Beck. The differential pressure transmitter for air



Similar documents
PRODUCT PROFILE FEATURES

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Duct Humidity Transmitter

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Pressure Switch EDS 300

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Electronic Pressure Monitoring New Products

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

T7560A,B,C Digital Wall Module

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Use A Flowmeter

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

PIEZOMETER AIRFLOW MEASURING RING

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Digital inductive conductivity transmitter

Temperature, hygrometry, CO and CO 2. probes for class 310 transmitters

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Actuator for modulating control AME 435

Pressure switches for gas and air Pressure sensors

Electronic Pressure Switch EDS 3000

Features. Picture. Specifications

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

OEM Relative and differential pressure switch type 605

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Differential Charge Amplifier

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

HD29371T - HD29V371T HD403TS - HD4V3TS HD103T.0

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Relative pressure transmitter type 520

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Instruction Manual Differential Pressure Transmitter

TENSIONMETER ** code 183_LNRSTW **

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Contents. Document information

Operating Instructions for Plastic Flow Meter. Model: KSK

HD29371T - HD29V371T HD403TS - HD4V3TS HD103T.0

Digital Pressure Measuring Instrument MDR480

W150: Miniature photoelectric switch series with completely integrated electronics

Inductive sensor NI10-M18-Y1X-H1141

Pressure Switch for gas and air

LCD Readout Digital Pressure Switch

Precision digital pressure gauge Model CPG1500

Proportional pressure regulators VPPE

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Power Supplies 3. SDN-P DIN Rail Series

GREISINGER electronic GmbH

Relative and absolute pressure switch type 529

Quick Connect. quick - simple - efficient.

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Heating, air-conditioning, cooling

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Electronic Control Devices The European Product Catalogue 2007

HVAC Sensors Catalogue

Series 6000 Torque measured metal bellow coupling

Model SRMD Setra Remote Monitoring Display

Terminal Boxes Series 8146

Incubator with mechanical convection

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Turbine Flow Sensor Series VTR

Heating oven with mechanical convection

DPI 260 SERIES: Digital Pressure Indicators

Plastic tube flowmeters Series PT/PS

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SEMICONDUCTOR TECHNICAL DATA

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Typical Aluminum GFM Mass Flow Meter

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Hand-held thermometer Model CTH7000

Short information Parameters are programmed via front-side membrane keypad

Material test chamber with mechanical convection

Portable digital microprocessor thermometers with interchangeable probes

Product Information Sheet UH28CS-12kV Hi Pot Tester

Conductive Level Switch FK 2 Technical Data:

Pressure transmitter PASCAL CV

Transcription:

Beck. The differential pressure transmitter for air

Differential pressure transmitter 98 General description The differential pressure transmitters of the 98 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch. Applications Monitoring of gaseous, non-aggressive media. Possible usage areas are: Building automation and air conditioning systems Overpressure measurement in clean rooms and laboratories Measurement of constant pressure in VAV applications Dynamic filter and ventilator monitoring Configurable pressure range For an optimum adaptation to the application, the transmitter can be switched between various pressure ranges. The factory setting is the most sensitive range. For the series 98M and 98A the less sensitive second range will be selected by simply removing a jumper. For the series 98Q the available eight ranges can be selected by a rotary selector switch. Output signal selection The output signal of the -wire version is configurable. The factory setting is for a 0...10 Volt output signal which can be changed to a... 20 ma signal by removing a jumper. The series 98M is even available in a 2-wire version with... 20 ma output signal. Volume flow measurement (optional) The shape of the output signal can be switched from linear to square root using a jumper in order to measure the volume flow via a differential pressure. Switching output (optional, not available with 2-wire version) To give a switch signal at an user defined pressure level the transmitter has an adjustable transistor switching output with a maximum switching capacity of 0 Vdc/100 ma. Display (optional, not available with 2-wire version) In addition to the analogue output signal the pressure value can be read out on a red LED-display in Pascal units. Upon request the pressure value can even be displayed in mbar or inwc units. Measuring method Piezoresistive pressure transducer Mounting position Can be mounted in any position. The self-compensating piezoresistive pressure transducer eliminates any possible mounting error. Configurable response time The response time of the output signal can be configured using a jumper. If the jumper is in place the response time is slow (factory setting), which is useful for suppressing brief pressure peaks. If the application requires a fast response time the jumper must be removed. Easy offset calibration The output signal of the 98M series can be calibrated to zero by pressing the M push-bottun in a pressureless state of the transmitter. The series 98A and 98Q perform an automated zero offset compensation. Here any drift of the zero-point is automatically corrected in regular intervals. No re-calibration is needed which reduces monitoring and maintenance efforts.

Overview on technical data NEW NEW Series 98M 98M 98A 98Q Electrical connection -wire 2-wire -wire -wire Measuring method Piezoresistive pressure transducer Supply voltage 18... 2... 0 18... 2... 0 22... 2... 0 22... 2... 0 Vac/Vdc Vdc Vac/Vdc Vac/Vdc Output signal selectable with jumper with jumper with jumper Output signal 0... 10 Volt Output signal... 20 ma Output signal 0... 5 Volt Outputsignal 0... 20 ma LED display, red, digits, units in Pascal LED display, red, digits, units in mbar LED display, red, digits, units in inwc Switching output (npn) for max 0 Vdc/100 ma Output signal selection from linear to square root max. current draw without display 60 ma 21 ma 160 ma 160 ma max. current draw with display 110 ma 210 ma 210 ma for... 20 ma output 20... 500 Ω 20... 500 Ω 20... 500 Ω 20... 500 Ω Pressure medium Air and non-aggressive gases Configuration of pressure range with jumper with jumper with jumper with Rotary Selector Switch max. number of pressure range 2 2 2 8 only one customized pressure range Manuel offset compensation Automated offset compensation Working temperature Storage temperature Linearity error Typical long-term stability Repetition accuracy Position dependence Humidity 0... +50 C -10... +70 C ± 1% of full scale ±0.5 % to ± 2.5 % of full scale/year, depending on pressure range ±0.2 % of full scale ±0.02 % of full scale/g 0... 95 % rel, non-condensing Response time, selectable with jumper with jumper with jumper with jumper Response time (0,1 s and 1 s) Response time free selectable between 0.1 s and 20 s Process connection P1 and P2 Electrical connection Mounting Housing material Hose connection with 6 mm outer diameter Screw terminal block for wires and strands up to 1.5 mm² Screw mounting with serrated screws housing with process connection P2 (-) made from ABS base part with process connection P1 (+) made from POM Housing dimensions Weight Protection class acc. to EN 60529 approx. Ø 85 x 58 mm approx. 150 gr IP5 with protection cap or IP00 without protection cap Cable conduit on protection cap M16x1,5 Cable conduit on protection cap M20x1,5 CE Conformance EN 60770, EN 6126 RoHS Conformance according to 2002/95/EEC standard equipment optional equipment

Differential pressure transmitter 98M with manual offset compensation Pressure ranges Model 98M.5X 98M.5W 98M.52 98M.5 98M.5 98M.55 98M.57 98M.59 98M.5B Range 1-50... 0... +50 Pa -100... 0... +100 Pa 0... 100 Pa 0... 1 kpa 0... 5 kpa 0... 25 kpa 0... 100 kpa Range 2 0... 1.000 Pa 0... 2.5 kpa 0... 10 kpa 0... 50 kpa 0... 250 kpa Overload capacity 60 kpa 00 kpa 1.2 MPa Bursting pressure 70 kpa 1 500 kpa 2 MPa Temperature error ±.5 % of full scale Order matrix IP protection class IP 5 with cable conduit M16x1.5 98M. 5 IP 5 with cable conduit M20x1.5 Configurable -50... 0... +50 Pa (-0,5... 0... +0,5 mbar) X pressure range -100... 0... +100 Pa (-1.0... 0... +1,0 mbar) W 0... 100 Pa (1.0 mbar) (2.5 mbar) 2 (2.5 mbar) (5.0 mbar) (5.0 mbar) 0... 1.000 Pa (10 mbar) 0... 1 kpa (10 mbar) 0... 2.5 kpa (25 mbar) 5 0... 5 kpa (50 mbar) 0... 10 kpa (100 mbar) 7 0... 25 kpa (250 mbar) 0... 50 kpa (500 mbar) 9 0... 100 kpa (1.000 mbar) 0... 250 kpa (2.500 mbar) B Pressure unit Pascal mbar 1 Output signal and 0...10 V or... 20 ma, -wire, 2 Vac/Vdc, with switching output 1 supply voltage 0...10 V or... 20 ma, -wire, 2 Vac/Vdc, without switching output 7... 20 ma, 2-wire, 2 Vdc, with switching output 2... 20 ma or 0... 10 V, -wire, 2 Vac/Vdc, with switching output... 20 ma or 0...10 V, -wire, 2 Vac/Vdc, without switching output D Display no display 0 with LED-display, digits (not for 2-wire) 1 Electrical connection via screw terminal block Factory settings printed in bold type. Terminal assignments -wire version 2-wire version 0 10 V 2...20 ma 18 2 0 Vac 16 2 2 Vdc 1 20 ma 2 15...2...0 Vdc 1 SA Switching output, npn GO Ground GND 2 Y Output signal 0 10 V /... 20 ma 1 G Supply voltage 2 VAC/ VDC 2 Y Output signal 20 ma 1 G Supply voltage 2 VDC

Differential pressure transmitter 98A with automated offset compensation NEW Pressure ranges Model 98A.5E 98A.5X 98A.5W 98A.50 98A.51 98A.52 98A.5 98A.5 98A.55 98A.57 98A.59 98A.5B Range 1-25... 0... +25 Pa -50... 0... +50 Pa -100... 0... +100 Pa 0... 25 Pa 0... 50 Pa 0... 100 Pa 0... 1 kpa 0... 5 kpa 0... 25 kpa 0... 100 kpa Range 2 0... 50 Pa 0... 100 Pa 0... 1.000 Pa 0... 2.5 kpa 0... 10 kpa 0... 50 kpa 0... 250 kpa Overload capacity 60 kpa 00 kpa 1.2 MPa Bursting pressure 70 kpa 1 500 kpa 2 MPa Temperature error ± 2.5 % of full scale ± 2.5 % of full scale ± 1.5 % of full scale Order matrix IP protection class IP 5 with cable conduit M16x1.5 98A. 5 IP 5 with cable conduit M20x1.5 Configurable -25... 0... +25 Pa (-0.25... 0... +0.25 mbar) E pressure range -50... 0... +50 Pa (-0.5... 0... +0.5 mbar) X -100... 0... +100 Pa (-1.0... 0... +1.0 mbar) W 0... 25 Pa (0.25 mbar) 0... 50 Pa (0.5 mbar) 0 0... 50 Pa (0.5 mbar) 0... 100 Pa (1.0 mbar) 1 0... 100 Pa (1.0 mbar) (2.5 mbar) 2 (2.5 mbar) (5.0 mbar) (5.0 mbar) 0... 1.000 Pa (10 mbar) 0... 1 kpa (10 mbar) 0... 2.5 kpa (25 mbar) 5 0... 5 kpa (50 mbar) 0... 10 kpa (100 mbar) 7 0... 25 kpa (250 mbar) 0... 50 kpa (500 mbar) 9 0... 100 kpa (1.000 mbar) 0... 250 kpa (2.500 mbar) B Pressure unit Pascal mbar 1 Output signal and 0...10 V or... 20 ma, -wire, 2 Vac/Vdc, without switching output 7 supply voltage... 20 ma or 0...10 V, -wire, 2 Vac/Vdc, without switching output D Display no display 0 with LED-display, digits 1 Electrical connection via screw terminal block Factory settings printed in bold type. Terminal assignments -wire version 0 10 V 2...20 ma 18 2 0 Vac 16 2 2 Vdc 1 SA Switching output, npn GO Ground GND 2 Y Output signal 0 10 V /... 20 ma 1 G Supply voltage 2 VAC/ VDC

Differential pressure transmitter 98Q with 8 pressure ranges NEW Pressure ranges Model 98Q.5 Range 1 1 2 5 6 7 8 Pressure range -50... 0... +50 Pa -100... 0... +100 Pa -250... 0... +250 Pa -500... 0... +500 Pa 0... 100 Pa 0... 1000 Pa Overload capacity Bursting pressure Temperature error ± 2.5 % of full scale ± 2.5 % of full scale ± 1.5 % of full scale Order matrix IP protection class IP 5 with cable conduit M16x1.5 98Q. 5 IP 5 with cable conduit M20x1.5 Configurable -50... 0... +50 Pa (-0.5... 0... +0.5 mbar) pressure ranges -100... 0... +100 Pa (-1.0... 0... +1.0 mbar) -250... 0... +250 Pa (-2.5... 0... +2.5 mbar) -500... 0... +500 Pa (-5.0... 0... +5.0 mbar) 0... 100 Pa (1.0 mbar) (2.5 mbar) (5.0 mbar) 0... 1000 Pa (10 mbar) Pressure unit Pascal mbar 1 Output signal and 0...10 V or... 20 ma, linear, 2 Vac/Vdc, without switching output 7 supply voltage 0...10 V or... 20 ma, linear, 2 Vac/Vdc, with switching output 1 0...10 V or... 20 ma, lin/rad, 2 Vac/Vdc, without switching output L 0...10 V or... 20 ma, lin/rad, 2 Vac/Vdc, with switching output K Display no display 0 with LED-display, digits 1 Electrical connection via screw terminal block Factory settings printed in bold type. Terminal assignments -wire version 0 10 V 2...20 ma 18 2 0 Vac 16 2 2 Vdc 1 SA Switching output, npn GO Ground GND 2 Y Output signal 0 10 V /... 20 ma 1 G Supply voltage 2 VAC/ VDC

Dimensional Drawings 98 with cable conduit M16x1.5 98 with cable conduit M20 x1.5 ø6 65 50 65 50 Mounting bracket 601 Mounting bracket 602 Duct connection for Climaset 6550/6556 ø 0 ø 50 ø 50 ø 55 50 100 ø 6 60 10 21.5 ø 16 ø.5 ø10 18 11 70.5 65.5 7.7 0 60 ø 5 10 0 Mounting bracket 681 Mounting bracket 682 2 Duct connection for Climaset 6555/6557 ø6 ø 5 0 60 7 2 71 19.5 10 ø 5 ø6 57.5 57.5 21.8 7.5 18 21.8 7.5 18 59 59 90.5 8.5 ø.5 65.5 8.5 ø.5 18.5 80 ø. ø16 ø25 6 0 60 10 ø 6.5 60 19 682

Accessories Metal mounting bracket S-shaped Article No. 602 Metal mounting bracket L-shaped Article No. 601 Snap-on plastic bracket S-shaped Article No. 682 Snap-on plastic bracket L-spaped Article No. 681 Climaset consisting of 2m PVC hose and 2 plastic pipes with 65 mm length Article No. 6555 Climaset consisting of 2m PVC hose and 2 plastic pipes with 80 mm length Article No. 6555-80 Climaset consisting of 2 m Silicone hose and 2 plastic pipes Article No. 6557 Climaset consisting of 2 m PVC hose and 2 angled metal pipes Article No. 6550 Climaset consisting of 2 m Silicone hose and 2 angled metal pipes Article No. 6556 Duct connecting pipe for Climaset 6555, with 65 mm length Article No. 6551 Duct connecting pipe for Climaset 6555-80, with 80 mm length Article No. 6551-80 Angled metal pipe for Climaset 6550 Article No. 6552 Rubber grommet for Climaset 6550 Article No. 655 Roll with 100 m PVC hose Article No. 62 Roll with 100 m Silicone hose Article No. 625 M16x1.5 cable conduit including seal and gland nut Article No. 6562 M20x1.5 cable conduit including seal and counter screw Article No. 6568 1/2 NPT cable conduit without insert Article No. 6561 Folding box for individual packing (with accessories) Article No. 628 Folding box for individual packing (with accessories) Article No. 629 We exhibit 98Q_data_english 02/201 Technical data subject to change without prior notice. Copyright 201 Beck GmbH 12. 0. - 16. 0. 201 Frankfurt, Germany hall 10.1, stand B29 08. 0. - 12. 0. 201 Hannover, Germany hall 11, stand C1/1 07. 10. - 10. 10. 201 Stuttgart, Germany hall 5, stand 501 18. 0. - 21. 0. 201 Milan, Italy hall 15, stand D2 Beck GmbH Druckkontrolltechnik P.O. Box 11 1 D-7110 Steinenbronn Telephone +9 (71 57) 52 87-0 Telefax +9 (71 57) 52 87-8 e-mail sales@beck-sensors.com http://www.beck-sensors.com