IT S OUR AIM TO GET YOU A PASS FIRST TIME!



Similar documents
Energy Company Obligation (ECO): Technical Monitoring Questions

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Manual lifting and handling

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

plumbing products guide

Composite Panel Firewall Systems

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Avoiding Air Barrier Pitfalls

WALLS Three common wall types are described below, with their insulation solutions.

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

2014 British Columbia Building Code Changes

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Preventing Ice Dams on Roofs

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Response, Reliability and Results in the delivery of leak detection services

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Certification: Building Plans Examiner. Exam ID: B3

Repair of Spalling and Leaking Clay Brick Building Walls

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

TGD L Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

TOP 10 NOISE CONTROL TECHNIQUES

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Building Condition Assessment Report

Energy Efficient Windows

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Sports Buildings: budget costs for the Flood Relief Fund

Residential Inspection Guidelines

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Multi-layer Insulation Blanket for Roofs

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May

FIRE RATED GLAZING System Guide

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Bituminous Sheet Flat Roofs: Their repair and maintenance

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Inspecting to a higher standard.

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

Homeowner s Handbook

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Comment Form on Proposed Gut Rehabilitation Alternatives

Services Enclosures and Protected Shafts - Maintaining Compartmentation

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

- 5 - Table1. Maximum Compartment Volumes

Building Code Clarifications - 7. Fire Resistance

Hanson Building Products. precast basement solutions

If stepping is required, step at 180mm as seen in this picture.

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Water Damage & Repair

Rockwool Flexi Insulation Application Guide

Module 3.7. Thermal bridging

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

sound reduction systems for commercial, educational and industrial environments

Loss Prevention Standard

3 IN 1 BATHROOM HEATER

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

2009 IECC Update. Scope. Content. International Energy Conservation Code

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

What you need to know about concrete block basement construction.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

ASBESTOS CONTAINING MATERIALS POLICY

Excerpts from the Canadian National Building Code (NBC)

Decree of the Ministry of the Environment on fire safety of ventilation systems

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Rev Code of Practice. SIP Technology.

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Action required (Please tick) If you answered YES, record Action Points at STEP 4

LAYING BLOCK AND BRICK

THE IMPACT OF ENERGY EFFICIENT REFURBISHMENT ON THE AIRTIGHTNESS IN ENGLISH DWELLINGS

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Chapter 3 Pre-Installation, Foundations and Piers

State of Connecticut Department of Public Health RADON PROGRAM

Asbestos in the home. for you - for your community - not for profit

Gramercy Place Condo Association, Inc.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Installation Instructions

LEGISLATIVE GUIDANCE NOTES Refurbishment/Demolition

PB301 July Lightweight Building Solutions. Bushfire Protection.

Management Consultancy Training. Asbestos Materials. Residential Guide

How To Make A House Safe

The WANZ Guide to Window Installation

Housing Services Guidance for tackling condensation, damp and mould in your home

Transcription:

APT AIR PRESSURE TESTING LTD Regional Office: 36 Mayfield Road, Luton, Bedfordshire, LU2 8AP Tel: 07967 233836 Fax: 01582 896709 Offices in London, Luton and Cardiff www.airpressuretesting.net IT S OUR AIM TO GET YOU A PASS FIRST TIME! Dear Sirs, I would like to take this opportunity to introduce our company to you and explain the services we are able to offer. APT is an independent company, formed by two directors, who have a vast amount of experience in the Construction Industry. We have extensive knowledge regarding the way different materials and construction methods can influence the results of an Air Pressure Test. Ultimately, we understand the importance of constructing an air tight building envelope that has a high thermal performance and complies with Acoustic Regulations (part E).The services we offer are: Air Leakage Testing Airborne and Impact Sound Testing Construction Phase Consultancy Infra-Red Thermographic Surveys Fire Enclosure Integrity Testing Background Noise Surveys and Noise Assessments for Planning Applications 1. Air Leakage Testing Air Testing is the simplest and most popular method used in the construction industry to confirm compliance with Part L of the Building Regulations. The air leakage test is simply a test of the building fabric integrity. Draughts and heat loss will occur wherever there is a hole or gap in the building envelope. As many people are aware, since April 2006 all new commercial buildings have been required to be tested for Air Permeability, in order to comply with Part L2 of the Building Regulations. Testing to dwellings under part L1 (April 2006) has also been made part of the regulations. A representative sample (1 of or a minimum of 10%) of each different house or flat type needs to be tested on each site. (Flats on different floors are classed as being different types) We provide a personal, helpful, efficient and cost effective service to our clients. Using the latest high power, portable door fans systems, we offer air leakage testing to all building types, ranging from small rooms, flats & houses to office blocks & large distribution warehouses in accordance with the ATTMA Technical Standard 1. Our fan systems are compact, discreet and fit simply into a personnel door. The system can easily be transported through areas of limited access or up to high level areas. It is for this reason that many companies working in busy city centres utilise our expertise and equipment. We are able to

APT AIR PRESSURE TESTING LTD Regional Office: 36 Mayfield Road, Luton, Bedfordshire, LU2 8AP Tel: 07967 233836 Fax: 01582 896709 Offices in London, Luton and Cardiff www.airpressuretesting.net eliminate the site disruption caused by the larger trailer type testing equipment. Work can also continue inside the building whilst the air leakage test is being carried out. In the event of a building failing an air test we then offer smoke testing, which highlights the areas of leakage in the building fabric. We can then undertake a full written and photographic survey as reference for your site management and relevant subcontractors. We will also offer FREE advice on the best method to seal any leaking areas. The main benefits of this are: Air leakage is quickly identified in the event of a test failure Remedial works can start straight away Practical completion can be achieved more quickly 2. Acoustic Testing Recent changes to the Building Regulations 2000 mean that many new dwellings and conversions require sound insulation tests to demonstrate compliance with the airborne and impact sound insulation criteria given in Approved Document E (ADE). APT can perform these at relatively short notice for any sized development, from two-flat conversions up to hundreds of flats. 3. Construction Phase Consultancy APT can undertake an office based review of the architect and envelope subcontractors detail drawings will be undertaken to identify and comment upon any areas which require further consideration/upgrading, by the design team with respect to air tightness. Where appropriate we will suggest means of achieving acceptable air tightness at critical junctions. We at APT pride our selves on our practical hands on approach during building construction and we prefer to be involved as practically possible during this stage. We undertake periodic site visits to inspect the building envelope assembly as it is constructed and provide both written and photographic reports to enable any further works / remedial works deemed necessary to be accurately targeted.

APT AIR PRESSURE TESTING LTD Regional Office: 36 Mayfield Road, Luton, Bedfordshire, LU2 8AP Tel: 07967 233836 Fax: 01582 896709 Offices in London, Luton and Cardiff www.airpressuretesting.net 4. Thermographic Surveys Infra-Red Thermographic surveys can be undertaken to provide a qualitative assessment of the thermal performance of components through the whole building envelopes, and identifies missing or misplaced insulation, wet insulation, severe cold bridging, air leakage paths, etc. Thermographic surveys on whole buildings can be used to prove compliance with the continuity of thermal insulation requirements of part L of the building regulations. The main benefits of these surveys when used in association with leakage testing are: Quick inspection Results shown clearly in pictures Shows thermal insulation defects Can be used to show the efficiency of heating and cooling installations 5. Fire Enclosure Testing Enclosures protected by gaseous fire suppression systems should be tested for air-tightness upon commissioning of the system and then again when any modifications are made within the enclosure or annually. This is critical to ensure that the system will work effectively when activated; too much air-leakage will result in the concentration of the fire suppressant agent falling too quickly, which could cause an extinguished fire to re ignite. Air Pressure Testing provides the necessary Room Integrity Testing to the required NFPA 2001. We have extensive experience in testing all types and sizes of enclosure, from server rooms in offices to hospital intensive care units. In each case we carry out the necessary volumetric calculations prior to the test and use calibrated test fan systems along with laptops running complaint CA2001 software to determine results immediately upon completion of test. We subsequently provide full reports, incorporating all necessary data test information and certification, usually within a few days of the test. This will ensure that you have all of the required information to undertake accurate remedial works. In the event of an enclosure test failure we then offer smoke testing, which highlights the areas of leakage in the building fabric. We can then undertake a full written and photographic survey for accurate reference for your site management and relevant subcontractors. We will also offer FREE advice on the best method to seal any leaking areas. The main benefits of this are: Air leakage areas are is quickly identified in the event of a enclosure test failure Remedial works can start straight away Practical completion can be achieved more quickly

APT - 4-6. Background Noise Surveys & Noise Assessments for Planning Applications Externally mounted plant such as Air Conditioning units, will generally require planning permission from the local authority, particularly where there are residential units nearby. The Planning Application will require a 24 hour Background Noise Level Survey to be undertaken and an assessment of the noise level from the newly installed plant at the nearest residential window. APT can undertake both the 24 hour Background Noise Survey and Noise Assessment using the latest sound analysers and noise mapping software. Our Promise to you We guarantee to be professional, reliable, helpful and very competitive; we offer a last minute service at no extra cost, and we also undertake weekend working both on Saturday and Sunday in order to meet your out of hours testing requirements. We offer a nationwide service offering a single supplier for all of your projects. Most of our clients, who use us for the first time, continue to use our services because of our proactive and helpful testing service. It is our continual aim to help you pass at the first attempt. This proactive approach has led to nationwide agreements with some of the top UK Contractors, which allows them to benefit from even more competitive rates. To help your company prepare for future Testing we have included the following appendices. APPENDIX 1 - Air Leakage Design checklist APPENDIX 2- APPENDIX 3- Air Leakage Test, Contractors checklist of items that need to be completed prior to a test. Acoustic Test, Checklist of items that need to be completed prior to a test. I hope that by way of this introduction letter and the attached information, you are now more informed about the testing requirements of Part L & Part E and the services we offer. If you need any further information or a quotation please feel free to contact Malcolm Fish on 07967233836. Please also feel free to visit our website for an online quote at www.airpressuretesting.net Yours Faithfully Malcolm Fish Technical Director Air Pressure Testing Ltd info@airpressuretesting.net

APT - 5 - Appendix 1: Design Checklist Successful building leakage air tests and air tight building construction stems from an attention to detail at both the design and construction stages of the project. An airtight barrier layer needs to be identified within the building, and this layer extended to all facets of the building elevations. The following information identifies the most common types of materials used to construct building envelopes, and highlights the areas where particular attention needs to be paid. Wall Constructions: The inner skin of the external walls should ideally form the airtight barrier in wall constructions. External walls should be extended from floor level to the underside of intermediate floors and roofs. All gaps between blockwork and intermediate floors, roof members, windows/doors, steel columns, etc should be sealed. Blockwork: Standard blockwork is not impermeable to air unless it is plastered. The block density and standard of mortar joints have a significant impact on the overall permeability of the construction. Full mortar joints are preferable. Painting blockwork reduces the permeability and two coats of emulsion can make a significant improvement. Drylining: Ensure that the external walls are completed and fully sealed prior to springing internal stud partitions from them. Avoid/minimise service outlets such as sockets, data outlets etc in the dry lining of external walls as they are rarely well sealed. Make sure that blockwork behind dry lining has full mortar bed joints and perps. The gaps at the top & bottom of the plasterboard should be sealed. Sheet Metal Cladding: Insulation to the correct density needs to be used and compressed to the correct thickness within the construction and mastic joints used to seal the sheets. Profiled closer pieces of the correct size and profile must be used and sealed where panels meet other constructions. Composite panel systems are generally better than in-situ built up systems, since the joints between panels have gaskets and the steel cladding layers are completely filled with foam. Special attention needs to be paid at the interface between wall cladding and other methods of construction. The head of the wall/ underside of roof junction is particularly susceptible to leaking. Curtain Walling Systems Curtain walling systems are normally well designed and constructed with gasket joints between panels and frame construction. Generally it is the joints with other types of construction such as Concrete edge beams, roof parapets, brickwork etc. In addition care needs to be taken with multi storey construction to avoid air leakage between floors.

APT - 6 - Floor constructions: Cast In situ Concrete Slab: This type of floor provides the best type of airtight seal since the concrete fills any voids, both horizontally and vertically. Pre-cast Hollow Concrete Floor Planks: The hollow core of this type of floor can allow air to track horizontally and end up outside the airtight layer of a cavity wall. The problems are made worse with drainage and service penetrations, which if poorly sealed allows air to enter the hollow core and escape. Care should be taken to ensure all penetrations are sealed properly. We would recommend that the ends of the concrete planks are also sealed. Beam and Block Floors: This type of floor construction can lead to similar problems to those described for the pre cast planks above. Ceiling Constructions: Where roof/ceiling voids exist, lay in type false/suspended ceilings do not form an airtight barrier layer. Plasterboard type ceilings if plastered and edges sealed are significantly better than other types of lay in ceilings. Roof Constructions: Profiled Metal Decking: The inside surface of the decking if possible should form the airtight barrier and needs to be sealed to all the adjoining structure and the sheets sealed to each other during the construction of the roof. Use of the vapour barrier as the airtight layer should be avoided since this is rarely an effective seal. Steelwork supporting the roof can sometimes prevent access to the roof decking above and prevent a satisfactory seal being formed. Careful detail is needed to address this. Any Profiled decking can cause difficulties in sealing walls where they run on the underside. A profiled closer piece should be used to fill the void, and this in turn should be sealed with mastic. Flat Roofs: These types of roof generally provide a good airtight barrier over the main horizontal area of the roof, since they are designed to prevent water ingress. Particular care needs to be taken around parapet walls, flashings and roof penetrations.

APT - 7 - Doors and Windows: Door and window frames need to be sealed to the internal air tight barrier and not just sealed to the external façade. Window sills are often an area, which performs particularly poorly and should be fitted after the cavity has been sealed using an appropriate cavity closer. Lift Shaft Doors: Lift shafts have a permanent vent to outside at the head of the shaft and should be fitted with effective doors seals at each landing. Any floor or ceiling voids adjacent to the shaft should also be adequately sealed to prevent leakage. Loading Bay Doors: Concertina type sliding doors are very difficult to seal. Where possible, Roller Shutter or Sectional type doors, with good quality rubber seals should be specified. The seal between the head of the door and the cladding soffit should be checked to make sure it fully closes the gap. Mechanical and Electrical Systems: The airtight barrier should generally step inside the building separate the plant rooms from the rest of the building. The plant room partition walls, floors and ceiling as well as service risers require careful sealing around all mechanical and electrical service penetrations. Particular care is needed to fill voids INSIDE electrical service trunking. All incoming service ducts should be sealed after the services have been installed. Sanitary Services: All drainage traps including floor gullies and air handling plant condensate traps should be filled with water prior to the test. Detailing and materials selection needs to be high on the list of priorities for all members of the team, right from the start of the project to ensure that: 1) The airtight barrier layer is identified 2) The correct products are used where required 3) The relevant areas are monitored throughout the construction phase The use of certain types of products such as adhesive tapes or expanding foam should be avoided since these do not perform over the life of the building.

APT - 8 - Appendix 2: Checklist of Items to be completed prior to our arrival on Site to undertake the Air Leakage Test 1. Prior to attending site we require accurately calculated values for the Floor Area, External Wall Area, Roof Area & Volume of the building. We will also require a set of floor plans and elevations to mark up areas of leakage in the event of a test failure. 2. We will require the Design Air Leakage Rate or Air Permeability for the building. For commercial buildings this is generally 10 m 3 /hour/m 2, but can be lower, if requested in SBEM calculations. For houses the value is generally lower than 10 m 3 /hour/m2 and should be documented in the SAP rating report. 3. We require TWO 240v mains power electric sockets within 5 metres of EACH of our testing equipment set up. 4. Ensure that the completed building envelope is finished. All doors, windows, and cladding must be installed, or if items, such as glazing are missing, they should be sealed up to prevent air leakage. 5. Seal with tape or cardboard any duct work and mechanical vents to the outside. Pay particular attention to the air conditioning system. 6. Seal all ducts and penetrations where the main services enter the building. 7. Seal all SVP and waste pipe penetrations passing through external walls and ceilings. Make sure that the tops, sides & ends of all pipe boxing s are sealed to prevent air leaking into the boxing and escaping through SVP/waste pipe penetrations. 8. Ensure that all toilets and U bends in sinks have water in them. 9. Turn off all pilot lights and combustion equipment. Seal all flues. 10. Decide which personnel door/s are to be used for the test. Make sure that there are no obstructions within 3 meters of the inside and outside of the door/s chosen for the test. In some cases the door/s may need to be removed, if so you will need to supply an attendance to remove the door/s. 11. Ensure all external doors and windows are closed fully and trickle vents closed. Internal doors should be wedged open. 12. Smoke vents are to be closed but NOT SEALED. 13. Lift shaft vents are to be left open, with lift doors closed. 14. Remove 1% of ceiling or floor tiles that are adjacent to the external envelope. 15. In houses all penetrations through the top floor ceilings should be sealed.

APT - 9-16. Have a competent member of your staff available on the test day to modify and/or seal any further areas that we identify as requiring extra work. 17. If the door/s chosen for the test has a larger opening larger than 1.200m x 2.100m high, you will need to modify the opening to suit our standard template. (Please call us for advice should this be required.) 18. Whilst we would prefer to have the building empty during the test duration, people can stay in the building whilst the test is in progress. They may not however enter or leave during the test period. (Approx 1-2 hours) 19. The customer must confirm the test date in writing at least 72hrs before the programmed test date, if this doesn t happen APT reserve the right to cancel the Air Leakage Test until written confirmation is received. 20. We require a parking space for a transit van type vehicle within 10 metres of the test location on site. 21. Testing cannot take place in high winds or if significant temperature differences persist, particularly for high buildings. You should inform us immediately if on the day of the test high winds in excess of 6 m/s are experienced, and a personnel door in a sheltered area cannot be utilised. If we arrive on site to carryout the test and have to abort the test due to wind speeds in excess of 6 m/s the full test fee will be payable. 22. If we arrive on site and are delayed due to the site not being prepared adequately, or the items in this checklist not being completed prior to our arrival, we reserve the right to cancel the test. The full test fee will be payable. If you have any questions about the preparation or actual test, then please ring our offices to discuss them. We are here to help you achieve a pass at the first attempt.

APT - 10 - Appendix 3: Checklist of Items to be completed prior to our arrival on Site to undertake the Acoustic Test The best time to carry out sound testing is towards the completion of the project. In addition the optimum conditions are when the site is quiet. If there is noise on the site from equipment and 'on going works' here is an increased chance of a sound test failure. Housing developers and/or site managers will have to nominate a day for testing and restrict any noisy activity during the tests. The following list provides an indicative checklist for site managers for the requirements of the plots and sites where testing may be carried out. A site is ready for testing when: 1. Windows are fully fitted with locks in place. 2. Window trickle vents are in place or temporarily blocked up for testing. 3. Room and front doors are in place and closable. 4. All wall surfaces in rooms to be tested are complete (including sockets and switches if applicable). 5. Floor and ceiling surface are complete. 6. All rooms need to be clean and cleared of all materials and operatives. 7. Carpets or timber laminates have NOT been laid in rooms where floors are to be tested (with the exception of bonded carpet). 8. Staff made aware that a quiet site environment is required during testing 9. We require 2 No. 240 Volt mains power sockets in each of the rooms to be tested.