Back-UPS Pro 900 Installation and Operation



Similar documents
Back-UPS Pro 1300/1500 Installation and Operation

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Powerware 5110 UPS User s manual

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC VA Rack-mount 2U 120/208/230 VAC

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Installation and Operation

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

Operation Manual. Smart-UPS X Uninterruptible Power Supply

APC Smart-UPS 2400/3000 VA 100/ VAC 3U. Uninterruptible Power Supply

750VA/1000VA/1500VA 100/120/230VAC 2U

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

User Manual 1K/2K/3K Online UPS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Installation and Operation

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

USER MANUAL Online UPS 1K/2K/3K Rack

USER MANUAL Online UPS 1K/2K/3K

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

How To Use A Power Supply Unit (Upu)

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Online UPS. PowerWalker VFI 1000R/1U

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Symmetra LX. Operations Guide

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

APC Smart-UPS 2200/3000 VA 100/120/230 VAC. Uninterruptible Power Supply C 12/20005

Uninterruptible Power Supply

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Notice. Reverse engineering and disassembly are prohibited.

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

How To Install A Power Supply (Uplast) With A Battery Pack

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200/3000 VA Tower 120/230 VAC

Internet Office UPS System Standby UPS for PCs, workstations and more

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

EKOS Cart. Instructions for Use

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Residential Gateway (RG) Battery Backup

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

User s Manual AURORA 1.2K/2.2K

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Lenovo IdeaPad. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Lenovo IdeaPad U510. User Guide V1.0. Read the safety notices and important tips in the included manuals before using your computer.

BroadBand PowerShield. User Manual

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Ambient Temperature In Range Probe X

Line Interactive UPS

Using GIGABYTE Notebook for the First Time

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Internet Office 500VA Tower Standby 120V UPS with USB port

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Lenovo IdeaPad Z500/P500

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Residential Gateway (RG) Battery Backup REV B

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

BC Pro UPS System Standby UPS System

UPS-2200R-HH/UPS-2200R-HHIP

Single Day Alarm Clock with. Bluetooth and USB Play-through

HP Advanced Wireless Docking Station. User Guide

UPS VA User s Manual

User Guide. Linksys PLWK400. Powerline AV Wireless Network Extender Kit

User Guide. Temperature and Humidity Datalogger. Model 42280

SPL 2-00/-01 OPERATION INSTRUCTIONS

Transcription:

Back-UPS Pro 900 Installation and Operation Inventory Safety bu001a (2) Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a bu060a bu055a bu057a Install PowerChute Personal Edition Software APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the event of a power failure. Use the cable supplied with the Back-UPS to connect the data port on the Back-UPS to the USB port on your computer. Place the CD into your computer, and follow the on-screen instructions.

Connect the equipment Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the Back-UPS. Connect equipment such as printers, fax machines, scanners, or other peripherals that do not need battery backup power to the Surge Protection Only outlets. These outlets provide full-time protection from surges even if the Back-UPS is switched OFF. Master and Controlled outlets To conserve electricity, when the device connected to Master Outlet goes into Sleep or Standby mode, or turns Off, the Controlled device(s) will shut down as well, saving electricity. Connect a master device, such as a desktop computer or audio/visual receiver to the Master outlet. Connect peripheral devices such as a printer, speakers, or a scanner to the Controlled outlets. bu130a USB and Serial Data port Telephone cable surge-protected ports Surge Protected outlets, controlled by the Master outlet Surge Protected outlets AC power outlet Battery Backup outlets with Surge Protection Battery Backup outlet with Surge Protection, controlled by the Master outlet Master outlet In & Out Ethernet surgeprotected ports Circuit breaker To use PowerChute Personal Edition, connect the supplied USB software cable or optional serial cable (not included). Connect a telephone cable to the IN port, and connect a modem to the OUT port. These outlets are protected from electrical surges, and will disconnect from utility power during a power outage, or if the Master device goes into Sleep or Standby mode. These outlets provide full-time surge protection, even when the unit is turned off. Connect equipment such as printers and scanners that do not require battery backup protection. Connect the unit to utility power, use the supplied power cord. During a power outage or other utility problems, these outlets provide power from battery. Connect critical equipment such as desktop computer, computer monitor, modem or other data sensitive devices into these outlets. These outlets will supply battery power to the connected equipment during a power outage. Power will be disconnected to these outlets if the Master device goes into Sleep or Standby mode. Connect equipment such as a computer monitor to these outlets. Connect the master device to this outlet, in most scenarios, this will be the main computer. Use an Ethernet cable to connect a cable modem to the IN port, and connect a computer to the OUT port. Use to reset the system after an overload or short circuit. 2 Back-UPS Pro 900 Installation and Operation

Operation Power-Saving Function To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving electricity. Enable the Power-Saving function. Press and hold MUTE and DISPLAY simultaneously for two seconds. The Back-UPS will beep to indicate that the feature is enabled. The leaf icon on the display will illuminate. Disable the Power-Saving function. Press and hold MUTE and DISPLAY simultaneously for two seconds. The Back-UPS will beep to indicate that the feature is disabled. The leaf icon on the display will darken. Setting the threshold. The amount of power used by a device in Sleep or Standby mode varies between devices. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down. 1. Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it OFF. 2. Press DISPLAY and MUTE simultaneously and hold for six seconds, until the leaf icon flashes three times and the Back-UPS beeps three times. 3. The Back-UPS will now recognize the threshold level of the Master device and save it as the new threshold setting. Power-Saving Display The display interface can be configured to be continuously illuminated, or to save energy, it can be configured to darken after a period of inactivity. 1. Full Time Mode: Press and hold DISPLAY for two seconds. The display will illuminate and the Back-UPS will beep to confirm the Full-Time mode. 2. Power-Saving Mode: Press and hold DISPLAY for two seconds. The display will darken and the Back-UPS will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the display will illuminate if a button is pressed, it then darkens after 60 seconds of no activity. Unit sensitivity Adjust the sensitivity of the Back-UPS to control when it will switch to battery power; the higher the sensitivity, the more often the Back-UPS will switch to battery power. 1. Ensure the Back-UPS is connected to utility power, but is OFF. 2. Press and hold the POWER button for six seconds. The LOAD CAPACITY bar will flash on and off, indicating that the Back-UPS is in programming mode. 3. Press POWER again to rotate through the menu options. Stop at selected sensitivity. The Back-UPS will beep to confirm the selection. Low sensitivity Medium sensitivity (Default) High sensitivity 156-300 Vac 176-294 Vac 176-288 Vac Input voltage is extremely low or high. (Not recommended for computer loads.) The Back-UPS frequently switches to battery power. The connected equipment is sensitive to voltage fluctuations. Back-UPS Pro 900 Installation and Operation 3

Front Panel Buttons and Display Interface Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS. Front panel Mute button Power On/Off button Display button Display interface bu044a bu002a On Line The Back-UPS is supplying conditioned utility power to connected equipment Power-Saving Master and Controlled outlets are enabled, saving power when the master device goes into sleep or standby mode Load Capacity The load is indicated by the number of sections illuminated, one to five. Each bar represents 20% of the load. Battery Charge The battery charge level is indicated by the number of sections illuminated. When all five blocks are illuminated, the Back-UPS is at full charge. When one block is filled, the Back-UPS is near the end of its battery capacity, the indicator will flash and the Back-UPS will beep continuously. Overload The power demand from the load has exceeded the capacity of the Back-UPS. Event The event counter shows the number of events that occurred that caused the Back-UPS to switch to on-battery operation. Automatic Voltage Regulation The Back-UPS can compensate for high or low input voltage. When illuminated, the Back-UPS is compensating for low input voltage. Input voltage. Output voltage. When illuminated, the Back-UPS is compensating for high input voltage. System Faults The system has a fault. The fault number will illuminate on the display interface. See System Faults on page 5. Mute If the line through the speaker icon is illuminated, the audible alarm has been turned off. Replace Battery The battery is not connected or is nearing the end of its useful life. Replace the battery. On Battery The Back-UPS is supplying battery backup power to the connected equipment, it will beep four times every 30 seconds. 4 Back-UPS Pro 900 Installation and Operation

Warnings and System Faults Audible Warnings Four Beeps Every 30 Seconds Continuous Beeping Continuous tone Chirps for 1 Minute every 5 hours Back-UPS is running on battery. You should consider saving any work in progress. Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system. Battery Backup outputs are overloaded. Battery fails the automatic diagnostic test and should be replaced. Warning Icons If these icons are illuminated... This may be the problem. The Back-UPS is operating on utility power, but is overloaded. Disconnect one of the items connected to the Back-UPS. If the Overload icon stops flashing, the Back-UPS is no longer overloaded and will continue to operate normally. The Back-UPS is operating on battery power, but is overloaded. Disconnect one of the items connected to the Back-UPS. If the Overload icon stops flashing, the Back-UPS is no longer overloaded and will continue to operate normally. The Back-UPS is operating on utility power, but the battery is not functioning properly. Contact APC Customer Service to order a replacement battery. See Replacement Battery on page 8. The Back-UPS is operating on battery power and the battery power is getting low. Shut down all connected equipment to avoid losing an unsaved data. When possible, connect the Back-UPS to utility power to recharge the batter. System Faults The Back-UPS will display these fault messages. For faults F01 and F02, contact APC Technical Support. bu088a F01 On-Battery Overload Turn the Back-UPS off. Disconnect non-essential equipment from the Battery Backup outlets and the turn Back-UPS on. F02 On-Battery Output Short Turn the Back-UPS off. Disconnect non-essential equipment from the Battery Backup outlets and the turn Back-UPS on. F03 On-Battery Xcap Overload F04 Clamp Short F05 F06 F07 F08 F09 Charge Fault Relay Welding Temperature Fan Fault Internal Fault Faults F03-F09 cannot be corrected by the user, contact APC Technical Support for assistance. Back-UPS Pro 900 Installation and Operation 5

Function Button Quick-Reference Function Button Timing (seconds) UPS Status Description Power Power On 0.2 Off Press POWER to start receiving input utility power. If A/C input power is not available, the Back-UPS will run on battery power. Power Off 2 On The Back-UPS is not receiving input utility power, but is providing surge protection. Display Status Inquiry 0.2 On Verify the status or condition of the Back-UPS. The LCD will illuminate for 60 seconds. Full-Time/Power- Saving mode 2 On The LCD will illuminate and the Back-UPS will beep to confirm the Full-Time mode. The LCD will darken and the Back-UPS will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the LCD will illuminate if a button is pressed, then darkens after 60 seconds of no activity. Mute Event Specific 0.2 On Disable any audible alarms caused by an event. General Status Enable/ Disable 2 On Enable or disable the audible alarms. The Mute icon will illuminate and the Back-UPS will beep one time. The Mute function will not activate unless the Back-UPS is operating on battery power. Sensitivity 6 Off The Load Capacity icon will blink, indicating that the Back-UPS is in programming mode. Use the POWER button to scroll through Low, Medium, and High, stop at selected sensitivity. The Back- UPS will beep to confirm selection. See Configuration for details. Master/Controlled outlet Enable/Disable Master/Enable Threshold Calibration 2 On The leaf icon will darken indicating that the Master Outlet feature is disabled or illuminate to indicate the Master Outlet feature is enabled. The Back-UPS will beep once. 6 On While calibrating the threshold setting, the device connected to the Master Outlet should be turned off or placed in Standby or Sleep mode. Upon completion, Power-Saving icon will flash 3 and beep 3 times. Self-Test (manual) 6 On The Back-UPS will perform a test of the internal battery. Note: This will happen automatically when the Back-UPS is turned ON. Event Reset 0.2 On When the Event screen is visible, press and hold DISPLAY, then press POWER, to clear the utility failure event counter. Fault Reset 2 Fault After a fault has been identified, press POWER to remove the visual indication and return to standby status. 6 Back-UPS Pro 900 Installation and Operation

Troubleshooting Problem Possible Cause Corrective Action Back-UPS will not switch on. The Back-UPS does not provide power during a utility power outage. The Back-UPS is operating on battery power, while connected to utility power. The Back-UPS is not connected to utility power. The circuit breaker has been tripped. The internal battery is not connected. The utility input voltage is out of range. Ensure that essential equipment is not plugged into a SURGE ONLY outlet. The plug has partially pulled out of the wall outlet, the wall outlet is no longer receiving utility power, or the circuit breaker has been tripped. The Back-UPS is performing an automatic self test. The utility input voltage is out of range, the frequency is out of range, or the waveform is distorted. The Back-UPS does not Battery Backup outlets may be fully or provide the expected amount of improperly loaded. backup time. The battery was recently discharged due to a power outage and has not fully recharged. The battery has reached the end of its useful life. The REPLACE BATTERY indicator is illuminated. The OVERLOAD indicator is illuminated. The SYSTEM FAULT indicator is illuminated, all the front panel indicators are flashing. Power is not supplied to some outlets. The battery has reached the end of its useful life. The equipment connected to the Back-UPS is drawing more power than the Back-UPS can provide. There is an internal fault. Power to the Controlled outlets has intentionally been turned off. The Controlled outlets are not The Master Outlet threshold may be supplying power, even though incorrectly set. the Master device is not in sleep mode. Ensure that the Back-UPS is securely connected to an AC outlet. Disconnect non-essential equipment from the Back-UPS. Reset the circuit breaker. Re-connect equipment one item at a time. If the circuit breaker is tripped again, disconnect the device that caused the trip. Connect the battery. Adjust the transfer voltage and sensitivity range. Disconnect equipment from the SURGE ONLY outlet and re-connect to a Battery Backup outlet. Ensure that the plug is fully inserted into the wall outlet. Ensure that the wall outlet is receiving utility power by checking it with another device. No action is necessary. Adjust the transfer voltage and sensitivity range. Disconnect non-essential equipment from the Battery Backup outlets and connect the equipment to SURGE ONLY outlets. Charge the battery cartridge for 16 hours. Replace the battery. Replace the battery. Disconnect non-essential equipment from the Battery Backup outlets and connect the equipment to SURGE ONLY outlets. Determine which internal fault message is displayed by matching the number displayed on the LCD with the corresponding Fault Message (see System Faults) and contact APC Technical Support. Confirm that the correct peripherals are connected to Controlled outlets. If this feature is not desired, disable the Power-Saving Master and Controlled outlets. Adjust the threshold when the Master outlet signals the Controlled outlets to shut down. Back-UPS Pro 900 Installation and Operation 7

Specifications t Model BR900GI VA 900 VA Maximum Load 540 W Nominal Input Voltage 230 V Online Input Voltage Range 176-294 V Automatic Voltage Regulation (188-216) +11.2% (252-282) -11.2% Frequency Range 50/60 Hz ± 1 Hz On-battery Waveshape Step-approximated sine-wave Typical Recharge Time 8 hours Transfer Time 10 ms, maximum Operating Temperature 0 to 40 C (32 to 104 F) Storage Temperature -15 to 45 C (5 to 113 F) Unit Dimensions 25 10 38.2 cm (9.84 3.93 15.0 in) Unit Weight 10.7 kg (23.6 lbs) Interface Serial, USB On-Battery Runtime Go to: www.apc.com EMI Classification CE, C-Tick, KETI Approvals CE, TUV-GS, GOST, A-Tick, KETI, TISI Replacement Battery The battery cartridge typically lasts 3 to 6 years, a shorter period if subjected to frequent outages or elevated temperatures. Battery replacement part for Back-UPS Pro 900 is APCRBC123. Please recycle spent battery cartridges. Service If the Back-UPS arrived damaged, notify the carrier. If the Back-UPS requires service, do not return it to the dealer. 1. Consult the Troubleshooting section to eliminate common problems. 2. If the problem persists, go to http://www.apc.com/support/. 3. If the problem still persists, contact APC Technical Support. Have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address. Warranty The standard warranty is three (3) years from the date of purchase, valid in European Community. For all other regions, the standard warranty is two (2) years from the date of purchase. APC s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer. APC Worldwide Customer Support Internet http://www.apc.com Worldwide +1 888 272-3858 Customer support and warranty information is available at the APC Web site, www.apc.com. 03/2010 APC by Schneider Electric. All trademarks are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. 990-3837A 3/2010