Electronic timer CT-TGD.12



Similar documents
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Analog signal converters CC-E I/I Current / current isolators

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 Series - Relay interface modules A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

RM4TG20 three-phase network control relay RM4-T - range V

Pluggable interface relays CR-P Pcb relays

EMR measuring and monitoring relays

Thermistor motor protection

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

80 Series - Modular timers 16 A. Features

Type: DILM9 10(24VDC) Article No.:

Manual motor starter MS116

48 SERIES Relay interface modules 10 A

Relés e Contatores de Estado Sólido SIRIUS

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

49 Series - Relay interface modules A. Features

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MasterINTERFACE 39 Series - Relay interface modules

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Redundancy Module QUINT-DIODE/40

Technicaldata General

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Catalog. Modular DIN rail components Installation contactors

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

ABB i-bus KNX SA/S Switch Actuators Product Manual

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Three-phase monitoring relays Product group picture

40 Series - Miniature PCB/Plug-in relays A. Features

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Preset Counter signo 721

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Telephone- and leased line modem for industrial applications TD-36

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supplies 3. SDN-P DIN Rail Series

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

STRATO LED Drivers 70W, Single output

Digital input modules

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

15 Series - Electronic step relay and dimmer. Features SERIE

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

PHOENIX CONTACT - 01/2007

Signal converters Index

E-STOP relays, safety gate monitors

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Thermal-Magnetic Circuit Breaker M1-..

E-STOP relays, safety gate monitors

Bimetallic Overload Relay Specifications

PNOZsigma - Base units

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Voltage Regulator SPAU 341 C. Product Guide

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Cross-beam scanning system to detect slim objects. 100 mm in

Contact expansion modules

Waveguide Access Point WGA631. Product Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

E-STOP relays, safety gate monitors

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Transcription:

2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection of the time range of the OFF time d Potentiometer with direct reading scale for the fine adjustment of the OFF time e U: green LED V control supply voltage applied W timing f R: yellow LED V output relay energized g Function diagram Features Rated control supply voltage 24 48 V DC, 24 240 V AC Single function timer pulse generator 2 x 7 time ranges (0.05 s 100 h) in one device 1 c/o contact (250 V / 6 A) Control input: voltage related triggering, polarized, capable of switching a parallel load 2 LEDs for status indication Width of only 17.5 mm Light grey enclosure in RAL 7035 Approvals A D K E Marks a b UL 508, CAN/CSA C22.2 No.14 GOST CB scheme CCC CE C Tick Order data Type CT-TGD.12 Rated control supply voltage 24 48 V DC, 24 240 V AC Time range Output Control input 2 x 0.05 s 100 h 1 c/o contact voltagerelated triggering Order code Application With their structural form and their width of 17.5 mm only, the CT D range timers are ideally suited for installation in distribution cabinets. Operating mode The CT TGD.12 has 1 c/o contact and provides 2 independent timing circuits, one for adjustment of the ON time and one for adjustment of the OFF time. Two rotary switches, on the front of the unit, allow selection of one of 7 time ranges from 0.05 s to 100 h for each time delay. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit.

Function diagram(s) DE Pulse generator, starting with ON or OFF This function requires continuous control supply voltage for timing. Applying control supply voltage, with open control input A1 Y1/B1, starts timing with an ON time first. Applying control supply voltage, with closed control input A1 Y1/B1, starts timing with an OFF time first. The ON & OFF times are displayed by the flashing green LED, which flashes twice as fast during the OFF time. The ON & OFF times are independently adjustable. If control supply voltage is interrupted, the output relay de energizes and the time delay is reset. A1-A2 A1-Y1/B1 15-18 15-16 green LED t1 t2 t2 t1 2CDC 252 040 F0207 t1 = adjusted OFF time t 2 = adjusted ON time Connection diagram(s) A1 15 Y1/B1 Y1/ B1 A1 15 A2 16 18 18 16 A2 2CDC 252 119 F0b06 15 16/18 1. c/o contact A1 A2 Rated control supply voltage U S 24 48 V DC or 24 240 V AC A1 Y1/B1 Control input Wiring instructions Parallel load to control input possible / allowed L(+) A1 Y1/B1 2CDC 252 102 F0b06 A2 N(-) 2

Technical data Data at T a = 25 C and rated values, if nothing else indicated Input circuits - Supply circuit Rated control supply voltage U S A1 A2 24 240 V AC A1 A2 24 48 V DC Rated control supply voltage tolerance 24 240 V AC 15...+10 % 24 48 V DC 15...+10 % Typical current / power consumption 24 V DC 230 V AC 115 V AC 24 48 V DC 13.21 ma / / / 24 240 V AC / 58.53 ma / 46.81 ma / Rated frequency Frequency range AC Power failure buffering time DC; 50/60 Hz 47 63 Hz min. 20 ms Input circuits - Control circuit Control input, control function A1 Y1/B1 start timing external Kind of triggering voltage related triggering Resistance to reverse polarity Polarized Capable of switching a parallel load Maximum cable length to the control inputs Minimum control pulse length Control voltage potential yes yes yes 50 m 100 pf/m 30 ms see rated control supply voltage U S Current consumption of the control input 24 V DC 1.07 ma 230 V AC 1.524 ma 115 V AC 1.29 ma Timing circuit Kind of timer Single function timer Pulse generator, starting with ON or OFF Time ranges 0.05 s 100 h Recovery time Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states 0.05 1 s, 0.5 10 s, 5 100 s, 0.5 10 min, 5 100 min, 0.5 10 h, 5 100 h < 50 ms Δt < 0.005 %/V Δt < 0.06 %/ C Control supply voltage / timing U: green LED V: control supply voltage applied Control supply voltage / timing U: green LED W: timing Relay status R: yellow LED V: output relay energized Output circuits Kind of output 15 16/18 Relay, 1. c/o contact Contact material Rated operational voltage U e Derating Minimum switching voltage / Minimum switching current Cd free 250 V 12 V / 100 ma 3

Output circuits Maximum switching voltage / Minimum switching current see load limit curve / see load limit curve Rated operational current I e (IEC 60947 5 1) AC12 (resistive) at 230 V 6 A AC15 (inductive) at 230 V 3 A Mechanical lifetime Electrical lifetime Short circuit resistance, maximum fuse rating (IEC/EN 60947 5 1) DC12 (resistive) at 24 V DC13 (inductive) at 24 V n/c contact n/o contact 6 A 2 A 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles (AC12, 230 V, 4 A) 6 A fast acting 10 A fast acting General data Duty time 100 % Repeat accuracy (constant parameters) Δt <± 0.5 % Dimensions (W x H x D) Weight Mounting position Minimum distance to other units 17.5 x 70 x 58 mm (0.69 x 2.76 x 2.28 inches) approx. 60 g (approx. 0.13 lb) normal operation mode horizontal none vertical Mounting DIN rail (EN 60715), snap on mounting without any tool Degree of protection enclosure / terminals IP50 / IP20 any none Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule Screw connection 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) rigid 2 x 0.5 1.5 mm 2 / 1 x 0.5 4 mm 2 (2 x 20 16 AWG) / (1 x 20 12 AWG) 7 mm (0.28 inches) 0.5 0.8 Nm Environmental data Ambient temperature range operation 20...+60 C storage 40...+85 C Damp heat, cyclic (IEC/EN 60068 2 30) Vibration, sinusoidal (IEC/EN 60068 2 6) Shock, half sine (IEC/EN 60068 2 27) 6 x 24 h cycles, 55 C, 95 % RH 4 m/s 2, 20 cycles, 10...150...10 Hz 100 m/s 2, 11 ms Isolation data Rated isolation voltage U i Output circuit 1 / Output circuit 2 300 V Input circuit / Output circuit 300 V Rated impulse withstand voltage U imp (type test) (IEC/EN 60664 1, VDE 0110) between all isolated circuits 4 kv; 1.2/50 µs 4

Isolation data Power frequency withstand voltage test (Test voltage, routine test) between all isolated circuits 2.5 kv, 50 Hz, 1 s Basic insulation (IEC/EN 61140) Input circuit / Output circuit 300 V Protective separation (IEC/EN 61140, VDE 0106 part 101 and part 101/A1) Pollution degree (IEC/EN 60664 1, VDE 0110, UL 508) Overvoltage category (IEC/EN 60664 1, VDE 0110, UL 508) Input circuit / Output circuit 250 V 3 III Standards / Directives Product standard EMC Directive Low Voltage Directive RoHS Directive IEC 61812 1, EN 61812 1 + A11, DIN VDE 0435 part 2021 2004/108/EC 2006/95/EC 2002/95/EC Electromagnetic compatibility Interference immunity IEC/EN 61000 6 1 IEC/EN 61000 6 2 electrostatic discharge (ESD) IEC/EN 61000 4 2 Level 3 (6 kv / 8 kv) electromagnetic field (HF radiation resistance) IEC/EN 61000 4 3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000 4 4 Level 3 (2 kv / 5 khz) powerful impulses (Surge) IEC/EN 61000 4 5 Level 4 (2 kv L L) HF line emission IEC/EN 61000 4 6 Level 3 (10 V) Interference emission IEC/EN 61000 6 3 IEC/EN 61000 6 4 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 5

Technical diagrams Load limit curve AC voltage [V] resistive load 2CDC 252 044 F0207 DC voltage [V] resistive load 2CDC 252 045 F0207 AC current [A] DC current [A] AC load (resistive) DC load (resistive) Derating factor F Derating factor F 1.0 0.9 0.8 0.7 2CDC 252 124 F0206 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ for inductive AC load Contact lifetime Switching cycles 250 V resistive load 2CDC 252 123 F0206 Switching current [A] 6

Dimensions in mm 0.69 17,5 0.2 5 58 2.28 43,4 1.71 70 2.76 45 1.77 2CDC 252 131 F0b06 CT-TGD.12 Synonyms Used expression Alternative expression(s) Used expression Alternative expression(s) 1 c/o contact 1 SPDT voltage related wet / non floating Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x You can find the documentation in the internet under www.abb.com/lowvoltage R Control Products R... 7

STOTZ KONTAKT GmbH As part of the on going product improvement, reserves the right to modify the characteristics of the products described in this document. The information given is non contractual. For further details please contact (www.abb.com/contacts) the company marketing these products in your country. Document number: 2CDC 111 062 D0201 (12/2007) Eppelheimer Strasse 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products