CEA LIST activity on Cable Monitoring and Diagnosis



Similar documents
Utilisation de la réflectométrie pour fiabiliser les câbles d un système

On-Line Diagnosis using Orthogonal Multi-Tone Time Domain Reflectometry in a Lossy Cable

PHY3128 / PHYM203 (Electronics / Instrumentation) Transmission Lines. Repeated n times I L

Coherent sub-thz transmission systems in Silicon technologies: design challenges for frequency synthesis

A wave lab inside a coaxial cable

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Hardware Acceleration for Just-In-Time Compilation on Heterogeneous Embedded Systems

Cable Analysis and Fault Detection using the Bode 100

EECC694 - Shaaban. Transmission Channel

Distributed Temperature Sensing - DTS

Secure data processing: Blind Hypervision

TIMING SIGNALS, IRIG-B AND PULSES

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Transmission Lines in Communication Systems FACET

Advanced Systems Tester 900AST

SVPRIBOR ALFA DSL. Users Manual

Oscar E. Morel UtilX Corporation

75 Ω Transmission System

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

AMP CO Plus Insert for Cat. 6 A Applications

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

LocoNet, the Digitrax Difference

Fabrice Auzanneau * CEA, LIST, CEA Saclay Nano-INNOV, PC 172, F Gif sur Yvette, France

DRAFT. University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

Network Design. Yiannos Mylonas

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

N4385A / N4386A Distributed Temperature System (DTS)

Communication, Signal & Data Cables

Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique :

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Grounding Demystified

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of

Radiated Emission and Susceptibility

Module 13 : Measurements on Fiber Optic Systems

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Wireless Power Transfer System Design. Julius Saitz ANSYS

RX-AM4SF Receiver. Pin-out. Connections

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Current Probes. User Manual

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

2. THE TEORRETICAL OF GROUND PENETRATING RADAR:

Current Probes, More Useful Than You Think

DTS / PDMS / Portable.

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

EMC / EMI issues for DSM: new challenges

Robot Perception Continued

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Broadband 101: Installation and Testing

MOHR Application Note: TDR vs. FDR: Distance-to-Fault

Cable Impedance and Structural Return Loss Measurement Methodologies

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

IC-EMC v2 Application Note. A model of the Bulk Current Injection Probe

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

DSL LINE TESTER USING WIDEBAND FREQUENCY DOMAIN REFLECTOMETRY

NEW MICROWAVE APPLICATIONS FOR THICK FILM THERMISTORS

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Condition Based Monitoring of Gas Turbine Combustion Components Program Review

spinner Measurement & Calibration equipment for network analyzers

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

Terminal and Dimension

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

SHEET 5 CABLE TELEVISION SYSTEM

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

CCTV System Troubleshooting Guide

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Coaxial Cables for Medium-Frequency Applications

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

Antenna Properties and their impact on Wireless System Performance. Dr. Steven R. Best. Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013

Agilent 8753ET/8753ES Network Analyzers

Redundancy Module QUINT-DIODE/40

6 ELECTRICAL PARAMETERS

Understanding the Electrical Performance of Category Cables

: Instructor

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Fault location on power cables. Fault location on power cables

Cable Solutions for Servo and Variable Frequency Drives (VFD)

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

Technical Description U00980 Revision 2

Preview of Period 3: Electromagnetic Waves Radiant Energy II

)454 6 %LECTRICAL CHARACTERISTICS FOR BALANCED DOUBLECURRENT INTERCHANGE CIRCUITS OPERATING AT DATA SIGNALLING RATES UP TO -BITS

NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Transcription:

CEA LIST activity on Cable Monitoring and Diagnosis Contact : Mr Josy COHEN Responsable de projet ingénieur chercheur Josy.cohen@cea.fr +33 1 69 08 78 07 www.cea.fr

Cliquez CEA pour experience modifier in cable style diagnosis du titre Our Laboratory : LFIC : Laboratoire Fiabilité et Capteurs Intégrés More than 10 years experience and knowledge in network cable diagnosis CEA policy : To create breakthrought to take advantage and to create new jobs by industrial transfer for French companies CEA. All rights reserved DACLE Division 2

Cliquez pour modifier Ubiquitous le style du cable titre CEA. All rights reserved DACLE Division 3

Cliquez pour Reflectometry modifier style : Principle du titre The reflectometry principle is related to the signal propagation mechanism into a transmission line (TL) S dx ZL Parallel Torsade Coaxial Modeling and characterization of a TL R, L, C, G Model based on Telegrapher's equations to figure out how a signal is propagated into a TL we have to look signal distortion phenomenon i (x) R dx L dx i ( x dx ) v(x) G dx C dx x Telegrapher's equations 2 v( x, t) LC 2 x 2 v ( x dx) x dx v( x, t) v( x, t) ( LG RC) RG v( x, t) 2 t t Attenuation and dispersion Z c R jl G jc 1 V g LC Reflectometry : measurement of transmission line characteristic impedance variation CEA. All rights reserved DACLE Division 4

Cliquez pour modifier CEA le Breakthrought style du titre Some new technologies developed CEA. All rights reserved DACLE Division 5

Cliquez pour modifier On le line style Diagnosis du titre MCTDR (Multicarrier Time Domain Reflectometry) Probe signal corresponds to a sum of sine curves The probe signal spectrum is controllable by cancelling the desired carried signal Safe diagnosis : Harmless ness EMC Compliance Low sensitivity to SNR MCTDR in TRL > 5 CEA. All rights reserved DACLE Division 6

Cliquez pour modifier le Long style distance du titre Adaptive correlation for performance enhancement : Sensitivity Railway signalization cable, reel length : 2km Measure Standard correlation Adaptive correlation Amplitude (V) 0.1 0.18 0.59 Localization (m) 2260 2257 2073 Relative error 13% 13 % 3.7 % CEA. All rights reserved DACLE Division 7

Cliquez pour modifier Complex style network du titre Distributed-MCTDR V1 S1 S2 V2 S3 V3 The reflectometry distribution is obtained with a weighted mean process allowing a cross-correlation between reflectometers. Multi-sensing strategy allowing to avoid the ambiguity. A specific tool is proposed to facilitate the reflectometer deployment and to simulate the diagnosis strategy CEA. All rights reserved DACLE Division 8

Cliquez pour modifier Technology le style integration du titre Avionic DIAGNOCHIP, a 3 mm2 130nm integrated reflectometer A mixed Analog/Digital IP for real time processing 5cm resolution (4GHz guided wavelength) Railway Solar power CEA. All rights reserved DACLE Division 9

Cliquez CEA pour breakthougth modifier le style Valorisation du titre Implemantation of CEA policy hard fault diagnosis: Licence sales Transfert project for academic laboratory Bilateral industrial project : For specific research For technological or know how transfert Spin off : Start up creation Win MS But also Collaborative research project with different partners CEA. All rights reserved DACLE Division 10

Contact: contact.dacle@cea.fr http://www.win-ms.com

Cliquez pour modifier CEA le Breakthrought style du titre Some new technologies in progress CEA. All rights reserved DACLE Division 12

Amplitude [V] Amplitude [V] Cliquez pour Reflectometry modifier le for style soft du defect titre Injection Plan Localized defect Zd Cable end Zc: characteristic impedance S Probe signal Reflected signal Transmitted signal T 0.5 0.4 0.3 0.2 0.1 2 D Parallel defect Reflected wave by the cable end Short Court-circuit 25 Ohms 50 Ohms 75 Ohms 100 Ohms 125 Ohms Circuit Open circuit ouvert 0.45 0.4 0.35 0.3 0.25 Reflected by the defect Serial defect Reflected wave by the cable end Short Court-circuit 25 Ohms 50 Ohms 75 Ohms 100 Ohms 125 Ohms Circuit Open circuit ouvert 0-0.1-0.2 2 L 0.2 0.15 0.1-0.3 Reflected by the defect -0.4 0 0.5 1 Temps [s] 1.5 2 x 10-7 0.05 0 0 0.5 1 1.5 2 Temps [s] x 10-7 CEA. All rights reserved DACLE Division 13

External source of failure Mechanical stress Assembly errors Cliquez pour Reflectometry modifier le for style soft du defect titre Corrosion, oxidation Effect of environment s Internal source of failure Manufacturing errors Wear-out defect Local hot-spot Wear type Primary signs Detection method Overheating of the wire Bad contact Intermittent short circuit faults Wear zone Change in impedance Local hot spot Electromagnetic Magnetic Interference Electric arc Visual inspection Reflectometry Thermal, Point by point test Reflectometry Visual inspection Reflectometry Short circuit faults Circuit-breaker system Reflectometry Broken insulation Exposed conductor Corrosion Crack, damaged area Loss of the function Fire Loss of signal or data Visual inspection Reflectometry Visual inspection Reflectometry Visual inspection Reflectrometry Humidity Loss of signal or data Reflectometry Wear out and/or Loss of the function Local alteration of R, L, C, G parameters Local alteration of the characteristic impedance Zc Local alteration of the propagation speed ΓL 0 Open defect Soft defect CEA. All rights reserved DACLE Division 14

Amplitude Amplitude Amplitude Amplitude Cliquez Soft pour defect modifier detection le style (chafing) du titre One of our advance post processing for soft defect signature amplification 1 0.8 Simulation reflectogramme initial reflectogramme traité 1 0.8 Experimentation reflectogramme initial reflectogramme traité 0.6 0.4 Soft defect 0.6 0.4 Soft defect Cab_224b Twisted pair (5 m) - Shielded - AWG24 0.25mm² Soft defect = sheath + shield (pulled out) 2cm 0.2 0.2 0 0-0.2-0.2-0.4 0 1 2 3 4 5 6 Distance(m) -0.4 0 1 2 3 4 5 6 Distance(m) 1.2 1 0.8 0.6 Open wire End of cable reflectogramme initial reflectogramme traité 1 0.8 0.6 0.4 0.2 Adapted wire End of cable reflectogramme initial reflectogramme traité Coaxial cable RG58CU (3.20 mètres) Soft defect = sheath + shield (pull out) 2cm 0 0.4 0.2 Soft defect -0.2-0.4 Soft defect -0.6 0-0.8-0.2 0 0.5 1 1.5 2 2.5 3 3.5 Distance(m) -1 0 0.5 1 1.5 2 2.5 3 3.5 Distance(m) CEA. All rights reserved DACLE Division 15

Cliquez pour Prognostic modifier diagnosis le style du (aging) titre Aging monitoring based on time reversal reflectometry Symetric L= 500m Sain New TR + Processing Open circuit Age Open circuit Aging effect Simulations C 0 x 1.2 C 0 C 0 x 0.8 C 0 x 0.6 C 0 x 0.4 C 0 x 0.2 Asymmetry Coefficient 1.09 1 0.9045 0.7934 0.6683 0.5127 CEA. All rights reserved DACLE Division 16

Cliquez Cable pour and modifier aging characterization le style du titre Cable characterization by RLCG parameters extraction Coaxial (5 m) Zc = 75 Ω V² = 3,7 Likelihood ratio Aging characterization New Coaxial (9,8 m) Zc = 75 Ω Aged CEA. All rights reserved DACLE Division 17

Cliquez Interconnection pour modifier characterization le style du titre Signal injection Cable under test Signal injection Cable connection and junction characterization 30cm 50Ω 87Ω Zc = 75 Ω Coaxial V² = 4,65 Likelihood ratio 0,1% real part 1-2% imaginary part ld = 30 cm To characterize interconnection or connector (database) To diagnosis soft defect in the interconnection CEA. All rights reserved DACLE Division 18

Cliquez pour modifier Beyond le reflectometry style du titre CEA. All rights reserved DACLE Division 19

Cliquez pour modifier Aera le style of expertise du titre More than 25 patents And 60 publications CEA. All rights reserved DACLE Division 20

Cliquez pour modifier CEA le Breakthrought style du titre All these new technologies and know how in LFIC What are the new technologies for the future? Which new application domain? Use a cable like environement sensor (temperature, humidity, ) New application domain : SHM for Composite CEA ready to collaborate with industrials to work in partnership CEA. All rights reserved DACLE Division 21

Merci pour votre attention Centre de Grenoble 17 rue des Martyrs 38054 Grenoble Cedex Centre de Saclay Nano-Innov PC 172 91191 Gif sur Yvette Cedex