Inverter/Charger. PowerWalker Inverter 700 PSW PowerWalker Inverter 700 PSW/FR PowerWalker Inverter 1200 PSW PowerWalker Inverter 1200 PSW/FR



Similar documents
User s Manual AURORA 1.2K/2.2K

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

User s Manual Before using the inverter, you need to read and save the safety instructions.

How To Use A Power Supply Unit (Upu)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Online UPS. PowerWalker VFI 1000R/1U

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User Manual 1K/2K/3K Online UPS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

USER MANUAL Online UPS 1K/2K/3K Rack

4KVA/5KVA Parallel Installation Guide

Back-UPS Pro 1300/1500 Installation and Operation

Axpert MKS-4000/KS-5000 Service manual. Axpert MKS Charger/ Inverter. Service manual

Installation and Operation Back-UPS 1250, 1300, 1500

USER MANUAL Online UPS 6K/10K RACK

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Line Interactive UPS

TruPower-Portable-500W. Solar Starter kit

10000HXL31/15000HXL31/20000HXL31

USER MANUAL Online UPS 1K/2K/3K

INSTALLATION & SERVICE MANUAL. Display Panel

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Inverter / Charger Installation General Operations and AC and DC Connections

3000W Power Inverter

Model #: SMART2200CRMXL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

BB800 Off-Grid Solar System

MAJORSINE Power Inverter

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Home Solar Kit Owner s Manual. Model: HS

Battery Power Inverters

12 Volt 30 Amp Digital Solar Charge Controller

Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply

ST Series POWER SUPPLIES USER INSTRUCTIONS

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

750 WATT Power Inverter

PSC-A5 Solar Charge Controller Manual

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

EKOS Cart. Instructions for Use

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

700 VA VA UPS. User s and Installation Manual. EMC Statements. FCC Part 15 ICES-003

Instructions & Safety Information Models A220-20D and A220-20L Version 2

EC450 Power Control System

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

How To Use A Power Supply Unit (Upland)

Home Solar Kit Owner s Manual. Model: HS

HM-W536 Install Guide

350, 500, 650 and 1000 MODELS

BC Pro UPS System Standby UPS System

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Internet Office UPS System Standby UPS for PCs, workstations and more

TMS TANK MANAGEMENT SYSTEM

VLT Series 300 Watt True Sine Wave Inverter

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Best 610 Installation and Operation Manual. Single-phase Input and Output B U and B610010KU Models

Solar Controller / Battery Charger User s Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Delta UPS - Amplon Family. User Manual. E Series, Single Phase 1/2/3 kva. The power behind competitiveness ON OFF ON LINE

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

QUICK PROBLEM SOLVING GUIDE

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Assembled in Florida, USA.

YSmart Technology Co.,Ltd

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

instabus KNX / EIB System System E F G H

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Specification Requirements DBL 700MX and 1000MX Series UPS

Thyristor-controlled power supplies and battery chargers

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

1500 WATT POWER INVERTER

Transcription:

Inverter/Charger PowerWalker Inverter 700 PSW PowerWalker Inverter 700 PSW/FR PowerWalker Inverter 1200 PSW PowerWalker Inverter 1200 PSW/FR Quick Start Guide

1. Introduction This robust inverter is designed to power your home appliances or precious electronics. It also can accept wide input voltage to generate stable and pure power source to power downstream AC loads. Based on different types of loads, this inverter can provide pure and stable power either to house appliances or to sensitive personal computers via selectable operation modes. It is a brilliant choice for home owners or small office users in the unstable power area. PowerWalker Inverter 700-1200 PSW (FR) series provides a variety of features: Pure sine wave inverter Selectable input voltage range for home appliances and personal computers Seletable charging current Auto restart while AC is recovering Overload and short circuit protection Generators & Computer-related devices compatible Smart battery charger design for optimized battery performance Cold start function 2. Package Contents You should have received the following items inside of package: Inverter Unit Quick Start Guide 1

3. Product Overview Front Panel: Power switch Display indication (please see the Operation section for the details) Back Panel: Input voltage range selector AC input Input breaker External battery connector Charge current selector Output receptacles French Schuko 2

4. Installation NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. I:Connect External Battery Step 1- Install a DC Breaker in a positive battery line. The rating of the DC Breaker must be at least 60Amp for 700VA model and 100A for 1200VA model to guarantee safe operation without interruption. Keep the DC breaker off (Refer to Right fig) Step 2- Connect battery cables to the external batteries. To have better performance, the DC breaker recommended battery capacity is 100Ah 200 Ah. Following battery polarity guide printed near the battery terminal to connect external batteries! RED cable to the positive terminal (+); BLACK cable to the negative terminal (-) Fig. 1 Note: For the user operation safety, we strongly recommend that you should use tapes to isolate the battery terminals before you start to operate the unit. When connecting to external batteries, do not cause any short circuits. 1) Single battery connection (Refer to Fig. 1): When using a single battery, its voltage must be equal to the Nominal DC Voltage of the unit. II: Multiple batteries in series connection (Refer to Right fig) All batteries must be equal in voltage and amp hour capacity. The sum of their voltages must be equal to the nominal DC Voltage of the unit. Note: when connecting batteries in series connection, it s necessary to use battery wires at AWG#8 or above. II: Multiple batteries in parallel connection (Refer to Right fig): Each battery's voltage must be equal to the Nominal DC Voltage of the unit. Note: when connecting batteries in parallel connection, it s necessary to use battery wires at AWG#10 or above. Step 3- Make sure to connect the polarity of battery side and the unit correctly. Positive pole (Red) of battery to the positive terminal (+)of the unit. Negative pole (Black) of battery to the negative terminal (-) of the unit. Step 4- Take the DC breaker on. Connect to Utility and Charge Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected external battery even though the unit is off. 3

5. Operation Power On/Off Once the inverter has been properly installed, press the power switch to turn on the unit. The unit will work automatically. When press the power switch again, the unit will be turned off. WARNING! The unit may have output power when connected to the utility, even though it is powered off. To completely cut off the output power, please switch off the unit and disconnect the unit from the utility. Input Voltage Range Selector a). 170V-280V : setting for precious electronic devices If you select this mode, the unit's input utility range will be 170~280VAC as normal home UPS. If the utility is higher or lower than this range, the unit will transfer to inverter mode automatically. And you can connect the computer systems or other precision home equipment when you select this operation mode. b). 90V-280V : setting for home appliances If you select this mode, the unit's input utility range will be extended to 90~280VAC. If the utility is higher or lower than this range, the unit will transfer to inverter mode automatically. So, you can connect the home equipments, such as light bulb, fluorescent tube, fan, or TV on this mode. Caution!! If you select the 90V-280V mode and connect the computer to the output of the unit, the computer may reboot if the input voltage is too low to be accepted. Charging Current Selector a) High: setting battery charging current at 20A for 1.2KVA, 15A for 700VA b) Low: setting battery charging current at 10A 4

LCD Display & Audible Alarm Status LCD Display Audible Alarm Line mode Line mode with charging battery. and flashes Battery mode Off Off Off Off-mode charging Fault mode Battery weak at battery mode. The unit is waning of overload. Power limitation warning in Line mode Fan is locked Battery is over charged and flashes Fault code will be displayed. Fan is locked: F01 Over temperature: F02 Battery voltage is too high: F03 Output short circuited or Over temperature: F05 Output voltage is abnormal: F06 Over load time out: F07 Bus voltage is too high: F08 Bus soft start fail Main relay failed led: F09 Main relay failed: F11 The mark second The mark second. will flash every will flash every The mark will flash every second. Beep three times every second Beep once every 1second Off Beep Continuously sounding. The unit will shut down after it s in fault mode for 15 seconds. Beep once every 1 second Beep once every 0.5 second Beep twice every 3 seconds Load level indicator: Battery capacity indicator: Display Load Level Display Battery Capacity 75%~100% 75%~100% 50%~75% 50%~75% 25%~50% 25%~50% 0%~25% 0%~25% 5

7. Trouble Shooting Use the table below to solve minor problems. Problem LCD/ Buzzer Explanation / Possible cause Overload error. The Fault code 07. inverter is loaded with more than 110% load and time is up Buzzer beeps continuously Mains exist but the unit works in battery mode. Unit shuts down automatically during startup process. Fault code 05. Fault code 02. Fault code 03. Output short circuited. Temperature of internal converter component is over 120 C. Internal Inverter component over 100 C Battery is over charged. The battery voltage is too high. What to do Reduce the connected load by switching off some equipment. Check if wiring is connected well and remove abnormal load. Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. Return to repair center. Check if spec and quantity of batteries are meet requirements. Fault code 01. Fan fault Replace the fan. Fault code 06. Fault code 08. Input voltage is displayed as 0 on the LCD The mark on or flash LCD and buzzer will be active for 3 seconds and then complete off. Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) Internal components failed. Input protector is tripped Insufficient quality of AC power (Shore or Generator) The battery voltage is too low (<1.91V/Cell) 1. Reduce the connected load. 2. Return to repair center Return to repair center Check if AC breaker is tripped and AC wiring is connected well. 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well, or check if input voltage range setting is correct (UPS Appliance) 1. Re-charge battery. 2. Replace battery. 6

No response after power on. When the unit is turned on, internal relay is switched on and off repeatedly. Input circuit breaker acted and no output voltage on terminal but the LCD display show the normal output voltage No indication. LCD display flashing. LCD display is normal 1. The battery voltage is far too low. (<1.4V/Cell) 2. Battery polarity is connected reversed. Battery is disconnected. The relay had been damaged during the AC short circuit 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. Check if battery wires are connected well. Return to repair center. If there is any abnormal situations occur, which doesn't list above, please call the service people immediately for professional examine. 6. Specifications MODEL Inverter 700 PSW Inverter 700 PSW/FR Inverter 1200 PSW Inverter 1200 PSW/FR CAPACITY 700VA/500W 1200VA/840W INPUT Voltage 230VAC Voltage Range 170-280 VAC (For personal computer); 90-280 VAC (For home appliances) OUTPUT Voltage Regulation (Batt. Mode) 230VAC ± 5 % Transfer Time 10ms typical (For personal computer); 20ms typical (For home appliances) Waveform Pure Sine Wave BATTERY Battery Voltage 12 VDC Floating Charge Voltage 13.5 VDC Maximum Charge Current 10/15Amp 10/20Amp Recommended Battery Capacity 100 Ah 200 Ah PHYSICAL Dimension(DxWxH) mm 289 x 290 x 127 Net Weight (kgs) 4.5 4.8 7