BDI-FLX BURST DISC SENSOR SYSTEM BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS



Similar documents
B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Technical Data. Dimensions

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. Dimensions

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Centro-Matic Automatic Lubrication Systems System Controls

Inductive sensor NI10-M18-Y1X-H1141

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

WD-AMX Water Detection Controllers

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Worcester DS/DM Series UltraSwitch Switch box

Plug and Socket Devices CES 63 A Series 8579

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Scraper Passage Indicator. Electrical Indicator. Features

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Solenoid Valve Island Type 3965

Electronic, Digital and Mechanical Vibration Switches

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Today's world of increasing

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Flow switches Series AD/VH

Compact pressure switch Flameproof enclosure Ex d Model PCA

3500/62 Process Variable Monitor

Plug and Socket Devices SolConeX 16 A Series 8570

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Contents. Document information

48 SERIES Relay interface modules 10 A

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Flow Switches

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

2.12. page Products for Explosion hazardous Environment

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Solid State Timers Type F

Sanitary Type Electronic Flow Switches

Plastic tube flowmeters Series PT/PS

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Operating Instructions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Intrinsically Safe Barrier Relays NY2 and 8501TO

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

3500/40M Proximitor* Monitor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Cable Plug acc. to DIN EN , Form A

3DLevelScanner II TECHNICAL DATA SHEET

40.3. Control Relays and Timers

Flameproof Audible Signal 115 db (A) Series YA90

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

PRODUCT PROFILE FEATURES

8146/5 Series Breaker Panelboards

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Triple Waveband Infra-Red Flame Detection

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

D287/D288/D292/D293A/D293E

Modular I/O System Analog and Digital Interface Modules

Series 8146/5-V37 and Series 8150/5-V37

Medical Air Systems: Scroll

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

MS41-22Ex0-R/24VDC MS41-22Ex0-R/115VAC MS41-22Ex0-R/230VAC

3500/93 System Display

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Dynamic Pressure Charge Amplifier

Linear Luminaire with LED Series EXLUX 6402/2

49 Series - Relay interface modules A. Features

mpm DIN CONNECTORS

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Instructions for Safe Use

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

3/2-way Solenoid Valve, direct-acting, NC or NO

Transcription:

BDI-FLX BURST DISC SENSOR SYSTEM AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS The BDI-FLX Burst Disc Sensor System utilizes an electronic instrument which provides instantaneous notification of the bursting of a rupture disc using versatile interface cable options. When combined with an alarm monitor, this system provides protection for lives, equipment and the environment. Designed for use with ASME and DIN flanges 1-12 (25mm-300mm) or sanitary applications 1-4 (25mm-100mm), the BDI-FLX Burst Disc Sensor System utilizes a sensor strip with a flexible potentiometer (electrical component that varies resistance in response to deflection) to signal a rupture disc has burst. BENEFITS The BDI-FLX Burst Disc Sensor System provides many benefits, which include: Allows direct interface to PLC s, DCS (Distributed Control Systems), alarm monitors or isolating barriers and can provide dry contacts for industrial controls Figure 5 Improved durability: The conductive element is fully encapsulated in corrosive resistant polyimide film The advanced technologies of the sensor strip minimize the risk of damage due to excessive stress beyond recommended bolting load The alignment ring provides a rigid support for the sensor cable, minimizing cable strain Modernized output cable connectors in accordance with IEC 61076-2- 101. IP67 rated M12 connector. BDI-FLX The BDI-FLX sensor is installed at the downstream side of a rupture disc, bolted between the rupture disc holder and flange or sanitary ferrule as shown: FIGURE 1 OUTLET COMPANION FLANGE BDI-FLX SENSOR LABEL BDI-FLX SENSOR RUPTURE DISC & HOLDER ASSEMBLY INTEGRAL BDI-FLX INSTALLATION INLET GASKET INLET COMPANION FLANGE BDI-FLX BURST DISC SENSOR SYSTEM FLOW INSTALLATION OF THE BDI-FLX BURST DISC SENSOR SYSTEM

BDI-FLX DATASHEET // PAGE 2 MAIN COMPONENTS OF THE BDI-FLX SENSOR SYSTEM The BDI-FLX Burst Disc Sensor System is comprised of two main assemblies: the BDI-FLX Sensor and BDI-FLX Interface Cable as shown below: FIGURE 2 BDI-FLX Sensor FLUOROPOLYMER MEMBRANE METAL RING SENSOR CABLE SENSOR STRIP GASKET (on each side) SENSING ELEMENT INTEGRAL BDI-FLX Sensor FLUOROPOLYMER MEMBRANE GASKET SENSOR CABLE Interface Cable PRE-AMP CABLE OUTPUT CABLE M12 CONNECTOR INTERFACE MODULE SENSING ELEMENT SENSOR STRIP SANITARY BDI-FLX Sensor CDC Alarm Monitor FLUOROPOLYMER MEMBRANE GASKET SENSOR CABLE SENSING ELEMENT SENSOR STRIP BDI-FLX BURST DISC SENSOR SYSTEM INFORMATION AVAILABLE ON PAGES 6 & 7 SENSOR FEATURES INDUSTRIAL APPLICATIONS BDI-FLX SANITARY APPLICATIONS INTEGRAL BDI-FLX SANITARY BDI-FLX One-time use Sensor Assembly Configurable for all BDI-FLX Model Interface Cable Assemblies Temperature: -40 F to 400 F (-40 C to 204 C) 1 Available for Industrial and Sanitary applications Figures 3, 4 Integral for SANITRX HPX, SANITRX HPX II & SANITRX LPX (2-3 only) Rupture Discs Standard 1.5 ft (0.45 m) long, shielded blue cable with M12 connector. The M12 connector ensures a secure connection to the interface cable. The connector can be easily disconnected and reconnected by the user for replacement of the disposable sensor. The M12 meets an IP67 rating. SENSOR NOMINAL SIZES & ACTIVATION PRESSURES FIGURE 3 FIGURE 4 BDI-FLX NOMINAL SIZE MINIMUM PRESSURE 2 in mm psig barg 1 25 5 0,35 1 ½ 40 4 0,28 2 50 3 0,21 3 80 2 0,14 4 100 2 0,14 6 150 2 0,14 8 200 2 0,14 10 250 2 0,14 12 300 2 0,14 SANITARY/INTEGRAL NOMINAL SIZE MINIMUM PRESSURE 2 in mm psig barg 1 25 25 1,72 1 ½ 40 10 0,69 2 50 5 0,34 3 80 2 0,14 4 100 1 0,07 1 Temperature limits may vary based on gasket material 2 Minimum pressure is based on PSIG values. BARG values are provided for reference.

BDI-FLX DATASHEET // PAGE 3 INTERFACE CABLE FEATURES Reusable assembly Routes electric power to the sensor Figures 2, 5 Monitors sensor strip resistance for rupture disc status Transmits output signal to user s system Figure 5 Temperature limits: -40 F to 158 F (-40 C to 70 C) 6 ft long (1.8 m) shielded pre-amp cable with M12 connector and 6 ft long (1.8 m) shielded output cable with bare lead ends (12 ft or 3.6 m total length) INTERFACE CABLE MODEL OPTIONS Interface Cable // Model 2W-IS 2W-IS MODEL Two-wire intrinsically safe design for use with a customer s safety barrier or the CDC MTB-700 Monitor Certified for ATEX (EU) & IECEx (International) for Zone 0 Group IIC and Zone 20, Group IIIC Certified for UL and c UL for Class I, Div 1 Group A, B, C, D; Class II, Div 1 Group F, G and Class III, Div 1 Interface Cable // Model 2W-NIS 2W-NIS MODEL Two-wire non-intrinsically safe design for use with PLC and DCS discrete input switching Powered from PLC or DCS or other suitable load that is in-series connected to DC power, no separate power input wiring is required Listed by UL and cul under Process Control Equipment Category Interface Cable // Model 4W-NIS 4W-NIS MODEL Four-wire non-intrinsically safe design with dry contact switching for non-classified (non-hazardous) locations Provides a single-pole single-throw (SPST) normally closed relay output signal Power-isolated switch output and switching capacity for DC and AC voltage Output available for PLC, DCS, interposing relays, alarm systems and actuator elements Listed by UL and cul under Process Control Equipment Category Best suited for non-hazardous applications that require full isolation for additional safety and where users are not limited to using two-wire connection

BDI-FLX DATASHEET // PAGE 4 INTERFACE CABLE SPECIFICATIONS & CERTIFICATIONS FIGURE 5 INTERFACE CABLE SPECIFICATIONS & CERTIFICATIONS MODEL 2W-IS 2W-NIS 4W-NIS OPERATION Normally Closed Normally Closed Normally Closed INTRINSICALLY SAFE ATEX II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135ºC Da No No LOAD TYPE Safety Barrier Switching Amplifier PLC/DCS discrete input Resistive or Inductive load, e.g., PLC/DCS, relay, etc OPERATING VOLTAGE 6 ~ 12 VDC 7 ~ 30 VDC 6 ~ 28 VDC OUTPUT SIGNAL TYPE 2-Wire electronic switch (power input and signal output share the same 2-wire cable) 2-Wire electronic switch (power input and signal output share the same 2-wire cable) Reed relay switching dry contact OUTPUT LEVEL SWITCHING ON 4.5 ma typical 2.5 ma MIN 4.85 ma MAX 12 ma typical 10.5 ma MIN 12.5 ma MAX Max switching power: 3VA Max carry current: 250 ma Max switching voltage: 60 VDC or 30 VAC OUTPUT LEVEL SWITCHING OFF 0.85 ma MAX 0.85 ma MAX Open Contact CE MARK Yes (under the ATEX Directive) Not Required Not Required UL / cul MARK* Yes Class I Div 1 A,B,C,D Groups Class II Div 1 F,G Groups Class III Div 1 Yes UL File# E350819 Yes UL File # E350819 IECEx Ex ia IIC T4 Ga Ex ia IIIC T135 C Da No No ALARM MONITOR OPTIONS MTB-700 Yes No Yes** BB-100A No No Yes** BB-400A No No Yes** * UL and cul marks indicate compliance with USA and Canadian product safety standards ** The BDI-FLX 4W-NIS model can work with any of our monitor models if separate input power is provided. However, the 4W-NIS is NOT for intrinsically safe applications and is not recommended for use in hazardous locations.

BDI-FLX DATASHEET // PAGE 5 BOLTING CLASSES & GASKET MATERIALS/TEMPERATURES Bolting classes for the BDI-FLX Sensor and gasket materials & temperatures for the Sanitary BDI-FLX Sensor are as follows: BOLTING CLASSES // INDUSTRIAL APPLICATIONS SIZE BOLTING CLASS in mm ASME DIN 1 25 150#, 300#/600# PN 10/40 1½ 40 150#, 300#/600# PN 10/40 2 50 150#, 300#/600# PN 10/40 3 80 150#, 300#/600# PN 10/40 4 100 150#, 300# PN 10/16 6 150 150#, 300# PN 10/16 8 200 150#, 300# PN 16 10 250 150#, 300# PN 16 12 300 150#, 300# PN 16 FIGURE 6 ADDITIONAL BOLTING CLASSES ARE AVAILABLE UPON REQUEST GASKETS // INDUSTRIAL APPLICATIONS THE BDI-FLX Sensor is available with non-asbestos or fiber reinforced fluoropolymer gaskets. GASKET MATERIALS & TEMPS // SANITARY APPLICATIONS FDA AND USP CLASS VI COMPLIANT GASKET MATERIALS SERVICE TEMPERATURES MINIMUM FIGURE 7 MAXIMUM F C F C Peroxide Cured Silicone -80-62 450 232 Platinum Cured Silicone -80-62 350 177 White VITON -20-29 400 204 Black VITON -20-29 400 204 White EPDM -55-48 275 135 Black EPDM -55-48 275 135 PTFE Fluoropolymer -40-40 450 232 Gaskets designed for use in ferrule connections having ASME-BPE dimensions or equivalent. Gaskets for use on Sanitary BDI-FLX installations not integral to the rupture disc.

BDI-FLX DATASHEET // PAGE 6 CONTINENTAL DISC ALARM MONITORS BDI-FLX SENSOR SYSTEM, INCLUDING ALARM MONITOR A continuous signal flows between the BDI-FLX Burst Disc Sensor System and the Alarm Monitor under normal conditions. Once the rupture disc bursts, the BDI-FLX Sensor System indicates the event, opening the electrical circuit. NOTE: If the BDI-FLX Burst Disc Sensor System loses power, it defaults to an open circuit. Continental Disc Alarm Monitors contain replaceable modules with individual channel relays. Each channel relay connects to one BDI-FLX Sensor System. As the rupture disc bursts and the BDI-FLX Sensor System indicates the event, a specific relay is actuated, sending a signal to the control panel. Control panels, annunciators, light panels or other signalling devices can be used to warn of a ruptured disc. The BDI-FLX Sensor System has the versatility to adapt to a variety of warning devices. The individual relay circuitry will allow the user to monitor several BDI-FLX Sensor Systems simultaneously. Pumps, valves and other systems may also be activated to respond to an overpressure situation by the indication of a specific BDI-FLX Burst Disc Sensor System.

BDI-FLX DATASHEET // PAGE 7 CONTINENTAL DISC ALARM MONITOR OPTIONS AVAILABLE ALARM MODELS DISCREET CHANNELS AVAILABLE FIGURE 8 MTB-700 BB-100A BB-400A 2 or 4 2 8 AUDIO / VISUAL ALARMS PROVIDED DRY CONTACTS FOR REMOTE ALARMS OUTPUT RELAY TYPE RELAY MAX CURRENT INTRINSICALLY SAFE* FIELD CIRCUIT BARRIER TYPE Optional NO NO YES YES YES DPDT Form C SPDT Form C SPDT Form C 5 A @ 240 VAC Resistive 5 A @ 24 VDC Resistive 1/8 HP @ 120/240 VAC, 7 A maximum carry current 2 A @ 120 VAC Resistive 1 A @ 120 VAC Inductive 2 A @ 24 VDC Inductive 2 A @ 120 VAC Resistive 1 A @ 120 VAC Inductive 2 A @ 24 VDC Inductive YES NO* NO* galvanically isolated zener diode zener diode ENCLOSURE RATING NEMA 4, 4X, 12, 13 NONE NONE OPERATING TEMPERATURE RANGE -4 F to +113ºF (-20ºC to +45ºC) -40ºF to +104ºF (-40ºC to +40ºC) -40ºF to +104ºF (-40ºC to +40ºC) RESET MODE (LATCHING, NON-LATCHING) OUTPUT CURRENT latching only either available either available 7 VDC @ 22 MA 6 VDC @ 0.1 MA 6 VDC @ 0.1 MA INPUT POWER OPTIONS 120/240 VAC, 50/60 Hz 24 VDC +/- 2 V 115/230 VAC 50/60 Hz 12 VDC +/- 1 V 115/230 VAC 50/60 Hz 12 VDC +/- 1 V REMOTE MASTER TEST CONTACTS YES NO NO REMOTE MASTER RESET CONTACTS YES YES YES BARRIER CERTIFICATIONS BDI-FLX ALARM MONITOR OPTIONS FM, ATEX, CSA, IECEx None None 2W-IS 4W NIS** 4W NIS** * Intrinsically Safe is defined as: Apparatus, including wiring, in which any spark or thermal effect produced either normally or in specified fault conditions... is incapable under test conditions of causing ignition of a specified mixture of flammable or combustible material in air. ** The BDI-FLX 4W-NIS model can work with any of our monitor models if separate input power is provided. However, the 4W-NIS is NOT for intrinsically safe applications and can NOT be used in hazardous locations.

CERTIFICATIONS Available When Specified Pressure Equipment Directive C LISTED US BDI-FLX DATASHEET // PAGE 8 Rupture Disc Selection RUPTURE DISC SELECTION All BDI-FLX Burst Disc Sensor System models can be used with the following rupture disc types, installed in insert type holders for 1 through 12 sizes: ATEX Directive Compliant HPX HPX-Ta LOTRX MICRO X COMPOSITE STANDARD All Sanitary and Integral BDI-FLX Burst Disc Sensor System models can be used with the following rupture disc types: SANITRX HPX SANITRX HPX II SANITRX LPX (2-3 only) FOR MORE INFORMATION ON OUR OTHER BURST DISC INDICATION PRODUCTS, PLEASE SEE THE B.D.I. BURST DISC INDICATOR DATASHEET. HEADQUARTERS // 3160 W. Heartland Drive Liberty, MO 64068 USA Ph (816) 792 1500 Fax (816) 792 2277 sales@contdisc.com contdisc.com THE NETHERLANDS Energieweg 20 2382 NJ Zoeterwoude-Rijndijk The Netherlands Ph +(31) 71 5412221 Fax +(31) 71 5414361 cdcnl@contdisc.com CHINA Room 1312, Tower B, COFCO Plaza No. 8 JianGuoMenNei Avenue Beijing (10005), P.R. China Ph +(86) 10 522 4885 Fax +(86) 10 6522 2885 cdcchina@contdisc.com INDIA 423/P/11, Mahagujarat Industrial Estate, Moraiya, Sarkhej-Bavla Road, Ahmedabad (GJ) 382213 INDIA Ph +(91) 2717 619 333 Fax +(91) 2717 619 345 gcmpl@contdisc.com Continental Disc Corporation reserves the right to alter the information in this publication without notice. // 2014 Continental Disc Corporation Reproduction without written permission is prohibited. PRINTED IN U.S.A. TCH1284 TMR // 1214