(This page intentionally left blank) 2 Chapter 1

Chapter 2 Setting-up Supplying Power to the Alnor AVM410/Airflow Instruments TA410 The Alnor AVM410/Airflow Instruments TA410 is powered with four size AA batteries. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Alnor AVM410/Airflow Instruments TA410 is designed to operate with either alkaline or NiMH rechargeable batteries, although it will not recharge NiMH batteries. Battery life will be shorter if NiMH batteries are used. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage. Using the Telescoping Probe The telescoping probe contains the velocity, temperature, and humidity sensors. When using the probe, make sure the sensor window is fully exposed and the orientation dimple is facing upstream. N o t e For temperature measurements, make sure that at least 3 inches (7.5 cm) of the probe is in the flow to allow the temperature sensor to be in the air stream. Extending the Probe To extend the probe, hold the handle in one hand while pulling on the probe tip with the other hand. Do not hold the cable while extending the probe as this prevents the probe from extending. Retracting the Probe To retract the probe, hold the handle in one hand while pulling gently on the probe cable with the other hand. 3

(This page intentionally left blank) 4 Chapter 2

Chapter 3 Operation Keypad Functions ON/OFF Key ft/min / m/s Key Press to turn the Alnor AVM410/Airflow Instruments TA410 on and off. During the power up sequence the display will show the following: Model Number, Serial Number, Software Revision, and Last Date Calibrated. Pressing this key changes the display to read air velocity. C / F Key Pressing this key changes the display to read temperature. Changing Units To change units, first put the desired measurement (air velocity or temperature) on the display. Then press and hold the left, unlabelled key for five seconds. Finally, use the and ENTER key to select the units. 5

(This page intentionally left blank) 6 Chapter 3

Chapter 4 Maintenance The Alnor AVM410/Airflow Instruments TA410 requires very little maintenance to keep it performing well. Recalibration To maintain a high degree of accuracy in your measurements, we recommend that you return your Alnor AVM410/Airflow Instruments TA410 to TSI for annual recalibration. Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization (RMA) number. To fill out an online RMA form, visit TSI s website at http://service.tsi.com. U.S. & International UK TSI Incorporated TSI Instruments Ltd. Alnor Products Stirling Road 500 Cardigan Road Cressex Business Park Shoreview MN 55126-3996 High Wycombe Tel: (800) 874-2811 Bucks (651) 490-2811 HP12 3ST United Kingdom Fax: (651) 490-3824 Tel: +44 (0) 149 4 459200 Fax: +44 (0) 149 4 459700 Cases If the instrument case or storage case needs cleaning, wipe it off with a soft cloth and isopropyl alcohol or a mild detergent. Never immerse the Alnor AVM410/Airflow Instruments TA410. If the enclosure of the Alnor AVM410/Airflow Instruments TA410 becomes broken, it must be replaced immediately to prevent access to hazardous voltage. Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage. 7

(This page intentionally left blank) 8 Chapter 4

Chapter 5 Troubleshooting Table 5-1 lists the symptoms, possible causes, and recommended solutions for common problems encountered with the Alnor AVM410/Airflow Instruments TA410. If your symptom is not listed, or if none of the solutions solves your problem, please contact TSI. Table 5-1: Troubleshooting the Alnor AVM410/Airflow Instruments TA410 Symptom Possible Causes Corrective Action No Display Unit not turned on Switch unit on. Low or dead batteries Replace batteries or plug in AC adapter. Dirty battery contacts Clean the battery contacts. Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less-turbulent flow Instrument Error message appears Fault in instrument Factory service required on instrument. W A R N I N G! Remove the probe from excessive temperature immediately: excessive heat can damage the sensor. Operating temperature limits can be found in Appendix A, Specifications. 9

(This page intentionally left blank) 10 Chapter 5

Appendix A Specifications Specifications are subject to change without notice. Velocity: Range: Accuracy 1&2 : Resolution: Temperature: Range: Accuracy 3 : Resolution: 0 to 4000 ft/min (0 to 20 m/s) ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater 1 ft/min (0.01 m/s) 0 to 200 F (-18 to 93 C) ±0.5 F (±0.3 C) 0.1 F (0.1 C) Instrument Temperature Range: Operating (Electronics): 40 to 113 F (5 to 45 C) Operating (Probe): 0 to 200 F (-18 to 93 C) Storage: -4 to 140 F (-20 to 60 C) Instrument Operating Conditions: Altitude up to 4000 meters Relative humidity up to 80% RH, non-condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category II External Meter Dimensions: 3.3 in. 7.0 in. 1.8 in. (8.4 cm 17.8 cm 4.4 cm) Meter Weight: Weight with batteries: 0.6 lbs (0.27 kg) Power Requirements: Four AA-size batteries (included) 1 2 3 Temperature compensated over an air temperature range of 40 to 150 F (5 to 65 C). The accuracy statement of ±5.0% of reading or ±5 ft/min (±0.025 m/s), whichever is greater, begins at 30 ft/min through 4000 ft/min (0.15 m/s through 20 m/s). Accuracy with instrument case at 77 F (25 C), add uncertainty of 0.05 F/ F (0.03 C/ C) for change in instrument temperature. 11

Alnor Products, TSI Incorporated Visit our website www.alnor.com for more information. USA Tel: +1 800 874 2811 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 Airflow Instruments, TSI Instruments Ltd. Visit our website at www.airflowinstruments.co.uk for more information. UK Tel: +44 149 4 459200 France Tel: +33 491 11 87 64 Germany Tel: +49 241 523030 P/N 1980575 Rev. E 2014 TSI Incorporated Printed in U.S.A.