Agilent U1210 Series Handheld Clamp Meters

Similar documents
Agilent U1230 Series Handheld Digital Multimeters (DMMs)

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Make Better RMS Measurements with Your DMM

Agilent E5063A ENA Series Network Analyzer

Agilent 87421A/87422A Power Supply

802.11ac Power Measurement and Timing Analysis

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent U1270 Series Handheld Digital Multimeters

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Fluke 3000 FC Series Test Tools Technical Data

Agilent 4338B Milliohm Meter

Agilent 4339B/4349B High Resistance Meters

DDR Memory Overview, Development Cycle, and Challenges

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent U2000 Series USB Power Sensors

Agilent FieldFox Remote Viewer

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Digital Clamp-on DMMs with uncompromising performance

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent Television Power Consumption Testing. Application Note

Fluke 3000 FC Series Test Tools Technical Data

Evaluating Oscilloscope Bandwidths for Your Application

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

UT202A Operating Manual. Contents

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent 8762/3/4A,B,C Coaxial Switches

Model UT33A: OPERATING MANUAL Table of Contents (1)

Agilent P940xA/C Solid State PIN Diode Switches

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent U2000 Series USB Power Sensors

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

AutoRanging Digital MultiMeter

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

1.5 GHz Active Probe TAP1500 Datasheet

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

10 Multimeter. Users Manual

L4940 series VERY LOW DROP 1.5 A REGULATORS

Agilent U2000 Series USB Power Sensors

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

LF00AB/C SERIES VERY LOW DROP VOLTAGE REGULATORS WITH INHIBIT

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

The Next Generation in Automated Oscilloscope Test

Agilent Automotive Power Window Regulator Testing. Application Note

Insulation resistance testing. A complete solution for every person.

Symbol Parameter Value Unit V i-o Input-output Differential Voltage 40 V I O Output Current Intenrally Limited Top

LM118/LM218/LM318 Operational Amplifiers

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

Model UT201/202: OPERATING MANUAL. Table of Contents

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

Description. Table 1. Device summary. Order codes. TO-220 (single gauge) TO-220 (double gauge) D²PAK (tape and reel) TO-220FP

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

AN2866 Application note

Diode, Schottky SMB/DO-214AA. Page <1> 24/04/08 V1.1. Dimensions Inches (Millimeters)

PXI and AXIe Modular Instrumentation

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Intelligent Digital Multimeters

Loop Calibration and Maintenance

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

L78MxxAB L78MxxAC. Precision 500 ma regulators. Features. Description

Model UT58A/B/C: OPERATING MANUAL

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet


E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Handheld portable appliance testers

Agilent E6832A W-CDMA Calibration Application

ABCs of DMMs Multimeter features and functions explained Application Note

TDA W Hi-Fi AUDIO POWER AMPLIFIER

L78M00 SERIES POSITIVE VOLTAGE REGULATORS.

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Table 1. Absolute maximum ratings (T amb = 25 C) Symbol Parameter Value Unit. ISO C = 330 pf, R = 330 Ω : Contact discharge Air discharge

Manual Ranging MultiMeter

TL074 TL074A - TL074B

U1602A Handheld Oscilloscopes, 20 MHz

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Fluke Digital Multimeters Solutions for every need

Ground Resistance Clamp On Tester

STP62NS04Z N-CHANNEL CLAMPED 12.5mΩ - 62A TO-220 FULLY PROTECTED MESH OVERLAY MOSFET

User's Guide. True RMS Industrial Multimeter

Transcription:

Agilent U1210 Series Handheld Clamp Meters Handle big currents more safely Data Sheet Features Large clamp opening of 52 mm or 2 High measurement capability of up to 1000 A for AC, DC or AC+DC CAT III 1000 V/CAT IV 600 V safety rating Bluetooth wireless connectivity (optional U1177A Infrared (IR)-to-Bluetooth Adapter required) Includes full-featured DMM with resistance, capacitance, frequency and temperature functions High resolution measurements measure current as low as 0.01 ma Peak hold Dual ranging mode manual and auto Large dual display Min/max recording capability Measurements of electrical distribution cables can be challenging and risky. For cables up to two inches in diameter, the Agilent U1210 Series handheld clamp meters enable high-current measurements without breaking the circuit. Unlike most clamp meters, they also include DMM capabilities resistance, capacitance, frequency and temperature to simplify troubleshooting during installation and maintenance. Best of all, they provide an extra layer of protection with CAT IV 600V and CAT III 1000 V safety ratings.

Key Measurements Measure current easily and accurately Agilent U1210 Series handheld clamp meters come with clamp opening of 52 mm/2 inches and high current measurement capability of up to 1000 A (AC, DC, AC+ DC). With the large jaw size, these handhelds simplify current measurements for thick cables. Clamp on with the U1210 Series and get convenience, versatility and the ability to handle big currents safely. Full-featured digital multimeter functions The U1210 Series handheld clamp meters provide basic functions of a multimeter with wide measurement ranges to cater for a broad range of applications (ACA, DCV, ACV, OHM, audible continuity, diode and frequency tests). These meters also provide auto-ranging capability, built-in peak hold for in-rush current measurement, temperature and capacitance measurement capability, large backlight display and one-hand operation. Smooth sailing measurements even in a distance Making current measurements can be strenuously demanding due to its complexity and high current involved. Electrical distribution rooms being typically situated at different areas further complicates maintenance and troubleshooting due to the need to commute back and forth to cross check measurement results. By adding the new Bluetooth capability to your existing U1210 series handheld clamp meters, you are able to make high current measurements in a safer and more convenient manner. With the U1177A Infrared-to-Bluetooth adapter, you can easily monitor measurements and log data up 10-metres range across all Android platform devices- an added value for maximum efficiency and productivity in all sorts of hard-toreach environments. 2

Take a Closer Look Large jaw opening of 2 inches to test thick current sources Capacitance/Diode measurement Max or Min recording capability Temperature and audible continuity functions High measurement capability of up to 1000 A for AC, DC or AC+DC Large LCD display with maximum reading of 4000 counts Peak hold function for in-rush current testing Manual or auto ranging 3

General Specifications Title Dimension Net Weight Display Battery Low battery indicator Power consumption Specification U1211A: 106 mm (W) X 273 mm (L) X 43 mm (H) U1212A and U1213A: 106 mm (W) X 260 mm (L) X 43 mm (H) U1211A: 625 grams with batteries included U1212A and U1213A: 525 grams with batteries included 4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph and full annunciator. Automatic polarity indication. Standard 9 V Battery - Alkaline Battery voltage drops below 6.0 V U1211A: 186 mva maximum U1212A and U1213A: 220 mva maximum 60 hours (typical) Battery life Connectivity Wireless Bluetooth compatible Maximum jaw opening ~2 inches Temperature coefficient 0.12 x (specified accuracy)/ C (from 0 to 18 C or 28 to 50 C) NMRR (Normal Mode Rejection Ratio) This series has a NMRR specification of > 60 db at 50 Hz and 60 Hz, which means a good ability to reject the effect of AC noise in DC measurement CMRR (Common Mode Rejection Ratio) U1211A and U1212A have CMRR specifications of > 60 db at DC to 60 Hz in the ACV function; and > 80 db at DC, 50 Hz and 60 Hz in the DCV function. U1213A has a CMRR specifications of > 60 db at DC to 60 Hz in the ACV function; and > 120 db at DC, 50 Hz and 60 Hz in the DCV function. Operating temperature 10 to 50 C, 0 to 80 % R.H. Storage temperature 20 to 60 C, 0 to 80 % R.H. Relative Humidity (R.H.) Maximum 80 % R.H. for temperature up to 31 C decreasing linearly to 50 % R.H. at 50 C Temperature coefficient 0.1 (specified accuracy) / C (from 0 C to 18 C or 28 C to 50 C) Safety compliance EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No.61010-1-04 Measurement category CAT III 1000 V/ CAT IV 600 V EMC compliance Certified to IEC61326-1:2005/ EN61326-1:2006 CISPR 11:2003/ EN 55011:2007 Group 1 class A Canada: ICES-001:2004 Australia/New Zealand: AS/NZS CISPR11:2004 4

Electrical Specifications for U1211A Accuracy is given as ± (% of reading + number of least significant digits) at 23 C ± 5 C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Resolution Accuracy Overload protection 400 V 0.1 V 0.5 % + 5 1000 V 1 V 0.5 % + 3 Input impedance: 10 MΩ (nominal) AC voltage 1000 V R.M.S Accuracy Resolution 45~400 Hz 400 V 0.1 V 1 % + 5 1000 V 1 V 1 % + 5 Input impedance: 10 MΩ (nominal) in parallel with < 100 pf Overload protection 1000 V R.M.S Voltage (1 ms peak hold) Resolution Accuracy Overload protection 400 V 0.1 V 1 % + 43 1000 V 1 V 1 % + 43 Specified accuracy for changes > 1 ms in duration Diode check/audible continuity test 1000 V R.M.S Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 ma < +3.1 V Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current Built-in buzzer sounds when reading is below 50 mv approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Resolution Accuracy Test current 400 Ω 0.1 Ω 0.5 % + 3 0.8 ma 4 kω 0.001 kω 0.5 % + 3 80 µa Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω 4. The accuracy of 400 Ω and 4 kω is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect 5

Electrical Specifications for U1211A (continued) Capacitance Resolution Accuracy Overload protection 400 µf 0.1 µf 2 % + 4 1000 V R.M.S. for circuits 4000 µf 1 µf 3 % + 4 < 0.3 A of short circuit current The accuracy is based on film capacitor or better and use Relative mode to zero residual value AC current Resolution Accuracy *N1 45~65 Hz 65~400 Hz 400 Hz~1 khz 40 A 0.01 A 1.0 % + 10 1.0 % + 10 3.0 % + 10 400 A 0.1 A 1.0 % + 5 1.0 % + 5 3.0 % + 5 400~700 A 1 A 1.0 % + 5 1.0 % + 5 3.0 % + 5 700~1000 A 1 A 1.0 % + 5 None None Maximum overload: The accuracy is specified on the symmetrical waveforms. N1: The maximum verification of current and frequency product is less than 400,000 A x Hz WARNING: The measuring duty cycle should not exceed the following limits. 0 ~ 600 A R.M.S. Continuous 600 ~ 700 A R.M.S. 10 minutes ON, 10 minutes OFF 700 ~ 5 minutes ON, 20 minutes OFF Current (1 ms peak hold) Resolution Accuracy Maximum overload 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1 A 2.0 % + 43 Specified accuracy for changes > 1 ms in duration 6

Electrical Specifications for U1211A (continued) Frequency (AC coupling) Resolution Accuracy Minimum frequency 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 khz 0.001 khz 0.2 % + 3 10 Hz 99.99 khz 0.01 khz 999.9 khz 0.1 khz Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity Frequency sensitivity Minimum sensitivity (R.M.S.) Maximum input for specified accuracy of AC 40 Hz~2 khz 10~40 Hz or 2~100 khz 400 V 6 V 6 V 1000 V 20 V 30 V (< 10 khz) 40 A 3 A (< 1 khz) 3 A (< 1 khz) 400 A 20 A (< 1 khz) 20 A (< 1 khz) 1000 A 50 A (1 khz) 50 A (< 1 khz) 7

Electrical Specifications for U1212A Accuracy is given as ± (% of reading + number of least significant digits) at 23 C ± 5 C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Resolution Accuracy Overload protection 400 V 0.1 V 0.5 % + 3 1000 V 1 V 0.5 % + 3 Input impedance: 10 MΩ (nominal) AC voltage 1000 V R.M.S Accuracy Resolution 45~400 Hz 400 V 0.1 V 1 % + 5 1000 V 1 V 1 % + 5 Input impedance: 10 MΩ (nominal) in parallel with < 100 pf Overload protection 1000 V R.M.S Voltage (1 ms peak hold) Resolution Accuracy Overload protection 400 V 0.1 V 1 % + 43 1000 V 1 V 1 % + 43 Specified accuracy for changes > 1 ms in duration Diode check/audible continuity test 1000 V R.M.S Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 ma < +3.1 V Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current Built-in buzzer sounds when reading is below 50 mv approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Resolution Accuracy Test current 400 Ω 0.1 Ω 0.5 % + 3 0.8 ma 4 kω 0.001 kω 0.5 % + 3 80 µa Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω 4. The accuracy of 400 Ω and 4 kω is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect 8

Electrical Specifications for U1212A (continued) Capacitance Resolution Accuracy Overload protection 400 µf 0.1 µf 2 % + 4 1000 V R.M.S. for circuits 4000 µf 1 µf 3 % + 4 < 0.3 A of short circuit current The accuracy is based on film capacitor or better and use Relative mode to zero residual value DC current Resolution Accuracy Maximum overload 40 A 0.01 A 1.5 % + 15 400 A 0.1 A 1.5 % + 3 1000 A 1 A 2.0 % + 5 Use Relative mode to zero residual offset AC current Accuracy *N1 Resolution 45~65 Hz 65 Hz~1 KHz 40 A 0.01 A 2.0 % + 10 3.0 % + 10 400 A 0.1 A 2.0 % + 5 3.0 % + 5 1000 A 1 A 2.0 % + 5 3.0 % + 5 N1: The maximum verification of current and frequency product is less than 400,000 A x Hz Maximum overload Current (1 ms peak hold) Resolution Accuracy Maximum overload 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1 A 2.0 % + 43 Specified accuracy for changes > 1 ms in duration Temperature test Thermal type Resolution Accuracy K 200 ~ 40 C 0.1 C 1 % + 3 C 40 ~ 1372 C 0.1 C 1 % + 1 C 328 ~ 40 F 0.1 F 1 % + 6 F 40 ~ 2502 F 0.1 F 1 % + 2 F Notes: 1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour 2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard. 3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175 9

Electrical Specifications for U1212A (continued) Frequency (AC coupling) Resolution Accuracy Minimum frequency 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 khz 0.001 khz 0.2 % + 3 10 Hz 99.99 khz 0.01 khz 999.9 khz 0.1 khz Overload protection: 1000 V Sensitivity Frequency sensitivity Minimum sensitivity (R.M.S.) Maximum input for specified accuracy of AC 40 Hz~2 khz 10~40 Hz or 2~100 khz 400 V 6 V 6 V 1000 V 20 V 30 V (< 10 khz) 40 A 3 A (< 1 khz) 3 A (< 1 khz) 400 A 20 A (< 1 khz) 20 A (< 1 khz) 1000 A 50 A (1 khz) 50 A (< 1 khz) 10

Electrical Specifications for U1213A Accuracy is given as ± (% of reading + number of least significant digits) at 23 C ± 5 C, with relative humidity less than 80 % R.H. AC voltage, AC current, AC+DC voltage, AC+DC current specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3. DC voltage Resolution Accuracy Overload protection 4 V 0.001 V 40 V 0.01 V 0.2 % + 5 400 V 0.1 V 1000 V 1 V 0.5 % + 3 Input impedance: 10 MΩ (nominal) AC voltage Resolution 4 V 0.001 V Accuracy 45~400 Hz 400 Hz~2 khz Overload protection 40 V 0.01 V 1.0 % + 5 2.0 % + 5 1000 V R.M.S 400 V 0.1 V 1000 V 1 V Input impedance: 10 MΩ (nominal) in parallel with < 100 pf AC+DC voltage Resolution 4 V 0.001 V Accuracy 45~400 Hz 400 Hz~2 khz Overload protection 40 V 0.01 V 1.5 % + 9 2.5 % + 9 1000 V R.M.S 400 V 0.1 V 1000 V 1 V Input impedance: 10 MΩ (nominal) in parallel with < 100 pf Voltage (1 ms peak hold) Resolution Accuracy Overload protection 4 V 0.001 V 40 V 0.01 V 400 V 0.1 V 1000 V 1 V Specified accuracy for changes > 1 ms in duration 1.0 % + 43 1000 V R.M.S 11

Electrical Specifications for U1213A (continued) Diode check/audible continuity test Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 ma < +3.1 V Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current Built-in buzzer sounds when reading is below 50 mv approximately and single tone for normal forward-biased diode or semiconductor junction as 0.3 V Reading 0.8 V Resistance Resolution Accuracy Test current 400 Ω 0.1 Ω 0.8 ma 4 kω 0.001 kω 80 µa 0.3 % + 3 40 kω 0.01 kω 8 µa 400 kω 0.1 kω 727 na 4 MΩ 0.001 MΩ 0.6 % + 3 112 na 40 MΩ 0.01 MΩ 2.0 % + 5 112 na Notes: 1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current 2. Maximum open voltage: < +3.1 V 3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω 4. The accuracy of 400 Ω and 4 kω is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect Capacitance Resolution Accuracy Overload protection 4 µf 0.001 µf 40 µf 0.01 µf 1 % + 4 400 µf 0.1 µf 2 % + 4 4000 µf 1 µf 3 % + 4 The accuracy is based on film capacitor or better and use Relative mode to zero residual value DC current 1000 V R.M.S. for circuits < 0.3 A of short circuit current Resolution Accuracy Maximum overload 40 A 0.01 A 1.5 % + 15 400 A 0.1 A 1.5 % + 3 1000 A 1 A 2.0 % + 5 Use Relative mode to zero residual offset 12

Electrical Specifications for U1213A (continued) AC current Accuracy *N1 Resolution 45~65 Hz 65 Hz~1 KHz 40 A 0.01 A 2.0 % + 10 3.0 % + 10 400 A 0.1 A 2.0 % + 5 3.0 % + 5 1000 A 1 A 2.0 % + 5 3.0 % + 5 N1: The maximum verification of current and frequency product is less than 400,000 A x Hz Maximum overload AC+DC current Accuracy Resolution 45~65 Hz 65 Hz~1 khz 40 A 0.01 A 3.5 % + 25 4.5 % + 25 400 A 0.1 A 3.5 % + 9 4.5 % + 9 1000 A 1 A 4.5 % + 9 5.0 % + 9 Maximum overload Current (1 ms peak hold) Resolution Accuracy Maximum overload 40 A 0.01 A 2.0 % + 70 400 A 0.1 A 2.0 % + 43 1000 A 1 A 2.0 % + 43 Specified accuracy for changes > 1 ms in duration Temperature test Thermal type Resolution Accuracy K 200 ~ 40 C 0.1 C 1 % + 3 C 40 ~ 1372 C 0.1 C 1 % + 1 C 328 ~ 40 F 0.1 F 1 % + 6 F 40 ~ 2502 F 0.1 F 1 % + 2 F Notes: 1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour 2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard. 3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175 13

Electrical Specifications for U1213A (continued) Frequency (AC coupling) Resolution Accuracy Minimum frequency 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 khz 0.001 khz 99.99 khz 0.01 khz 999.9 khz 0.1 khz Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity 0.2 % + 3 10 Hz Frequency sensitivity Minimum sensitivity (R.M.S.) Maximum input for specified accuracy of AC 45 Hz~2 khz 10 Hz~200 khz 4 V 0.3 V 0.6 V 40 V 2 V 3 V 400 V 20 V 30 V (< 100 khz) 1000 V 50 V 50 V (< 10 khz) 40 A 3 A (< 1 khz) 3 A (< 1 khz) 400 A 20 A (< 1 khz) 20 A (< 1 khz) 1000 A 50 A (< 1 khz) 50 A (< 1 khz) Duty cycle Mode Accuracy of full scale AC coupling 0.1 %~99.9 % 0.3 % per khz + 0.3 % Notes: 1. The accuracy for duty cycle is based on a 4 V square wave input to the DC 4 V range and maximum frequency up to 2 khz. The duty cycle range can be measured within 5 %~95 % as the signal frequency > 20 Hz. 14

Ordering Information Standard shipped accessories Test leads 4-mm probes Soft carrying case Quick Start Guide Certificate of Calibration (CoC) Optional accessories U1168A Standard test lead kit U1162A Alligator clips U1175A Soft carrying case U1186A K-type thermocouple and adapter U1177A Infrared (IR)-to-Bluetooth Adapter Did you know? Ensure that the clamp meter measures only one conductor at a time. Measuring multiple conductors may cause inaccuracy in measurement reading due to vector sum of the currents flowing in the conductors. 15

www.agilent.com www.agilent.com/find/clampmeter myagilent myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Bluetooth and the Bluetooth logo are registered trademarks owned by Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, Inc. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: October 11, 2012 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2012 Published in USA, October 31, 2012 5990-5083EN