Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology, the system more stable, safer. Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer. The system's APP integrated the IP camera to realize the video record, send pictures to user s Email when alarming. 1 slave wired relay output, support alarm output, APP control output. 20 slaves wireless smart home control to switch light, and other home appliances. Set up to 4 scenes, 8 slaves relay per scene. Wireless encode function, support 10 keyfobs/keypads, 24 wireless zones, 4 wired zones & 4 RFID zone. Zone name/content could be edited by yourself, and set alarm delay or not. APP push message including alarm zone and sensor s name when alarming. APP check the system in real-time: AC power OK or not; system Arm or Disarm; sensor low voltage or not; sensor connect to panel or not; the zone has accessories or not. Check the system's status clearly in time. Answer alarming calls & Remotely make call to the alarm panel ( with voice prompt ) to start monitoring, voice intercom, talk back, arm/disarm. Answer calls like a cell phone. Support wired and wireless siren. Support CID protocol. Factory reset. 1
1. Power supply: input AC=100 ~ 240V, output DC =12V 2. Static current: <50mA (when not in charging, excluding wired detectors) 3. Alarm current: <120mA (excluding wired siren) 4. GSM transmission power: 2W 5. WIFI frequency: 2.4G, built-in wireless internet protocol IEEE802.11b/g and TCP/IP protocol stack 6. WIFI receiving sensitivity: -86dbm; Emitting power: 18dbm 7. GSM frequency: 850/900/1800/1900 8. Backup battery: 3.7V/1200MA/H; Standby: 12 hours or more; Charge: 12 hours full 9. Wireless receiving distance: > 100 meters (open space) 10. Wireless transmission distance: > 100 meters (open space) 11. Work condition: Temp -10 º C ~ 70 º C, RH 5% ~ 95% 2
3
4
Activate Away Arm On keypad, click to activate Away Arm. Remotely via SMS, send SMS content: xxxx+a0$. Remotely via phone, make phone call to alarm system, according to voice prompt: enter the user code: xxxx#, press 1 to activate Away Arm. Activate Home Arm On keypad, click to activate the Home Arm. Remotely via SMS, send SMS content: xxxx+a1$. Remotely via phone, make phone call to alarm system, according to voice prompt: enter the user code: xxxx#, press 2 to activate Home Arm. Disarm Remotely via SMS or APP, send SMS content: xxxx+a2$. Remotely via phone, make phone call to alarm system, according to voice prompt: enter the user code: xxxx#, press 3 to Disarm. Notice "xxxx" is the current user code, default user code is "1111". The system works with separate wireless LED/LCD keypads, for activate and deactivate operation, please refer to manual of wireless keypad. 5
Phone calls Speed alarm Press SOS for 2 seconds, the panel will alarm and transfer alarming message. Phone Call When you make call to the panel remotely, the LED light on the panel will keep flashing. Then you can press " to answer the phone call like a phone. Speed Dial When the System is on standby, press for 2 seconds on the panel, then the panel will call the phone number which you set previously in the system. This function is much helpful for the elderly and children. Scenes When the system is on standby, press to activate the scene, the LED light will be turned on. Then press a group scene in 4 scenes which you choose, the light off means success to turn on the scene. 6
WIFI setting 1. Find the X8 s WIFI: Turn on X8, keep pressing the setting key for 10s, when there is long Beep, Beep, you will find the X8 s WIFI SerialWIFI_B7CF (each X8 has its own WIFI, this one is only for a sample.) on your smart phone. Join in, the default password is 12345678. 7
2. Open the browser on the phone, enter 192.168.16.254/p2p.asp. Some browsers will appear as following pi ctures, the user name & password are both admin. 3. Log in, it will show the X8 s UUID & PASSWORD. Please write them down. They are the remote user name & password, you will need to enter them later. 8
4. Then enter 192.168.16.254 in your browser, and follow the steps as below: NOTE: Please scan and choose the WIFI you usually use, and then enter the password of your chosen WIFI. 9
The system could be set by APP or SMS command APP download for free: Download the APP X8 Alarm System from Google Play or App Store. Add APP account After finish APP installing, please open it, click Add host account, follow the tips and enter the content, then click OK to save it. 10
Arm/Disarm Click the registered account, enter APP interface to set Away arm, Stay arm, Disarm and other operations as following pictures. Home Automation/Scenes Click into Home Automation interface, you can turn on/off any slave relay switch control for your home appliance. Each slave relay switch name could be changed as you want. For example, click The X(1.2.3...) CH to modify the name as following pictures. PS. Add/delete Scene: On Android APP, keep pressing Scene for 5s to add, 10s to delete. Maximum 8 slaves per Scene. On IOS APP: just click it. REMARK: APP operation will be not available until the APP connect to the system and detect the system successfully (the corresponding LED will light on). If fail to connect/detect the system, please check if the system or smart phone connecting the WIFI or not, or please reenter the APP. 11
Add IP camera Click to the IPC interface, please register an Email (any one you have) first. After register ok, please add the IPC according to the IPC manual (Only the IPC which is offered from us can work with the system). Alarm phone & SMS number settings Click into System setting, choose into Alarm phone number interface. Click or to choose alarming type, phone call or SMS, then click OK to save it. 12
Built-in/external siren setting Click into System setting, and click into Alarm voice interface, choose ON or OFF, click OK to save it as the following pictures. Arm/Alarm delay Click into System setting, then click into Arm/Alarm delay interface. Please make sure that delay time is 2 numbers, eg: 2s, enter 02, maximum time is 60s. Click OK to save it. 13
SMS Alert Settings Click " " into System setting, click into the interface. Choose ON to turn on SMS alert function and enter a phone number to send and receive the SMS alert notifications ( if two way check function ON, it is only valid when connect a two-way detector). Click OK to save it. Alarm Zone Program & Delete Click " " into the System Setting, click " " into Zone attribution interface. Choose a zone number as you want, touch learning, the system will beep once. That means the panel in programming status, trigger accessories twice. The panel will beep, beep twice, that means programming success. Able to DIY Alarming content as you want in the input box for each zone. Meanwhile, press " " to set zone alarm delay individually (Only 09~24 zones have alarm delay function). Remote control/ wireless keyboard only can be programmed into "Keyfob zone". 14
Family Phone Number Setting Click into System setting, choose into the interface. Please enter the phone number for the elderly and children to speed dial. ( press the shortcut key on the panel, default to call the first phone number. ) Modify User Code Click into System setting, slide the interface left/right, then click into the interface, please enter the password as you want, 4 numbers needed. ( password A for remote phone call, password B for SMS, password C for the APP operation to the panel. The factory default password for A/B/C, all are 1111.) 15
Factory Reset Click into System setting interface, slide the interface left/right, click to choose YES/NO. CID Center Setting Click into System setting, slide the interface left/right, click into the interface. Please enter the CMS number and panel user ID as you want. Meanwhile, choose ON/OFF to upload arm/disarm to center or not. 16
Receiving Alarm SMS Once an alarm occurs, the system will send SMS as long as user choose for alarm SMS notification. The system will send SMS with below content: (0001)Alarm System: 11 Zone Door Sensor Alarming Receiving Alarm Phone Call Once an alarm occurs, the system will make phone call as long as user choose for alarm call notification. The system support remotely control via phone call, including Away Arm/Stay Arm/Disarm, onsite voice monitoring, listen voice message, talk back, two-way intercom, recording memo. 17
When pickup alarm phone call, you will hear the siren sound, after the replay, you can: Press "1" on the phone to Away Arm (It will hang up immediately, system will be Away Armed) Press "2" on the phone to Stay Arm (It will hang up immediately, system will be Stay Armed) Press "3" on the phone to Disarm (It will hang up immediately, system will be Disarmed) Press "4" on the phone to listen onsite voice (It will hang up, after 20 seconds delay) Press "5" on the phone to listen voice memo Press "6" on the phone to talk back (fixed phone number doesn't support this function) Press "7" on the phone to record voice memo (Maximum 10 seconds, except fixed phone number) Press "8" on the phone to begin two-way intercom (except fixed phone number) Press"*" on the phone for alarm confirmation, it will hang up, stop to dial phone call 18
Click enter to System setting interface, sliding the interface to left/right, click to Zone attribution interface, choose keyfob Zone, press enroll, panel will beep once, that means the panel are dealing with enrolling, then press arm/disarm on keyfob twice, you will hear the panel beep twice, then enroll success. Press delete to clear away all the sensors in the zone. 19
Click into system setting, slide the interface left/right, click to Zone attribution interface, choose the zone as you want for door sensor, press enroll, the panel will beep once, that means the panel is on enrolling status, then trigger the door senor twice, the panel will beep twice, that means enroll success. Press delete to clear away all the sensors in the zone. (Usually the door sensors are enrolled into 09`16 zone.) 20
Installation Remove the insulating protect on battery. Mount the transmitter on the door frame and the magnet on the door Make sure that the magnet is always on the right side of the transmitter. Make sure that the magnet will not be more than 1 cm from the transmitter. Attach the transmitter and the magnet with double-sided tape or the screw. Avoid placing the detector in areas with large-metallic structures or electrical installations such as boiler area or counters Technical Information Working voltage: 1.5V LR6 Static current: 30 μa Alarm current: 40mA Emitting frequency: 433MHz /(868MHz optional) Transmission distance: 100 m (Open space) Lifespan of battery: 12 months Notice: The door sensor in the package may differ from manual. The specification will change, when use different model of wireless door sensors. 21
Introduction PIR motion sensor is one of common intrusion sensor for instruction detection. It with advantages of large space protection, lowest energy consumption. It detects infrared energy changes which is caused by movement of human. Click into system setting interface, slide the interface left/right, click to Zone attribution interface, choose the zone as you want for PIR, press enroll, the panel will beep once, that means the panel is on enrolling status, then trigger the PIR twice, the panel will beep twice, that means enroll success. Press delete to clear away all the sensors in the zone. (Usually the PIRs are enrolled into 17`24 zone.) 22
Installation Due to the wide coverage angle and the swivel bracket, the motion sensor can easily be installed: Indoor environment only! Wall mounted on the wall and sensor points to entry point of doors Wall mounted on corridor to detect movement Technical Information Working voltage: 2x1.5V LR6 Static current: 50 μa Alarm current: 9.5mA Detection angle: 110 Detection distance: 12 m Emitting frequency: 433MHz /(868MHz optional) Transmission distance: 100 m (Open space) Lifespan of battery: 12 months Notice: The PIR sensor in the package may differ from manual. The specification will change, when use different model of wireless PIR sensor. 23
Notice: [Emergency Zone] means fire, panic alarms, which are belong to emergency zone. It will trigger the alarm system, even the system in disarm status. [Perimeter Zone] means perimeter protection, which is belong to perimeter zone. It will work when alarm system in both Away Arm and Home Arm modes. [Motion Zone] means interior protection, which is belong to motion zone. The sensors in this zone will be activated when system is in Away Arm mode, but will be de-activated, when system in Home Arm/Stay Arm mode. Default zone number for sensor and keyfob to a standard alarm kit as below: 24
Notice: Hardwired zone number from 25~28. All hardwired zones are disabled/de-activated. If you want to use the hardwired zones, you need go to [Zone attribute] to enable them. EOL resistor must be connected to hardwired sensor for zone protection, it can make hardwired sensors work properly. "A1" means wired zone, "V1" means DC power (either from alarm panel or separate power supply) Maintenance and Care This alarm system is a Hi-Tech product with outstanding design and sophisticated technology, and shall be carefully. To make the alarm to operate for a long term stably and to prolong the service life, it's recommended that: Try to put the alarm panel in a dry and well-ventilated location Do not put the alarm panel and any wireless sensors in too cold, too hot or dusty places to prevent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting. Do not put the alarm panel and any wireless sensors in low and too exposed places to prevent children from touching them or the thieves from finding them Regular testing is necessary for finding and resolving problems in time. Regularly check the batteries in all wireless sensors. To ensure normal operations of the system, replace with new batteries whenever you feel that a sensor is not detecting properly. 25
26