Downlighters and fire safety

Similar documents
Guide to the safe installation of downlighters in dwellings

Installation Instructions

Energy efficient lighting for your home find out more.

AS/NZS 3000:2007 Amendment 2

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Safety Storage Cabinets

KIT DOWNLIGHT HALOSPOT 111 ES

IVIOS LED III. LUM Technical Information

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INFRARED QUARTZ WALL HEATER

Medical Lighting. XL4 Patient Light

Features. High Brightness LED Light source

Q1. (a) The graph shows the temperature inside a flat between 5 pm and 9 pm. The central heating was on at 5 pm.

Drayton Digistat +2RF/+3RF

Section 559 luminaires and lighting installations An overview by Geoff Cronshaw

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

Installation Instructions for Alarm Module Kit A043F059

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Page138 Page139 Page140

Operating Instructions Bedienungsanleitung Mode d emploi

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Acclaim III Recessed Fluorescent Luminaires ATEX

LIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Build in self resetting protection systems: short circuit, overwattage overvoltage, thermal.

Decree of the Ministry of the Environment on fire safety of ventilation systems

Ducoterra Radiant Heating Panel Installation Manual

Rockwool Flexi Insulation Application Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electrical Resistance Resistance (R)

Bulb Replacement REPLACING BULBS WARNING

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

VACUUM CLEANER INSTRUCTION MANUAL

Circuit symbol. Each of the cells has a potential difference of 1.5 volts. Figure 1. Use the correct answer from the box to complete the sentence.

aseries A13B Mini Bullet Camera User Manual

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Get your lights right. What you need to know about fitting and using additional vehicle lighting

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Chimneys in Thatched Properties

Electrical installations and their impact on the fire performance of buildings:

Energy Efficiency HOSPITALITY.

Light Source User Guide

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Industrial infrared heater IR For premises with large volumes and high ceilings

TELESTO LED DOWN LIGHT

Kolorlux. GE Lighting DATA SHEET

Home lighting. Bright ideas for energy savings

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Multi-layer Insulation Blanket for Roofs

Installation and safety instructions for AC/DC built-in devices

UV100A Ultraviolet Air Treatment System

TROUBLESHOOTING LED DOWNLIGHTS

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

EBDSPIR-PRM, EBDSPIR-PRM-IP

Wireless 7 Day Programmable Room Thermostat

Wolflite Safety Handlamp H-251E

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Multi-Vapor Metal Halide Lamps

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Meaco 30L and Meaco 40L dehumidifier instruction manual

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Fire-Rated Glass and Glazing START

Frequently Asked Questions About OHP Lamps

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Infrarot-Bewegungsmelder IP44

Do not touch glass part of the bulb with your hands during installation.

Understanding LED Drivers

For use by landlords of small premises Premises Address

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

Fire Safety Risk Assessment Checklist for Residential Care Premises

Having a gas appliance installed or serviced? Doing home improvements?

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Universal Dimmer. 31E2PUD Series PUSH BUTTON. Installation Instructions. Integrally Switched Push-Button INTEGRALLY SWITCHED 240V

Operating instructions

Planning Information. Passenger and Freight Elevators.

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

V94 BULK TAPE DEGAUSSER

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

IMPORTANT SAFETY NOTICE

Energy-efficient lighting

User Manual THR840DUK Digital Thermostat

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

ORLAND FOLLOW PR-1211

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Room Temperature Sensors

Transcription:

INSTALLERS QUICK REFERENCE GUIDE Downlighters and fire safety This guide provides a quick reference for installers on the appropriate selection and installation of downlighters in domestic premises, and on how to prevent them from becoming a fire hazard. www.esc.org.uk

1. Introduction Poorly installed downlighters (recessed luminaires) are the cause of a significant number of fires in homes every year. This guide provides a quick reference for installers on the appropriate selection and installation of downlighters in domestic premises, and on how to prevent them from becoming a fire hazard. 2. Why are downlighters a fire risk? Under normal operating conditions, the surface temperature of tungsten halogen lamps can exceed 200 ºC, which is above the ignition temperature of many combustible materials. Without adequate ventilation to permit safe heat dissipation, downlighters not designed to be covered by thermal insulation, or installed too close to combustible materials (such as roof timbers) can cause fires or harmful thermal effects to their surroundings. Even when insulation is not present, there is a risk that dust, debris and other potentially combustible materials could ignite if they come into contact with the hot lamp. Overheating can occur where thermal insulation is laid over existing downlighters and any associated transformers that are not designed to operate safely under these conditions. The bases of the most common types of push-fit extra-low voltage lamps (with aluminium or dichroic reflectors) are identical (see section 4 for diagrams). However, most types of downlighter are not designed to operate safely with both types of lamp. Consequently, lamps can be fitted inadvertently that exceed the maximum rating of the luminaire or which reflect heat in the wrong direction. 3. Downlighters explained Operating voltage Downlighters operate at mains voltage (230 Volts), or are powered via a transformer at extra-low voltage (12 Volts). Extra-low voltage (ELV) downlighters are often incorrectly described as low voltage on product packaging. Fire performance Downlighters may also be described as Fire rated. This means they have in-built fire protection that completely seals the downlighter in the event of fire in the room below, to prevent the spread of fire and smoke into other areas. It is important that the fire performance of ceiling structures that have a fire containment function or are required to carry load for a prescribed period of time are not compromised by the installation of downlighters.

For ALL downlighters installed in ceilings, the Electrical Safety Council recommends the use of fire rated downlighters fitted with aluminium reflector lamps to help ensure that any fire in the space below is kept out of cavities and that the heat build-up above and within the fitting is minimised. Typical fully closed back fire rated downlighter Typical standard open back downlighter In situations where a selected design or style of downlighter is not available with integral fire protection, additional protection may be fitted at the time of installation in the form of a purpose made fire hood, an insulated fire protection box, or similar. Detailed guidance on the selection of suitable types of downlighter for particular applications is given in the Electrical Safety Council s Best Practice Guide 5 Electrical installations and their impact on the fire performance of buildings. This guide can be viewed and downloaded free from the Council s website at: www.esc.org.uk. Mounting on normally flammable surfaces Downlighters are classified according to whether or not they are suitable for direct mounting on normally flammable surfaces. Normally flammable materials are those which have an ignition temperature of at least 200 C and which will not deform or weaken at this temperature. Examples are, wood and wood-based materials of more than 2 mm thickness. Where a downlighter is suitable for direct mounting on non-combustible surfaces only, either of these warning symbols should be marked on the fitting. Covering with thermal insulating materials To avoid the risk of fire (as well as reduced lamp and service life) caused by overheating, downlighters and any associated transformers must not be covered by thermal insulation and need to be protected against potential or future covering, unless they are specifically designed to operate safely in this condition. Particular care must be taken where loose-filled insulation is present, as this can be moved easily by drafts, vermin, etc, and may then come into contact with the downlighter.

Downlighters marked with Are suitable for covering with thermal insulation Must not be covered with thermal insulation Building Regulations do not prohibit the leaving of a small area around downlighters free from thermal insulation where this is necessary to permit the dissipation of heat they generate. However, due allowance for this should be made in the overall thermal and acoustic performance of the premises. Alternatively, where access to the space above the downlighter can be achieved, a proprietary insulation support box or similar cover (as shown below) will, in most cases, ensure sufficient air space around the downlighter to prevent overheating. typical insulation support box Loft cover Manufacturer s instructions In all cases, the manufacturer s instructions supplied with the downlighter must be followed. The manufacturer should specify, amongst other things, the amount of space to be left around the back of the downlighter, its fire rating, whether the fitting can be covered with thermal insulation, and the type/wattage of lamps that can be fitted. ingress protection (ip) rating Downlighters should be selected with the correct IP rating for the location in which they are to be installed. For example, those located in bathrooms should have an IP rating based on the zone they are installed in. In all cases, account must be taken of the requirements given in the current version of BS 7671 (Requirements for Electrical Installations, IEE Wiring Regulations 17th Edition), the national standard for the safety of electrical installations.

4. Downlighter lamps explained The most widely available types of tungsten halogen lamp are manufactured with either a dichroiccoated (cool beam) reflector or an aluminium reflector. The reflector type determines the way in which most of the heat generated by the lamp is reflected. reflector types Dichroic (cool beam) lamps reflect visible light forwards while allowing most of the radiated heat to pass out of the back of the lamp WArninG: these lamps must only be used in downlighters specifically designed for their use, otherwise overheating can occur. Aluminium lamps reflect the visible light and most of the heat forwards out of the front of the lamp. However, consideration must be given to the positioning and intended use of downlighters fitted with aluminium reflector lamps to prevent excessive heating of lighted objects. Lamp bases The most common tungsten halogen lamps for use in downlighters are push fit (GU4 or GU5.3) for ELV, or twist and lock (GU10 or GZ10) for mains voltage types. elv lamp bases Mains voltage lamp bases 4 mm 5.3 mm GU4 GU5.3 GU10 10 mm GZ10 10 mm Although lamp bases are different in design to prevent ELV lamps being used in mains voltage fittings, GU4, GU5.3 and GZ10 lampholders will accept both aluminium and dichroic reflector lamps. the use of dichroic reflector lamps in downlighters designed for use with aluminium reflector lamps only could create excessive heat within the luminaire leading to an unsafe situation and risk of fire. Downlighters marked with this warning symbol Must not be fitted with dichroic reflector lamps. COOL BEAM

Glass shield of self-shielded lamp Protective shield Tungsten halogen lamps must be fitted with a protective shield (a glass plate in front of the halogen filament) to ensure that particles from a shattered lamp cannot cause harm. Downlighter fittings not supplied with a glass protective shield must be fitted with a selfshielded lamp. 5. Safety symbols, information and markings The relevant product standards relating to luminaires and associated control equipment specify safety information that manufacturers must mark on downlighters, lamps and associated transformers, or their packaging. A recent revision of the product standard relating to luminaires (BS EN 60958-1) has resulted in some symbols and markings having been changed to align with current international (IEC) standards. All the provisions of the revised 2008 edition of BS EN 60958-1 are required to be implemented by April 2012. As a result of the transitional arrangements, downlighters may be sold and marked with both old and/or new symbols and information. The table opposite provides guidance on the new and old markings that may be found on downlighter products. 6. When fitting replacement lamps: Read and follow the manufacturer s instructions Check the packaging and the fitting for details of correct replacement lamps and do not exceed the rated wattage Always switch off the electricity before changing a lamp. Don t fit a dichroic reflector lamp unless the fitting is specifically designed for use with that type of lamp if in doubt, fit aluminium reflector lamps only If the downlighter is damaged, scorched or corroded, recommend a replacement. 7. Checking existing downlighters Check for visible markings on downlighters indicating lamp wattage and lamp type Check downlighters and their surroundings for signs of overheating such as curled labels and discolouration or scorching Ensure that downlighters installed in ceiling cavities have sufficient space around them Ensure that downlighters (and associated transformer where fitted) are not in contact with or covered by loft insulation or other combustible material, unless they are designed to operate safely in those conditions.

2004 edition of 60958-1 2008 edition of 60598-1 and other related standards and other related standards rated wattage (W) and voltage (V) Warning against the use of cool beam (dichroic reflector) lamps As indicated on the downlighter, lamp or transformer COOL BEAM Protective shields incorporated in downlighters that need to be replaced if damaged Minimum distance from lighted objects (to prevent fire risks) Rated maximum ambient temperature Downlighter designed to be used only with self-shielded tungsten halogen lamps (The majority of halogen lamps have a protective shield that also blocks UV (ultraviolet) radiation. Lamps must be operated only in a downlighter supplied with a protective shield Downlighters not suitable for direct mounting on normally flammable surfaces Downlighter suitable for direct mounting on normally flammable surfaces Not specified Downlighter not suitable for covering with thermal insulating material Not specified Downlighter suitable for covering with thermal insulating material Not specified Lamp (or transformer) is not suitable for use with a dimmer switch. Thermally protected transformer

Check that downlighters are not installed too close to furniture, curtains or similar combustible items If dichroic (cool beam) lamps have been fitted in downlighters designed for use with aluminium reflector lamps only, replace them with the correct type - look for the symbol indicating no use of cool beam lamps: COOL BEAM 8. Alternatives to tungsten halogen lamps Consider fitting low energy lamps, such as CFL (compact fluorescent), or LED lamps, as they produce less heat than traditional tungsten halogen lamps and so reduce the risk of fire. They also use less electricity. 9. Safe disposal of lamps Some downlighter lamps, such as energy efficient compact fluorescent lamps displaying the crossed-out wheelie bin symbol, must not be disposed of in general household waste. Take the lamps to a recycling facility that accepts electrical products. Check with your Local Authority for your nearest recycling centre. Need Help? For further information on downlighter safety, please visit: www.esc.org.uk or call 0870 040 0561 Acknowledgements Surrey Fire and Rescue Service The Lighting Association CE Compliance Solutions Tenmat Ltd Click Scolemore International Ltd. www.direct.gov.uk/firekills The Electrical Safety Council Unit 1.10, Canterbury Court, 1-3 Brixton Road, London, SW9 6DE Phone: 0870 040 0561 Fax: 0870 040 0560 Email: enquiries@esc.org.uk Web: www.esc.org.uk Registered Charity No. 257376 The Electrical Safety is an independent charity committed to reducing deaths and injuries caused by electrical accidents at home and at work.