HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.



Similar documents
HS5E. Safety Door Lock Switches. Four-contact safety switch with solenoid interlock. Ideal for use on small doors within limited space.

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Safety detection solutions

Switches & Pilot Devices

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

LF1D/LF2D LED Illumination Units (Wide angle & high illuminance model)

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

48 SERIES Relay interface modules 10 A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Cross-beam scanning system to detect slim objects. 100 mm in

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

! WARNING. Before using product, read and understand instructions.

Manual motor starter MS116

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

RM4TG20 three-phase network control relay RM4-T - range V

Safety automation solutions

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Adjustment functions for both span and shift have been incorporated

U-shaped Micro Photoelectric Sensor

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Digital inductive conductivity transmitter

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RY2 miniature industrial relays

49 Series - Relay interface modules A. Features

R.C.C.B. s two-pole LEXIC

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

Machine Safety Switches

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

General 1-2-Opto-electronics Safety Switches 4-Emergency

400 Series Buccaneer BUCCANEER POWER. bulgin

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Thermal-Magnetic Circuit Breaker M1-..

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Electronic overload relay EF65, EF96 and EF146

Waterproof Connectors for Outdoor Use

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Installation Manual. BYD Wall-mounted AC Charging Box

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electronic overload relay EF19 and EF45

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ADM1TE 5/30A DIN rail single phase two wire energy meter

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

How To Read A Pipe From A Sensor

Safe switching and monitoring Solenoid Interlocks

picomax The Pluggable Connection System

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Plug and Socket Devices CES 63 A Series 8579

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

How To Use A Flowmeter

38 Series - Relay interface modules A

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

FP2 Relay. The Best Relaytion

Circuit Breakers. NRC Series. NRC Series

Safety dialogue solutions

E-STOP relays, safety gate monitors

CQM1-SF200/CS1W-SF200

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electro-pneumatic control valves

Surface Mounting Relay

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Electric Rotary Actuator - On/Off or programmable control actuator

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

TS93 EMR T/PT/TDE. Surface applied door closer

Miniature Safety Limit Switch

Capacitive Prox E2K-X

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

SPST-NO SPDT DPST-NO DPDT

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Solid-State Timer H3G

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

3 Port Solenoid Valve

Pluggable interface relays CR-P Pcb relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

38 Series - Relay interface modules A

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Transcription:

y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09)

New Generation Miniature Interlock Switches IDEC s new unique Head Removal Detection Function is a new generation technology that assures safety and satisfies international safety standards. Head Removal Detection Function All HS5D models are equipped with Head Removal Detection Function. When the head is removed, such as when the head is rotated, the main circuit (-) turns OFF. HS5D- When the actuator is removed or inserted, the operation of the main circuits (-, -) are the same. However, when the head is removed, disparity is detected (-: ON, -: OFF). The disparity of the contacts detects the removal of the head. Head removal detection function Main circuit (-) is removed is inserted Head is removed HS5D- When actuator is removed When actuator is inserted When head is removed Main circuit (NC) OFF ON OFF Main circuit (NC) OFF ON ON Note: Head removal detection function is not a direct opening action mechanism. Disparity Existing Interlock Switches When actuator is removed When actuator is inserted When head is removed Main circuit (NC) 3 4 OFF ON ON Monitor circuit (NC) OFF ON ON Small size with 3 contacts The HS5D is the same size (dimensions/mounting dimensions) as contact types (HS5B). 3 contact types with dual enabling contacts and a monitor contact are available. Compact size. Can be installed in narrow spaces. M3 terminal screws make wiring easy. Gold-plated contact suitable for small loads. s interchangeable with HS5B/HS5E s can be selected to suit door shapes and applications. Angle Adjustable Right-angle Straight Straight w/rubber bushing Right-angle w/rubber bushing Various Safety Product Accessories 9 mm Door Handle (HS9Z-DH5) Plug (HS9Z-A5P) mm mm Padlock Hasp (HS9Z-PH5) Sliding (HS9Z-SH5)

Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the HS5D is removed. The HS5D is the same size as contact type interlock switches (HS5B). 3 contact types with dual enabling contacts and a monitor contact are available. Can be installed in narrow spaces. (W D 9H mm) The actuator is interchangeable with HS5B and HS5E. Double insulation structure eliminates the need for grounding. The head orientation can be rotated, allowing 8 different actuator entries. Degree of protection (contacts): IP67 (IEC6059) NC contacts with direct opening action (IEC/EN60947-5-) Proprietary actuators prevent invalidation of the contacts (ISO49, EN088). M3 terminal screws for easy wiring. Gold-plated contacts suitable for small loads. Specifications ISO49 EN088 IEC60947-5- EN60947-5-(TÜV approval) Applicable Standards GS-ET- (TÜV approval) UL508 CSA C. No. 4 IEC604-/EN604- (applicable standards for use) Operating Temperature to +70 C (no freezing) Relative Humidity 45 to 85% (no condensation) Storage Temperature 40 to +80 C (no freezing) Pollution Degree 3 Impulse Withstand 4 kv Voltage Contact Resistance 50 mω maximum (initial value) Insulation Resistance (500V DC megger) Between live and dead metal parts: 00 MΩ minimum Between terminals of different poles: 00 MΩ minimum Electric Shock Protection Class Class II (IEC640) Degree of Protection IP67 (IEC6059) Shock Resistance Damage limits: 000m/s Operating extremes: Vibration Resistance 0 to 55 Hz, amplitude 0.5 mm Damage limits: Hz, amplitude.5 mm Operating Speed 0.05 to.0 m/s Direct Opening Travel 0 mm minimum Direct Opening Force 50N minimum Operating Frequency 900 operations per hour Mechanical Durability,000,000 operations minimum (GS-ET-) 00,000 operations minimum (AC- 50V, 6A) Electrical Durability,000,000 operations minimum (V AC/DC,00 ma) (operation frequency: 900 operations per hour) Performance of Terminals - of Removed Head Unit Mechanical damage limits: 0 operations min. Insulation resistance: 00 MΩ (initial value) Dielectric strength: 000V, minute (initial value) Conditional Short-circuit Current 00A (50V) (note) Weight (approx.) Plastic head: 80g Metal head: 0g Note: Use a 50V/0A fast-blow fuse as a short-circuit protector. Contact Ratings Rated Insulation Voltage (Ui) Thermal Current (Ith) 0V 0A Rated Voltage (Ue) V 5V 50V Resistive load (AC-) 0A 0A 6A Rated AC Inductive Load (AC-) 0A 5A 3A Current (Ie) * Resistive load (DC-) 8A.A.A DC Inductive Load (DC-3) 4A.A 0.6A Minimum applicable load (reference): 5V AC/DC, ma (Applicable range may vary with operating conditions and load types.) *TÜV rating: AC- 3A/50V, DC-3 4A/V Type No. Development Circuit Code : NO-NC 0: NC : NO-NC 03: 3NC Head Material blank: Plastic Z : Metal Parts Description Angle Adjustable (for hinged doors) Right-angle (SUS4) Straight w/rubber bushing HS5D- Z RN M (Use conduits or cable glands which can maintain IP67 protection.) blank: G/ P: PG3.5 M: M Head/Housing Color RN: Red/Gray M3 Terminal Screw Straight (SUS4) Right-angle w/rubber bushing 3

Miniature Safety Interlock Switch Package Quantity: NC-NO NC NC-NO 3NC Contact Configuration Zb 3 Zb Zb 33 34 Zb 3 3 Size Type No. (Ordering Type No.) Plastic Head Type Metal Head Type G/ HS5D-RN HS5D-ZRN PG3.5 HS5D-RNP HS5D-ZRNP M HS5D-RNM HS5D-ZRNM G/ HS5D-0RN HS5D-0ZRN PG3.5 HS5D-0RNP HS5D-0ZRNP M HS5D-0RNM HS5D-0ZRNM G/ HS5D-RN HS5D-ZRN PG3.5 HS5D-RNP HS5D-ZRNP M HS5D-RNM HS5D-ZRNM G/ HS5D-03RN HS5D-03ZRN PG3.5 HS5D-03RNP HS5D-03ZRNP M HS5D-03RNM HS5D-03ZRNM Package Quantity: Name Type No. (Ordering Type No.) Straight HS9Z-A5 Straight w/rubber bushings HS9Z-A5A Right-angle HS9Z-A5 Right-angle w/rubber bushings HS9Z-A5A Angle Adjustable (vertical/horizontal) Type HS9Z-A55 Accessories Package Quantity: Name Type No. (Ordering Type No.) Remarks Plug HS9Z-A5P Can also be used for HS5B and HS5E HS9Z-DH5RH Can also be used for HS5B and HS5E. For right-hand door. Handle Unit Door Handle Switch Cover Unit HS9Z-DH5LH HS9Z-DH5C Can also be used for HS5B and HS5E. For left-hand door. Used for installing the interlock switch inside. Can also be used for HS5B and HS5E HS5B/HS5D Installation Kit HS9Z-DH5B Used for mounting HS5B and HS5D Sliding HS9Z-SH5 Can also be used for HS5B and HS5E Padlock Hasp HS9Z-PH5 Can also be used for HS5B and HS5E Contact Configuration and Operation Chart Type Contact Configuration Contact Operation Chart (reference) Terminal Arrangement 0 ( Mounting Reference Position) Approx. Approx. 4.6 6.7 Approx. 6.4 (Travel: mm) HS5D-* - 3 3- : Contact ON (closed) : Contact OFF (open) : - HS5D-0* - - : - : 3-3 / : 33-34 HS5D-* HS5D-03* - - 33 34 33-34 - - 3 3 3-3 removed completely inserted completely The operation characteristics shown in the chart above are for the HS9Z-A5. For other actuator types, add.3 mm. The operation characteristics show the contact status when the actuator enters the entry slot of an interlock switch. 4

Dimensions and Mounting Hole Layouts HS5D- ZRN (Metal Head) With HS9Z-A5 Straight : Reference mounting position 8 6.4 6. Stop Metal Head Cover 4. 5. Plastic (red) Plastic (gray) 9 36 6.4 5. 6. to -M4 Screws Stop Metal Head Cover 8 6 ± Plastic (red) Plastic (gray) 9 Slot Plug (supplied) 6 ± Mounting Hole Layout With HS9Z-A5 Right-angle Metal Head Cover Plastic (red) Plastic (gray) 7.7 4.5 35.3 7.7 Metal Head Cover Plastic (red) Plastic (gray) Cover Stop Slot Plug (supplied) 7.6 ± 9 to -M4 Screws Cover Stop Mounting Hole Layout 7.6 ± 9 All dimensions in mm. HS5D- RN (Plastic Head) With HS9Z-A5 Straight 6.4 6. Plastic Head (red) 4. 5. Plastic (gray) 6.4 6. Plastic (gray) 36 5. Plastic Head (red) 8 8 Stop 9 Stop to -M4 Screws 6 ± 9 Slot Plug (supplied) 6± Mounting Hole Layout With HS9Z-A5 Right-angle Plastic Head (red) 7.7 4.5 Plastic (gray) 35.3 7.7 Plastic Head (red) Plastic (gray) Cover Stop Slot Plug (supplied) 7.6 ± 9 to -M4 Screws Cover Stop Mounting Hole Layout Note: Plug the unused actuator insertion slot using the slot plug supplied with the safety interlock switch. 7.6± 9 All dimensions in mm. 5

Dimensions Straight (HS9Z-A5) Right-angle (HS9Z-A5) Straight w/rubber bushing (HS9Z-A5A) 6. 5. 3.4 (6) 33 7. 7. 7.3 43.8.3 -ø4.3 Right-angle w/rubber bushing (HS9Z-A5A). (39.7) 8. 4-R 6.4 6 Stop 8 4.5 Stop -ø4.4.6 -ø0 Stop Washer (supplied with the actuator) Rubber Bushing (5) A Washer (supplied with the actuator) () -ø4.3 0 Mounting Hole Layout (Straight, Right-angle) 49 -M4 Screw Horizontal Swing 3 Orienting Insert Angle Adjustable (HS9Z-A55) Cover Angle Adjustment (M3 Hexagon Socket Head Screw) Stop º 3 6 38 (5) -ø9 Rubber Bushing.8 8.5 -ø9 -ø0 B Stop *The mounting center distance is set to mm at factory. When - mm distance is required, adjust the distance by moving the rubber bushings. A B : The actuator has flexibility to the directions indicated by the arrows. When -mm distance is selected, the actuator swings vertically. Mounting Hole Layout (Straight w/rubber bushing) (Right-angle w/rubber bushing) 7 8.5 9 Vertical Swing Orienting Insert Stop 3.6 R. (M4 Holes) -M4 Screw *Mounting centers can be widened to mm by moving the rubber cushions. Angle Adjustment (M3 Hexagon Socket Head Screw) º Mounting Reference Position As shown in the figure below, the mounting reference position of the actuator when inserted in the interlock switch is where the actuator stop placed on the actuator lightly touches the interlock switch. Note: After mounting the actuator, remove the actuator stop from the actuator. Mounting Hole Layout (horizontal/vertical swing) -M4 Screw 38 Interlock Switch Door Stop Interlock Switch Stop Interlock Switch Stop Note: The actuator stop is supplied with the actuator and used when adjusting the actuator position. Remove the actuator stop after the actuator position is determined. Stop HS9Z-A5 Door Stop Cover HS9Z-A5 HS9Z-A55 Orientation (Angle Adjustable) The angle of actuator swing can be changed using the orienting insert (white plastic) installed on the back of the actuator. Do not lose the orienting insert, otherwise the actuator will not operate properly. Safety Precautions In order to avoid electric shock or fire, turn the power off before installation, removal, wire connection, maintenance, or inspection of the interlock switch. If relays are used in the circuit between the interlock switch and the load, use only safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the interlock switch. Perform risk assessment and make up a safety circuit which satisfies the requirements of the safety category. For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the terminal screws to a recommended torque of 0.6 to N m. Improper soldering or failure to tighten the terminal screw may cause overheating and fire. Do not place a PLC in the circuit between the interlock switch and the load. Safety security can be endangered in the event of a malfunction of the PLC. Do not install the actuator in the location where a human body may come in contact. Otherwise injury may occur. Do not disassemble or modify the interlock switch, otherwise a malfunction or an accident may occur. 6

Instructions Regardless of door types, do not use the interlock switch as a door stop. Install a mechanical door stop at the end of the door to protect the interlock switch against excessive force. Do not apply excessive shock to the interlock switch when opening or closing the door. A shock to the interlock switch exceeding,000 m/s may cause damage to the interlock switch. Do not open the lid of the interlock switch. Loosening the screws may cause damage to the interlock switch. Prevent foreign objects such as dust and liquids from entering the interlock switch while connecting a conduit or wiring. Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Use proprietary actuators only. When other actuators are used, the interlock switch may be damaged. Mounting Examples Application on Sliding Doors of Hinged Door When using the interlock switch for a hinged door, refer to the minimum radius of doors shown below. For the doors with small minimum radius, use angle adjustable actuators (HS9Z-A55). Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A5 When the door hinge is on the extension line of the interlock switch surface: Minimum Radius 70 mm When the door hinge is on the extension line of the actuator mounting surface: Minimum Radius 90 mm Door HS9Z-A5 60 mm HS5D Interlock Switch Door Stop Application on Hinged Doors mm When using the HS9Z-A55 Angle Adjustable When the door hinge is on the extension line of the interlock switch surface: HS9Z-A5 Horizontal Swing Vertical Swing Door 50 mm 50 mm HS9Z-SH5 Sliding HS5D Interlock Switch Installing the Head Do not use the plastic and metal head of the HS5B interlock switches and metal head of the HS5E interlock switch on the HS5D. When using these HS5D and HS5E interlock switches adjacently, ensure that the heads are not interchanged. When the door hinge is on the extension line of the actuator mounting surface: Horizontal Swing 70 mm Vertical Swing 50 mm HS5D HS5E HS5B Plastic Head Metal Head Metal Head Metal Head Metal Metal (gray) Plastic (red) (silver color) (red) (black) Plastic Head Plastic (black or gray) Angle Adjustment for the HS9Z-A55 Using the angle adjustment screw, the actuator angle can be adjusted (see figures on page 6). Adjustable angle: 0 to The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. 7

Instructions Rotating the Head The head of the HS5D can be rotated by removing the four screws from the corners of the HS5D head and reinstalling the head in the desired orientation. When reinstalling the head, make sure that no foreign object enters the interlock switch. Tighten the screws tightly, because loose tightening may cause malfunction. Recommended screw tightening torque: 0.9 to 0. N m Applicable Crimping Terminal When using crimping terminals, be sure to install insulation tubes on the crimping terminals to prevent electric shocks. When using stranded wires, make sure that loose wires do not cause short circuit. Also do not solder the terminal to prevent loose wires. 7.4max. 4. to 5.8 Factory Setting Alternative Head Orientations Head Removal Detection Function Only the NC contact of the main circuit (-) turns OFF (open) when the head is removed, such as when rotating the head. Because NC contacts of other than the main circuit (-) turn ON (closed), be sure to connect the main circuit (-) to the safety circuit. Recommended Tightening Torque Interlock Switch Mounting Screw:.8 ±. N m (two M4 screws) Housing Lid Screw: 0. to 0.4 N m (M3 screw) Terminal Screw: 0.6 to N m (M3 screw) Connector:.7 to 3.3 N m s HS9Z-A5:.8 ±. N m (two M4 screws) HS9Z-A5: ±. N m (two M4 Phillips screws) HS9Z-A5A/A5A:.0 to.5 N m (two M4 screws) HS9Z-A55:.0 to.5 N m (two M4 screws) The above recommended tightening torques of the mounting screws are the values confirmed with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. Mounting bolts must be provided by the user. To avoid unauthorized or unintended removal of the interlock switch and the actuator, it is recommended that the interlock switch and the actuator be installed in an unremovable manner, for example using special screws or welding the screws. A ø3. Recommended manufacturer: JST Part No.: N0.5-3 Applicable wire size (with insulation tube): 0. to 0.5 mm Note: Do not remove screw A during wiring. Removing the screw may cause malfunction or damage. Applicable Wire Size 0.5 to.5 mm Applicable Cable Glands Use a cable gland with a degree of protection IP67. 9 max. G/, PG3.5, M When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (made by Nihon Flex) Size Plastic Cable Gland Metal Cable Gland G/ RLC-03 (Nihon Flex) PG3.5 RBC-03PG3.5 (Nihon Flex) M RLC-03EC (Nihon Flex) When Using Multi-core Cables (Example) Size Plastic Cable Gland Metal Cable Gland G/ SCS-0* (Seiwa Electric) ALS-6** (Nihon Flex) PG3.5 ST3.5 (LAPP) ABS-**PG3.5 (Nihon Flex) M ST-MX.5 (LAPP) ALS-**EC (Nihon Flex) Different cable glands are used depending on the cable sheath diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath diameter. When using a /-4NPT cable gland, use the HS5D interlock switch with M gland port (Type No.: HS5D- ***BM) together with an adaptor (Type No.: MA-M/NPT X.5 540-00, LAPP) and a gasket (Type No.: GP M, LAPP). Install a gasket between the interlock switch and the adaptor. Apply sealing tape between the cable gland and the adaptor to make sure of IP67 protection for the enclosure. max. 6.4 max. Specifications and other descriptions in this catalog are subject to change without notice. www.idec.com IDEC COORATION (USA) Tel: +-408-747-0550 / (800) 6-IDEC (433) Fax: +-408-744-9055 / (800) 635-66 E-mail: opencontact@idec.com IDEC CANADA LIMITED Tel: +-905-890-856, Toll Free: (888) 37-433 Fax: +-905-890-856 E-mail: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. Tel: +6-3-9763-34, Toll Free: 800-68-433 Fax: +6-3-9763-355 E-mail: sales@au.idec.com 7-3, Nishi-Miyahara -Chome, Yodogawa-ku, Osaka 53-8550, Japan Tel: +8-6-6398-57, Fax: +8-6-639-973 E-mail: marketing@idec.co.jp IDEC ELECTRONICS LIMITED Tel: +44-56-3000, Fax: +44-56-37755 E-mail: sales@uk.idec.com IDEC ELEKTROTECHNIK GmbH Tel: +49-40-5 54-0, Fax: +49-40-5 54 - E-mail: service@idec.de IDEC (SHANGHAI) COORATION Tel: +86--5353-000, Fax: +86--5353-63 E-mail: idec@cn.idec.com IDEC (BEIJING) COORATION Tel: +86-0-658-63, Fax: +86-0-658-59 IDEC (SHENZHEN) COORATION Tel: +86-755-8356-977, Fax: +86-755-8356-944 IDEC IZUMI (H.K.) CO., LTD. Tel: +85-803-8989, Fax: +85-565-07 E-mail: info@hk.idec.com IDEC TAIWAN COORATION Tel: +886--698-399, Fax: +886--698-393 E-mail: service@tw.idec.com IDEC IZUMI ASIA PTE. LTD. Tel: +65-6746-5, Fax: +65-6844-5995 E-mail: info@sg.idec.com Cat. No. EP85- MARCH 0 4S PRINTED IN JAPAN