Measurement System for Solar Cell Manufacturing

Similar documents
Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

Coating Technology: Evaporation Vs Sputtering

It has long been a goal to achieve higher spatial resolution in optical imaging and

Spectroscopic Ellipsometry:

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Coating Thickness and Composition Analysis by Micro-EDXRF

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

2 Absorbing Solar Energy

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Solar Photovoltaic (PV) Cells

Preface Light Microscopy X-ray Diffraction Methods

Pulsed laser deposition of organic materials

XFA 600 Thermal Diffusivity Thermal Conductivity

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

Physics 441/2: Transmission Electron Microscope

ALD Atomic Layer Deposition

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

2. Deposition process

h e l p s y o u C O N T R O L

Spectral Measurement Solutions for Industry and Research

Neuere Entwicklungen zur Herstellung optischer Schichten durch reaktive. Wolfgang Hentsch, Dr. Reinhard Fendler. FHR Anlagenbau GmbH

Project 2B Building a Solar Cell (2): Solar Cell Performance

NANO SILICON DOTS EMBEDDED SIO 2 /SIO 2 MULTILAYERS FOR PV HIGH EFFICIENCY APPLICATION

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

How To Make A Plasma Control System

Electron Beam and Sputter Deposition Choosing Process Parameters

How To Understand Light And Color

The photoionization detector (PID) utilizes ultraviolet

OPTIMIZING OF THERMAL EVAPORATION PROCESS COMPARED TO MAGNETRON SPUTTERING FOR FABRICATION OF TITANIA QUANTUM DOTS

DIEGO TONINI MORPHOLOGY OF NIOBIUM FILMS SPUTTERED AT DIFFERENT TARGET SUBSTRATE ANGLE

Applications of Infrared Multiple Angle Incidence Resolution Spectrometry

Development of certified reference material of thin film for thermal diffusivity

Introduction to VLSI Fabrication Technologies. Emanuele Baravelli

Introduction to Fourier Transform Infrared Spectrometry

Optical Properties of Sputtered Tantalum Nitride Films Determined by Spectroscopic Ellipsometry

Raman spectroscopy Lecture

Robert G. Hunsperger. Integrated Optics. Theory and Technology. Fourth Edition. With 195 Figures and 17 Tables. Springer

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

Chapter 4 Indium Tin Oxide Films Deposited by d.c. Sputtering

Back to Basics Fundamentals of Polymer Analysis

Spectral Characterisation of Photovoltaic Devices Technical Note

The study of structural and optical properties of TiO 2 :Tb thin films

Advanced Solutions for Gas Monitoring

Electromagnetic Radiation (EMR) and Remote Sensing

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

MCAL Spectrophotometry. Spectrophotometry

Optical Monitoring of Thin-films Using Spectroscopic Ellipsometry

Improved Contact Formation for Large Area Solar Cells Using the Alternative Seed Layer (ASL) Process

Prussian blue nanoparticles for laser-induced photothermal therapy of tumors

High performance. Architectural glazings utilise thin. low-emissivity coating. Coating technology

GREEN NANOTECHNOLOGY. Geoffrey. Energy in the Built Environment. Solutions for Sustainability and. B. Smith Claes G. Granqvist.

Chapter 6 Metal Films and Filters

Agilent Cary 60 UV-Vis

Reactive Sputtering Using a Dual-Anode Magnetron System

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Light management for photovoltaics. Ando Kuypers, TNO Program manager Solar

Absorption by atmospheric gases in the IR, visible and UV spectral regions.

Short overview of TEUFEL-project

For Touch Panel and LCD Sputtering/PECVD/ Wet Processing

Copyright by Mark Brandt, Ph.D. 12

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

High Rate Oxide Deposition onto Web by Reactive Sputtering from Rotatable Magnetrons

Time out states and transitions

3 - Atomic Absorption Spectroscopy

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Thermal diffusivity and conductivity - an introduction to theory and practice

SOLAR ELECTRICITY: PROBLEM, CONSTRAINTS AND SOLUTIONS

Arizona Institute for Renewable Energy & the Solar Power Laboratories

Vacuum Evaporation Recap

Al 2 O 3, Its Different Molecular Structures, Atomic Layer Deposition, and Dielectrics

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Dry Etching and Reactive Ion Etching (RIE)

Keywords: Planar waveguides, sol-gel technology, transmission electron microscopy

Characterization of sputtered NiO thin films

INFRARED PARTS MANUAL

Application Note AN1

Light management for photovoltaics using surface nanostructures

Introduction to OLED technology 1. General characteristics

Results Overview Wafer Edge Film Removal using Laser

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Types of Epitaxy. Homoepitaxy. Heteroepitaxy

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Sputtered AlN Thin Films on Si and Electrodes for MEMS Resonators: Relationship Between Surface Quality Microstructure and Film Properties

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

High power picosecond lasers enable higher efficiency solar cells.

Blackbody Radiation References INTRODUCTION

Nanoscience Course Descriptions

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Experiment #5: Qualitative Absorption Spectroscopy

Fabrication and Characterization of Nanostructured Silicon Films For Photovoltaic Applications. Kai Wang

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Nanoscale Resolution Options for Optical Localization Techniques. C. Boit TU Berlin Chair of Semiconductor Devices

FRAUNHOFER INSTITUTe For

Acousto-optic modulator

Transcription:

Measurement System for Solar Cell Manufacturing Manufacturer: Semilab Model: WT-2000PVN Place: Egypt Nanotechnology Center, Contact: Dr. Osama Tobail Cairo University, Shaikh Zayed Campus, Osama.tobail@egnc.gov.eg B3 The WT-2000PVN system is a platform that equipped with a variety of measuring options. This allows characterization of silicon samples in diverse ways. It is a useful tool for incoming wafer inspection, quality control and process monitoring in wafer manufacturing as well as in solar cell manufacturing. 1. μ-pcd for determination of minority carrier lifetime 2. LBIC for diffusion length and internal quantum efficiency evaluation on solar cells 3. Eddy current for measurement of resistivity 4. SHR for determination of sheet resistance The system is suitable for measuring R&D samples as well as industrial silicon wafers and solar cells up to 8 inch. This measurement can help in production line and process assessment in the field of silicon solar cell manufacturing and in characterizing solar cells developed in laboratories to evaluate either the material or the process quality. 1

Photo-conductance Lifetime Tester and Suns-Voc Manufacturer: Sinton Instruments Model: WCT-120 with Suns-Voc Place: Egypt Nanotechnology Center, Cairo University, Shaikh Zayed Campus, B3 Contact: Dr. Osama Tobail Osama.tobail@egnc.gov.eg The WCT-120 Lifetime Test Instrument employs Sinton Instruments unique and powerful measurement and analysis techniques. The instrument uses an eddy-current conductance sensor and a filtered xenon flash lamp to measure carrier lifetime. Measurements can be taken using either Quasi-Steady-State-Photoconductance (QSSPC) method or Transient PhotoConductance Decay (Transient PCD). This instrument is ideal for evaluation and optimization of material quality, dopant diffusion, and passivation quality in silicon photovoltaic wafers and cells. The Suns-Voc instrument is ideal for optimizing metallization and firing parameters in solar cells and solar cell precursors. 1. Measurement Results Lifetime Sheet Resistance (average resistivity) Emitter saturation current density Trap Density One-Sun Implied Open Circuit Voltage Implied I-V curve at open circuit Pseudo-efficiency and pseudo-fill-factor 2. Lifetime Measurement Range from 100ns to greater than 10ms 3. QSSPC, Transient, and Generalized measurement and analysis modes 4. Resistivity measurement from 3 to 600 (undoped) ohms/square 5. Temperature controlled chuck (25 C) for the Suns-Voc measurement 2

Spectroscopic Variable Angle Ellipsometer Manufacturer: Semilab Model: GES5-E Place: Egypt Nanotechnology Center, Cairo University, Contact: Dr. Osama Tobail Shaikh Zayed Campus, B3 Osama.tobail@egnc.gov.eg GES5-E spectroscopic ellipsometer enables the determination of the thickness as well as the optical parameters (absorption and refraction) for one thin layer or a stack of nano-layers by means of analyzing the change in the polarization status of light. Layers with thickness down to 3 to 4 nm were analyzed by this equipment at Egypt Nanotechnology Center. The system is equipped with a powerful software for analyzing the data. In general, the course of ellipsometric data evaluation involves three main steps. Firstly, a structure model has to be assumed for the investigated sample as well as assignment of phase types (n&k file, dispersion laws, EMA, diffusion, alloy, periodic, anisotropy) for each defined layer is also necessary. In the second step the initial parameterization of selected optical functions should be made by interactive simulations. The third step invokes a curve fitting procedure to determine the fitted parameters. 1. Powerful software for data analysis and automatic mapping for samples up to 8 inch wafers 2. Vacuum chuck to fix the substrate during measurement 3. Determination of the absorption coefficient and refractive index of new material by assuming dispersion laws 4. Analysing nano layers of nanocomposites by the Effective Medium Theory 3

Solar Cell Quantum Efficiency Measurement System Manufacturer: Protoflex Model: QE1100 Place: Egypt Nanotechnology Center, Cairo University, Contact: Dr. Osama Tobail Shaikh Zayed Campus, B3 Osama.tobail@egnc.gov.eg Quantum efficiency (QE) is used to determine the sensitivity of a photosensitive device, such as a solar cell. It is defined as the percentage of photons hitting the photoreactive surface which will product an electron-hole pair. When measured over a range of different wavelengths, it enables the characterization of a device s efficiency at each energy level. When summed across the entire solar electromagnetic spectrum, it can be used to calculate the current that a solar cell will generate when exposed to white light. 1. The ProtoFlex Quantum Efficiency Measurement System, Model QE-1100, provides capability for the accurate measurement of quantum efficiency of photosensitive devices and the transmission properties of thin films. 2. The system provides absolute accuracy of ±2% over a wavelength range of 300-1100 nm over an area of 10 cm x 10 cm (4 x 4 ). 3. The analysis of the measured QE data gives information about the cell performance in terms of collection length, reflection and internal quantum efficiency which enables cell development. 4. Silicon certified reference cell is available for calibration. 5. Light and voltage biasing is available 4

Six-Source Thermal Co-Evaporator Manufacturer: Protoflex Model: Evap007 Place: Egypt Nanotechnology Under Installation Center, Cairo University, Shaikh Zayed Campus, B3 Physical Vapor Deposition (PVD) technique based on evaporating the material from a solid source in vacuum and depositing it on a substrate with a controlled thickness. 1. Evaporation from up to three sources simultaneously 2. Sequential deposition of several layers up to 6 different material for any number of layers 3. Recipe based and manual deposition with thickness monitoring 4. Substrate heating from RT to 800C 5. Substrate size up to 8 wafer 6. Evaporating in a controlled oxygen flow for oxide deposition from metal sources 5

Six-Target Magnetron Co-Sputtering Manufacturer: Protoflex Model: Sputt007 Place: Egypt Nanotechnology Under Installation Center, Cairo University, Shaikh Zayed Campus, B3 Physical Vapor Deposition (PVD) technique based on sputtering the material from a solid target in vacuum by plasma and depositing it on a substrate with a controlled thickness. The system uses Argon for sputtering and other gases for reactive sputtering. 1. Three DC and three RF magnetrons 2. Deposition from up to three sources simultaneously 3. Sequential deposition of several layers up to 6 different material for any number of layers 4. Recipe based and manual deposition 5. Substrate heating from RT to 800C 6. Substrate size up to 8 wafer 7. Reactive sputtering with O2 or N2 or both 6

Atomic Force Microscope: Manufacturer: Agilent Technologies Model: 5600LS Place: Egypt Nanotechnology Center, Cairo Contact: Dr. Mostafa Elashry University, Shaikh Zayed Campus, B3 Mostafa.elashry@egnc.gov.eg Atomic Force Microscopy (AFM) can resolve features as small as an atomic lattice, for either conductive or non-conductive samples. AFM provides high-resolution and three-dimensional information, with little sample preparation. The technique makes it possible to image in-situ, in fluid, under controlled temperature and in other controlled environments. The options of AFM extend to applications in life science, materials science, electrochemistry, polymer science, biophysics, nanotechnology, and biotechnology. The equipment can be operated in the following modes: Contact Mode imaging AC mod (tapping) Scanning tunneling microscope Current sensing 7

Fourier Transform Infra-red spectroscopy: (FTIR) Manufacturer: Thermo Model: Nicolet 6700 Place: Egypt Nanotechnology Center, Cairo Contact: Dr. Mostafa Elashry University, Shaikh Zayed Campus, B3 Mostafa.elashry@egnc.gov.eg Fourier transform infrared spectrometer (FT-IR) for the analysis of organic and inorganic compounds. a. Spectral Range: 375 to mid IR Optical resolution: 0.2 cm-1 or less Detectors : i. Deuterated Triglycine Sulfate (DTGS) Detectors (Temperature-stabilized) ii. Mercury cadmium telluride (MCT) [liquid Nitrogen cooled] Sources: i. Near -Mid-IR source to cover the IR range ii.white light source to cover the visible range Beam splitter: KBr beam splitter Precision: 0.01 cm-1 or better Purgeable chamber Auto validation facility as per NIST traceable validation kit, certified/astm protocol Samples capability: i. gaseous, liquid and solid, ii. transmission and surface analysis 8

X-ray Diffraction (XRD) Manufacturer: Bruker Model: D8 Discover Place: Egypt Nanotechnology Contact: Dr. Ahmed Abou-Kandil Center, Cairo University, Shaikh Ahmed.akandil@egnc.gov.eg Zayed Campus, B3 Wide Angle X-ray Diffraction with Small Angle Capability 1. The D8 DISCOVER with DAVINCI design increases ease-of-use with real-time component detection, plug-and-play functionality and fully integrated 2-dimensional XRD capabilities. 2. X-ray diffraction applications, including reflectometry, high-resolution diffraction, inplane grazing incidence diffraction (IP-GID), small angle X-ray scattering (SAXS), as well as residual stress and texture investigations. 3. For a 2-D detector, size is the most important feature. A large detector window not only enables increased data collection speed, it also provides information that is simply not accessible with 0-D, 1-D or smaller 2-D detectors. The VÅNTEC-500 detector features a huge 140 mm diameter window, covering up to about 80 (2θ) and a large γ-range. 4. The factory-aligned, SNAP-LOCK X-ray optics provide true plug-and-play functionality, including automatic and tool-free switching of the diffraction geometry with minimal user intervention. 5. An X-ray optics module, a detector, or any accessory mounted onto the instrument registers itself in real-time with its relevant parameters and analytical capabilities, including powerful detection of possible component conflicts. 9