HEPA Filtration. HEPA Series Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT



Similar documents
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Residential Duct Systems for New and Retrofit Homes

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

READ AND SAVE THESE INSTRUCTIONS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

How To Install A Perfect 16 Id Series Filter System

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

DBF 4XL Dryer Booster Fans

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

SL280UHV SERIES GAS FURNACE WARNING

Cooktop Low-Profile Ventilation Hoods

HEAT WAVE DUCT KIT KIT #

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Building Performance Solutions HVAC Design Guide, 2007

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

Operation and Installation Manual. Max Series

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

Ceiling Mount Air Handler Manual

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

B-AIR BLOWER CUB POWER MODEL # CP-1

Ventilation Solutions Kitchens. fantech

HVAC Design Requirements

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

Commercial Gas Furnace Upflow

Contract for Weatherization Management Address City & State

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

THREE. Heating and Cooling

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

INSTALLER S & OWNER S MANUAL

Residential Ventilation

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Installation Instructions ERV/PRV Downdraft Vent

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Home Management Checklist: Spring

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

WHOLE-HOUSE VENTILATION SYSTEMS

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Glossary of HVAC Terms

Gas-Fired, Residential Storage Type Water Heaters

USER S INFORMATION MANUAL

POWER GEAR SLIDE OUT MANUAL

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

How to Measure HVAC System Airflow

EACO DOP / PAO TESTING GUIDELINE 2013

Heating, Ventilation and Air-Conditioning (HVAC)

Your Guide to Buying an Energy-Efficient Central Air Conditioner

Basics of HVAC Cleaning

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Diagnostics for Mobile Homes: HVAC

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Installation Instructions

Installation Instructions

How To Warranty A Car From Nordyne

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers

Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model

Evaluate, Clean, and Tune Guidance

Copyright Puradigm, LLC HVAC Owner s Manual

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Air Conditioning System

Quest 105, Dry155, and 205 Dual

Minneapolis Duct Blaster

Guide Specification SECTION COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

Cooling Capacity CFM in. w.c. (125 Pa)

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

air conditioners how to choose a cooling system

TECHNICAL MANUAL GDS8 & GHS8

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

MAINTENANCE AND PERFORMANCE CHECKLIST

Use and Care. Central Air Conditioning (EN)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

WS-69TB30SS (22") WS-69TB36SS (22") WS-69TS30SS (18") WS-69TS36SS (18")

Element D Services Heating, Ventilating, and Air Conditioning

Before You Start an Energy Efficiency Retrofit The Building Envelope

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

1 For All Non-Programmable Digital Thermostat

Residential Standby Extended Warranty Statements

Transcription:

HEPA Series Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler, operating at a higher static pressure. Your Fantech HEPA Filtration system should be installed in conformance with the appropriate local, provincial or state requirements or in the absence of such requirements with the current edition of the National Building Code, and / or ASHRAE s Good Engineering Practices. HEPA Filtration CM 3000 CM 3000 I INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TABLE OF CONTENTS WARRANTY / GARANTIE INSTALLATION Types of installation Installation of CM 3000......4 Installation of CM 3000 I...... 6 Installation with an HRV/ERV...... 8 MAINTENANCE...... 9 MAINTENANCE REPORT...10 The Best Limited Warranty in the Business The maintenance free motors are permanently lubricated and are guaranteed for 7 years. They are factory balanced to prevent vibrations and promote silent operation. All other components have a 5 year limited warranty. (filters not included) The limited warranty covers normal use. It does not apply to any defects, malfunctions or failures as a result of improper installation, abuse, mishandling or misapplication, fortuitous occurrence or any other circumstances outside manufacturer's control. The warranty is in effect for 5 years on parts and 7 years on the motor after the date of purchase, including parts replaced during this time period. If there is no proof of purchase available, the date associated with the serial number will be used for the beginning of the warranty period. Parts are a 1 year warranty when replaced after the initial warranty has expired. This warranty is the exclusive and only warranty in effect and all other warranties either expressed or implied are invalid. Warranty from the manufacturer is for parts only and does not include labor or shipping to service or repair them. INTRODUCTION HEPA AIR FILTRATION SYSTEMS Congratulations! You have purchased a very effective air cleaning and treatment system incorporating HEPA (High Efficiency Particulate Arrestance) filter technology. This is the type of air cleaning equipment that respiratory specialists recommend most. To optimize the performance of your HEPA Filtration System, it should be installed by a professional contractor who is familiar with your indoor air quality situation and the operation of other heating, ventilation and air conditioning equipment that you may have. TWO UNITS TO CHOOSE FROM The Fantech HEPA Filtration system is available in two different models, depending on your choice of installation. Typically the CM 3000 is used in geographical locations where the HEPA unit can be installed in a conditioned space such as a basement, closet or heated crawl space, (Example on page 4 & 5). The CM 3000 I (Insulated version) is normally installed in the southern U.S. states where it's common to locate the HVAC equipment in an unconditioned space such as a garage or attic (Example on pages 6 & 7).

INTRODUCTION SPECIFICATION Model CM 3000 (Uninsulated) * Insulated skin can be purchase seperately and installed in the field if required. Kit (Included): - two pcs. of uninsulated 8 flex (UL Listed) - four 8 round port collars - hanging chains and hardware - installation manual Clearance required for servicing Volts: 115V/1/60 Amps: 1Amps Delivers 240 cfm Airflow SPECIFICATION Model CM 3000 I (Insulated) Unit includes: - two 8 round port collars (attached) - hanging chains and hardware - installation manual Clearance required for servicing Volts: 115V/1/60 Amps: 1Amps Delivers 240 cfm Airflow

OPERATION Your Fantech HEPA filtration system incorporates three stages of filtration. Air is drawn from the house via one of the installation examples, found in this manual, by a powerful efficient EBM fan. The air is cleaned as it passes through the filters, where it is then reintroduced back into the home, cleaned of the majority of harmful particles. Note: A semi-annual service schedule must be followed to ensure the HEPA unit is operating at its full potential. INSTALLATION CM 3000 - Uninsulated model The return side of the furnace is the recommended location for the HEPA to connect to. The supply side is normally avoided due to the higher static pressure. Option A * Furnace fan should operate continuous or when HEPA unit is on and running. (Options A & B) Option B * Diagrams are examples only. Actual installation may vary. 4

INSTALLATION CM 3000 - Uninsulated model (continued) Option C - Duct work can be concealed in walls or closets. If the floor is the only choice, special care should be taken to avoid noise or drafts. Option C Option D - Unit can be installed in a closet. Air drawn from a hallway or living area is cleaned by the HEPA unit and reintroduced back into a bedroom or other room. * Diagrams are examples only. Actual installation may vary. Option D 5

INSTALLATION CM 3000 I - Insulated model In options A & B, the air handler should operate continuously or when HEPA unit is on and operating. Warning - Special care and attention must be given to ensure that all openings in unit, and its duct connections, are sealed, to prevent vehicle exhaust from entering the unit. Always follow local and state building codes as well as good engineering practices. Option A - Garage installation Option B - Attic installation connected to return of air handler * Diagrams are examples only. Actual installation may vary. 6

INSTALLATION CM 3000 I - Insulated model (continued) When unit is installed in an unconditioned space such as option C or option D, ductwork (not included) must be insulated and installed according to local and state codes. Unit should always be installed in a location that will allow the best possible access for service. Flexible ducting can be restrictive to airflow and should be kept to a minimum. Avoid excessive turns, cramped ductwork and pinching. * Proper airflow should be confirmed after installation Option C - Independently ducted 30 max recommended Note: 16.5" of clearance is needed from front of unit to access filter for service. Option D - Independently ducted installation in crawl space Unconditioned crawl space * Diagrams are examples only. Actual installation may vary. 7

INSTALLATION Whole House - Connecting a ventilation system (HRV/ERV) to a HEPA system. Installation may vary drastically from picture depending on location of all appliances. After installation, proper operation of all the appliances must be confirmed by a qualified contractor. Fresh air from outside Ventilation system (HRV/ERV) should be installed and balanced in accordance with its installation manual. Furnace fan must be on when either the ventilation system (HRV/ERV) or the HEPA filtration system is operating. A power damper is recommended to prevent backdrafting of some models of air to air changers, when in the off or standby position. This damper will be installed between the HRV/ERV and the HEPA unit. NOTE: Models SHR/SER 1505R, 2005R & 3005R have an automatic backdraft damper build in that activates when units are in standby position and do not need this additional damper. All units should be checked after installation for compatibility and proper operation. Controls Options A "Accessory Control Contacts" device, which switches the HEPA to its on position anytime the furnace blower is operating, is available through Fantech distributors. * Diagrams are examples only. Actual installation may vary. 8

SERVICE The useful service life of the filter media in the HEPA Filtration System is directly related to the volume of air passed through the system and the amount of contaminants in the air. In a typical residential application, Stage 1 and 2, filters should be replaced every three to six months or when needed. The Stage 3 HEPA filter should have a life span of two to five years, again, depending on the amount of particulate in the air and the maintenance of the Stage 1 pre-filter. PARTS LIST STAGE 1 - PRE-FILTER (470142) STAGE 2 - CARBON FILTER (104654) STAGE 3 - HEPA FILTER (470140) MOTOR - (500002) Stage 1 - Prefilter: Air passes through the prefilter where larger particles are taken out of the air. Stage 2 - Carbon: Air passes through the carbon filter where some gases and odors are removed. Stage 3 - HEPA: Air passes through the certified HEPA media where very small particles are removed. 99.97% of all particles 0.3 microns and larger that pass through this stage are removed. Particles smaller than 0.3 microns are also removed with less intensity. If the air flow through your unit is noticeably reduced, you can inspect the HEPA filter by removing it and seeing if the filter paper is darkened on the inlet or outer side. If it is, the filter cartridge should be replaced. Please contact your local Fantech dealer or call HEPA Customer Service at 1.800.747.1762 regarding replacement of filter media, warranty information or if you have any questions or concerns about the performance of your HEPA Filtration System. 9

MAINTENANCE Schedule Date Type of Service Performed Service Technician 10

11 NOTES

United States 1712 Northgate Blvd., Sarasota, FL. 34234 Phone: 800.747.1762; 941.309.6000 Fax: 800.487.9915; 941.309.6099 www.fantech.net; info@fantech.net Canada 50 Kanalflakt Way, Bouctouche, NB E4S 3M5 Phone: 800.565.3548; 506.743.9500 Fax: 877.747.8116; 506.743.9600 www.fantech.ca; info@fantech.ca Fantech, reserves the right to modify, at any time and without notice, any or all of its products features, designs, components and specifications to maintain their technological leadership position. Article #: 301020 Item #: 401482 Rev Date: 111504