b!klimax radiant wall/ceiling system

Similar documents
We have been working in an ideal climate for thirty years.

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Lesson 36 Selection Of Air Conditioning Systems

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Energy Efficiency HOSPITALITY.

CRAC Precision climate control units for data centres

KONRAD. Hybrid Fancoil Series

HDA

stainless steel pre-assembled manifolds

Glossary of Heating, Ventilation and Air Conditioning Terms

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Split units TH with hermetic compressors

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Refrigeration Air Dryers. Catalogue

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

HEATING AND COOLING UNDERFLOOR SYSTEM

Energy Efficiency. Bars & RestauRants.

ECOCIAT. Domestic hot water heat recovery unit

saving energy in comfort Factsheet Recair Enthalpy

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Integrated Solar Radiant Systems

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

imagine SOLAR AIR CONDITIONING MADE EASY

HVAC Systems: Overview

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Deliverable A Design guidelines for Solar Cooling of buildings

Industrial infrared heater IR For premises with large volumes and high ceilings

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Delivering exceptional performance and Ecovalue. Ecocent

ECOplus Solar Cylinder

Mapei systems for radiating floor heating with high thermal efficiency

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Molds and mildew are fungi that grow

Under sill units. Type FSL-B-ZAS

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

SustainE(Sustainable Energy)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Federation of European Heating, Ventilation and Air-conditioning Associations

HVAC Processes. Lecture 7

HERZ-Thermal Actuators

Modular Access Floor for Data Center. From Rack to Row to Room to Building

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Innovent LASER Packaged Fresh Air Conditioning Units

UDSA - UDSBD unit heater

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Refrigerated Air Dryers. Catalogue

3/29/2012 INTRODUCTION HVAC BASICS

Failure code manual. content

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Dehumidifier D 850E. - Instruction manual version 02

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

How To Make A Building Energy Efficient

ELECTRIC CENTRAL HEATING FLOW BOILER

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Cooking at the Speed of light!

Life cycle cost comparison of TAB vs. other HVAC (UK) TECHNICAL BROCHURE

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

RPV - RP - RA air handling units

Chapter 3.4: HVAC & Refrigeration System

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Cool Design for Homes and Offices

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Rotary Screw Compressor. MSM MINI 2, ,5 kw

CORNER FRIDGE THERMOLUX TL6 - TL10 - TL16 INSTALLATION AND OPERATION INSTRUCTIONS

Bring the fresh in. Dedicated Outside Air Systems

Brochure EX

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Direct steam injection humidifiers

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

type UTA Technical information manual

2014 British Columbia Building Code Changes


DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

ENHANCED LABORATORY HVAC SYSTEM

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

How To Control Humidity With A Humidifier

Instructions for designing heating systems.

HEATING, VENTILATION & AIR CONDITIONING

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Daikin Altherma hybrid heat pump. The natural combination

Combi Unit Genius. The energy efficient Building Service Centre

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Heating and cooling. Insulation. Quick facts on insulation:

Transcription:

b!klimax radiant wall/ceiling system

We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the first company to receive the management system quality certification (today UNI EN ISO 9001:2008). RDZ has been a quality-oriented company since its very beginning, using the finest materials, developing new solutions, constantly providing excellent service. And also by creating a positive climate in the company to promote the exchange of ideas and stimulate cooperation for constant improvement.

b!klimax radiant heating system for wall or ceiling installation. Built to fit your wellbeing. b!klimax is an integrated radiant heating and cooling system that can be installed on walls or ceilings. Developed by RDZ through continuous technological research on heating and cooling for all seasons, b!klimax is simple, functional and... revolutionary. b!klimax is an innovative system that exploits the ability of large surfaces (ceilings and walls) to exchange heat with the environment by radiation. Thanks to b!klimax the human body can perfectly balance its heat exchanges, increasing the level of perceived comfort. 1

2 Wall and ceiling heating and cooling

Invisible comfort in every season. Innovative and versatile, b!klimax is a radiant heating and cooling system for wall or ceiling installation. It is the ideal solution in rooms where it is important to maintain comfortable conditions all year round. Its very low thermal inertia and high efficiency make b!klimax the ideal system for houses, renovated buildings and commercial applications. Completely concealed in ceilings or walls, b!klimax makes it possible to use all the available space while improving the appearance of the room. 3

Wall and ceiling heating and cooling Comfort without draughts. With b!klimax there will be no more of those cold draughts caused by traditional air conditioning systems. 4

The Reasons for Choosing b!klimax. b!klimax means comfort. The uniform distribution of heat and cold emitted by the walls and the ceiling through radiation guarantees a homogeneous temperature inside the room, without annoying cold air draughts. b!klimax is a low-temperature system that saves you money on operating costs and can be used with eco-friendly, alternative energy sources. The absence of any convective movements caused by temperature differences between the heating body and the environment means that no dust or impurities are blown into the air, thus improving hygiene. 1 2 3 4 5 6 7 Ideal for summer and winter. Lower energy consumption. High thermal output. Low thermal inertia. Greater aesthetic freedom. More respect for nature. Better hygiene, better health. 5

Radiant Panels are the Heart of b!klimax. Radiant panels are light, easy to handle and simple to install. They are reliable, they prevent thermal bridges and guarantee full freedom to choose any form of wall covering or decoration. 6

Wall and ceiling heating and cooling 7

Wall and ceiling heating and cooling Circuit printed on panel surface Gypsum plaster slab Fibreglass mesh Ø 6 mm polybutylene pipe with anti-oxygen barrier embedded in gypsum plaster slab Polystyrene panel, thickness 40 mm Rebate 8

b!klimax: Radiant Panels. b!klimax panels can be mounted on walls or on the ceiling. They are made of moulded polystyrene with a density of 30 Kg/m 3 and a thickness of 40 mm. The panels are provided on all four edges with a 27 mm rebate to prevent thermal bridges with the bearing structure. The panels are designed to accommodate Ø 6 mm PB pipes with anti-oxygen barrier conforming to DIN 4726. The panel and the pipes are covered by a layer of fibrous plaster to increase their thermal output. Dimensions Radiant panel 600 code 6100595 > Dimensions: 600x600x40 mm > Density: 30 Kg/m 3 > Weight: 2.8 Kg > Ø 6x1 mm PB pipe with anti-oxigen barrier > 1/2 basic circuit (8 m) > Radiating surface 0.36 m 2 Radiant panel 1200 code 6101200 > Dimensions: 1200x600x40 mm > Density: 30 Kg/m 3 > Weight: 5.5 Kg > Ø 6x1 mm PB pipe with anti-oxigen barrier > 1 basic circuit (15 m) > Radiating surface 0.72 m 2 Radiant panel 2200 code 6102200 > Dimensions: 2200x600x40 mm > Density: 30 Kg/m 3 > Weight: 10.5 Kg > Ø 6x1 mm PB pipe with anti-oxigen barrier > 2 basic circuits (14 m each) > Radiating surface 1.32 m 2 9

Wall and ceiling heating and cooling Example of distribution to radiant squares 600x600 Radiant square 4-way distributors with anticondensation insulation Ø 20 mm pre-insulated red/blue pipe Ø 6 mm pre-insulated pipe Fittings with anticondensation insulation 10

b!klimax: Radiant Squares 600x600. b!klimax radiant squares can be installed on metal ceilings with 600x600 mm ceiling sections. They are made of moulded polystyrene with a density of 30 kg/m 3 and a thickness of 40 mm. The panels are designed to accommodate Ø 6 mm PB pipes with anti-oxygen barrier conforming to DIN 4726. The panel and the pipes are covered by a layer of fi brous plaster to increase their thermal output and have a double-sided adhesive coating for attaching to the metal ceiling sections. Dimensions Radiant square for metal ceilings code 6100593 > Dimensions: 593x593x40 mm > Density: 30 Kg/m 3 > Weight: 2.8 Kg > Ø 6x1 mm PB pipe with anti-oxigen barrier > 1/2 basic circuit (8 m) > Radiating surface 0.36 m 2 Radiant square with smooth-edge metal ceiling section 10 code 6100200 > Dimensions: 600x600x40 mm > Basic metal panel 15 lowered by 8 mm, square angle > Ø 6x1 mm PB pipe with anti-oxigen barrier > 1/2 basic circuit (8 m) > Radiating surface 0.36 m 2 Radiant square with smooth-edge metal ceiling section 90 code 6100100 > Dimensions: 600x600x40 mm > Basic metal panel 15 lowered by 8 mm, square angle > Ø 6x1 mm PB pipe with anti-oxigen barrier > 1/2 basic circuit (8 m) > Radiating surface 0.36 m 2 Ø 6 mm pre-insulated pipe Double-sided adhesive Fibre-reinforced layer Ø 6 mm push-fi t pipe fi ttings 11

Wall and ceiling heating and cooling Example of distribution to radiant squares 1200x600 Radiant square 4-way distributors with anticondensation insulation Ø 20 mm pre-insulated red/blue pipe Ø 6 mm pre-insulated pipe Fittings with anticondensation insulation 12

b!klimax: Radiant Squares 1200x600. For the installation into metal false ceilings, RDZ new radiant panels 1200 mm x 600 mm, ideal for their practical assembly, their easy hydraulic connection and their aesthetics, complete the range of RDZ square panels 600x600 mm. These panels 1200x600 are made of moulded polystyrene with a density of 30 kg/m 3 and a thickness of 40 mm, and they are designed to accommodate Ø 6 mm PB pipes with anti-oxygen barrier conforming to DIN 4726. Panels and the pipes are covered by a layer of fi brous plaster to increase their thermal output and have a double-sided adhesive coating for attaching to the metal ceiling sections. Dimensions Radiant square for metal ceilings code 6101203 > Dimensions: 1190x593x40 mm > Density: 30 Kg/m 3 > Weight: 6.44 Kg > Ø 6x1 mm PB pipe with anti-oxigen barrier > N 1 basic circuit (13.2 m) > Radiating surface (0.72 m 2 ) Radiant square with smooth-edge metal ceiling section 20 code 6100400 > Dimensions: 1200x600x40 mm > Basic metal panel 24 lowered by 15 mm square angle > Tubazione in PB BAO Ø 6x1 mm > N 1 basic circuit (13.2 m) > Radiating surface (0.72 m 2 ) 13

Wall and ceiling heating and cooling b!klimax: Thermal Output. Radiant Wall System. Thermal output of heating wall Specific power (W/m 2 ) Twater - Troom(K) Example: how to read the Wall heating chart. Assuming an average water temperature of 45 C and a room temperature of 20 C. Twater - Troom = 25 K. Since the panels are covered by plasterboard, the specific power will be 140 W/m 2 and the surface temperature 20 + 15.5 = 35 C. plaster plaster + tiles plasterboard Thermal output of wall cooling Specific power (W/m 2 ) Troom - Tsurface (K) Tsurface Troom (K) 14 Troom- Twater (K)

b!klimax: Thermal Output. Radiant Ceiling System. Thermal output of heating ceiling As you can see, ceiling b!klimax system shows particularly high values of specific power during summer cooling. Depending on the type of surface finish, the values range from 70 to 100 W/m 2. Thermal output of ceiling cooling Specific power (W/m 2 ) Specific power (W/m 2 ) Tsurface Troom (K) Twater - Troom(K) plaster plaster + tiles plasterboard Troom - Tsurface (K) Troom - Twater (K) 15

Wall and ceiling heating and cooling b!klimax system and RNW 1000 and RTK 1000 Ø 20 mm pre-insulated pipes Distribution with insulation shell Radiant squares Metal structure for metal false ceiling and b!klimax radiant squares 16

its components Delivery channel Metal structure for false ceiling and b!klimax panels Room temperature and humidity sensor User interface Maxi manifold Radiant panels 2200x600 Return channel 17

18 Wall and ceiling heating and cooling

b!klimax: Maxi Manifolds. Using suitable temperature control systems (and buffer tanks, if necessary), the water is sent from the heat generator (boiler or chiller) to the main manifolds (called Maxi manifolds) and from there to the radiant panels, passing through secondary manifolds called distributors. Special deaerators (air traps) are installed upstream from the Maxi manifolds to keep the system fully efficient at all times. 1 Maxi manifolds Code 6302002-010 Made of plastic material, Ø 1 1/4, modular assembly, ideal for high flow-rate, equipped with shut-off valves, which can be provided with electrothermal heads controlled by a thermostat, air vent and discharge valves, thermometers on delivery and return flow, brackets, Y filter and fittings for Ø 20 mm pipes. Anti-condensation shells are supplied as standard. 2 3 Electrothermal head Code 6301010 Electrothermal heads to control each circuit through a room thermostat. Protection degree IP 44. It is possible to place the electrothermal head upsidedown. Voltage: 230 V. Electrothermal head with micro switch Code 6301020 Electrothermal heads to control each circuit through a room thermostat, provided with limit micro switch. Protection degree IP 44. It is possible to place the electrothermal head upsidedown. Voltage: 230 V and 24 V. 19

20 Wall and ceiling heating and cooling

b!klimax: Distributors. The distributors are an important part of the system. The Maxi manifold is connected to the distributors by pre-insulated Ø 20x2 mm polybutylene pipes, while the distributors are connected to the panels by pre-insulated Ø 6x1 mm polybutylene pipes. 1 Pair of 8-way closed distributors Code 6210050 Pair of manifolds made of plastic material, designed to facilitate the connection of b!klimax panel pipes. The distributors are equipped with anticondensation shells and push-fit pipe fittings for the Ø 6 mm and Ø 20 mm pipes. 2 Pair of 8-way open distributors Code 6210040 Pair of manifolds made of plastic material, designed to facilitate the connection of b!klimax panel pipes. The distributors are equipped with anticondensation shells and push-fit pipe fittings for the Ø 6 mm and Ø 20 mm pipes. 3 Pair of 4-way closed distributors Code 6210060 Pair of manifolds made of plastic material, designed to facilitate the connection of b!klimax panel pipes. The distributors are equipped with anticondensation shells and push-fit pipe fittings for Ø 6 mm and Ø 20 mm pipes. 4 Pair of 4-way open distributors Code 6210070 Pair of manifolds made of plastic material, designed to facilitate the connection of b!klimax panel pipes. The distributors are equipped with anticondensation shells and push-fit pipe fittings for Ø 6 mm and Ø 20 mm pipes. 1 2 3 4 21

Wall and ceiling heating and cooling b!klimax: Hydraulic Characteristics of Ø 6x1 mm PB Pipes. Pressure loss in Ø 6x1 mm pipe Pressure loss (DaPa/m) water speed (m/s) Ø 6 mm PB pipe Code 6320006 Ø 6 mm PB pipe with antioxygen barrier conforming to DIN 4726 EN12319-2. Example: Assuming that a basic circuit (Ø 6 mm, length 15 mm) has a flow rate of 20 kg/h, the pressure loss is approximately 116 DaPa/m, and the total loss is 116 x 15 = 1740 DaPa. Flow rate (kg/h) 22

b!klimax: Hydraulic Characteristics of Ø 20x2 mm PB Pipes. Pressure loss in Ø 20x2 mm pipe Pressure loss (DaPa/m) water speed (m/s) Ø 20 mm PB pipe Code red 6300620, Code blue 6310620 Ø 20 mm PB pipe with anti-oxygen barrier conforming to DIN 4726 EN 12319-2 and insulating sheath. It is used to connect the distributors to the Maxi manifolds. Example: By connecting 20 basic circuits through the Ø 20 mm pipe using the distributors, the water flow rate is 20 kg/h x 20 circ. = 400 kg/h. The chart shows a pressure loss of 28 DaPa/m and, considering a pipe 20 m long, the result is 28 x 20 = 560 DaPa. Flow rate (kg/h) 400 23

b!klimax: The Complete Solution. b!klimax is more than radiant panels it is an integrated system complete with temperature controls and air-handling equipment that lets you optimize water temperature, room temperature and air humidity. 1b!klimax radiant panels With their large heat-exchange surface, b!klimax high-efficiency radiant panels regulate the thermal energy in every room, bringing heat or cold according to the season. 24

Wall and ceiling heating and cooling 2 RNW dehumidifiers RNW dehumidifiers and the air treatment units keep humidity under control and make it possible to avoid condensation. 3 RC and EVO-SA temperature controls RC and EVO-SA temperature controls, equipped with expandable control units and temperature and humidity sensors, provide full control over the system to keep it at maximum efficiency. 25

Expandable RC and EVO-SA controls. User interface They are complete, expandable systems to control radiant heating and cooling installations. They are built with a limited number of components and designed for flexibility of operation. They can control small installations or large multi-zone plants and centralized energy plants, providing temperature control for every single user. Zone expansion units 26

Wall and ceiling heating and cooling Central unit Room temperature/humidity sensor External sensor Connectors Serial card Clock card Delivery sensor 27

RNW Dehumidifiers and Heat Recovery Units. Dehumidifiers to control relative humidity in radiant heating/cooling systems. Each machine is a cooling unit equipped with 2 additional heat exchangers that exploit the availability of chilled water (15-18 C) used by the radiant panels. The pre-treatment coil, located under the evaporator, reduces the temperature of the air, lessening the sensible load on the evaporating coil. The post-treatment coil, located after the condenser, reduces the temperature of the air before sending it back to the room. This treatment produces dehumidified air with the same temperature as the air inside the room. Basically, RNW dehumidifiers control the latent load ; this increases the efficiency of the cooling unit, which supplies the panels with water at higher temperatures than the temperature usually required for dehumidifying. RNW 204 I Wall/embedded dehumidifi er - Code 7040010 Power consumption Watt 340 Air flow m³/h 200 15 C Water flow L/h 240 Dimensions (lxhxd) mm 760x619x207 Weight kg 45 Dehumidification capacity* L/24h 24.0 For houses (areas up to...) m 2 80-100 RNW 204 E External/wall dehumidifi er - Code 7040028 Power consumption Watt 340 Air flow m 3 /h 200 15 C Water flow L/h 240 Dimensions (lxhxd) mm 800x650x230 Weight kg 49.6 Dehumidification capacity* L/24h 24.0 For houses (areas up to...) m 2 80-100 RNW 404 CS Ceiling/embedded dehumidifi er - Code 7040030 Power consumption Watt 360 Air flow m³/h 220 15 C Water flow L/h 240 Dimensions (lxhxd) mm 711x242x546 Weight kg 36 Dehumidification capacity* L/24h 26.6 For houses (areas up to...) m 2 100-130 28

Wall and ceiling heating and cooling RNW 508 CS Ceiling/embedded duct dehumidifi er - Code 7040050 Power consumption Watt 500 Air flow m³/h 500 Dehumidification capacity* L/24h 42 Dimensions (lxhxd) mm 840x290x600 Weight kg 47 Available static pressure (average speed) Pa 52 For houses (areas up to...) m 2 150-200 RNW 600 CS Ceiling/embedded duct dehumidifi er - Code 7040035 Power consumption Watt 900 Air flow m³/h 600 Dehumidification capacity* L/24h 62 Dimensioni (lxhxd) mm 690x349x718 Weight kg 53 For houses and offices (areas larger than...) m 2 280 RNW 1000 Duct dehumidifi er - Code 7030040 Power supply V/ph/Hz 230/1~ +N/50 Dehumidification capacity* L/24h 50.2 Rated power consumption Watt 950 Air flow m³/s 0.278 m³/h 1000 Refrigerant type and quantity R407C kg 1.2 Sound pressure level** db[a] 53 Available static pressure of fan Pa 100 Dimensions (lxhxd) mm 875x398x761 Weight Kg 73 For commercial applications RTK 1000 Heat recovery unit - Code 7030050 Power supply V/ph/Hz 230/1~ +N/50 Rated power consumption Watt 150 Air flow m³/s 0.278 m³/h 1000 Available static pressure of fan Pa 100 Dimensions (lxhxd) mm 875x398x980 Weight Kg 47 For commercial applications * Measured at 26 C room temp, 65% HR and 15 C inlet water temp. - ** At 1 m in free-field atmosphere. 29

Wall and ceiling heating and cooling b!klimax reference projects. Offices House Heating b!klimax and heating cooling and with cooling b!klimax radiant system. radiant squares. 30

b!klimax reference projects. Showroom and offices Heating and cooling with b!klimax ceiling units. 31

b!klimax reference projects. Officies b!klimax heating and cooling system with square panels 600x600. RDZ S.p.A. Viale Trento, 101 (S.S. 13 Km 64,5) - 33077 Sacile, PN - ITALY Tel. +039 0434.787511 - Fax +39 0434.787522 www.rdz.it - rdzcentrale@rdz.it

Cod. 9128300.01-12/2009