Modified Conventional Air Cooling System to Enhance Air Cooling



Similar documents
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Because here you can see a simple an elementary direct evaporative cooling system this is called as a single stage system you can see from the

Lesson 36 Selection Of Air Conditioning Systems

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Glossary of Heating, Ventilation and Air Conditioning Terms

Free Cooling for Data Centers

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Dehumidification Frequently Asked Questions

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

saving energy in comfort Factsheet Recair Enthalpy

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

Feasibility Study of Air Conditioning System With Separated Dehumidification Process Using Low Temperature Exhaust Heat of Ice Storage

The Different Types of Air Conditioning Equipment for IT Environments

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Creating Efficient HVAC Systems

A/C refrigerant system, overview

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

How To Get A Passive House

Molds and mildew are fungi that grow

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

How Ground/Water Source Heat Pumps Work

Evaporative Cooling. Terminology. Date: February 28, Concepts

Housing Fact Sheets. Moisture Condensation at the Windows

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

AIR CONDITIONING TECHNOLOGY

HVAC Systems: Overview

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Simulation of hygroscopic materials in the HVAC system of an office building

Operation and Installation Manual. Max Series

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, November 2015

Automobile Air Conditioning Primer

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

PROCEEDINGS SOLAR 94

HVAC Processes. Lecture 7

THE EFFECT OF ENERGY RECOVERY ON INDOOR CLIMATE, AIR QUALITY AND ENERGY CONSUMPTION USING COMPUTER SIMULATIONS

Performance Test of Solar Assisted Solid Desiccant Dryer

Energy Efficiency. Energy Efficient Home Cooling:

Hospital Application Guide. Cost-effective climate control for hospitals

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

6. Base your answer to the following question on the graph below, which shows the average monthly temperature of two cities A and B.

Defining Quality. Building Comfort. Precision. Air Conditioning

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Pool Dehumidification Basics

EFFECT OF TUNNEL VENTILATION AND EVAPORATIVE COOLING ON THE BARN ENVIRONMENT AND COW COMFORT IN MIDWEST DAIRY FACILITIES

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Halton - Achieving Energy Efficiency in School Design

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

New Trends in the Field of Automobile Air Conditioning

HYDRATES 2009 by David A. Katz. All Rights reserved. Reproduction permitted for education use provided original copyright is included.

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

DEH software (Energy need of air conditioning units)

White Paper: Free Cooling and the Efficiency of your Data Centre

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

ASTACEA4 Inspect complex/central air conditioning systems

How To Understand Evaporator

Analysis of HVAC Control Strategies

Absolute and relative humidity Precise and comfort air-conditioning

How To Design A Building In New Delhi

FLORIDA SOLAR ENERGY CENTER

Air Conditioning Clinic

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Evaporative Cooling for Residential and Light-Commercial

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

We have been working in an ideal climate for thirty years.

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Refrigeration Basics 101. By: Eric Nelson

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Glossary of HVAC Terms

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Chapter 3.4: HVAC & Refrigeration System

Answers to Your Questions from the Webinar

Data Centres. Special Working Group Spin I Relative Humidity in Data Centres

Energy Saving Fact Sheet Air Conditioning

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F.

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Application of sandy bed solar collector system for water extraction from air

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Essam E. Khalil

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Postharvest Sample Questions

Low Cost. Lower Energy Costs. Higher Efficiency.

Lecture No Active summer cooling systems Fan-and Pad cooling system Fog cooling system

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Air-Conditioning Buying Guide

UNIT 2 REFRIGERATION CYCLE

Air Conditioner Cooling Capacity Test AS/NZS :1998

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Improving Data Center Energy Efficiency Through Environmental Optimization

Transcription:

International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869, Volume-2, Issue-4, April 2014 Modified Conventional Air Cooling System to Enhance Air Cooling Diwakar kushwaha, Arindam Ghosal Abstract This paper introduces a modified dedicated outdoor air cooling system for comfort cooling that provides significant cooling. There are different cooling systems used for comfort cooling. These systems may be like air-conditioners; desert coolers etc. and have their own advantages, disadvantages and limitations. Our proposed idea envisages a desert air cooling system which lies in between air-conditioning and conventional desert cooling systems. It would reduce the electricity consumption to a great extent compare to air- conditioning in moderate hot climatic conditions and it provides better cooling than the conventional desert cooler. Its cost will also be well below the existing air conditioning systems. Basically the air cooling in a conventional system happens because of transfer of heat from air as latent heat required for evaporation of water brought in air stream. This air is generally exhausted out of comfort area as air temperature increases due to heat load in the comfort area. If this air is recirculated it will not cool further having become saturated already. If by any means moisture from this air is extracted out, the air can be further recirculated and cooled with evaporative cooling. Thus mixture of fresh and recirculated air will result in better cooling conditions. The idea for auxiliary system to extract moisture out of the air to be recirculated with silica gel, as medium is being developed which will be an attachment to the existing desert cooler[1]. Automatic controls, a subject beyond the scope of this paper, are envisioned to offer the potential to further improve the economic benefits of the lower supply air conditions. The author believes that be an economic, comfort, and health benefits brought about by this system. As a result, the occupants of buildings will experience improved health, comfort, and productivity, and the floor-to-floor dimensions may be reduced. II. EXPERIMENTAL SET UP Index Terms Recirculated, silica jel, silica wheel I. INTRODUCTION With the advent of the various advanced comfort cooling devices, it has become possible to work comfortably for human being in different workstations having non-comfortable climatic condition. These technologies can be applied to places like home, offices, in various transport systems like buses, trains. The proposed dedicated outdoor air cooling systems provide the latent cooling while maintaining the space relative humidity and much reduced energy consumption. The provision of cooling in buildings has always presented designers a greater challenge. Early cooling systems made use of natural draft and evaporative effects, and this knowledge is being revisited today as building designers strive to provide cooling that does not incur a heavy environmental cost. It is believe that the productivity of workers is related to the temperature and humidity of their working environment. This study begins with an overview of the requirements for thermal comfort in terms of temperature, humidity and air movement. Manuscript received April 16, 2014. Diwakar Khuswah, Department of Mechanical Engineering, Dronacharya Group of Institutions, Greater Noida, (U.P.) India Prof. Arindam Ghosal, Department of Mechanical Engineering, Dronacharya Group of Institutions, Greater Noida, (U.P.) India Fig.1,Block diagram of cooling system operation Desiccant air cooler-active desiccants are a better choice for indoor comfort cooling by maintaining the relative humidity of within the room air temperature. Vents- vents are used for the flow of humidified and dehumidified air to various places of the system. Space for cooling space for cooling is likely a room or a building. Exhaust fans- Exhaust fans are used mainly for the forced and controlled flow of humidified and dehumidified air as per load condition. Silica gel reference [1] Silica gel is usually prepared by treating sodium silicate of a suitable concentration with an acid such as hydrochloric acid, or with certain salts, such as ferric chloride acid, which are acid in reaction. The gelatinous mass thus formed is broken up, washed free from salts, and dried until the gel becomes hard and glassy in appearance. After the addition of water content to this mass is called as activated silica also termed as silica gel. Spaces between silica threads are filled with capillarity held water. The effective 182 www.erpublication.org

Modified Conventional Air Cooling System to Enhance Air Cooling diameters of these pores have been estimated to be approximately 5 micron. The water content in silica gel gets evaporated due to heat exchange with its surrounding. Due to this property silica gel is used which is reactivated again and again.[2] Silica gel wheel-silica gel wheel is a motor driven cylindrical plastic wheel in which the silica gel crystals are packed within the various separated sectors. III. SYSTEM OPERATION Initially the atmospheric air enters in desiccant through the inlet vent of the desiccant and it is humidified in it, after humidification the processed air is propelled towards the room where it exchange the sensible heat of the room and it becomes warm. Now the warm air still contains the water particles and the temperature is still lower than the atmospheric air, now this air is further carried to the inlet vent of the rotating silica gel wheel which contains silica gel packed in various sector of the cylindrical wheel. The air is passed through the silica gel and gets dehumidified due to the property of silica gel, now through the out let of the silica gel wheel which is further a vent connects the out let of the silica gel wheel to the another inlet of desiccant air cooler. Another side of the silica gel wheel is also provided an inlet and outlet vents but opens in atmospheric air. Through this inlet port warm atmospheric air enters and by carrying the moisture of the silica gel which is recently absorbed and due to rotation came to this side, it gets diffuse in atmosphere and therefore the silica gel reaching this side loss the water content with it and now it is again prepare to absorb the moisture from the humidified air stream at the opposite side. Due to rotation of the silica gel wheel the process is repeated again and again and therefore the processed air gets more and more cooled. IV. CONCLUSION Properly engineered, this modified system should ensure that thermally comfortable environmental conditions are achieved in the building. The proposed idea of modified cooling system ensures against previous outdoor air cooling systems in reference of good displacement ventilation Airflow rate although with the cooling loads. In period of continuous and peak cooling demands this system will also work effectively. This system can be used for greater space design occupancy. Along with the comfort, and health aspects the system will be reliable at great extent. This system cannot replace the AC systems but likely to perform well in moderate hot climatic conditions. REFERENCES [1] F.E. Bartell and e. G. Almy, activated silica gel - The Relation of Activity to Water Content and Temperature [2] www.silicagel.in 183 www.erpublication.org