24 Hour Power Protection



Similar documents
FG Wilson Control Systems

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Power Generation. Power Control PCL System Generator Set Control

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Continuous Power... Continuous Protection

FIREDEX Conventional Fire Panels

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

DAB+ / FM Tuner Model: TU-201

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

T Zone Weekly Timer

Transformers from 25va to 500kva. Standard despatch in days not weeks

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

ATS - Automatic Changeover

AM / FM Tuner + RDS. Model: TU

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

GTEC transfer switch open transition

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Diesel Engine Driven Generators Page 1 of 6

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Low Voltage Products. Switches Automatic Transfer Switches

Plug and Socket Devices SolConeX 16 A Series 8570

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Nu-Lec Training Modules

TSC 800 TRANSFER SWITCH CONTROLLER INSTALLATION, OPERATING & SERVICE MANUAL

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Drayton Digistat +2RF/+3RF

know-how Giant in distributing electricity for industry Prisma GK

Thyristor-controlled power supplies and battery chargers

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

The kva RAnge

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Plug and Socket Devices CES 63 A Series 8579

ASCO SERIES 185 Power Transfer Switches

Repeaters and Mimics Data Sheet

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Fire Pump Controllers Remote Alarm Panels

SPL 2-00/-01 OPERATION INSTRUCTIONS

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

GPS INSTALLATION & USER GUIDE. Internet. Compatible with the following controllers. Nomad SD/SD2. ALL RIGHTS RESERVED Rev

PRODUCT LIST Facility DDC Access WebXL DDC

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Electronic Control Devices The European Product Catalogue 2007

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Centro-Matic Automatic Lubrication Systems System Controls

Automatic Transfer Switch Controller

1.44 kw Programmable DC Power Supplies XLN Series

OZW30. Central Unit SYNERGYR

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Product Guide. Low voltage grounding system. Answers for industry.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Everything you need for protection scheme testing

SYSTEM 7000 IRIS+ USER MANUAL

Powerline 1200 User Manual

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Rack Mount LCD KVM Assembly Installer/User Guide

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

NC-12 Modbus Application

Wireless 7 Day Programmable Room Thermostat

Charge Controller CC611/CC612 Preliminary datasheet

Security module CG2 User manual

Product Information Sheet UH28CS-12kV Hi Pot Tester

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

DVB-T 730. User s Manual

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

DSEULTRA DSE333 ATS Control Module Document Number

15 Series - Electronic step relay and dimmer. Features SERIE

Energy Communication Unit (ECU)

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

SMS GSM Alarm Messenger

Quick start: Energy Switch EU

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

CTO Configuration Guide. Eaton Ferrups Ferrups 60Hz RM Series

Diesel Generating Set

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Section TELEPHONE AUTOMATIC DIALER SYSTEM

1. INTRODUCTION FEATURES 2. PROGRAMMING

Monitors. Platea Monitor

RF 1. Contents: Connecting diagram. Detailed information:

Transfer Equipment Controls

Fused Spur Time Switch

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Transcription:

24 Hour Power Protection 365 days a year FG Wilson s range of intelligent Load Transfer Panels offer you peace of mind. The FG Wilson Load Transfer Panel range offers an electronically controlled response to power outages. With flexible, upgradeable options and a high level of functionality FG Wilson transfer panels provide 24-hour automatic control of standby generating sets, 365 days a year. Why buy an ATI/CTI FG Wilson Load Transfer Panel? Automatic and manual operation for increased reliability Manual operation possible without opening the panel Load Transfer Panel range meets ATS IEC 60947-6-1 standard Test operations and sequences are accessible from front panel or remotely Fast acting switch, reducing transfer times between set and utility power Pre-programmed, allowing the panel to run on installation with the ability to customise if necessary Illustration of a Load Transfer Panel Generating set Two Wire Control Load fed from generating set Load Load fed from mains Mains Load Transfer Panel Load Transfer Panel Range

CTI Load Transfer Panel Ratings 63 160 Amps Key: Standard Feature Optional Feature Solid Neutral Kit Allows the connection of neutral cables from utility power, generating set and load without having the neutral broken by the switch during transfer operations. Programmable Countdown Timers Set routine times for delay on starts, delay on transfer, delay on re-transfer and run on timer. Auto/Manual/Test Mode Status Indication Allows on/off load tests at routine service checks. Keypad For straightforward programming and testing. Password protection is included. LCD Display Shows detailed status of system at all times for greater awareness and control. Padlockable Switch can be padlocked in all three positions for added security and safety. Only possible in manual operation mode. System Status Indicators Shows status of utility power, generating set and switch at all times. Manual Handle Fully integrated handle for manual operation. Voltage Sensing Tap Allows for pole voltage sensing. Auxiliary/volt free contacts for remotely monitoring the switch position. Wall Mounting Kit Panel can be wall mounted for greater flexibility in positioning. Terminal shroud For added protection. Auxiliary Controls Auxiliary inputs for automatic control, remote test on load and manual re-transfer. Control Terminals Generating set remote start signal and terminals for remotely monitoring the system. Top and Bottom Cable Entry Aids ease of installation Protection for the control panel Load Terminal Extensions Improving ease of installation Ensuring system safety

ATI Load Transfer Panel Ratings 250 1600 Amps Key: Standard Feature Optional Feature System Status Indication Shows status of utility power, generating set and switch at all RS485 Communications Module Enables access to the system remotely times. Two Wire Start Signal Simple two wire connection for automatic control. through telephone or PC via modem. Volt Free Contacts For power available and generator available. Auto/Manual/ Test Mode Status Indication Allows on/off load tests at routine service checks. LCD Display Shows detailed status of system at all times for greater awareness and control. Manual Handle Fully integrated handle for manual operation. Power Metering To measure load current, kw, kvar, kva, power factor. Padlockable Switch can be padlocked in all three positions for added security and safety. Keypad For straightforward programming and testing. Password protection is included. Solid Neutral Allows the connection of neutral cables from utility power, generating set and load without having the neutral broken by the switch during transfer operations. Wall Mounting Kit Panel can be wall mounted for greater flexibility in positioning (ATI 250 and 400). Bottom Gland Plate Removable gland plate providing increased accessibility with a sizeable area for utility power and generating set cables to be connected. Auxiliary / volt free contacts for remotely monitoring system; switch position, padlock and automatic or manual operation. Programmable Countdown Timers Set routine times for delay on starts, delay on transfer, delay on re-transfer and run on timer. Ensures the safety of system during lightning storms (includes volt free contacts for utility power and generating set). Installation Typical installation set up Wall Mounting Panels Wall mount with ease includes fittings Protection for the control panel Top Cable Entry Aids eased installation

CTI/ATI Standard and Optional Features CTI ATI CTI ATI Motorised Mechanically Held Switch Facility for manual changeover Cable entry Top Bottom Status Indication Utility power available Utility power on load Load Terminal Extensions Improving ease of installation Generator available / Generator on load Utility power and generator off load Manual mode / Automatic mode Test on load / Test off load Manual re-transfer for enabled / required Power / Error indication (LED) Facia Universal symbols to allow for multiple languages For switch position (padlocking & auto/manual - ATI only) Ensuring the safety of system during lightning storms Protection for the control module Liquid Crystal Display (LCD) Utility power L1-2, L1-3, L2-3 voltage Utility power L1-N, L2-N, L3-N voltage Generating set L1-N, L2-N, L3-N voltage Generating set L1-2, L1-3, L2-3 voltage Utility power frequency / Generating set frequency Number of times switch transfers from mains to generating set Timer settings Standards Complete enclosure meets standard IEC 60947-6-1 Switch meets standard AC31B Power Metering To measure load current, kw, kvar, kva, Power factor Volt Free Contacts For utility power available & generator available Communications Module Plug in module that uses Jbus/modbus protocol to allow remote communication of the change over system Voltage Sensing Tap Allowing for pole voltage sensing Controls Under / over frequency failure Under / over frequency restoration Manual / auto re-transfer Mode select push button Solid Neutral Kit To connect neutral cables from the mains, generating set and load Terminal Shroud For added protection Under / over volts failure Under / over volts restoration Delay on start timer Delay on transfer Delay on re-transfer Dead band timer Run on timer Auto / manual control keyswitch Lamp test pushbutton Padlock facility Key: standard feature optional feature Selection between contactor or switch mode

Panel Weights and Dimensions Model Rating A B C Weight kg (lb) CTI 63 63 A 600 (23.6) 400 (15.7) 200 (7.9) 19 (41.8) CTI 100 100 A 600 (23.6) 400 (15.7) 200 (7.9) 19 (41.8) CTI 125 125 A 600 (23.6) 400 (15.7) 200 (7.9) 19 (41.8) CTI 160 160 A 600 (23.6) 400 (15.7) 200 (7.9) 19 (41.8) CTI wall mounted Model Rating A B C Weight kg (lb) ATI 250 250 A 900 (35.4) 600 (23.6) 323 (12.7) 39 (86.0) ATI 400 400 A 900 (35.4) 600 (23.6) 323 (12.7) 44 (97.0) ATI 630 * 630 A 1100 (43.3) 600 (23.6) 398 (15.7) 66 (145.5) ATI 800* 800 A 1375 (54.1) 775 (30.5) 600 (23.6) 125 (275.6) ATI wall mounted ATI 1000* 1000 A 1375 (54.1) 775 (30.5) 600 (23.6) 130 (286.6) ATI 1250* 1250 A 1800 (70.8) 1005 (39.6) 775 (30.5) 230 (507.1) ATI 1600* 1600 A 1800 (70.8) 1005 (39.6) 775 (30.5) 330 (727.7) * Floor standing. Dimension A for the top cable entry model will change to 1350 mm (53.1 in) Floor standing (ATI only) From your local dealer abcde FG Wilson has manufacturing facilities in the following locations: Northern Ireland Brazil China India USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network. To contact your local Sales Office please visit the FG Wilson website at www.fgwilson.com In line with our policy of continuous product development, we reserve the right to change specification without notice. ATI-CTI/0809/GB