How To Build An Isoltech Block



Similar documents
Understanding BS EN 771-3: Aggregate concrete masonry units

Dubai Municipality Standard DMS 1: Part 5: 2004

YTONG Product list.

European Technical Approval ETA 13/0384

SIP (STRUCTURAL INSULATED PANEL)

Mold Preventing I nterior System

POLYURETHANE FOAM CONCEPT

EXPERT OPINION on the applicability of the construction technology "GRÈMOUND non-tectonic system on grounds of the documentation submitted

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Rockwool Flexi Insulation Application Guide

Concremote calibration box

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Rockwool Cladding Roll

PRODUCT GUIDE. Building the future with Ytong autoclaved aerated concrete. low tolerances high quality

European Technical Approval ETA 13/0526

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

PRODUCT GUIDE lower tolerances high quality

Unbeatable energy efficient glass curtain wall system

Development of conservation compatible new materials for envelope retrofitting of historic buildings

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

European technical approval

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

How To Make An Oriented Strand Board

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Natural Convection. Buoyancy force

LIGHT WEIGHT/LOW COST CONSTRUCTION METHODS FOR DEVELOPING COUNTRIES

1 0 0 % E C O - F R I E N D LY

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

Acoustical proprieties of light brick walls and its effects on flanking transmission

Aluminium foil properties: Applications of aluminium foils and thin gauge strips in thickness below 0,50 mm:

European technical approval

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

ProRox Slabs (formerly known as RW slabs)

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

Master Panel 1000 W Wall

temperature needed to reach the sintering necessary to make the product frost-proof, non-absorbing and resistant to chemical attacks.

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

SmartPly OSB3 SMARTPLY

How To Retaining Wall Guide

Roof Insulation Building. Energy. Environment friendly e-library

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

PROJECT PROFILE ON CEMENT CONCRETE HOLLOW BLOCKS

Light-Weight Panels. High quality panels.

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

Environmental profile of building elements details per variant. 1. Load-bearing interior wall

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Composite Panel Firewall Systems

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Mapei systems for radiating floor heating with high thermal efficiency

Squash Court Design general points

Asphalt Shingle Application Requirements

Fluid Mechanics: Static s Kinematics Dynamics Fluid

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

SIM Spartherm Installation Modules NEW

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

Multi-layer Insulation Blanket for Roofs

INSTALLATION GUIDE FOR GIROLAMI CAMINETTI OVEN

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

HEAT TRANSFER ANALYSIS OF COLD STORAGE

European Technical Assessment ETA-10/0153 of 10/06/2015

PRO. English COMPLETE PRECAST PLANT

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

SPREFIX SPRAY INSULATION _ in the marine market.

Hebel Wall Panels are custommanufactured

Annex of the certificate (Page 1/6) Accreditation Scope

SKY-TILE SKY-TILE. Daylight Consultants web: blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights

Low viscosity, solvent free elastic adhesive for wood flooring

Mineral fibreglass insulation

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

BGP index: an approach to the certification of building global performance

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling

TRITTICO ORIGINAL BY BRAVO A WHOLE WORKSHOP IN A SINGLE MACHINE

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Installation Instructions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

WOOD FLOORING ADHESIVES

Physically Crosslinked Foam Insulation

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Transcription:

isocem s/b NON AUTOCLAVED STRUCTURAL CELLULAR CONCRETE...the action of the man, in harmony with nature... isocem s/b isocem s/b IS A TECHNOLOGY DEVELOPPED AND PRODUCED BY NON-AUTOCLAVED CELLULAR CONCRETE BLOCKS: ISOCEM S/B

isocem s/b NON AUTOCLAVED STRUCTURAL CELLULAR CONCRETE THE TECHNOLOGY ISOLTECH HAS CREATED THE MOST ECO-FRIENDLY, VERSATILE AND ECONOMIC SYSTEM TO PRODUCE BLOCKS Isoltech building system in non autoclaved cellular concrete is the most complete and ecofriendly building system available nowadays. It doesn t require ovens or autoclaves, non autoclaved cellular concrete uses very few energy to be produced, and it makes a limited use of natural resources. 1. Isoltech building system can work with a total of 10,6 kw installed for 5 minutes, to produce 1 m3 of material. 2. Cellular concrete is similar to wood. As this one can be cut and nailed, even if with special nails or nogs. It has the same specific gravity of wood and it is insulator also. 3. The versatility of the production systems allows moving them easily. Thanks to their cost effectiveness and compact size, the systems needed to produce Isoltech blocks can be installed anywhere near target markets (even in the right-sized construction sites), reducing to a minimum transport costs (compared to the significant costs for all traditional materials). 4. The versatility is also in the dimension of the block: the mould developed by Isoltech permits to produce different dimensions of blocks, to be used in dividing walls and eternal. 2

Isoltech building system ENERGY SAVING STARTS IN PRODUCTION The necessary energy for the production is one the most important requirements requested to an eco-friendly material. And, below this aspect, cellular concrete has no equal. The Energy Return On Energy Investment (EnROEI), the most efficient use of Energy is the value which marks Isoltech technology from all the other alternatives. To produce building materials, it is extremely important to use as few natural resources as possible and especially to save fossil fuels. A comparison with similar products usually available on the market gives an outstanding result for Isoltech blocks and leaves no doubts about their superiority, both for the energy consumption to produce them and for the use of eco-friendly materials (cement, sand, water and protein hydrolysed). Sand Water Cement Protein hydrolysed Hollow clc blocks Bricks Autoclaved cellular concrete Isocem S/B Blocks Material 2000 kg/m3 1500 kg/m3 1000 kg/m3 500 kg/m3 0 kg/m3 Energy 1000 kwh/m3 800 kwh/m3 600 kwh/m3 400 kwh/m3 0 kwh/m3 The inert materials and the energy used to produce Isocem S/B Blocks (see tables above) are completely natural, used in moderate quantities and without any kind of fuel for autoclaves or other systems. This is because the energy for the curing is provided by the heat from the hydration of cement, properly recycled with special technical devices. 3

isocem s/b NON AUTOCLAVED STRUCTURAL CELLULAR CONCRETE THE MATERIAL NON-AUTOCLAVED CELLULAR CONCRETE ENERGY SAVING BEFORE AND AFTER THE CONSTRUCTION ISOLTECH technology is a building technology and not a specific material. Different possible materials can be used. Although previously selected and evaluated by Isoltech laboratory, the final mechanical characteristics are strongly influenced by the original raw materials. The data listed here are so conservative and indicative and can be easily improved. Isoltech, for its part, has an enviable experience, to get from raw materials provided, the best possible performance. MECHANICAL RESISTANCE Isoltech non-autoclaved cellular concrete blocks fulfill the requirements of mechanical resistance. The table below shows the already excellent mechanical strength, further improved by the Isoltech sophisticated technology, which uses where appropriate, special systems mixing and peculiar incremental additives of mechanical strength, specifically formulated. MIX DESIGN Density Cement Sand Water Isocem (kg/m3) (kg) (kg) (kg) S/B (lt) 500 250 150 95 1 570 310 150 100 0,95 600 310 210 110 0,93 700 340 290 110 0,90 800 350 370 120 0,80 900 350 470 140 0,75 Density (kg/m3) Mechanical Resistance N/mm2 500 1,3 570 1,5 600 2,0 700 2,5 800 3,0 900 3,7 Valori indicativi e non impegnativi Theoretical, approximate values Theoretical, approximate values 4

Isoltech building system EXCELLENT HEAT AND SOUND INSULATION PROVIDES BETTER COMFORT THERMAL INSULATION The Italian legislative decree of 29/12/2006, transposition of the Directive 2002/91/EC on energy performance, introduces the concept of integrated calculation of the energy performances of buildings. In particular, the following requirements must be met: 1. The calculation of the energy performance index for winter conditioning (EP) and the testing of conformance with the values reported in Annex C, point 1. 2. The transmittance values of the vertical, horizontal and tilted opaque components (all types of building) that surround the building shall not exceed by over 30% the values reported in the table mentioned in the points 2, 3, 4 of Annex C. If the radiation =>290 W/m2 on the horizontal plane (except Zone F and categories E6 and E8), the surface mass of the vertical, horizontal and tilted opaque walls must be higher than 230 kg/m2. The following table reports the energy classification in Italy, divided into 6 zones (for vertical opaque components) and the U values of blocks with different thicknesses. With a density of 600 kg/m3, Isoltech solution already exceeds the requirements of the energy consumption regulation in force from 2010. The energy certification of buildings has a section for the heat insulation class and another for the quality of energy-efficient systems. Therefore it provides the buyer with information about the energy performance and the degree of efficiency of houses and other buildings, and it increases the market value of the property. Since July 1st, 2009 every building must have a Certificate of energy efficiency and comply with the regulations for the area it belongs to. From the table below, we draw the elements to see the formidable thermal performance of cellular concrete. In addition, the high thermal inertia due to the considerable mass gives comfortable living even in structures in warm places for the favorable moving of the heat from 10 to 16 hours. Density (kg/m3) Insulation Kcal/m2/h/C 500 0,11 570 0,117 600 0,12 700 0,21 800 0,24 900 0,28 1000 0,31 1200 0,38 U values (W/m2k) of Isocem S/B blocks 2008 2010 Thickness U values A 0,72 0,62 Cm 20 0,50 B 0,54 0,48 Cm 20+5 0,35 C 0,46 0,40 Cm 30 0,34 D 0,40 0,36 Cm 30 0,34 E 0,37 0,34 Cm 30 0,34 F 0,35 0,33 Cm 30+5 0,27 Cm 40 0,26 Cm 40+5 0,22 5

isocem s/b NON AUTOCLAVED STRUCTURAL CELLULAR CONCRETE THE MATERIAL EXCELLENT HEAT AND SOUND INSULATION PROVIDES BETTER COMFORT SOUND INSULATION MICROCLIMATE AND ENVIRONMENTAL COMPATIBILITY Cellular concrete offers extraordinary sound absorption. Buildings made with blocks of cellular concrete meet legal requirements regarding sound insulation. Blocks for partitioning or infilling (40x20x20) have particular sound insulation properties. With a much higher density (800/1200 kg/m3) when heat insulation is not needed their sound insulation improves. During maintenance, cellular concrete does not release toxic substances and its environmental compatibility is second only to that of wood. As a comparison, the coefficient of environmental compatibility of cellular concrete is 2; that of wood is 1, that of bricks is 10 and that of blocks of expanded clay is 20. Cellular concrete helps to create a microclimate (like in a wooden house). The resulting energy savings create a reduction of heating and air conditioning costs of up to 30%. Density(kg/m3) Insulation db 500 40 570 43 600 45 700 47 800 49 1000 52 1200 54 6

Isoltech building system ISOCEM S/B ECO-FRIENDLY BLOCKS Blocks of Isoltech building system can be produced in the following dimensions. Length Height Width 400/500/600 200 100 400/500/600 200 150 400/500/600 200 200 These dimensions can be realized with just one mould, with variable dimensions. Perforated blocks for vertical structures with the following dimensions: Length Height Width 400/500/600 200 250 400/500/600 200 300 400/500/600 200 350 400/500/600 200 400 400/500/600 200 450 NB: More the block is bigger, more you amortize the cost of the mould. The cheapest configuration is that of a single, larger block size, such as 60x20x45. Length Height Width 400/500/600 200 250 400/500/600 200 300 400/500/600 200 350 400/500/600 200 400 400/500/600 200 450 To improve the handling of blocks, particularly bulky, we have introduced handles. Also special pieces are available: All blocks must be walled with glue with a thin thickness, made from a special adhesive ACRI 105 mixed with cement, sand and water in proper proportions. The walls have to be plastered with plaster applied with a specific sequence required by ISOLTECH. The plaster will be prepared by mixing cement, sand, water and ACRI 105. The plaster will be applied in two layers with the net ACRIVER. All walls, internal and external, partitions and infill blocks should be finished with the treatment described above. Raceway block for vaults with the following dimensions: Length Height Width 400/500/600 200 250 400/500/600 200 300 400/500/600 200 350 400/500/600 200 400 400/500/600 200 450 7

isocem s/b NON AUTOCLAVED STRUCTURAL CELLULAR CONCRETE CHOOSE ISOLTECH SYSTEM 15 REASONS TO BUILD A MORE COMFORTABLE HOUSE 1. Excellent thermal insulation 2. Excellent sound insulation 3. Extremely fast and clean placing: lower labor costs 4. Extremely easy placing and laying out of construction sites 5. Extraordinary energy savings in the production 6. Excellent combination of light weight and bearing capacity 7. Energy savings on heating and air conditioning (higher living comfort) 8. Unparalleled quality-price ratio 9. If cast on site, lower transport costs and less pollution 10. High dimensional precision 11. Joints mean saving on glues, mortar and time 12. Fire resistance 13. Optimum dry surface finish and therefore saving on plaster 14. Extremely versatile system 15. Possibility to produce a block with antiseismic features 8