A loop puts you in command. The PreBilge system for bilge water treatment



Similar documents
12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

ST. VINCENT AND THE GRENADINES

Oily Water Separator SKIT/S-DEB

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

PureBilge. Technical information for bilge water treatment

Fuel Treatment and Conditioning Systems

Flex separation systems, S-separators

Separation technology solutions from GEA Westfalia Separator for the treatment of fluids in industrial applications

Technical Bulletin. Oil Record Book entries: Machinery space operations (Part 1) Including January 2011 amendments to Technical Bulletin 24

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Automatic filters for fuel and lubricating oil. Technical information for oil filtration

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

Tank Heating Solutions. For Oil Spill Response Vessels

HYDROCARBON REMOVAL FROM AMINES DEMONSTRATED EXPERIENCE ABSTRACT

PureDry. Technical information Waste Fuel Recovery and Sludge minimization

Introducing Vessel Environmental Compliance Reporting and Energy Management: From ESRG

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Exhaust Scrubbers. What you need to know. Move Forward with Confidence

Total water management. Water and wastewater treatment systems for ships and offshore

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Ballast Water Management Regulations and Challenges

VDL Klima. Marine cooling solutions. Strength through cooperation

Alfa Laval PureBallast 3.1

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County

Uniform Application of MARPOL Annex I, Revised Regulation 12

Heating Water by Direct Steam Injection

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

A Guide to Trouble-Free Cooling Towers

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

INTEC Engineering GmbH Heating Solutions for the Marine Industry

CHAPTER PETROLEUM CONTACT WATER

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS

Oily Water Separators

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Spill Prevention, Control and Countermeasure (SPCC) Rule

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Routine and Emergency Boiler Operation

ежглеяис тгс йубеямгсеыс

DECANTER CENTRIFUGE. CENTRIFUGE TECHNOLOGIES

How To Prevent Over Water Activities

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

TABLE OF CONTENT

MU Cooling System. Hi-Pres. Low sulphur fuel cooling system. System specifications HI-PRES MARINE & OFFSHORE

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

DIESEL FUEL CONDITIONING

Factory owners must ensure the boiler is:

MARINA ENVIRONMENTAL MANAGEMENT POLICY

5.2. Vaporizers - Types and Usage

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

GEA HB Craft Brew Series. Plug & Brew Centrifuges for Small and Mid-sized Breweries. engineering for a better world

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Are these noise cancelling devices needed to make your chiller quiet??

MONITORING & MEASURING EQUIPMENT FOR EMISSIONS CONTROL, HAZARD DETECTION & ENERGY OPTIMIZATION

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Quik Lining Systems Heater Owners Guide

Energy Saving Fact Sheet Boilers

- Save lives and reduce material damage

FLASH TANK ECONOMIZER PRODUCT GUIDE

SEPAR FILTER SEPAR 2000 SEPAR 2000

Fossil Energy Study Guide: Oil

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

FUELING AND FUEL STORAGE

Environmental Management System Procedures

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Diesel fuel in winter The effect of cold weather on fuel systems

C. starting positive displacement pumps with the discharge valve closed.

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Mechanical shaft seal types and sealing systems

Mechanical Seal Piping Plans

Cooking at the Speed of light!

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

Fire & Explosion Risks in Service Stations

Improving Diesel Engine Life:

Marine after-treatment from STT Emtec AB

USE OF PHOSPHATES IN THE UNITED STATES NEAR COSTAL AREAS

Why is my air conditioner dripping on my customers?

AUTOMATIC TANK CLEANING (ATC) LITE On-the-fly automatic tank cleaning and recycling technology

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Domino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD

Jobson THE RIGHT CONTACT

CIMAC Guideline

Grease Trap Maintenance, Procedures and Cleaning Logs

Basic Hydraulics and Pneumatics

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

LNG as Ship Fuel. Effects on Ship Design, Operations and Supporting Infrastructure

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

UNITOR ULTRASONIC cleaning

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

The Secret of Hydraulic Schematics. BTPHydraulics

Link-Up. Solid Fuel Association Guide to Central Heating.

Efficiency on a large scale CFB Steam Boilers

National Precast Concrete Association

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

Transcription:

A loop puts you in command The PreBilge system for bilge water treatment

Essential consistency Contents Overview 4 Background 6 Regulations 10 Technology 14 Equipment 18 Support 22 The marine environment is fragile, and the threats it faces are complex. Unfortunately, the process of reducing those threats is also complicated, especially when it comes to bilge water treatment. Alfa Laval understands the need for simple solutions that function as promised. This understanding is the basis for our PreBilge system. Installed as a helping hand for existing bilge water treatment systems, PreBilge forms a continuous pre-treatment loop that does away with performance issues. At all times and in all conditions, PreBilge ensures predictable compliance with bilge water legislation. And by eliminating the need for filters, it leads to lower, more predictable operating costs. 2 3

Take command over bilge water treatment As authorities try to bring bilge water emissions under control, many of today s bilge water treatment systems are out of control in terms of both their performance and their operating cost. If you use a gravitational coalescer, you have almost certainly experienced oil-in-water alarms or invested heavily in fi lters to prevent them. This is because gravity alone can never compete with modern bilge water mixtures and the motion of a vessel at sea. But while more effective technologies exist, they may involve too much cost or complication to justify a switch. Introducing PreBilge a pre-treatment loop Today there is a solution that requires no switch at all. PreBilge from Alfa Laval lets you take command over your bilge water treatment system, doing away with alarms, fi lter maintenance and excessive fi lter costs. PreBilge is installed as a continuous pre-treatment loop for your existing system, starting and ending at your bilge water tank. Just as lube oil is circulated through a lube oil separator for cleaning, bilge water is circulated through PreBilge, which uses centrifugal separation to keep the bilge tank contents from reaching a critical level. No change to your IOPP certifi cate is required. And with a clean bilge water feed, your existing system can fi nally do what it was intended to do: discharge clean water in compliance with bilge water regulations. PreBilge is a unique solution that solves the problems of underperforming bilge water treatment systems. Installed as a pre-treatment loop, it provides the existing system with a clean and problem-free feed. A loop lets you do more A pre-treatment loop ensures that your bilge water treatment system does its job, which gives you more time to do yours. With PreBilge in continuous operation, crewmembers waste no more time monitoring treatment and investigating oil-in-water alarms. A loop keeps you secure Instead of adding fi lters, PreBilge adds security by creating a bilge water feed your existing system can handle. PreBilge uses centrifugal separation, which is the most effective means available for dealing with complex bilge water and emulsions. A loop brings order Because PreBilge effectively does away with the need for fi lters, it creates consistency and brings your bilge water treatment costs under control. Instead of frequent fi lter changes and unpredictable downtime, you receive constant uptime and predictable operating economy. 4 O V E R V I E W O V E R V I E W 5

From deck to hull Bilge water is the collective name for the contents of a ship s bilge wells, which are located just above the hull in the lowermost part of the vessel. While the name itself is simple, however, the composition of bilge water is anything but. What collects in the bilge wells can come from practically anywhere on board. To begin with, the wells receive water and fluids from operational sources, such as technical rooms, propulsion systems and various equipment throughout the ship. In addition, they take in fluids from machinery spaces, internal drainage systems, sludge tanks and a wide variety of other areas. Some of these flows are relatively continuous and predictable, such as the water coming from the separator sludge tank or from cleaning processes in the vessel s engine room. But others are intermittent at best. Soot, particles and fluid from leakage and spills all make their way into the bilge wells, yet their concentration can vary from one moment to the next. This constantly changing nature makes bilge water difficult to define. 6 B A C K G R O U N D 7

Solids Solids The modern mixture Fifty years ago, bilge water was easier to deal with. Back then, what collected in the bilge wells was mainly diesel oil and water, which could easily be separated by means of Feed Coalescence of droplets Flocculation of particles Coalescence of droplets Flocculation and coalescence are two common and effective processes for breaking down emulsions. Both can be induced mechanically by means of high centrifugal force. Flocculation of particles gravitational force. This is the reason for the traditional settling tanks that are still so common today. Modern bilge water, however, is a far more complicated challenge. In addition to diesel oil and water, it contains heavy fuel oil, lube oil, hydraulic oil, oil additives, chemicals and detergents. Not to mention particles such as catalytic fi nes, soot and dirt. All of these substances are channelled into the bilge water holding tank, which is kept at an elevated temperature that facilitates separation into three distinct phases. The top phase is a thin layer containing most of the oil and organic solvents, which should be skimmed off for separate treatment. The bottom phase, which is also removed for sepa- Feed rate treatment, consists of solids and heavy sludge. In between is the phase to be handled by the bilge water treatment system, which contains water polluted by oil, Coalescence of droplets chemicals and particles. While gravity is enough for this primary separation, it has diffi culty achieving the secondary treatment needed before bilge water can be discharged. Inseparable diffi culties A major reason why gravity fails to separate modern bilge water completely is the presence of emulsions. Emulsions are smooth and even mixtures of liquids that do not dissolve in one another, such as the mixture that occurs when pump agitation or valve throttling blends small droplets of oil into the aqueous phase of bilge water. Emulsions can be diffi cult to break down in normal circumstances, and they are often stabilized by the presence of particles and surfactants. Surfactants, which lower the surface tension of liquids and facilitate spreading, have become increasingly common in the detergents and chemicals used for cleaning and maintenance. To destabilize emulsions, methods that induce fl occulation or coalescence are most often used. Flocculation is a process in which particles aggregate without losing their individual identities, whereas coalescence is a process in which smaller droplets combine to form larger ones. These two processes can be encouraged by raising the temperature and ph value of the bilge water, or by adding chemicals that cancel out the repulsive electrostatic forces between particles and droplets. In addition, there is a simple and chemical-free alternative. Both fl occulation and coalescence can be induced mechanically by means of high centrifugal force. 8 B A C K G R O U N D B A C K G R O U N D 9

Taking chances All ships must have systems for bilge water treatment, including an oil-in-water monitor that sounds an alarm when the oil content is higher than 15 ppm. IMO resolution MEPC 60(33) and MEPC 107(49) allows only separated bilge water with an oil-in-water content of 15 ppm or less to be discharged into international waters, and today tougher limits can be found in more sensitive regions. In the Great Lakes region of North America, for example, an oil-in-water limit of 5 ppm is already in effect. The penalty for non-compliance with these regulations is severe. Even minor infringements can lead to massive fines, and both company management and individual crewmembers can receive lengthy prison sentences for bilge water violations or improper recordkeeping. Given the consequences of failure, ship owners and ship operators are eager to comply. But with the solutions that are common today including those approved by IMO many are still forced to take risks. 10 R E G U L A T I O N S 11

Questionable standards Despite the clarity of the bilge water limits, many vessels are struggling to meet them. In part, this is due to the type approval process that regulates bilge water equipment. Prior to 2005, type approval was governed by IMO resolution MEPC 60(33), which required only that treatment systems be tested with a mixture of oil and water. Because no emulsions or heavier oils were involved in the testing, simple gravitational coalescers had no difficulty gaining approval. In fact, the wording of MEPC 60(33) acknowledges its own insufficiency. The resolution clearly states, It should be understood that a gravitational filtering equipment cannot be expected to be effective over the complete range of oils which might be carried on board ship, nor can it deal satisfactorily with oil of very high relative density or with a mixture presented to it as an emulsion. In addition, the resolution suggests that care should be taken that the bilge water is fed to the filtering equipment after the emulsion has broken. Today s MEPC 107(49) is stricter, requiring testing with a stable emulsion that contains fine particles and a surfactant chemical. However, it still does not reflect reality. Whereas MEPC 107(49) requires testing with one chemical, real bilge water is a complex and ever-changing cocktail of chemicals. Moreover, the tests are performed for a short duration of just 2.5 hours in stable conditions on shore. Without having to handle realistic bilge water, a realistic timeframe or the pitching and rolling that occur at sea, marine manufacturers have it easy. They have continued to use the same gravitational coalescers that were approved under MEPC 60(33), employing the questionable practice of adding an absorption filter simply to pass the brief emulsion test. Most of today s bilge water treatment systems are constructed and dimensioned specifically for the type approval process which leaves them inadequate for dealing with real-world conditions. Uncomfortable choices Put simply, countless ship owners and ship operators have bilge water treatment systems that either cannot do the job or cannot do it economically. Gravitational coalescers are sensitive to oil shocks and ineffective against difficult emulsions, and they lose their efficiency in rough weather and rolling seas. This puts ship owners and ship operators in a difficult position. Few vessels have the manpower for proper good housekeeping or the space for additional holding tanks. Extra filters can be added, but these must be stocked on board and add considerably to operating costs. If the tanks are full and no spare filters are available, there is simply no choice but to risk pumping waste overboard. Up to now, the only true fix has been upgrading to a high-performance bilge water treatment system, such as a stand-alone centrifugal separator. But even this is not a perfect solution for all vessels. Space limitations, cost issues or the complexity of updating the vessel s IOPP certificate can make this an unattractive option. Today, however, there is yet another option in the form of PreBilge. 12 R E G U L A T I O N S 13

Economical assistance PreBilge is a new way of thinking, and one that provides an effective and economical fix for underperforming bilge water treatment systems. Although it is a centrifugal separator the most effective technology for dealing with complex bilge water it is not designed to replace your existing system. PreBilge works together with gravitational coalescers and other bilge water treatment systems already approved according to MEPC 60(33) or MEPC 107(49). Compact and efficient, it acts as a helping hand, providing pre-treatment that keeps the bilge water composition at a manageable level. Since the discharge and oil monitoring are handled by your existing system, PreBilge does not require its own type approval or affect the vessel s IOPP certificate. In other words, PreBilge is an easy opportunity to solve bilge water treatment difficulties. You can now ensure regulatory compliance and reduce operating cost, but with minimal effort and no change to the vessel s paperwork. 14 X T E C H N O L O G Y 15

Continuous pre-treatment PreBilge is a pre-treatment solution for bilge water, but one that operates continuously rather than in a single step. Placed anywhere in the engine room, the PreBilge separator is connected in a loop that starts and ends at your bilge water tank. In turn, this reduces the demands on the crew. When no alarms are triggered, there are no problems for crewmembers to investigate and rectify. Even on the roughest of seas, the bilge water treatment system can operate independently so that no one has to spend time in the engine room monitoring its performance. The setup is comparable to that of a lube oil separator, which is connected in a loop to the lube oil tank. Lube oil leaves the tank and passes through the centrifugal separator, after which the cleaned oil is returned to the tank. Just as the lube oil separator keeps the oil in the lube oil tank clean, PreBilge uses centrifugal separation to remove Space and money saved A clean feed to the existing bilge water treatment system also removes the need for a fi lter backup, which has a number of positive effects. Apart from saving the crew the time of changing absorption fi lters, it frees up considerable space when no fi lters have to be stored on board. Cleaning and maintenance Drains and leaks Water from purifier sludge tanks Water from waste oil tank impurities from the bilge water tank. And like a lube oil separator, PreBilge is designed to run non-stop, even on rough seas and in harsh conditions. In fact, PreBilge requires only routine maintenance once every 2000 hours. No alarms, no wasted time Using centrifugal force that is 6000 times stronger than gravity, PreBilge removes the heavy oils, particles and Most importantly, eliminating fi lters can reduce a vessel s operating costs by thousands of euros per year. Filters are expensive, so when PreBilge is put into operation, the operating costs for the existing bilge water treatment system are instantly minimized. With PreBilge, not only is the performance of the bilge water treatment system consistent, the costs of operating it are as well. Tank overflows Incidents Bilge pump Bilge water tank Condensate from air coolers emulsions that pose diffi culties for gravitational coalescers. This creates a problem-free feed to the existing bilge water treatment system, which effectively does away with oil-in- Bilge well Bilge well water alarms. 16 T E C H N O L O G Y T E C H N O L O G Y 17

A pre-treatment loop PreBilge is installed as pre-treatment loop for your existing bilge water treatment system, through which bilge water is continuously circulated. Because bilge water is drawn from and returned to the bilge water tank, PreBilge is not used to pump any water overboard. Rather, discharge and oil-in-water monitoring is handled by your existing treatment system. The PreBilge system Capacity: PreBilge has a capacity of 500 l/h, although this is relatively unimportant since the system operates continuously. A capacity of 500 l/h represents a flow of more than 10 m 3 /24 h, which is ten times the rate at which vessels 1260 mm 800 mm Since PreBilge is non-essential equipment and is not normally accumulate bilge water. involved in the pumping of bilge water overboard, it does not require type approval from any classification society. Footprint: The PreBilge module has a footprint of 1.5 m 2. Since it can be installed anywhere in the engine room, the installation flexibility is extremely high. Operating power: Different power alternatives accommodate a wide range of customer needs. PreBilge is available in 230V, 400V, 440V, 460V and 690V, 50Hz and 60Hz configurations. 1750 mm 1250 mm *IMO approved Oily Water Separator Delivery and connections PreBilge is delivered as a compact module that is easy to install and can be flexibly placed in any engine room. Pipe connections can be drawn as needed, and there is no required proximity to the vessel s bilge water tank. Although PreBilge is not equipped with its own oil-in-water monitor, both the feed pipe and clean water outlet have sample valves that allow the operator to visually check its performance. Heating options: Several heating options are available for PreBilge: Steam heater Electric heater PHE to use hot water as heating media (e.g. engine cooling water) All of these options are incorporated into the PreBilge module, which means they have no effect on the system footprint. It is also possible to install PreBilge without its own heating if heating coils or immersion heaters are otherwise available. Feed pump: PreBilge utilizes a progressive-cavity feed pump, installed on a separate skid. 18 E Q U I P M E N T E Q U I P M E N T 19

A dynamic force The central component of the PreBilge system is the BWPX 303 centrifugal separator. For crewmembers already acquainted with centrifugal separators for fuel and lube oil treatment, it offers familiar operation and a very short learning curve. Centrifugal separation is the most efficient means of dealing with complex bilge water and the only one that works consistently at sea. This is why even a small add-on system such as PreBilge can solve the performance problems of larger gravitational coalescers. A high-speed, disc-type centrifugal separator multiplies the force of gravity many thousands of times. In the case of PreBilge, the BWPX 303 separator produces a gravitational force of 6000 g, which separates water, particles and oil droplets with extreme efficiency. To achieve the same result alone, a gravitational coalescer would have to possess a settling area of 3000 m 2. The BWPX 303 separator Hydraulic capacity: ~ 2.0 m 3 /h Utilized capacity: 0.5 m 3 /h Bowl volume: 1.5 l Sludge space volume: 0.6 l Discharge volume: 1.0 l > 9000 rpm Motor power: ~ 1.5 kw Bowl material: AL 2377 CIP-enabled: Yes Configuration: Concentrator with a unique solid-handling distributor design At the same time, a centrifugal separator counteracts the constant motion of the ship. Pitch and roll are overcome by the gyroscopic effect of circulating the liquid in the separator bowl, which means separation efficiency is ensured in any operating conditions. 20 E Q U I P M E N T E Q U I P M E N T 21

At your service For ship owners and ship operators with difficulties in bilge water treatment, PreBilge is a cost-effective way to secure performance and ensure an oil-in-water content within the established limits. No changes are required to the existing system, and there is no need to stock filters or set aside space for oily reject. For crewmembers, PreBilge is a boost in efficiency. Instead of monitoring the performance of the bilge water treatment system or dealing with the consequences of oil-in-water alarms, they can devote their time to better things. For everyone, PreBilge offers security in the form of global backing. Alfa Laval has a century in of experience working with maritime industry, and PreBilge is accompanied by a well-developed offering of service and support. No matter where your ship sails, you will find access to technical assistance, onboard service and genuine spare parts from our dedicated team of peace-of-mind specialists. 22 X S U P P O R T 23