Datasheet. Fiber-Optic Glass Yarn Cable Single Loose Tube and Multi Loose Tube Features



Similar documents
GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

ESPECIFICACIÓN DE PRODUCTO

Fibre Optic Indoor/Outdoor Cable

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

Fibre optic cables MDIC LSZH

Discontinued. Volition. Fiber Optic Cable. 3Innovation

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

OPTICAL FIBER CABLES

home site map help ECMS Project: Standard / Federal Oversight Advertised

Industry solutions: Broad cast

Optical Fibers Fiber Optic Cables Indoor/Outdoor

SINGLE MODE OPTICAL FIBER FTTH CABLE

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

Application Note Fiber Optic Standards Reference Guide

Models HP Switch. HP PoE Switch

Fiber Optic Specifications

QuickSpecs. Models HP X132 10G SFP+ LC ER Transceiver. HP SFP+ Transceivers (SR, LRM, LR and ER) Overview

QuickSpecs. HPE OfficeConnect 1410 Switch Series. Overview. HPE OfficeConnect 1410 Switch Series. Models. Key features.

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

CISCO 10GBASE X2 MODULES

P URCHASING D IVISION

QuickSpecs. Models HP X131 10G X2 CX4 Transceiver. HP X131 10G X2 Transceivers (SR, LRM, LR, ER and CX4) Overview. HP X131 10G X2 SC LRM Transceiver

Fiber Optic Cable Products. Leading Solution

FIBER-OPTIC CABLES LWL-KABEL

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

The Importance of minembc Laser Bandwidth Measured Multimode Fiber for High Performance Premises Networks White Paper

P URCHASING D IVISION

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Polymer Coated Fiber Cable (PCF)

Communication, Signal & Data Cables

FIBER-OPTIC CABLES LWL-KABEL

How To Get A Better Signal From A Fiber To A Coax Cable

Fibre Optic Cable. Catalogue.

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

SINGLE MODE OPTICAL FIBER CABLE

APR 2016 Rev M

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

OFS AllWave Zero Water Peak (ZWP) single-mode

SFP Transceiver Specifications

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

With the advent of Gigabit Ethernet

QuickSpecs. Models. ProCurve Mini-GBICs Overview. ProCurve Gigabit-LX-LC Mini-GBIC. ProCurve Gigabit-LH-LC Mini-GBIC

Fiber Optics: Fiber Basics

OM4 Capability Brochure.

Attaching the PA-A1-ATM Interface Cables

QuickSpecs. Models HP PS G Switch

industry solutions: Security

QuickSpecs. HPE OfficeConnect v2 Switch. Overview. HPE OfficeConnect 1810 Switch Series. Models. Key features.

Microbend evaluation of selected G652D & G657 fibers and ribbons before cabling

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Fiber Optic Cable

What are Fibre Optics?

MacArtney Underwater Cables - In stock

Plug & Play Universal Systems

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Fiber Selection and Standards Guide for Premises Networks

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

WHITE PAPER. 50 versus 62.5 micron multimode fiber

Network Topologies and Distances

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

European Normative EN system

Fibre optic testing best practices

The following terms are defined within the context of the fiber optic industry

Cisco SFP Optics for Gigabit Ethernet Applications

Corning Specialty Fiber. Product Information Sheets

Models HP Switch. HP G Switch

QuickSpecs. Models HP G Switch

White Paper. Gigabit Ethernet over fiber optics

Reliable, Consistent, Quality

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Service Description blizznetdarkfiber

Wavelength Division Multiplexing

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

ETD Fiber Optic Products

SPECIALTY FIBER OPTIC CABLE. Downhole Subsea Sensing Equipment

Guide to Patch Cords. and Pigtails.

Ethernet/IEEE evolution

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Intel Ethernet SFP+ Optics

QuickSpecs. Models HP Switch

7.4 3M No Polish Connector

Ethernet 102: The Physical Layer of Ethernet

HP G Switch. HP G-PoE+ (185W) Switch. HP G-PoE+ (370W) Switch

EXAMPLE OF RELEVANT STANDARDS

Optical Fibre Solutions

HARTING Ethernet Cabling 8-poles Overview

Transcription:

Features Single Loose Multi Loose Single Loose Tube: a compact loose tube cable contains a single loose tube with up to 12 fibers Multi Loose Tube: A loose tube cable with a dielectric central member contains up to 12 tubes, each tube contains up to 12 fibers Color coded fibers for easy identification Operating temperature range: o Single Loose Tube: -20oc-+70oc o Multi Loose Tube: -40oc-+70oc Water blocking thixotropic gel prevents ingress of water Dry water swelling glass yarn for strength and prevention of water penetration Available with four fiber types Single-Mode, Multi-Mode 50/125, Multi-Mode 50/125 OM3 and Multi-Mode 62.5/125Single Loose Tube: A central loose tube cable with up to 12 fibers Page 1 of 7

Description A central loose tube cable with up to 12 fibers for single loose and up to 144 in a multi tube design. All are color coded for easy identification. (Refer to table in ). The glass yarns are protected by a UV resistant LSZH (low smoke, zero halogen) jacket. Page 2 of 7

Mechanical and Environmental Characteristics Single Loose Test Detail IEC-60794-1-2 Test Method Test Procedure TIA/EIA-455 FOTP No Maximum Pulling Load 1500 N E1 33 Maximum Operating Load 60% of pulling load E1 33 Minimum Bending Radius Installation Long Term 20 x cable O.D 10 x cable O.D E11 104 Max. Compressive Loading 3,000N E3 41 Repeated Impact 4.4 N.m (J) 3x2 impacts E4 25 Twist (Torsion) 20 times the cable O.D. E7 85 Storage Temperature Range Operating Temperature Range Core Fluid Penetration Multi Loose -40 o c to +70 o c F1 3-20 o c to +70 o c F1 3 1 m sample, 1m water head for 24 hours Test Detail IEC-60794-1-2 Test Method Maximum Pulling Load 2700 N or 1 cable weight per km, the higher. F5 82 Test Procedure E1 33 Maximum Operating Load 60% of pulling load E1 33 Minimum Bending Radius Installation Long Term 20 x cable O.D 10 x cable O.D E11 37 Max. Compressive Loading 5,000N E3 41 Repeated Impact 4.4 N.m (J) 3x2 impacts E4 25 Twist (Torsion) 125 x cable O.D E7 85 Storage Temperature Range -40 o c to +70 o c F1 3 TIA/EIA-455 FOTP No Operating Temperature Range Fluid Penetration -50 o c to +70 o c F1 3 1 m sample, 1m water head for 24 hours F5 82 Page 3 of 7

Nominal Dimensions and Weight Single Loose Tubes nominal diameter: Outer jacket nominal thickness: Nom. Cable Weight Nom. Cable Diameter Technical Characteristics Multi Loose 3.3mm 1.5mm 55kg/km 7.5mm No. of fibers No. of tubes Nom. Cable Weight (kg/km) Nom. Cable Diameter (mm) 2-60 1-5 90 11.0 24-72 6 100 11.5 32 96 8 130 12.5 40 120 10 160 14.0 48-122 12 180 15.5 Unit Number Color Unit Number Color 1 Blue 7 Red 2 Orange 8 Black 3 Green 9 Yellow 4 Brown 10 Violet 5 Grey 11 Pink 6 White 12 Turquoise Page 4 of 7

Single-Mode Fibers Standard Parameter Attenuation, Loose Tube Cables: @1310 nm @1550 nm @1625 nm Dispersion: between 120 and 1360 nm (O Band): between 1530 and 1565 nm (C Band) between 1565 and 1625 nm (L Band) Standard per ITU-T G.652D 0.35 0.22 0.25 3.5 18 22 Units db/km ps/(nm*km) Zero Dispersion Wavelength 1311±11 nm Mode Field Diameter @ 1300 nm 9.2±0.5 @1550 nm 10.4±1.0 Cable Cut-off Wavelength 1260 nm PMD (Individual fiber) 0.2 ps/km 1/2 Cladding Diameter 125±1.0 Core/Cladding Concentricity Error 0.5 Cladding Non-Circularity 1.0 % Coating Diameter (un-dyed) 245±10 Proof-Test Level 0.7 GN/m 2 Page 5 of 7

Multi-Mode Fibers Standard Parameter 50/125 50/125 62.5/125 ISO/IEC 11801 OM2 OM3 OM1 - Classification (2) Units Attenuation, Loose Tube Cables: @850 nm 2.8 3.0 db/km Bandwidth (2) @1300 nm @850 nm @1300 nm 0.8 500 (3) 2000 (4) 800 (3) 500 1.0 200 500 Numerical Aperture 0.20>±0.015 0.275±0.015 MHz*km Core Diameter 50±3 62.5±3 Cladding Diameter 125±2 125±2 Core Non Circularity 6 6 % Cladding Non-Circularity 2 2 % Core/Cladding Offset 3 3 Coating Diameter (Un-dyed) 245±10 245±10 Proof-Test Level 0.7 0.7 GN/m2 1. Overfill launch measurement as per TIA-445-204 2. Effective Modal Bandwidth as per IEC 60793-2.10 Page 6 of 7

Multi-Mode Fiber GbE and 10 GbE Link Lengths Fiber Type 62.5/125 50/125 50/125 11801 Code (2) OM-1 OM-2 OM-3 Bandwidth (3) : @850 nm 200 MHz.km 2000 MHz.km @1300 nm Link Length for GbE (5) @ 850 nm (1000BASE-SX) @ 1300 nm (1000BASE-LX) 220 m 550m 550m 550m 970 m 550 m Link Length for 10 GbE (6) @ 850 nm (10GBASE-SR) @1300 nm (10GBASE-LX4) 33 m 300m 82 m 300m 300 m (8) 300m 1. For other fiber specification and additional details, consult RiT s sales department. 2. As per ISO/IEC 11801:2002 or EN 50173. 3. Overfill launch measurement as per TIA-455-204 4. Effective Modal Bandwidth as per IEC 60793-2.10 5. Per IEEE 802.3z, assuming the requirements of the Standard and associated documents are met. 6. Per IEEE 802.3ae, assuming the requirements of standard and associated documents are met. 7. Calculated using the 10GbE link model 8. This link length is assured provided that: a. It is installed per the maximum channel insertion loss requirement of 2.6dB as outlined in the TIA 568 B.3-1, ISO 11801 2 nd Ed, and IEEE 802.3ae. The maximum channel insertion loss requirement of 2.6 db assumes a maximum connection loss of 1.5 db and a maximum cable attenuation of 3.5 db/km at 850nm. b. It is used with an IEEE 802.3ae compliant 10GBASE-SR or 10GBASE-SW ports meeting the specifications, among other, for encircled flux as defined in Table 52.7 in IEEE 802.3ae. Page 7 of 7