WIDE RANGE GAS MONITOR



Similar documents
RADIATION MONITORING SYSTEMS

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Online Infrared Flue Gas Analyzer Gasboard 3000

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Centro-Matic Automatic Lubrication Systems System Controls

TC-9102 Series Surface Mount Temperature Controllers

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

HEAVY WATER LEAK DETECTOR

Sanitary Type Electronic Flow Switches

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Medical Air Systems: Scroll

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Duct Humidity Transmitter

WD-AMX Water Detection Controllers

Temperature & Humidity SMS Alert Controller

In-Line Electronic Flow Switches

Analytical Instruments Smart Analyzer 90 Type SMA

Commercial Refrigeration Temperature and Defrost Controls

Electronic Flow Switches

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Application Requirement

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

SMS GSM Alarm Messenger

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SafePoint RMS. Sustainable Committed Secure. SafePoint. Monitoring Solutions

The Universal DAQ Device. Connect and measure immediately!

Rackmount Intelligent Pressure Scanners

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

Radiation Monitoring System RMS

KNC Model 3666 Automatic Pressure Calibration System

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

T7079A,B Solid State Remote Temperature Controllers

Thyristor-controlled power supplies and battery chargers

For Multi-Parameter Meters see mvx

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Instruction Manual. T3111 T3111L T3111P T3111Ex

THERMAL MANAGEMENT SOLUTIONS

WEATHER STATION FOR SOLAR FARM MONITORING

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Cooling Channel Optimization

TAC I/NETTM MR-AHU-HP. Application Specific Controller

BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER

In-Line Electronic Flow Switches

ngenieros Ingenieros Asociados De Control S.L.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Electronic Control Devices The European Product Catalogue 2007

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

T0118 T2118 T3118. Instruction Manual

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Remote RadEye Product Family

Interface Level And Point Level Analyzers & Sensors

Introduction To SCADA and Telemetry

Repeaters and Mimics Data Sheet

Gas Custody Transfer Calibration

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

3466 Building Energy Management Training Systems

4-20 ma Transmitters Alive and Kicking

Programming Logic controllers

Table of Contents. TransformerIQ FAQs 1

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Element D Services Plumbing

IO-DIM6 6-Channel, Digital to Analogue Converters

ABB PSPS Erich Steinmann; Generator control-2013

MP-4000 Alarm List (Software version or later)

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Everything you need for protection scheme testing

Desiccant Air Dryers Heatless, Heated and Heated Blower

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

*.ppt 11/2/ :48 PM 1

PortaSens ll G AS DETECTOR

Electronic Control Devices The European Product Catalogue 2007

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Cronos -1 Gamma Object / Tool Monitors

NMC Pro System Manager

2.24. Pump Controller 704. Data Sheet

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

TABLE OF CONTENT

INTRUSION DETECTION SYSTEM Section

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Research RF Sputtering Packages

RGC-IR Remote Gas Calibrator for IR400

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Architectural and Engineering Specification for a Perimeter Intrusion Detection System. FiberPatrol-ZR

NEW. EVEN MORE data acquisition and test stand automation

Foxboro Evo Process Automation System

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

CalMod Design-Build Electrification Services

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Transcription:

RADIATION MONITORING SYSTEMS FOR A LIFETIME OF SERVICE Since 1965, General Atomics has been a recognized world leader in the design, manufacture, and support of high quality, extremely reliable radiation monitoring systems for the nuclear industry. Our unmatched technical expertise, support services, and extensive manufacturing and testing capabilities keep systems operating efficiently and safely for a lifetime of service. GENERAL ATOMICS ELECTROMAGNETICS

SYSTEM ASSEMBLIES SAMPLE CONDITIONING SKID Separate particulate and iodine filter sets for each flow path Two prefilters and one sample filter in each set 4π lead shielding enclosures for the high concentration filters Manual filter selection controls located in side enclosure Filter selections can be made locally or remotely Remote control grab sample assembly The Sample Conditioning Skid is located down-stream from the Isokinetic Sample Probe Assembly. Each of the two sample flow paths is provided with two prefilters and one sample filter. The selectable prefilters prevent contamination of the detectors on the Sample Detection Skid by filtering particulates and iodine. The sample filter provides particulates and iodine sample for laboratory analysis. Solenoid valves control the sample flow path by operator request. This configuration allows filters to be changed quickly without affecting the monitor. Filters on the mid/high-range flow path have 4π solid-cast lead shielding enclosures to minimize exposure to personnel. A sample can be collected or a prefilter path selected locally with switches in the electrical enclosure or remotely with switches in the Control Room Display Assembly.

10 CFR 50 APPENDIX B ISO 9001:2008 NQA-1 QA PROGRAM NUPIC CERTIFIED NRC APPROVED VENDOR REGULATORY GUIDE 1.97 SAFETY RELATED, CLASS 1E SAMPLE DETECTION SKID RD-52 Gas Detector for low concentrations RD-72 Dual-Range Gas Detector for mid and high range concentrations 12-decade range 4π lead shielding for detectors & electronics Long half-life integral checksources for each detector Automatic purge and isolation of RD-52 Gas Detector or RD-72 Dual-Range Gas Detector when concentration is out of range Separate flow sensors, flow control valves, and pumps for each sample path The Sample Detection Skid is located down-stream from the Sample Conditioning Skid. It monitors radioactive gas concentrations over a 12-decade range using three radiation detectors. Each of the two flow paths has separate pumps, valves flowmeters, relays, and control switches. The flow through the monitor is automatically controlled by the RM-2000 Digital Radiation Processor to maintain isokinetic sample flow rates from the Isokinetic Sample Probe Assembly. Each detector has a radioactive checksource to verify proper operation, and a 6-inch lead shield to reduce background radiation effects. The low concentration flow path uses the RD-52 Gas Detector which contains a thin plastic scintillation detector. The mid/high concentration flow path uses the RD-72 Dual-Range Gas Detector which has two beta/gamma-sensitive solid-state CdTe detectors (one each for mid-and high-range detection). Range overlap provides continuity of measurement.

SYSTEM ASSEMBLIES RM-2000 DIGITAL RADIATION PROCESSOR 8-channel capability Data acquisition and control - Multiple history files Menu-driven operator interface Application-specific database Local status indication Digital signal processing of analog signals External digital communications Automatic diagnostics/continuous self-test Electronic calibration Multi-channel analyzer Internal 120 Vac power filter Outlet for test instruments The RM-2000 performs data acquisition, analysis and display, as well as monitor control functions, alarm relays, analog outputs, and digital communications. The RM-2000 database, which can be programmed for specific applications by the user, contains the calibration constants for the RD-52 Gas Detector and RD-72 Dual-Range Gas Detector, alarm setpoints, and history files. The RM-2000 is easy to maintain, providing electronically adjustable high voltage power supplies, location-independent circuit cards, and a swing-out card cage for improved accessibility. The RM-2000/CIJB can be located up to 500 ft. from the Sample Detection Skid.

RM-2300 CONTROL ROOM DISPLAY ASSEMBLY Easy menu-driven access to database items Remote control of RM-2000 Radiation Processor Multi-channel, simultaneous display Easy, numeric entry Numerical and graphical display of radiation monitoring data High-resolution 12-bit digital-to-analog converter outputs to plant interface Provides alarm relay outputs The RM-2300 Control Room Display Assembly provides remote control and display for the Wide Range Gas Monitor system. The RM-2300 continuously polls the RM-2000 for the radiation level and operation status. It provides data collection and display, and alarm annunciation for the RM-2000. Additionally, the RM-2300 performs RM-2000 database loading and changing provides 8 voltage analog outputs, and includes 32 relay drivers with programmable and selectable outputs. The RM-2300 also provides a supervisory key lockout switch and full self-diagnostic/testing capability. Custom System Options Available

ASSEMBLY SPECIFICATIONS WRGM SYSTEM SPECIFICATIONS Power/Voltage 120 Vac, 50 to 60 Hz, 15 A nominal at the main power disconnect switch on the Sample Detection Skid which provides power to the Sample Detection and Sample Conditioning Skids - RM-2000 Microprocessor/ CIJB 4.0 A nominal - RM-2300 Control Room Display 2.5 A nominal Operational Range - Pressure - Temperature - Humidity Sample Temperature Environmental Temperature - RD-52 - RD-72 Environmental Humidity - RD-52 - RD-72 Range* *Ranges & MDCs dependent on cosmic background & local fission product background Sensitivity - RD-52 - RD-72 Mid-Range - RD-72 High-Range Sample Pressure Sample Flow Rate - Low Range - Mid/High Range Sample Connections - Low Range - Mid/High Range - Common Return Line - Connecting Lines Overall System Accuracy Atmospheric 39⁰F to 122⁰F (4⁰C to 50⁰ C) To 95% (non-condensing) 120⁰F (49⁰C) maximum at 90% RH; 130⁰F (54⁰C) maximum at 70% RH 39⁰F to 122⁰F (4⁰C to 50⁰ C) 39⁰F to 122⁰F (4⁰C to 50⁰ C) 90% non-condensing 5-95% 10-7 to 10 5 μci/cm 3 (Xe 133 ) with 1 mr/hr background Kr 85 7.19E7 cpm/µci/ml, Xe 133 2.94E7 cpm/µci/ml Kr 85 1.51E4 cpm/µci/ml, Xe 133 1.42E4 cpm/µci/ml Kr 85 58.9 cpm/µci/ml, Xe 133 49.4 cpm/µci/ml 15psig (0.10 MPa) maximum 1.7 ft. 3 /min (802 cm 3 /sec) nominal 0.06 ft. 3 /min (28 cm 3 /sec) nominal 0.5 in. (1.3 cm ) tube fitting 0.25 in. (0.64 cm) tube fitting 0.5 in. (1.3 cm) tube fitting Between Isokinetic Sample Probe Assembly manifold and Sample Conditioning Skid per ANSI N13.1-1969 Meets or exceed U.S. Regulatory Guide 1.97 (Rev.3) Quality Assurance Meets 10 CFR 50, Appendix B; ANSI N45.2 GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS GA.COM/RADIATION-MONITORING-SYSTEMS RMS.INFO@GA.COM Technical descriptions and specifications contained herein provide general product guidelines and are for information purposes only. Information and specifications contained herein are subject to change without notice. All brand names, trademarks and registered trademarks are the property of their respective companies. RMS-WRGM rev B 0505-2016