Structural Timber Association Building Low Carbon Timber Frame Homes



Similar documents
Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Module 3.7. Thermal bridging

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Rev Code of Practice. SIP Technology.

TGD L Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Multi-layer Insulation Blanket for Roofs

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

ROOFS, SNOW AND ICE DAMS

2014 British Columbia Building Code Changes

Providing protection in construction

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Avoiding Air Barrier Pitfalls

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Building Regulations for the Conservation of Fuel and Power

Rockwool Flexi Insulation Application Guide

Continuous Insulation Using Polyiso Wall Sheathing

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Residential Refurbishment. September ThermoShell Internal Wall Insulation System Design Guide

Performance of 8 Passive House Envelopes in Cold Climates

Internal wall insulation in existing housing

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

SIP (STRUCTURAL INSULATED PANEL)

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Timber Frame Walls Rethinking Construction

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Window Sill Details for Effective Drainage of Water

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

CONDENSATION IN REFRIDGERATED BUILDINGS

Post-insulation of cellar ceiling and cellar walls

WALLS Three common wall types are described below, with their insulation solutions.

The Case for Cross Laminated Timber: Part 2

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

The Kingspan Insulation Price List 1 st January 2013

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

Energy Company Obligation (ECO): Technical Monitoring Questions

Manual lifting and handling

Including. Rubershield-Pro. Breather Membrane

HUNTON BITUMEN IMPREGNATED BOARDS HUNTON BITROC SHEATHING BOARD

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

EcoTouch Insulation with PureFiber Technology

Sixth Issue March Kingspan. Building System. CERTIFICATE No. 02/0158. Low Energy - Low Carbon Buildings

Comment Form on Proposed Gut Rehabilitation Alternatives

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

A practical guide to building airtight dwellings

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Preventing Ice Dams on Roofs

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

How To Repair A Boat Landing Deck With A Boat Bed

ETHICS. WP 7: Design Guidance on energy and thermal improvements for non-residential buildings

Rockwool Cladding Roll

- Version 2 Total R-value calculations for typical building applications

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

BER Assessors Dwellings Technical Bulletin

Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE

DEFAULT HEAT LOSS COEFFICIENTS

Timber frame structures platform frame construction (part 1)

Roofers Guide to Underslating Membranes

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Bituminous Sheet Flat Roofs: Their repair and maintenance

Guide to the safe installation of downlighters in dwellings

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Roof Insulation Building. Energy. Environment friendly e-library

The Real Value of Space

TIMBER FRAME STANDARD DETAILS SEPTEMBER 09

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

2009 Seattle Energy Code Impacts: See below for a recap of Changes in Envelope performance from 2006 to 2009

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE

IECC Compliance Guide for Homes in Virginia

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

Affordable Zero Energy

Energy Efficient Windows

Insulating Basements: Part 3 Basement Wall Systems

Improving thermal insulation of concrete sandwich panel buildings

Coventry Senior Living

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

What s Wrong with this Project? Report

fire separating walls #2

Conservatory warm roof conversion system

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

PROFILED METAL ROOFING DESIGN GUIDE

DESIGN AS-BUILT PERFORMANCE

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

Transcription:

Structural Timber Association Building Low Carbon Timber Frame Homes

STA what we do TRADE BODY for - Timber Frame SIPS- CLT- Glulam Engineered wood products (see www.structural timber.co.uk for more information)

This presentation is all about Timber Frame Understanding Design Detail Principles To deliver: Low Carbon Homes

What are the aims of this presentation? Support o The delivery of Zero Carbon Homes o The deliver current Part L Regs - FEE o Encourage good practice construction by project team understanding.

Back ground BUILDING IN TIMBER FRAME Timber Frame Timber Frame - Low embodied energy material - Renewable resource - Design versatile and flexible

Back ground - Structural Timber Solutions The basic - Open timber frame panels Sheathing Stud Insulation Cavity Plasterboard

Back ground Solutions IN TIMBER FRAME The Wall C B A D E External wall A) Stud width options B) Breather paper options C) Insulation options- between studs: Wool types Rigid foam Multi foils D) Service zones & / or combinations E) Additional internal over-lay board, or laminate plasterboard B A D C E

Back ground - Solutions IN TIMBER FRAME

Back ground - energy efficiency is more then U values FEE influenced by: Building fabric U- values Thermal bridging Air permeability Thermal mass External heat gain (solar) Internal heat gain

Key Issues to consider for improved performance - Better detailing KEY ISSUES: Thermal Performance - Good quality workmanship - Sequencing of works Thermal Bridging Thermal Bypass Sequencing Recognition and understanding

Key issue Thermal Performance Thermal Performance. The U-value- All materials in the building element are taken into account. Thermal Mass Plus - Minus. Heat loss through a wall. Increased levels of insulation will reduce the rate of heat loss. Insulation Air Flow Air Flow Thermal Bridge Heat Transfer

Key Issue Thermal Bridging Thermal bridges points in the envelope where heat loss is greatest. Impossible to avoid all thermal bridging,but can be minimised. Potential for thermal bridge through window head Increased Bridging caused by poor workmanship, Insulation Air Flow Air Flow Thermal Bridge Heat Transfer

Key Issue Thermal Bypass Thermal bypass - movement of unheated air through spaces in the building fabric = heat loss. Air tight layer follow insulation The thermal bypass can occur when the airtightness barrier does not follow the insulation. Insulation Air Flow Air Flow Thermal Bridge Heat Transfer

Key Issue Air leakage =loss of internal heated air = fuel use. barrier the building envelope component which provides an airtight seal. Air leakage can occur around badly fitting components such as window frames. Air leakage / not ventilation - Controll ventilation by a natural or mechanical means. Insulation Air Flow Air Flow Thermal Bridge Heat Transfer

Key issue Sequencing Out-of-sequence work Prevent other work stages damaging previous work that has already been done. Cause defective airtightness and thermal performance of the building envelope. Key stage inspections Before: After: A services typical wall installation with continuous through insulation the wall and results airtightness in a difficult-to-seal barrier. air leakage path. Early co-ordination is important. Insulation Air Flow Air Flow Thermal Bridge Heat Transfer

Common Issues Good practice principles Thermal Performance Analyse details at design stage. Additional insulation to fill voids. Avoid displacing insulation within studs.. WALL JUNCTION: EXTERNAL WALL UPPER FLOOR Timber fraction included in calculations.

Common Issues Good practice principles Thermal Bridging Account for thermal in calculations Continuous insulation layer. Thermally efficient cladding support. ROOF: EAVES COLD ROOF Check bridging at large structural elements

Common Issues Good practice principles Thermal Bypass Check no voids between heated spaces and the line of insulation. barrier follows the inside line of the insulation layer. Seal floor voids from vertical cavities. Full fill insulation in party walls if possible. Seal cavities to prevent air movement ROOF: PARTY SEPARATING WALL COLD ROOF

Common Issues Good practice principles Continuous airtightness barrier. Service void to the inside the face of the frame. Avoid interstitial condensation. WINDOW: WINDOW HEAD Adhesive tapes, or bonded to substrate.

Common Issues Good practice principles Sequencing Co-ordinate the airtightness line. Anticipate service penetrations - gaps are sealed. Pressure testing at different stages of construction. GROUND FLOOR: INTERNAL LOADBEARING WALL - GROUND FLOOR Key for following details Insulation Line of airtightness barrier Physical membrane of airtightness barrier

Diagrammatic Example : Ground Floor external GROUND FLOOR 01: EXTERNAL WALL - GROUND FLOOR Thermal insulation to be continuous. Additional insulation to inner leaf reduces thermal bridge at junction of timber frame and masonry. Maintain continuity of airtightness barrier at floor/wall junction with lapped and sealed joints. Thermal Bypass Sequencing barrier should coincide with insulation to avoid thermal bypass. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Diagrammatic Example : Ground Floor party wall GROUND FLOOR 02: INTERNAL LOADBEARING WALL - GROUND FLOOR Full fill insulation to party wall cavity to avoid thermal bypass. Maintain continuity of airtightness barrier at floor/wall junction with lapped and sealed joints. Thermal Bypass Seal base of party wall cavity before floor and walls are installed, to prevent thermal bypass. Sequencing Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Diagrammatic Example : Window cill WINDOW 01: WINDOW CILL Additional seals between airtightness barrier and window frame to maintain airtightness. Insulation below frame and internal cill to minimise thermal bridging. Window aligned in wall to maintain thermal continuity. Thermal Performance Thermal Bridging Insulated cavity closer instead of timber to reduce the extent of thermal bridging. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Diagrammatic Example: Window jamb WINDOW 03: WINDOW JAMB Additional seals between airtightness barrier and window frame to maintain airtightness. Insulation between frame and wall to minimise thermal bridging. Window aligned in wall to maintain thermal continuity. Insulated cavity closer instead of timber to reduce the extent of thermal bridging. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Common Issues: Warm Roofs ROOF 01: EAVES WARM ROOF Thermal insulation to be continuous. Additional insulation within eaves construction. barrier should be adjacent to insulation to avoid thermal bypass. barrier to be continuous with sealed laps between wall and roof construction. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Common Issues: Cold Roofs ROOF 04: EAVES COLD ROOF Thermal insulation to be continuous. Additional insulation within eaves construction. barrier should be adjacent to insulation to avoid thermal bypass. barrier to be continuous with sealed laps between wall and roof construction. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Diagrammatic Example : Wall Junctions WALL JUNCTION 01: EXTERNAL WALL UPPER FLOOR Thermal insulation to be continuous. Additional insulation within floor construction at junction with wall. barrier to be continuous at junction. Joints to be lapped and sealed. Careful choice of membrane at junction. Co-ordinate airtightness barrier with installation of floor. WALL JUNCTION 03: INTERNAL WALL/EXTERNAL WALL DETAIL Maintain airtightness where internal studwork meets the external wall. If airtightness is being provided by membrane this is best installed before internal studwork. Where insulation reduces in depth ensure that it is installed correctly and cut to match space available. Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Summary Fabric Energy Efficiency in Timber Frame Key Issues Common Issues KEY ISSUES: Thermal Performance Thermal Bridging Thermal Bypass Sequencing

Further Information Structural Timber Association www.structuraltimber.co.uk Fabric First www.fabricfirst.co.uk Zero Carbon Hub www.zerocarbonhub.org National House-Building Council www.nhbc.co.uk Building Low Carbon Homes (Guide) http://www.structuraltimber.co.uk download-documents Fabric Energy Efficiency for Zero Carbon Homes (Guide) www.zerocarbonhub.org/resources