BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER

Size: px
Start display at page:

Download "BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER"

Transcription

1 quincycompressor.com 701 North Dobson Avenue Bay Minette, AL Phone: Fax: BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER 1. SCOPE The specification outlines the requirements for the design, fabrication and supply of a dual tower, automatic, heat less, pressure swing compressed air or gas dryer completely piped, wired, shop assembled and test run as a single unit. 2. GENERAL REFERENCE SPECIFICATIONS The air/gas dryer system shall be designed, fabricated and assembled in accordance with the applicable sections of the following codes, standards, and specifications: A. ASME Boiler and Pressure Vessel Code Latest Edition, Section VIII, Division 1 of unfired pressure vessels. B. ASME Boiler and Pressure Vessel Code Latest Edition, Section IX (Welding Qualification). C. NEMA Standard governing auto-cycling equipment and electrical components. D. National Electrical Code E. ANSI B31.1 Code for Power Piping F. ANSI B16.5 Code for Forged Steel Flanges. G. ANSI B16.9 & ASTM SA-234 for fittings. H. ANSI B16.3 Class 150 Threaded Iron Fittings. I. Inspection and Test Reports. J. Customer Specification K. ISA Instrument Society of America 3. PERFORMANCE REQUIREMENTS The dryer shall be designed to handle the following operating conditions: Fluid: Compressed Air/Gas Capacity: Flow in SCFM 14.7 PSIA Inlet Pressure 100 PSIG (Normal) Design Pressure: 150 PSIG. (Standard) Inlet Temperature: 70 0 F (Minimum) (120 0 F Maximum) Moisture Content: Saturated Electrical Classification: Nema 4 Power Supply: 115V-PH-60HZ Outlet Dew Point: F PDP 1

2 4. BASIC DESIGN A. Design, materials, construction and performance shall be in accordance with Seller s standard practice. B. The design, materials, and construction shall meet all requirements for drying air at the rate and conditions specified. 5. DESIGN FEATURES A. GENERAL 1. The dryer shall be dual tower, fully automatic regenerative type. 2. The dryer shall be assembled on a heavy-duty steel base. The dryer shall be furnished with all the necessary components, equipment and accessories for continuous, fully automatic operation for drying the incoming air with simultaneous reactivation of the idle desiccant bed. 3. The air dryer system shall be fabricated with dual desiccant chambers. Inlet switching valves shall be 2-way non-lube, diaphragms, pilot air operated, normally open (all models through 3,400 cfm). Air outlet valves shall be soft seated, silent check valves. The purge valves are air operated, normally closed, so that in case of power failure or when the unit is de-energized, both the inlet valves are open and the purge valves are closed to avoid any air loss. High performance switching valves with integrally mounted double acting pilot air cylinders, permanent lubrication and a 5 year valve warranty are available on all models The air dryer assembly shall not use any silicone based Material. The gaskets shall be designed for high temperature service and user friendly. 4. The drying flow is upward and regeneration flow is downward. The upward drying flow helps in retaining the contaminants and any liquid carry over at the bottom of the bed. These contaminants are removed at the time of tower depressurization prior to regeneration. The downward regeneration flow direction allows the tower to be rapidly exhausted without fluidizing the desiccant. The instant depressurization of the desiccant bed helps in stripping the moisture from the desiccant bed. 5. The dryer shall be designed to operate on standard NEMA 10 minute time cycle. This 10 minutes cycle is the time required for the desiccant bed to be in drying service, regenerated and returned to drying service. The Sequence of Operation is divided into: Drying- 5 minutes, Regeneration 4 minutes 20 seconds, Re-pressurizing 40 seconds. The dryer designed to provide lower dew point of -100 F shall use a NEMA 5 minute time cycle. 6. The desiccant used shall be Q SORB an enhanced formula of activated alumina that improves adsorption, reduces channeling, reduces pressure drop, lasts longer than ordinary desiccants and is suitable for the operating conditions and dew point specified. The desiccant fill shall comprise of active buffer desiccant at the top and bottom to safe guard the desiccant from being fluidized, minimize the pressure drop, provide full area reactivation and air/gas distribution. 7. The velocity of the air/gas through the desiccant bed shall be less than that which would disrupt, upset or fluidize the desiccant bed. 8. The desiccant towers shall be supplied with removable stainless steel screen. The screens shall be designed to distribute the air/gas flow evenly through the desiccant bed and disperse the dry purge air/gas for desiccant regeneration. 9. Each desiccant bed shall be supplied with separate desiccant fill and drain ports. 10. Desiccant vessels shall be designed, fabricated, tested and code stamped according to the latest edition of ASME Section VIII, Division I Code for Unfired Pressure Vessels. The desiccant vessels shall be designed with 1/16 corrosion allowance. B. REGENERATION SYSTEM 1. Regeneration of the desiccant shall be carried out by means of diverting 14% of the dry process air/gas. The regeneration flow shall be in the opposite direction to the process drying flow. 2. Regeneration of the spent desiccant in off line tower shall be accomplished at atmospheric pressure. The tower to be reactivated shall be depressurized to ambient conditions by blowing down the tower through the purge valves and exhaust mufflers. The air 2

3 required for desiccant reactivation is supplied from the dry process side. The dry air for desiccant regeneration to be regulated with a ball valve and passed through an orifice for flow control. 3. The dry air at almost atmospheric pressure is passed through the saturated desiccant bed. The dry air releases the moisture from the desiccant and is purged out into the atmosphere through the exhaust mufflers. The regeneration period shall last for 4 minutes and 20 seconds. At this time the purge exhaust valve is closed and the tower is re-pressurized to full line pressure through the re-pressurizing valve. C. DEW POINT PERFORMANCE: Provide the air/gas dryer with constant dew point at switch over. Normal -40 F D. CONTROLS 1. An electrical control panel shall be furnished and mounted on the dryer assembly. The panel shall consist of a digital microprocessor controller to sequence the desiccant tower switch over and regeneration automatically. A user friendly LCD display indicates alarm alerts, and actual sequence time in minutes. A sequence annunciator uses LED s to indicate drying status, regeneration status, alarms, and demand cycle indicator (optional). The digital microprocessor control and all electricals are mounted in a NEMA-4 electrical enclosure. The on/off switch and digital microprocessor user interface are located on the electrical enclosure door. 2. Only dry, filtered air may be used for pilot or control air necessary for the operation of the dryer. 3. In the case of loss of power the air dryer will be placed in the fail-safe mode. Both the inlet valves will fail in the normally open position and the purge valves shall fail in the normally closed position. When the power is restored, the operation shall commence from where it had stopped. 4. The dryer shall be equipped with a re-pressurizing circuit to allow gradual rise of regenerating tower to full line pressure prior to switch over. ELECTRONIC CONTOL PROCESSOR FOR QHD HEATLESS DRYERS 1. INTRODUCTION 1.1. GENERAL The Quincy ECP controller is a microprocessor controlled, seven (7) channel recycling timer with LCD and LED display features SEQUENCE OF OPERATION The sequence of operation is based on a five (5) minute or a ten (10) minute NEMA cycle. For either cycle length, one-half of the total time is for adsorption of moisture from the process gas and one-half is for desiccant regeneration. If power is interrupted, the ECP controller electronically stores the point in the timing cycle at which power was removed. When power is reapplied, timing will resume from that point in the cycle. At all times during operation, the current status of the timing cycle is indicated graphically by the LEDs and textually on the LCD screen. 3

4 2. TECHNICAL INFORMATION 2.1. SPECIFICATIONS Input Power: Frequency: Operating Temperature: Time Delays Type: NEMA Cycle: Protection: Dielectric Strength: Insulation Resistance: Mechanical: 120VAC or 230VAC, Single Phase 50 or 60 Hertz 32 F to 122 F (0 C to 50 C) Digital Integrated Circuitry 10 minutes or 5 minutes Transient protected to IEE 587 Level A 2500Vrms 100 M F minimum Control unit with molded housing and encapsulated circuitry. Remote I/O Module is open circuit board construction FEATURES LCD screen indicating R/L tower drying/regenerating, tower switching, actual sequence time, demand cycle indication (opt.), failure to switch alert (opt.) LED sequence annunciator indicating R/L tower drying/regenerating, demand cycle indicator (opt,), high humidity alarm (opt.), failure to switch alarm (opt.) Timer and setting memory Time cycle advance button 5 or 10 minute NEMA cycle selector 3. MODE OF OPERATION: 3.1. START UP The Electronic Control Processor will start to operate as soon as power is supplied and the unit is turned on. The load outputs will recycle on and off based on a 5 minute or a 10 minute NEMA cycle. The point of the sequence at which the timing starts depends on where the cycle stopped when power was last turned off NEMA CYCLE The ECP Controller can be set to operate in a 5 minute NEMA Cycle or a 10 minute NEMA Cycle. The cycle can be selected via a slide switch at the back of the remote I/O module. 4. INHIBIT FUNCTIONS (OPTIONAL) 4.1. DEW POINT DEMAND SEQUENCE CONTROL The demand cycle inhibit function switch will be operational if there are 5 minutes before the end of the drying cycle and the dew point is below the preset level. During dew point demand cycle all of the timing functions stop. The YELLOW LED on the remote I/O will light up and DEMAND CYCLE will be displayed on LCD. As soon as the dew point reaches the preset dew point level the towers will switch and normal cycle will commence. The dew point demand inhibit function will be disabled if the dew point is above the preset level HIGH HUMIDITY The high humidity inhibit is indicated by a red LED on the remote I/O module. The high humidity relay will energize for remote annunciation. All the normal functions will be maintained. 5. RELAY OUTPUTS (DRY CONTACTS) There are two relay outputs for remote annunciation. The output is normally open and rated for 10 AMPS resistive at 125VAC, 5 AMPS resistive at 30VDC. The outputs are for the failure to switch and high humidity alarms. If one or both inhibits are made, the relays will be energized and the LED on the remote I/O will light up. 4

5 CAUTION: The unit may be damaged by electrostatic discharge. Follow procedures for static sensitive parts when handling, shipping or installing this unit. INSTRUMENTATION The dryer assembly shall include the following instrumentation as minimum. 1. Full size Pressure Relief Valve on each tower. 2. Pressure indicator locally mounted on each tower. 3. Control Power On/Off Switch 4. Electronic Control Processor Operator Interface 5. Pilot air control filter with service valve E. FILTERS (Optional Accessory) 1. Provide Coalescing Filter upstream and Particulate Filter downstream of the air/gas dryer. The coalescing pre-filter shall be rated for 0.3 micron and the particulate after-filter shall be rated for 3.0 micron. 2. The pre-filter shall be supplied with automatic drain with isolation valve and an auxiliary manual drain valve. The after-filter shall be supplied with manual drain valve. 3. Each filter shall be assembled with high differential pressure gauge. 4. OPTION: Single or Dual filters installed on the dryer skid or a separate skid with Isolation and bypass valves for servicing or replacing the filter elements. F. PIPING & FITTINGS Standard dryers are constructed with SA53B, black steel pipe Schedule 40 conforming to ANSI B Pipe fittings are black malleable iron fittings conforming to ASTM A197 specification. The fittings 1/4 to 2 size are Class 150 threaded, designed to conform to ANSI B16.3. All piping and fittings 2-1/2 and larger are butt weld SA234WPB with SA150 slip-on or weld neck flanges conforming to ANSI B31.3. G. ELECTRICAL 1. In the case of power supply over 120V, the panel shall include control transformer with primary and secondary circuit fuses. 2. The controls shall operate on 120 volts, 60 hertz, 1 phase power. 3. Electrical construction shall be in accordance with NEMA area classification and shall be wired in accordance with NEC requirements. 4. All the wiring shall be numbered and end in terminal block. Splicing of the wires shall be avoided. Each terminal shall hold only two wires. 5. Provide the PLC with Master Advance Switch to manually advance through the sequence and help in trouble shooting. 6. Provide dry contacts for all alarm conditions for customer annunciation. A. DIGITAL DEW POINT DEMAND An automatic moisture load control system shall be provided to reduce the total operating cost during periods of low moisture loading and extend the life of the equipment and desiccant resulting in lower operating and desiccant replacement cost. The digital dew point demand control is an energy saver that can extend the drying cycle without purging during periods of lower moisture loads. The dew point demand system offers in on compact package, the utmost in flexibility and accuracy sensing the actual dew point of the outlet air. The hygrometer senses the dew point at the outlet of the dryer at the end of the drying cycle, 5

6 and extends the drying cycle until the preset adjustable dew point set point is reached. During this extended drying cycle, the purge valves are closed and the opposite tower is pressurized and prepared for the drying cycle. The digital dew point demand option reduces purge loss and extends valve life. This option includes an adjustable high humidity alarm set point and a digital dew point display. The system is designed to automatically default into the fixed cycle if the signal from the probe is not received. Digital Dew Point Demand Standard Instrumentation is as follows: Digital dew point display Adjustable set points High Humidity alarm light with dry contact 4-20 ma output signal tracking the dew point This system shall accomplish the following: 1. Sample the moisture content of the air leaving the dryer by means of a moisture sensor. 2. Provide a moisture analyzer with digital dew point display. This will give a visual indication of the actual outlet air dew point performance and operation of the dryer. 3. Initiate the tower switch over only when the outlet moisture content rises to a preset dew point on the analyzer. 4. Control all functions of the dryer so that complete reactivation of the idle tower is accomplished. 5. Provide the dew point analyzer with 4-20 MA Output signal for remote annunciation. The dew point set points should be field adjustable. 6. Provide the dew point analyzer with a second output. This will energize contact for alarm condition if the moisture content of the discharge air reaches an unacceptable level. A light is provided on the control panel for visual indication. 7. In case of the dew point analyzer or moisture sensor malfunction, the sequence should automatically change to the normal cycle. 8. Provide a manual over-ride switch to change the sequence between the normal cycle and demand cycle. 9. The probe shall be protected from normal wear and tear by a rugged stainless steel enclosure and the ceramic sensor shall be protected by a sintered metal guard. Calibration data shall be stored directly in the sensors memory. The instrument shall be equipped with an internal thermistor to compensate for fluctuating temperatures. The probe shall be certifiable and traceable to the National Institute of Standards and Technology. The system shall provide dry contacts for remote alarms and a scaled 4 to 20 ma linear output. Optional RS232 or RS485 communications ports shall be available. B. -94 DEW POINT (Optional) 1. Provide a mixture of molecular sieve desiccant in the drying towers. 6. FINISH AND PAINTING The finishing and painting shall be according to the manufacturer standard procedure. 1. Remove grease, dirt and dust from steel and iron surfaces by cleaning with solvents or inorganic detergents. 2. Remove rust, scales and heavy coatings of paint by wire brushing or sanding. 3. Remove all weld spatters by dipping or grinding. 4. Immediately prime any bare metal 5. Prime all welds as soon as it is cool to prevent any rust formation on the bare metal. 6. Prime all the bare metal with red primer. 7. Finish Paint with standard enamel. 6

7 8. INSPECTION AND TESTING The completed dryer assembly shall be Inspected and tested according to the Inspection and Test Procedures. 1. The air dryer assembly shall be leak tested pneumatically at 1.25 times the normal operating pressure with soap bubble pressure test. 2. The dryer shall be tested at no load through its complete sequence of operation. 3. All the alarm conditions shall be tested for their function. 4. All the control settings shall be tested and recorded. 5. The completed shop test report shall be submitted with the dryer. 9. SHIPMENT The Manufacture shall provide the following minimum for Shipment. 1. All the nozzles shall be plugged or sealed with protective covers. 2. Wrap the Electrical enclosure with polyethylene sheet. 3. Place a small bag of desiccant in the enclosure. 4. Place the Installation, Operation and Maintenance Manual with the shop test report in the Enclosure or tape it on the side. 7

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration INNOVATIVE COMPRESSED AIR SOLUTIONS DESICCANT AIR DRYERS 90-8000 scfm ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration 2100ZHA RELIABLE PERFORMANCE INNOVATIVE DESIGN Before

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

Desiccant Air Dryers Heatless, Heated and Heated Blower

Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... Desiccant Our reliable high strength, non-acidic desiccant provides maximum performance and is easily stored and handled. Environmentally

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com PNEUMATIC PRODUCTS pneumaticproducts-spx.com Externally Heated Desiccant Compressed Air Dryers PHD Series PHD Series Dryers Reduce Purge Air Energy Costs PHD Series Dryers Reduce Purge Air Energy Costs

More information

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS Value and Performance Through Advanced Technology ABOUT PNEUMATIC PRODUCTS PPC s Heritage Since 1946, PPC has been recognized

More information

Ingersoll Rand. Heat-Of-Compression Air Dryers

Ingersoll Rand. Heat-Of-Compression Air Dryers Heat-Of-Compression Air Dryers Air Quality Solutions by Heat-of-compression (HOC) dryers are dual-tower, desiccant designs. The HOC dryer is the most energy-efficient dryer available. It recovers the heat

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION 2099 Ninth Avenue Ronkonkoma, NY 11779 www.vacuuminst.com Smart Charge II An advanced gas backfill and evacuation system with built-in gross leak test.

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR Atlas Copco Compressed air dryers CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR Why Quality Air? When the air that surrounds us is compressed, its vapour and particle concentration increases

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry CAMS Combustion Airflow Management System Proven solutions for a tough industry CAMS TM Combustion Airflow Management System Product Description The Air Monitor Power CAMS TM Combustion Airflow Management

More information

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00

D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00 SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

Sanitary Type Electronic Flow Switches

Sanitary Type Electronic Flow Switches Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

REFRIGERATED COMPRESSED AIR DRYERS

REFRIGERATED COMPRESSED AIR DRYERS INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING OPERATION 75 2,400 scfm Capacity Models STAINLESS STEEL HEAT EXCHANGERS www.zeks.com Compressed

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

Automatic Self-Cleaning Strainers

Automatic Self-Cleaning Strainers Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning

More information

HELPFUL HINTS ON PREPARING COMPRESSED AIR

HELPFUL HINTS ON PREPARING COMPRESSED AIR HELPFUL HINTS ON PREPARING COMPRESSED AIR Introduction An efficient compressed air system does not just happen, it is the product of good planning to insure minimum pressure loss in the distribution system

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Description of Thermal Oxidizers

Description of Thermal Oxidizers Description of Thermal Oxidizers NESTEC, Inc. is a full service equipment supplier specializing in solutions for plant emission problems. The benefit in working with NESTEC, Inc. is we bring 25+ years

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Meeting Your Compressed Air Treatment Needs

Meeting Your Compressed Air Treatment Needs Compressed Air Treatment Guide Meeting Your Compressed Air Treatment Needs How to Select the Right Equipment for Your Application Provided as a Service by Kaeser Compressors, Inc. Typical Air Treatment

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

Pro Dry Heatless dessiccant compressed air dryers

Pro Dry Heatless dessiccant compressed air dryers Pro Dry Heatless dessiccant compressed air dryers Features Each Pro Dry unit has been designed to suit a multitude of requirements and is suitable for installation in many countries. The Pro Dry range

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless

More information

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Compressed Air and Gas Drying

Compressed Air and Gas Drying Compressed Air and Gas Drying CONTENTS I. Why Do Compressed Air And Gas Need Drying? 1 II. Applications Requiring Clean, Dry Air 1 III. How To Measure Moisture Content 2 IV. Selecting The Right Dryer 3

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI). SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

DHA & DBA Series. Heat Reactivated Desiccant Dryers

DHA & DBA Series. Heat Reactivated Desiccant Dryers DHA & DBA Series Heat Reactivated Desiccant Dryers 02 12 DHA & DBA series externally heated and blower purge desiccant air dryers Parker domnick hunter Externally Heated and Blower Purge Desiccant Air

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

How To Clean Up A Reactor Water Cleanup

How To Clean Up A Reactor Water Cleanup General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

COATING & WRAPPING OF UNDERGROUND PIPING

COATING & WRAPPING OF UNDERGROUND PIPING CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification

More information

Water Tec of Tucson Water Systems

Water Tec of Tucson Water Systems Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

RMF Engineering 23 05 23

RMF Engineering 23 05 23 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

FAQ s on Siemens Magmeters

FAQ s on Siemens Magmeters FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables

More information

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400 Technical ata Sheet Page 1 of 6 igh Pressure ryer -MS 0055 to 0870, PN 100 to PN 400 igh pressure adsorption dryer, heatless regenerating, pre-, and afterfilter included Compressed air is lead through

More information

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output 133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance (200-1000 scfm models)

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance (200-1000 scfm models) INNOVATIVE COMPRESSE AIR SOLUTIONS COMPRESSE AIR SOLUTIONS eatsink TRUE-CYCLING REFRIGERATE COMPRESSE AIR RYERS 150 2,400 SCFM Independently Verified Performance (200-1000 scfm models) Stainless Steel

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

Mechanical Installation

Mechanical Installation Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s

More information

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 WARNING 12-32 VDC

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 WARNING 12-32 VDC SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR 032-044-000 032-045-000 } 12-32 VDC Specifications 032-044-000 and 032-045-000 WARNING Hazardous voltage. This Leak Detector is an electrical device.

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information