Range: Range: ANSI: IEC: 1.6 1.5 1.4 1.3 1.1 0.9 0.8 0 10 20 30 40 50 60 70 80 90



Similar documents
Alkaline-Manganese Dioxide

Eveready Carbon Zinc (Zn/MnO ² ) Application Manual

DELIVERY SPECIFICATIONS

What are the technical features and performance of the AccuCell system?

Alkaline Manganese (Mercury free) IEC: LR03; JIS: AM-4; ANSI: AAA; MN2400; Micro chemical system: Zn / KOH-H 2 O / MnO 2

Evaluation of Proactive, Reactive and Hybrid Ad hoc Routing Protocol for various Battery models in VANET using Qualnet

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

Energizer Non-Rechargeable Batteries: Frequently Asked Questions

TRANSPORT OF DANGEROUS GOODS

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

A23 TECHNICAL SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY DATE : 21/8/2003

EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

SANYO ENELOOP, The Ultimate NiMH Rechargeable AA & AAA Batteries.

Handbook. We aim to bequeath a beautiful Earth for our future generations.

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Li-ion Rechargeable Battery. Specification

Superior Lithium Polymer Battery

LITHIUM BATTERY CR123A SPECIFICATION

Carefree Sealed Lead Acid (SLA) MSDS

NP Series VALVE REGULATED LEAD-ACID BATTERIES

Lithium Ion Battery Specifications

Height w/o Terminals (in)

li-ion Polymer Battery Specification

Battery Recycling and You

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

Smart Batteries and Lithium Ion Voltage Profiles

Selecting the Optimal Battery for your Embedded Application

1.5 Volt vs. 1.2 Volt Batteries

Inside the Nickel Metal Hydride Battery

Application Manual. Nickel Cadmium 11/06/01 Page 1 of 12

uclamp3301h Low Voltage μclamp TM for ESD and CDE Protection PRELIMINARY Features

Lithium-ion battery technology: Getting the most from Smart Batteries

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Which Battery Is Better? Amber Hess. 6 th Grade Science Mrs. Garmon 1 March 1999

Title Li-ion Battery Specifications (Steel) Page 1/11

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Height w/o Terminals (in)

The Past, Present and Future of Batteries and Microbatteries

Spec. No. ICR C Version No. 0.0

DC Electronic Loads 8500 series

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Capacity Testing of VRLA Batteries (20 to 200 Ampere-Hours Capacity)

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

Product Specification

Li-ion Polymer Battery Specification

The Future of Battery Technologies Part I

6 ELECTRICAL PARAMETERS

An Investigation of Alternatives to Miniature Batteries Containing Mercury

Ametek Prestolite Power AC power / Charger / Battery terms

Practical Examples of Galvanic Cells

Li-Polymer Battery Technology Specification

LI-POLYMER BATTERY PACKS. Specification. Type: mAh. Prepared/Date Auditing/Date Approved/Date WANG MAR 16, 2006 LI MAR 16, 2006

Safety Data Sheet SECTION 1: IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

Odyssey of the Mind Technology Fair. Simple Electronics

Lithium Carbon Monofluoride Coin Cells in Real-Time Clock and Memory Backup Applications

Advanced Systems Tester 900AST

HYDRUS ULTRASONIC METER

Discontinued. LUXEON V Portable. power light source. Introduction

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

In The fastest growing battery system, lithium ion (Li-ion) batteries are used where high-energy density and

uclamp0541z Ultra Small μclamp 1-Line ESD Protection

Handheld portable appliance testers

TABLE OF CONTENTS INTRODUCTION AND BATTERY TERMINOLOGY... 3

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Constant Voltage Charger Selection for VRLA Batteries

Scraper Passage Indicator. Electrical Indicator. Features

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

handbook, 2 columns handbook, halfpage 085 CS

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

SELECTION GUIDE FIFTH EDITION

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

1SMB59xxBT3G Series, SZ1SMB59xxT3G Series. 3 Watt Plastic Surface Mount Zener Voltage Regulators

Battery Cell Balancing: What to Balance and How

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

LITHIUM HANDBOOK ± ± INDUSTRIAL BATTERIES FOR Insulating PROFESSIONALS APPLICATIONS 15.

MPR-Systems. Mini Power Racks 1200 W W

PRODUCT SPECIFICATION

Electrical Double Layer Energy Storage Capacitors Power and Energy Versions

Temperature Compensated Charging of Lead Acid Batteries

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Characteristics Values Units. Rectangular waveform 0.5 A. range - 55 to 150 C

If you accidentally get battery acid on your skin, flush it with lots of water

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

AM/FM Stereo Portable Radio ( ) Features Faxback Doc. # 19744

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

How Batteries Work by Marshall Brain

Product Specification

Specification. Li-ion Rechargeable Battery

SpO2 PULSE OXYMETER MD-300

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Transcription:

MN2400 Size: AAA (LR03) Alkaline-Manganese Dioxide Battery Zn/MnO2 Nominal Voltage: Operating Voltage Impedance: 1.5 V 1.6-0.75V 250 m-ohm @ 1kHz Typical Weight: 11 gm (0.4 oz.) Typical Volume: 3.5 cm 3 (0.2 in. 3 ) Terminals: Storage Temperature Range: Flat -20 o C to 35 o C 3.8 mm Max ( + ) φ 10.5 9.5 mm 0.8 mm MIN. Operating Temperature Range: ANSI: IEC: -20 o C to 54 o C (-4 o F to 130 o F) 24A LR03 44.5 43.5 mm ( ) Dimensions shown are ANSI standards 1.6 1.5 1.4 1.3 TYPICAL DISCHARGE CHARACTERISTICS AT 21 C (70 F) 5.1 OHMS 10 OHMS 24 OHMS 43 OHMS 75 OHMS Voltage 1.2 1.1 1 0.9 0.8 0 10 20 30 40 50 60 70 80 90 Service Hours * Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. MN2400_US_CT.PDF Page 1 of 2 This data is subject to change. Performance information is typical. Contact Duracell for the latest information

SPECIFICATION SUMMARY: ALKALINE PRIMARY CELLS & BATTERIES SELECTED PRODUCTS DURACELL alkaline-manganese dioxide batteries are a popular choice for most consumer, industrial, and military applications where an economical, general purpose battery is required. Advantages include high energy output, reliability, long shelf life, and good low temperature performance. (1) The DURACELL alkaline battery system is generally available in cylindrical and multicell configurations. DURACELL PRODUCT NUMBER SIZE VOLTAGE (V) DIMENSIONS (2) WEIGHT VOLUME CROSS REFERENCE mm in. mm in. mm in. g oz. cm 3 in 3 ANSI IEC STANDARD CYLINDRICAL CELLS DIAMETER HEIGHT MN1300 D 1.5 34.2 1.35 61.5 2.42 - - 139 4.90 56.4 3.44 13A LR20 MN1400 C 1.5 26.2 1.03 50 1.97 - - 69.0 2.43 26.9 1.64 14A LR14 MN1500 AA 1.5 14.5 0.57 50.5 1.99 - - 23.8 0.84 8.4 0.51 15A LR6 MN2400 AAA 1.5 10.5 0.41 44.5 1.75 - - 11.0 0.39 3.8 0.23 24A LR03 MN9100 N 1.5 12 0.47 30.2 1.19 - - 9.6 0.34 3.4 0.21 910A LR1 ULTRA CYLINDRICAL CELLS DIAMETER HEIGHT MX1300 D 1.5 34.2 1.35 61.5 2.42 - - 147 5.19 56.4 3.44 13A LR20 MX1400 C 1.5 26.2 1.03 50.0 1.97 - - 71.7 2.53 26.9 1.64 14A LR14 MX1500 AA 1.5 14.5 0.57 50.5 1.99 - - 24.4 0.86 8.4 0.51 15A LR6 MX2400 AAA 1.5 10.5 0.41 44.5 1.75 - - 11.2 0.40 3.8 0.23 24A LR03 MX2500 AAAA 1.5 8.3 0.33 42.5 1.67 - - 6.0 0.21 2.3 0.14 25A LR8D425 OTHER SELECTED MULTICELL BATTERIES LENGTH HEIGHT WIDTH MX1604 ULTRA 9-VOLT 9 26.5 1.04 48.5 1.91 17.5 0.69 46.5 1.64 22.8 1.39 1604A 6LR61 MN1604 9-VOLT 9 26.5 1.04 48.5 1.91 17.5 0.69 45.0 1.60 22.8 1.39 1604A 6LR61 7K67 J 6 35.6 1.40 48.5 1.91 9.1 0.36 34.0 1.20 15.7 0.96 1412AP 4LR61 MN908 LANTERN 6 67.0 2.64 115 4.53 67.0 2.64 612 21.6 501.8 30.6 908A 4LR25X MN918 LANTERN 6 136.5 5.37 127 5.00 73.0 2.87 1270 44.8 1243.5 75.9 918A 4LR25-2 MN1203 LANTERN 4.5 62.0 2.44 67.0 2.64 22.0 0.87 154 5.43 91.4 5.58-3LR12 MN21 CYLINDRICAL 12 10.3 0.41 28.5 1.12 - - 7.40 0.26 2.30 0.14 - - (1) Operating temperature range is -20ºC to 54ºC (-4ºF to 130ºF) (2) Dimensions are IEC/ANSI standards.

Introduction Duracell pioneered the alkaline-manganese dioxide electrochemical system nearly 40 years ago. In the 1960-1970 decade, this battery system rapidly became the popular choice of designers in the ever-widening field of consumer electronics. The product information and test data included in this technical bulletin represent Duracell s newest alkaline battery products. The zinc/potassium hydroxide/manganese dioxide cells, commonly called alkaline or alkaline-manganese dioxide cells, have a higher energy output than zinc-carbon (Leclanche) cells. Other significant advantages are longer shelf life, better leakage resistance, and superior low temperature performance. In comparison to the zinc-carbon cell, the alkaline cell delivers up to ten times the ampere-hour capacity at high and continuous drain conditions, with its performance at low temperatures also being superior to other conventional aqueous electrolyte primary cells. Its more effective, secure seal provides excellent resistance to leakage and corrosion. The use of an alkaline electrolyte, electrolytically prepared manganese dioxide, and a more reactive zinc powder contribute to a higher initial cost than zinc-carbon cells. However, due to the longer service life, the alkaline cell is actually more cost-effective based upon cost-per-hour usage, particularly with high drains and continuous discharge. The high-grade, energy-rich materials composing the anode and cathode, in conjunction with the more conductive alkaline electrolyte, produce more energy than could be stored in standard zinccarbon cell sizes General Characteristics The general characteristics listed below are a summary of the significant benefits of the alkaline manganese dioxide system. Each of the benefits is explained in greater detail subsequently in Section 5. This summary provides the designer with general guidelines for evaluating the alkaline-manganese dioxide system for a particular application. Benefits include: Up to ten times the service life of regular zinc-carbon cells. Long service life at continuous, high drain discharge. No need for rest periods. Low internal resistance. Rugged, shock-resistant construction. Cost-effective on a cost-per-hour-of-service basis. Good low temperature performance. Excellent leakage resistance. Long shelf life. Worldwide availability at retail. 1

Performance Characteristics (cont.) performance of alkaline and regular zinc-carbon cells is compared in Figure 9, showing the D size cell at 70 F (21 C) and 32 F (0 C). Figure 9a shows AA cell performance under the same conditions. The alkaline cell will maintain a higher voltage for considerably longer than the regular zinc-carbon cell, resulting in a service life at lower temperatures which is up to ten times that of the regular zinc-carbon cell. 5.5 Internal Resistance Alkaline cells, because of their compact construction and highly conductive electrolyte, have low internal resistance, usually less than 1 ohm. The low internal resistance characteristic is a benefit in applications 5.6 Energy Density Energy density is a measure of available energy in terms of weight and volume. It is the ratio of a cell s capacity to either its volume or weight and can be used to evaluate a cell s performance. Table 1 is a summary of the major alkaline product types comparing both volumetric energy density and gravimetric energy density. Volumetric energy density involving high current pulses. Unlike regular zinc-carbon cells, alkaline cells do not require rest periods between pulses and maintain their low internal resistance, increasing only at the very end of useful life. is an important factor where battery size is the primary design consideration. Gravimetric energy density becomes important where weight of the battery is critical, such as in portable computers and cellular phones. The values shown in this table are typical for each cell size. Actual energy output will vary, dependent mostly on drain rates applied. PRODUCT RATED TYPICAL GRAVIMETRIC TYPICAL VOLUMETRIC NUMBER SIZE VOLTAGE CAPACITY* LOAD WEIGHT VOLUME ENERGY DENSITY** ENERGY DENSITY volts ampere-hours ohms pounds kilograms cubic inches liters watt-hours per pound watt-hours per kilogram watt hours per cubic inch watt hours per liter MN1300 D 1.5 15.000 10 0.304 0.138 3.440 0.056 59.2 130 5.2 322 MN1400 C 1.5 7.800 20 0.143 0.065 1.640 0.027 65.5 144 5.7 347 MN1500 AA 1.5 2.850 43 0.052 0.024 0.510 0.008 65.8 143 6.7 428 MN2400 AAA 1.5 1.150 75 0.024 0.011 0.230 0.004 57.5 126 6.0 345 MN9100 N 1.5 0.800 100 0.021 0.010 0.210 0.003 45.7 96 4.6 320 7K67 J 6.0 0.580 340 0.075 0.034 0.960 0.016 37.2 82 2.9 174 MN908 Lantern 6.0 11.500 15 1.349 0.612 30.620 0.502 40.9 90 1.8 110 MN918 Lantern 6.0 24.000 9 2.800 1.270 75.880 1.243 41.1 91 1.5 93 MN1604 9V 9.0 0.580 620 0.101 0.046 1.390 0.023 41.4 91 3.0 182 * TO 0.8V per cell at 21 C (70 F). ** Based on 1.2 volt average operating voltage per cell at 21 C (70 F). Table 1. Comparison of typical energy densities of major DURACELL alkaline cells/batteries. To determine the practical energy density of a cell under specific conditions of load and temperature, multiply the ampere-hour capacity that the cell delivers under those conditions by the average discharge voltage, and divide by cell volume or weight. Gravimetric Energy Density: (Drain in Amperes x Service Hours) x Average Discharge Voltage = Watt-Hours Weight of cell in Pounds or Kilograms Pound or Kilogram Volumetric Energy Density: (Drain in Amperes x Service Hours) x Average Discharge Voltage = Watt-Hours Volume of cell in Cubic Inches or Liters cubic Inch or Liter 8

Applications DURACELL alkaline batteries-with their superior drain rate characteristics good shelf storage life low internal resistance, and wide operating temperature range-are a popular choice for many portable power applications. The most common uses are found in the consumer market, in applications such as photographic equipment, remote control devices, toys, electronic games, flashlights, tape recorders, home health care devices, radios, shavers, clocks, calculators and computers. Alkaline cells also have significant application presence in the industrial and government sectors. Some industrial applications include portable medical and industrial instrumentation, portable and emergency lighting products, communications equipment, and portable electrical measurement devices. Military applications include a variety of communication devices and general instrumentation. Duracell is actively involved in the development of battery products that can power applications currently utilizing rechargeable batteries or AC power, such as notebook computers, handheld cellular phones, camcorders, power tools, and more. The goal of this development program is to provide customers with a primary battery option where needed. Battery Care 7.1 Storage Conditions Batteries should be stored at temperatures between 50 F (10 C) and 77 F (25 C), with relative humidity not exceeding 65 percent. Refrigeration of alkaline batteries is not necessary because of their very good capacity retention. Excessive temperature cycling and storage at temperatures greater than 77 F (25 C) should be avoided to maximize shelf life. 7.2 Proper Usage and Handling Discharged batteries should be removed from equipment to prevent possible damage. Batteries should be removed from a device when it is not expected to be in use for several months. Batteries should also be removed from equipment while it is being powered by household (AC) current. Always replace all batteries at the same time since batteries in series, in different states of discharge, may eventually drive the weakest battery into voltage reversal with progressive risk of leak age or rupture. Mixing battery systems, such as 7.3 Charging All batteries listed in this bulletin are of the primary type and are not designed to be recharged. Attempts to recharge an alkaline battery may cause an alkaline with zinc-carbon, may also result in voltage reversal and should be avoided. Always replace the battery or batteries in your equipment with the size and type of battery specified by the equipment manufacturer. Keep batteries away from small children. If swallowed, consult a physician at once. (For information on treatment, telephone the National Capital Poison Center, Washington, D.C., at 202-625-3333 collect.) imbalance within the cell, leading to gassing and possibly explosion on either charge or discharge cycles. 11