TABULA. The Absolute Switchboard System for Maximum Safety and Reliability



Similar documents
Low Voltage Switchboards The Best Technical Solution for Your Ship

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Securing your electrical installations Prisma,

SIVACON The Versatile Low-Voltage Switchboard

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

SIVACON Low Voltage Switchboard

Unified requirements for systems with voltages above 1 kv up to 15 kv

Modis 25/32. Modular Switchboard Solution

MNS is Switchgear System Technical Overview

The power distribution board that sets new standards

5SV Residual Current Protective Devices

P System Cubicles. Certified for more safety

Automation Products. Low Voltage Switchgear MNS System Overview

Technicaldata General

Comparative study for cables and busbars

FAQs-Main switchboard design criteria

Nothing s BetterThan the Original MODAN Power Distribution Systems

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

More than just OK. Okken: Low voltage switchboard for electrical distribution and motor control

MNS Low Voltage Switchgear System Guide

Electronic overload relay EF19 and EF45

low voltage switchgear

IEC & 2 standard. The reference for safe and reliable LV switchboards

The Intelligent AX1 Switchgear for Medium Voltage

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Manual motor starter MS116

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Electronic overload relay EF65, EF96 and EF146

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

GE Power Controls. MiniFORM Switchboards

Standard-compliant switchgear and controlgear production

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

3K Load-Break Switches The Program for Safety and Performance. sentric

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

TriLine ASSEMBLY System PowerModules

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

R.C.C.B. s two-pole LEXIC

The complete range of consumer switchboards and switchgear

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Technical Application Papers No.11 Guidelines to the construction of a low-voltage assembly complying with the Standards IEC Part 1 and Part 2

DEVICES OF PROTECTION AND COMMAND

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SURGE PROTECTIVE DEVICES

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

UFES Active protection for switchgear

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Changing industry standards: friend or foe?

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Manual Motor Starter MS 116 up to 16 A Technical Data

INTERNATIONAL STANDARD

Providing Consulting Engineers and Switchboard Builders the BUILDING BLOCKS for advanced & cost effective solutions TECHNO MODULAR SWITCHBOARD SYSTEM

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Low Voltage Products. Switches Automatic Transfer Switches

Advantages of Fixed Circuit Breaker Switchgear

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Disconnectors and Earthing Switches 36 kv up to 800 kv

Switchboard system. NorLine 800

Switchgear and Metal-Enclosed Bus

Alternate Methods to Short Circuit Breaker Coordination

How To Build A Low Voltage Capacitor Lvcp

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

know-how Giant in distributing electricity for industry Prisma GK

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

IEC specifications for LV assembly switchboards

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Relay mounting systems

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Secondary Unit Substations

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Type: DILM32 10(24V50HZ) Article No.:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

E-STOP relays, safety gate monitors

ADM1TE 5/30A DIN rail single phase two wire energy meter

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

BETA Protecting SITOR Semiconductor Fuses

Transcription:

TABULA The Absolute Switchboard System for Maximum Safety and Reliability

TABULA - A Qualified Partner with a Strong Switchboard Concept, World-Wide TABULA meets all requierements within low voltage switchboards: Main- and distribution boards Motor Control Centres Operation- and Control Switchboards Fulfils in the best way all national and interanational standards, incl. Approvals from international bureaus of shipping classifications, and is adaptable to almost any local demand and tradition.

TABULA Covers the Full Range of Low Voltage Switchboards Main Distribution Board Motor Control Centre, Draw-out

TABULA Covers the Full Range of Low Voltage Switchboards Distributions Board Operation- and Control Board

Strong data - without Compromises Fully documented low voltage switchboard system, acc. to IEC/EN 60439-1 og 3 Rated insulation voltage: 1000V Rated current Horizontal main busbars 250-7800A Vertical distributions busbars 225-1600A Short Circuit Ratings Horizontal main busbars up to 115kA/1s., 253 ka peak Vertical distribution busbars up to 91kA/1s., 200 ka peak Degree of protection IP20-IP54 Forms of separation, form 1-4 a as standard Fixed and draw-out execution

Typetestet - Point by Point Typetests includes: a) Verification of temperature rise-limits 8.2.1 b) Verification of dielectric properties 8.2.2 c) Verification of short-circuit withstand strength 8.2.3 d) Verification of the continuity of the protective circuit 8.2.4 e) Verification of clearances and creepage distances 8.2.5 f) Verification of mechanical operation 8.2.6 g) Verification of the degree of protection 8.2.7 h) Verification of construction and marking 8.2.8 i) Verification of impact strength 8.2.9 j) Verification of resistance to rusting and 8.2.10 to humidity 8.2.13 k) Verification of resistance of insulating material to heat 8.2.11 l) Verification of resistance of insulating materials to 8.2.12 abnormal heat and to fire due to internal electric effects. m) Verification of mechanical strength of fastening means 8.2.14 of enclosure. A natural element in the philosophy behind TABULA Typetest includes both IEC/EN 60439-1 as well as 60439-3 (switchboards operated by layman) Carried through in international test laboratories, KEMA, ASTA m.fl. Typetest certificate from DNV The extensive documentation is available for the panelbuilders (h, i, j, k, l, m, Only valid for panels operated by layman, and for max. outgoing current rating of 125A, and max incomming current rating of 250A. In accordance to IEC 60439-3)

The Realized Idea Fully modulated with a DIN-standardized basic module of 126mm (DIN-norm 125mm +/- 1mm) Optimum dimensions for any switchboard solution Is adaptable to any demands regarding switchboard location in the building Optimized utilisation of enclosure space Ensures easy and standardized extension possibilities

Busbar System Individual enclosed conductors in main busbar system, rated up to 2500 A Screen protected in cable compartment Close design Prepared for extensions Eliminates exposure of electrical arcs

Busbar System Main Busbars 3000 A Close design, parallel leaved conductors - minimizes magnetic fields Prepared for extensions Flexible connection by transport sections Busbar supports act as barriers to prevent the spread of arcs L1 L2 L3 N L1 L2 L3

Busbar System Connections Easy to connect Flexible and easy to extend Maintenance free acc. to. DIN 43671 Flat - quick connections by 225 Amp busbars - 30 years of experience No drilling by extensions

Build-In Typetested Standard Solutions ACB s MCCB s Fuse- and load break switches Draw-out Semi draw-out DIN-rail assemblies

Cable Compartments Separate cable compartments of any width and any position for optimum cabling 378 mm 504 mm

Internal Forms of Separation Internal Forms of Separation, Form 4a Main Busbars Distr. Busbars Incoming and outgoing functional units Terminals for external conductors Forms of separation are to be agreed upon between the panel-builder and the enduser The evaulation will be based upon: - service conditions - frequency of maintenance - know-how - requirements for extensions

Draw-Out Draw-out, an integrated part of TABULA Easy access during service Fast exchange of draw-out cassettes Service and repair can be executed with live busbars Reduces the time of stop in production Suitable for preventive maintenance

Draw-Out Major Characteristics Fully Draw-out - service, test and insulated positions Modular Main current up to 630A 30 aux. contacts 2mA to 16A Easy to combine draw-out with fixed assemblies

Draw-Out Main Current Patented, silverplated main contacts, 125A High contact pressure - ensures high lifetime of contacts Takes advantage from the electromagnetic forces - prevents welding of contacts during short circuits Easy to connect cables through the cable compartment Protected to IP2X when open/empty compartment Screening between the conductors - prevents spreading out of electrical arcs

Draw-out Main Moving Contacts The shape of the draw-out main contact ensures a high contact pressure into the C-profile. The current flow in the main contact will - due to the electromagnetic forces - open the main contact, which result in a contact pressure increase, which is proportional with the square of the current load. 1 main moving contact (In = 125 A) ; Icw = 1000 A / 22.1 sec 3 main moving contacts (In = 400 A) ; Icw = 3200 A / 10.5 sec 3 main moving contacts (In = 400 A) ; Icw = 1500 A / 25 sec

Draw-Out Pilot Current Silverplated sliding contacts (goldplated upon request) Tested against corrosion in aggressive environments More combinations possible: - Type A : Service + Test - Type B : Test - Type C : Service Direct cable connections or through terminals mounted in the cable compartment Detachable - and easy accessible

Draw-Out Important Details Door is mounted on the cassette Protected to IP2X in test position Padlock facilities in test, isolated and removed positions Cassette can be coded mechanically The open design ensures easy accessibility Draw-out and fixed assemblies can be combined in the same column

Semi - Withdrawable Economical alternative to draw-out 4 screws will be untightened and the assembly can be withdrawn IP2X by removed functional unit Exchanges of units and extensions can be carried out with live busbars

Why TABULA? Safety and functionality above all Fully typetested and documented ISO 9001 Environmental declaration A competent and international organisation is behind High level of experience A system for the complete project Optimum extension possibilities Easy to service, designed for modern principles reg. maintenance Economically attractive

TABULA The perfect choice