Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous



Similar documents
Contact expansion modules

Contact expander modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PNOZsigma - Base units

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PNOZ s3. Safety relays. Operating Manual EN-10

PNOZ s5. Safety relays. Operating Manual EN-09

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety technique. Emergency stop module BO 5988 safemaster

RM4TG20 three-phase network control relay RM4-T - range V

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Safety Manual BT50(T) Safety relay / Expansion relay

Redundancy Module QUINT-DIODE/40

38 Series - Relay interface modules A

SMS 4 / SMS 5 safety mat Product information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic overload relay EF19 and EF45

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Safety automation solutions

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

49 Series - Relay interface modules A. Features

Electronic overload relay EF65, EF96 and EF146

38 Series - Relay interface modules A

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RY2 miniature industrial relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Units PSENmag. PSEN 2.2p Unit features. Function description

CONFIGURABLE SAFETY RELAYS

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Relés e Contatores de Estado Sólido SIRIUS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Quick Connect. quick - simple - efficient.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PHOENIX CONTACT Features

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Product and functional description

Pluggable interface relays CR-P Pcb relays

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Preset Counter signo 721

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay CM-PFE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Type: DILM9 10(24VDC) Article No.:

Safety Relays ESM/ESM-F

Type: DILM32 10(24V50HZ) Article No.:

Digital input modules

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Vario-Series Accessories

Easy Multifunctional Safe

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermal-Magnetic Circuit Breaker M1-..

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power Supplies 3. SDN-P DIN Rail Series

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MasterINTERFACE 39 Series - Relay interface modules

Preventa Machine Safety Products

Cross-beam scanning system to detect slim objects. 100 mm in

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Emergency lighting units EM powerled

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

HERZ-Thermal Actuators

40 Series - Miniature PCB/Plug-in relays A. Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

CONFIGURABLE SAFETY RELAYS

Thermistor motor protection

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Cable Plug acc. to DIN EN , Form A

3-phase, bidirectional energy meter

Power Thyristor TS3 (SP) 3ph. Installation Guide

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Bimetallic Overload Relay Specifications

Transcription:

Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous Safe separation of safety contacts 13-14, 23-24, 33-34 from all other circuits Supply voltage for s LED for: Supply voltage at B1 and B2 Input status, channel 1 Input status, channel 2 Switch status of the safety contacts Error Plug-in connection terminals (either spring-loaded terminals or screw terminals) Unit description Bestimmung/Gerätebeschreibung Kontakterweiterungen Schalt_PNOZ The unit meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. The contact is used to increase the number of instantaneous safety contacts available on a base unit. Base units are all safety relays with feedback loop monitoring. The category that can be achieved in accordance with EN 954-1 and EN ISO 13849-1 depends on the category of the base unit. The contact may not exceed this. Safety features Sicherheitseigenschaften Kontakterweiterungen allg_pnoz The unit meets the following safety requirements: The contact expands an existing circuit. As the output relays are monitored via the base unit's feedback loop, the safety functions on the existing circuit are transferred to the contact. The safety function remains effective in the case of a component failure. Earth fault in the feedback loop: Detected, depending on the base unit that is used. Earth fault in the input circuit: The output relays de-energise and the safety contacts open. Zulassungen Block diagram Blockschaltbild A1 A2 13 23 33 * B1 B2 = = Input K1 = = Interface base unit Power K2 Interface Y1 Y2 14 24 34 * Safe separation in accordance with EN 60947-1, 6 kv

Function description ][Funktionsbeschreibung_Erweiterungsgerte_Kaskadenmodul with base unit: Dual-channel operation via connector without base unit: Single-channel operation: one input circuit affects the output relays with s7.2 expander units: Dual-channel operation and supply voltage via connector Timing diagram ][Zeitdiagram_PNOZs_Kontakterw_in_out_aux-rfk POWER Input Output safe Feedback t1 t2 t1 t2 Key Power: Supply voltage Input: Input circuits Wiring Output safe: Safety contacts 13-14, 23-24, 33-34 Feedback: Feedback loop 51-52 t 1 : Switch-on delay t 2 : Delay-on de-energisation ][Verdrahtung_Si_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34 are safety contacts. To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. -2

Preparing for operation Betriebsbereitschaft herstellen PNOZs Supply voltage Supply voltage AC DC Base unit: Safety relay PNOZs Interface PNOZs Base unit: Safety relay PNOZ X 24 V DC A1 A2 0 V Supply voltage for s 24 V DC B1 B2 0 V Input circuit Input circuit Single-channel Dual-channel Base unit: Safety relay base unit Interface Base unit: Safety relay PNOZ X 24 V DC A1 A2 0 V Base unit: Safety relay PNOZelog Driven via semiconductor outputs (24 VDC) 0 V O1 A1 A2 L-

Reset circuit/feedback loop Reset circuit/feedback loop Base unit: Safety relay PNOZ X Base unit: Safety relay PNOZelog The inputs that evaluate the feedback loop will depend on the base unit and application feedback loop Y1 Y2 feedback loop Y1 Y2 24 V DC Connection to base unit Base unit: Safety relay The feedback loop is connected and evaluated via the connector. base unit Interface ][Betriebsbereitschaft_herstellen_Info_Erweiterungsgert_Kaskadenmodul_DB INFORMATION If a base unit and a contact from the range are linked via the connector, no additional wiring is necessary. Do not connect A1 und Y1/Y2 to the! -4

Terminal configuration Klemenbelegung Power Installation Montage _7_1 Install contact without base unit: Ensure that the plug terminator is inserted at the side of the unit. Connect base unit and contact : Remove the plug terminator at the side of the base unit and at the left of the contact Connect the base unit and the contact using the connector supplied, before mounting the units to the DIN rail. Connect contact to contact s Connect the contact s using the connector supplied. Control cabinet installation The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail (35 mm). When installed vertically: Secure the unit by using a fixing element (e.g. retaining brakket or end angle). Push the unit upwards or downwards before lifting it from the DIN rail. ][Montage Erweiterungsgert_Kaskade_DB Expansion options Please note the max. power consumption of the contact s (see Technical data ). : Base unit base unit s7.1 with terminator... 1 2 4 3

: Base unit base unit s7.1 s7/s8/s9/s10/s11 PNOZ s7, s8, s9, s10, s11 as terminator... 1 2 4 3 with terminator with terminator s7.1... 1 2 3 with terminator PNOZ s7, s8, s9, s10, s11 as terminator s7.1 s7/s8/s9/s10/s11... 1 2 3 : Base unit base unit s7.1 s7.1... 1 2 3 4 5 6 with terminator -6

Dimensions Abmessungen *with spring-loaded terminals 120 (4.72") 98 (3.86") * 100 (3,94") 17,5 (0.69")

NOTICE ][Wichtig_PDB This data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation. Service life graph Lebensdauerkurve_Relais_Text vor Kurve The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Lebensdauerkurve Lebensdauerkurve_Relais_Text nach Kurve_SIF Bsp Example Inductive load: 0,2 A Utilisation category: AC15 Contact service life: 2,000,000 cycles Provided the application requires fewer than 2,000,000 cycles, the PFH value (see technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With contactors, use freewheel diodes for spark suppression. Technical details Technical details Electrical data Supply voltage Supply voltage U B DC 24 V Voltage tolerance -20 %/+20 % Power consumption at U B DC 2.0 W Max. output of all s 20 W Residual ripple DC 20 % Voltage and current at Input circuit DC: 24.0 V 70.0 ma Number of output contacts Safety contacts (S) instantaneous: 3-8

Electrical data Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A P max : 1500 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A P max : 150 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 5.0 A Contact material AgCuNi + 0.2 µm Au External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 30 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1: 2006 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 T M [year] in accordance with EN ISO 13849-1: 2006 20 Times Switch-on delay with automatic reset after power on typ. 30 ms with automatic reset after power on max. 50 ms Delay-on de-energisation with E-STOP typ. 18 ms with E-STOP max. 30 ms with power failure typ. 18 ms with power failure max. 30 ms Supply interruption before de-energisation 5 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4 Vibration to EN 60068-2-6 Frequency 10.0-55.0 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 6.00 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20

Mechanical data Housing material Housing PC Front PC Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG No. 750167 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG No. 750167 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG No. 750167 Torque setting with screw terminals 0.50 Nm No. 750167 Cross section of external conductors with spring-loaded terminals: 0.20-2.50 mm², 24-12 AWG No. 751167 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 No. 751167 Stripping length 9 mm No. 751167 Dimensions Height 100.0 mm No. 751167 98.0 mm No. 750167 Width 17.5 mm Depth 120.0 mm Weight 170 g Technische Daten_Satz No. No. stands for order number. Si-Kennzahlen_Zusatz_Relais_Lebensdauer_PDB It is essential to consider the relay's service life graphs. The relay outputs' safety-related characteristic data is only valid if the values in the service life graphs are met. The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. Si_Kennzahlen_Erläuterung_1 All the units used within a safety function must be considered when calculating the safety characteristic data. Si_Kennzahlen_Erläuterung_2 INFORMATION A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Technische Daten_Satz Normen The standards current on 2007-10 apply. ][Dauerstrom_DC Conventional thermal current while loading several contacts Number of contacts I th per contact at U B DC 1 6.00 A 2 5.50 A 3 4.50 A Bestelldaten Order reference Type Features Terminals Order no. C 24 VDC With spring-loaded terminals 751 167 24 VDC With screw terminals 750 167-10