1. SAFETY INFORMATION

High precision counting scale. Operation Manual. l RCZ-A Series

XP Series Balances Operation Manual

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

OCSM Series. High Resolution Digital Crane Scale. User Guide

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

OCS-S High Resolution Digital Crane Scale

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Keep it Simple Timing

Operating instructions Platform/floor scales

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Manual for CH-PFC76810

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Troubleshooting and Diagnostics

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Transmitter Interface Program

SNMP Web Management. User s Manual For SNMP Web Card/Box

User Manual WatchPower

1 Serial RS232 to Ethernet Adapter Installation Guide

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

User Manual. Humidity-Temperature Chart Recorder. Model RH520

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

SA-9600 Surface Area Software Manual

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

The Answer to the 14 Most Frequently Asked Modbus Questions

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SOUND LEVEL METER 94405

Back-UPS Pro 1300/1500 Installation and Operation

SMS Alarm. User Manual

How-To Set Custom Scale Format for FedEx Ship Manager

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

How To Use A Power Supply Unit (Upu)

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

INSTRUCTION MANUAL DTH Fax: (503)

KD-204. Telephone Remote Switch. Operating Instructions

User s Manual. Management Software for Inverter

ANALYTICAL BALANCE OPERATION MANUAL. (FA/JA Series)

User Manual. Video Doorphone CDV-1020AQ

4-Channel Thermometer / Datalogger

Driver Installation and Hyperterminal Operation of iload Digital USB Sensors

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PRT3 Printer Module: ASCII Protocol Programming Instructions

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

GSM HOME SECURITY SYSTEM

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Remote control circuitry via mobile phones and SMS

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

INDUSTRIAL INSTRUMENTATION

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

PPM Users Manual Signature Software

User Guide Reflow Toaster Oven Controller

Fuel Alert FA-KRS-P21. Mounting instruction

How To Use A Brother Ql700

is then retained absolutely without interruption.

Digital Weight Indicator Setup / Operation Manual

RAINCONTROL LCD Special

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

SHENZHEN JUNSI ELECTRONIC CO.,LTD

Laser Barcode Scanner User s Manual

CHD603BM-U USB Mifare Card Reader User Manual

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

How To Program An Autodialer

AD-01 Slave Auto Dialer. Owner s Manual

Laser Barcode Scanner

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

User Guide. Temperature and Humidity Datalogger. Model 42280

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

MAGICAR M871A. Car alarm with two-way remote User s guide

My Weigh Ultraship Series User Manual

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

NC-12 Modbus Application

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Transcription:

DD-KC1 Indicator Operation Manual (V0316) North America Toll Free: 1-855-ANYLOAD (269 5623) Fax: +1-866-612-9088 http://www.anyload.com info@anyload.com

Contents 1. Structure and Installation.1 2. Packing List.1 3. Buttons Functions.1 4. Operation Method.2 4.1 Turn on and off.2 4.2 Connecting the load cell.2 4.2.2 Load cell output sensitivity.3 4.3 Weighing 3 4.4 Animal Weighing/Hold (On by default)..3 4.5 Calibration Methods.3 4.5.1 Random Single-Point Calibration...3 4.5.2 Standard Two Point Weight Calibration....4 4.6 Changing Units..5 4.7 Hold Function.5 4.8 Print Function 5 4.9 Counting Sample.5 4.10 Serial Port Printout...6 5. Factory parameter settings....7 6. Set User Parameter..8 7. Meaning of Cue Code..9 8. Maintenance of Scale..9 9. Malfunction. 10 10. Specification 11

1. Structure and Installation 2. Packing List 1 Indicator 2 AC Adapter 3 Instruction 4 Guarantee Statement 1 piece 1 piece 1 copy 1 copy 3. Buttons Functions Table 1 Key Function Menu Function Serial port order code Turn on/off Null O Switch the unit Go Down on menu or parameters U Hold / Print function Tare Go Up on menu or parameters Enter menu or confirm the change of parameters H T 1 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

4.Operation Method 4.1 Turn on and off Adapter: Insert the plug of AC Adapter into the power supply hub which is on the left of the Display Indicator, and insert the AC Adapter into AC socket. Battery:Open the battery cover which is on the right of the Display Indicator, load 4 x AAA alkaline cells into the cell box (note the polarity) and then close the battery cover. Empty the platform, press Maximum Capacity and Division. object. When power-on, press button once, it will show all the characters then the After the screen displays 0, you can begin to weigh the button to turn off the scale. 4.2 Connecting the Load Cell The connection of the four wire load cell and the indicator: Connect +EXC with the red wire of the indicator s cable. Connect EXC with the black wire of the indicator s cable. Connect +SIG with the green wire of the indicator s cable. Connect SIG with the white wire of the indicator s cable. The indicator provides driving voltage through +EXC wire and EXC wire. +SIG wire and SIG wire will transmit the change of signal voltage to the indicator. *To avoid short circuit, please make sure the welding parts of all the wires covered by the heat shrinking tube. Figure: Connection of the Load Cell and the indicator 2 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

4.2.2 Load cell output sensitivity: 1~2m V/V 4.3 Weighing When power-on, with nothing on the platform, press button once, the instrument will then display 0. Place an object on the platform. After the kg, lb or pcs character stops flashing, which means that the data is stable, you can begin to read it. 4.4 Animal Weighing/Hold (On by default) When the scale is on, press and hold key until the display "0FF" or "ON", then release. This will turn off/on animal weighing/hold. When the running person symbol above the units symbol flashes, the current mode is animal weighing/hold. In this state, once the weighing is stable, it will automatically hold for about 10 seconds. 4.5 Calibration Methods 4.5.1 Random Single-Point Calibration a) At weighing mode, press and hold button until the window displays ------ ; b) Press or buttonuntil display shows CAL ; c) Press button to enter the calibration mode; d) After entering the calibration mode, the window will display Load and 0.0kg alternately,which means that the weight 0.0kg should be loaded on the platform. e) After making sure that there is nothing on the platform, press button to confirm so that the scale begins 0.0kg calibration. In the process of 0.0kg calibration, 0.0kg will flicker rapidly on the display window;keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing remains stable for longer than 2s, the scale will finish 0.0kg calibration automatically, it will then begin the next calibration point; otherwise, 0.0kg will keep flickering to wait for the scale to the stabilize. f) Suppose that the next calibration point should be xx.xkg, the window will display Load and xx.xkg alternately,which means that the weight xx.xkg (WEIGHT) 3 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

should be loaded on the platform. If you have to change this weight, you can press or button to enter the modify menu; press button to change the flashing position and press button to make the flashing position s number plus 1, and press button to finish the modification g) After making sure the weight on the platform is xx.xkg, press button to confirm so that the scale begins the xx.xkg calibration. In the process of xx.xkg calibration, xx.xkg flickers rapidly on the display window;keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing remains stable for more than 2s, the scale will finish xx.xkg calibration and save the calibrated parameters, The indicator will return to the weighing mode 4.5.2 Standard Two Point Weight Calibration a) At weighing mode, press and hold button until the window displays ------ ; b) Press or button to cycle the display until the window displays Line ; c) Press button to begin calibration procedure; d) After the scale begins to calibrate, the window will display Load and 0.0kg alternately; e) After you confirm that there is nothing on the platform, press button to confirm and begin the zero calibration when the window displays 0.0kg. In the process of zero calibration, 0.0kg flickers rapidly on the display window;please keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing keeps stable exceeding 2s, the scale will finish zero calibration automatically, and then it will begin the next calibration point; f) Repeat the step d) and step e) above,calibrate the half capacity range point and the Full capacity range point orderly, save the calibrated parameters automatically and return to the weighing mode. 4 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

4.6 Changing Units Press the button to switch the unit of measurement, kg --- lb--- pcs--- kg. 4.7 Hold Function Once the key is pressed: 4.7.1 The CPU will send the weight data into RS232 socket. 4.7.2 The weight will remain on the display for 120 seconds after the item has been removed from the scale so the weight can beeasily read. a) Place the item on the scale platform. b) Wait for the display to show a stable weight. c) Press the key. Display will show HOLD. Remove the item from the scale platform. The item s weight reading will remain on the display for 120 seconds. d) When you want to quit the hold function, press the key and HOLD will disappear. 4.8 Print Function Press and hold the for 3 seconds, the buzzer will sound, and the weight data will export to the computer or the serial printer. 4.9 Counting Sample a. During counting mode, remove unrelated objects on the platform, then press button to revert to zero; b. Press button to switch the unit into PCS, and the window will display ADD10. c. ADD10 means that 10 objects to be weighed should be added onto the platform. Attention: The weight of each sample should be higher than the scale s minimum division value; otherwise, the window will display NO. d. If you want to change the sampling quantity, please press the button to change the quantity; if you do not need to sample again, press the button to 5 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

cancel the sampling, and the scale will adopt last sampling value to count ; e. After you confirm the quantity of objects on the platform and the data displayed on the LCD are the same, short press to confirm, and then begin to sample and count; f. During the process of sampling and counting, the screen will display the sampling data by rapidly flickering; keep the platform calm, stable, and without other interference factors that would influence the weighing performance. If the weighing stays stable for longer than 2s, the sampling and counting will be automatically finished. The parameter will be saved automatically and the scale will return to counting mode; if not, the screen will keep flickering the data and waiting for the stability of measuring. 4.10 Serial Port Printout a.connect the serial port with the scale according to the drawing below. Baud Rate=9600,without parity digit, sent stop bit 1 (The serial connection diagram is omitted); b. Open the serial communication software, for example, HyperTerminal in windows. Select the connected portal number COM and set the baud rate as 9600bps, the parity bit as NONE, the data bit as 8Bit, and the stop bit as 1Bit. c. You can select the serial output modes according to your own needs. The output modes include 3 types: output by pressing button, automatic output after the weight keeps stable, and continuous output. You can set though the out in Parameter setting. 6 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

d. Output Data Form: 8 bytes data bit + 3 bytes unit code + 2 bytes ending code. The above-mentioned characters are all ASCII codes, and the unit can be kg, lb or pcs. e. The serial ports order can be found in Chapter 2 button function. Example of Output Data: Display Data Bit Unit Code Ending Code 1 2 3 4 5 6 7 8 9 10 11 12 13 123.45kg Blank Blank 1 2 3. 4 5 k g Blank CR LF -123.45lb Blank - 1 2 3. 4 5 l b Blank CR LF 123.0pcs Blank Blank Blank 1 2 3. 0 p c s CR LF 5 Factory parameter settings 1. Turn off the scale, then hold the three buttons:, and at the same time until the screen displays ------ ; 2. Press or button to go through the menu; 3. Press button to enter the display menu.; 4. After entering the display menu, Press or key to select parameters; Press button to verify the parameters and return to the menu; 5. After all the parameters are set, go to -End- in the menu, short press button to save and exit to weighing or counting mode Menu Meaning of Menu Selective Parameter 1.dP Decimal Point Setting 0/0.0/0.00/0.000/0.0000 2.CAP Capacity setting 3000,6000,7500,8000,10000,12000, 15000,20000,30000,50000,60000 75000,80000,100000,120000,150000,200000,300000 3.InC Division setting d=1/2/5 -End- Save and Exit 7 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

6 Set User Parameter a) When the scale is off, please press button together with the button to turn on the scale. Do not release the button until the screen displays ------ ; b) Press the or button to switch the menu; c) Press the button to enter the display menu; d) After entering the display menu, press the or button to select the parameter; e) Press the button to confirm the parameter, and return to the menu; f) After all the parameters have been set, switch the menu to -End-,and press the button to finish the setting and save the parameters, then return to the weighing or counting mode. 8 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 ) Table 3 Menu Meaning of Menu Selectable Parameter Meaning of Parameter 1.codE Check the internal null Check the internal code for code debugging by manufacturer. 2.ASt Zero tracking range 0.5/1/2/3d Set automatic zero tracking range. 3.out Printout method key/auto/conti key:printout while press the key, Auto : printout automatically,conti:printout continuously 4.LEd Backlight control method 5.OFF Automatic shutdown control 6.-LL- Set Lower limit alarm 7.-HH- Set upper limit alarm OFF/Auto/on no/3/510/15/30/60 min xxxx ( lower value) xxxx ( upper value) limit limit OFF:backlight is turned off, Auto:backlight is automatic, On:backlight is turned on. no:no automatic shutdown; 3~60min:if there is not any action of weighing objects or pressing buttons, the instrument will automatically turn off. If the lower limit value is set to 0, the lower limit alarm function is canceled. If the upper limit value is set to 0, the upper limit alarm function is canceled.

-End- Finish measuring and save the parameters null 7.Meaning of Cue Code Table 4 Display Code Meaning of Code Solution no 1 The calibration weight value is not 1 Load the weight value loaded according to the display when according to the show calibrating. value. 2 The quantity of objects is not loaded 2 Load the quantity according to the quantity of sampling. according to the show value. AC The batteries are dead. 1 Use new batteries. 2 Use power adapter. Err-0 Err-1 1 Lost the calibration data. 2 The load cell or main board maybe damaged. 1 The weight is over the max capacity. 2 Lost the calibration data. 3 The load cell or main board maybe damaged. 1 Re-calibrate. 2 Change the Loadcell or main board. 1 Remove the objects on the platform. 2 Re-calibrate. 3 Change the loadcell or main board. --L-- Lower limit alarm 1 cancel lower limit alarm --H-- Upper limit alarm 1 cancel upper limit alarm 8. Maintenance of Scale In order to keep the scale s normal operating, the indicator and the platform of scale should be kept clean and prevented from corrosion by any foreign substances. If necessary, you should use a piece of cloth with a mild washing agent to clean them. When you don t use the scale, pull out the A/C plug. For long-term storage, please take out the batteries. 9 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

9. Malfunction Phenomenon Reason Solution No display Low-voltage indication Error in weighing data-reading False calibration The power plug is not inserted in the right place. The batteries are expired. The batteries power is low. The scale didn t back to zero before using. The scale is not calibrated. The calibration weight is not precise. Insert the plug in right place. Use the new batteries. Use the new batteries. Table 5 Do not put objects on the platform, press button, and then begin to weight. Re-calibrate. Use the precise calibration weight. 10.Specification Model Capacity x Readability Parts counting DD-KC1 3000e Standard Repeatability (std.dev) 0.03% Linearity 0.03% T range Over range capacity Stabilization time To capacity by subtraction Capacity + 9d 2sec Sensitivity drift (%) 0.01 Operation temperature 10~40 Operation Humidity 85% Power requirements 110 or 220V 50/60Hz AC adapter (included); Or 4 AAA batteries 10 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )

http://www.anyload.com North America Toll Free: 1-855-ANYLOAD (269 5623) Fax: +1 866 612 9088 Email: info@anyload.com 11 A n y l o a d D D - K C 1 M a n u a l V ( 1 6 0 3 )