B. System design, installation, and certification. B. Division 26 - Fire alarm systems and wiring connections.

Similar documents
SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Sprinkler Guards Model C Model D

RMF Engineering

SECTION PIPE HANGERS AND SUPPORTS

Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

SECTION COMMERCIAL PLUMBING FIXTURES

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

Model KFR56 Series Quick Response Standard Spray

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Viking Residential Sprinkler Installation Guide

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

TECHNICAL DATA. Dry 122a. November 12, 2013

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

FIVE YEAR CERTIFICATION REPORT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

Clark County Fire Prevention

Model/Sprinkler Identification Numbers

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

Sprinkler Identification Numbers

Quick response concealed horizontal sidewall sprinkler

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Technical Data. Installation

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Model F1FR Series Quick Response Glass Bulb Sprinklers

Engineering Specifications

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

C I T Y O F S E L M A F I R E D E P A R T M E N T

esfr pendent sprinkler vk510 (k25.2)

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Automatic Fire Sprinkler Submittal Requirements

KODAK VERSAMARK, INC.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION GROUND WATER STORAGE TANKS

BUILD FOR QUALITY BUILD FOR VALUE BUILD FOR LIFE

SECTION FACILITY STORM DRAINAGE PIPING

Price Book - Section 20 Miscellaneous

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Viking Residential Sprinkler Installation Guide

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

General Fire Code Requirements Within Commercial Tenant Spaces

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

PRESSURE REDUCING CONTROL VALVE

Extended Coverage Sprinklers

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

FIRESTOPPING & SMOKE SEALS

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS

SECTION DIESEL-DRIVEN, FIRE PUMPS

SECTION FIRE PROTECTION PIPING SYSTEMS STANDARD CONSTRUCTION STANDARD PART 1: GENERAL

SECTION FIRE HYDRANTS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Electrical Wiring Technical Bulletin

SECTION 807 PUMP STATION REHABILITATION

SECTION SOIL AND WASTE SYSTEMS

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

BERMAD Fire Protection

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Transformer Deluge Systems

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

FIRING RANGE PHASE 1 DESIGN

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

SECTION DUCTILE IRON PIPE AND FITTINGS

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

I-768 FireLock NXT Dry Valve

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

We look forward to working with you. Worldwide Headquarters 1400 Pennbrook Parkway Lansdale, PA

BERMAD Fire Protection

2010 Residential Water Heater Replacement Check List

SECTION WINDOW WASHING SYSTEMS

Sprinkler Identification Numbers (SINs) Technical Data

Commercial Fire Inspections

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

Fire detection, alarm, and suppression systems are installed to:

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Wastewater Capital Projects Management Standard Construction Specification

Transcription:

SECTION 211000 - PART 1 GENERAL 1.1 SECTION INCLUDES A. Modifications to existing partial coverage wet-pipe sprinkler system to suit architectural renovations. Work generally to include relocation of heads to suit revised floor plan. B. System design, installation, and certification. 1.2 RELATED SECTIONS A. Division 9- Painting. B. Division 26 - Fire alarm systems and wiring connections. 1.3 REFERENCES A. ASTM 135 - Electric-Resistance-Welded Steel Pipe. B. NCSBC - North Carolina State Building Code. C. NFPA 13 - Installation of Sprinkler Systems. D. NFPA 70 - National Electrical Code. E. NFPA 101 - Life Safety Code. F. UL - Fire Resistance Directory. G. UL 199 - Automatic Sprinklers. 1.4 SCOPE OF WORK A. Hydraulic design of sprinkler system. B. Shop drawings. C. Flow switches, valves and accessories. D. Interior pipe, fittings, and valves. E. Hangers, supports and sleeves. F. Sprinkler heads and extra sprinkler cabinet. G. Testing and flushing. Wayfinding, Visitor Center, and Museum Improvements 211000-1

1.5 DESIGN REQUIREMENTS A. Design modifications to existing partial coverage wet pipe sprinkler system as required to suit building renovations. Design shall comply with Owner's insuring agency guidelines, NFPA 13, NCSBC and local jurisdiction code requirements. Document existing sprinkler systems in field. Existing sprinkler piping may be reused to extent compatible with renovations. Coordinate layout with new architectural, plumbing, mechanical, and electrical work. B. Base design on the following criteria: 1. Hazard occupancy and water supply requirements are not changed from current use. Verify existing design criteria. 2. Utilize existing mains, alarm valves, etc. to extent practical. 3. Interface new sprinkler piping with existing building sprinkler piping. 4. Existing sprinkler interface with building fire and smoke alarm system is to remain. Provide extensions or modifications if required by renovation work. 1.6 SPRINKLER WORK IN CONNECTION WITH ELECTRICAL CONTRACT A. Minimal modifications to electrical work associated with existing sprinkler systems are anticipated. Sprinkler Contractor shall be responsible for any electrical work Coordinate interface requirements with Electrical Contractor. B. All electrical work performed under the Sprinkler Contract shall comply with Division 23. All wiring shall be installed in conduit. 1.7 SUBMITTALS FOR REVIEW A. Procedures for submittals: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections B. Product Data: Provide manufacturers catalog data on sprinklers, valves, water flow and tamper switches, and specialties. Include performance ratings, rough-in details, weights, support requirements, and piping connections. C. Shop Drawings: 1. Indicate hydraulic calculations, detailed pipe layout, hangers and supports, sprinklers, components and accessories. Indicate system controls. 2. Submit drawings and calculations to State Construction Office (SCO), Local Fire Marshal and Owner's Insuring Agent for approval. After receiving approval from SCO, Local Fire Marshal and Owner's Insuring Agent, submit shop drawings and calculations for review prior to start of installation. Include SCO, Local Fire Marshal's and Owner's Insuring Agent approval stamp on submitted shop drawings. Wayfinding, Visitor Center, and Museum Improvements 211000-2

1.8 SUBMITTALS AT PROJECT CLOSEOUT A. Procedures for submittals: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections B. Project Record Documents: Record actual locations of sprinklers and deviations of piping from drawings. Indicate drain and test locations. C. Contractor's Certificate: Certify that system has been tested and meets or exceeds specified requirements and code requirements. D. Operation and Maintenance Data: Include components of system, servicing requirements, record drawings, inspection data, replacement part numbers and availability, and location and numbers of service depot. E. Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. 1.9 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing the Products specified in this section with minimum three years experience. B. Installer Qualifications: Owner approved, local and state licensed fire protection company specializing in performing the work of this section with minimum three years experience. 1.10 REGULATORY REQUIREMENTS A. Perform Work in accordance with NFPA 13, NCSBC and local jurisdiction. Comply with SCO Fire Sprinkler Guidelines See website: http://www.ncsco.com/documents/guidelines/fire_sprinkler_guidelines_ March2012.pdf B. Equipment and Components: UL listed and FM approved. C. Products Requiring Electrical Connection: Listed and classified by testing firm acceptable to the authority having jurisdiction as suitable for the purpose specified and indicated. 1.11 DELIVERY, STORAGE, AND PROTECTION A. Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections B. Store products in shipping containers and maintain in place until installation. Provide temporary inlet and outlet caps. Maintain caps in place until installation. 1.12 EXTRA MATERIALS A. Provide extra sprinklers under provisions of NFPA 13. Wayfinding, Visitor Center, and Museum Improvements 211000-3

B. Provide suitable wrenches for each sprinkler type. C. Provide metal storage cabinet located adjacent to alarm valve or as otherwise directed. PART 2 PRODUCTS 2.1 VALVES A. Manufacturers: Nibco, Crane, Stockham, Grinnell, Mueller. B. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. C. Interior valves: 1. Swing check valves: Nibco No. F-908- W, UL, FM, bolted bonnet, horizontal swing, renewable seat and disc, 175 psi wwp. 2. Spring check valves: Nibco No. W-900-W, UL, FM wafer style, rubber seat, spring actuated, 250 psi wwp. 3. Gate valves: Nibco F-607-OTS, UL, FM, flanged pattern outside screen and yoke, 175 psi WP. 4. Butterfly valves: Nibco WD3510-8 or LD3510-8, UL, FM, wafer or lug style, 250 psi wwp, lug style 200 psi wwp dead end rated, internal tamper switch. 5. Ball valves: Nibco No. T -505-8 or 0-505-8, UL, FM, threaded or grooved, bronze body, three piece, internal tamper switches, 300 psi wwp. 2.2 PIPE AND FITTINGS A. Interior Sprinkler Piping: 1. Steel Pipe: ASTM 135, Schedule 40, electric-resistance welded. 2. Grooved Steel Piping: ASTM 135, Schedule 10, electric-resistance welded, suitable for roil grooving. B. Interior Sprinkler Pipe Fittings: 1. Manufacturers: Victaulic, Sprink, Grinnell. 2. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. 3. Mechanical couplings: Roll or cut groove rigid 4. Sprinkler fittings: NFPA 13, UL, FM, Class 125 or Class 250 cast iron, screwed, flanged, or grooved-end. 5. Provide all fittings by the same manufacturer. C. Drain Piping: 1. Steel Pipe: ASTM A106 or A120, Schedule 40, galvanized.. D. Drain Fittings: Class 250 maileable iron, screwed with galvanized coating. Wayfinding, Visitor Center, and Museum Improvements 211000-4

2.3 HANGERS AND SUPPORTS A. Manufacturers: Grinnell, Carpenter and Patterson, Fee and Mason. B. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. C. Clevis Hangers: NFPA 13, UL, FM 1. Grinnell #260 MSS, Type I for pipe 2 through 12 2. Grinnell Figure #104, Type 6, adjustable split ring for pipe less than 2. D. Clamps: NFPA 13, UL, FM 1. Riser Clamps: Grinnell #261, MSS Type 8, at floor slab penetrations to support risers. 2. C-Clamps: Grinnell #92 with retainer clip, MSS Type 23. 3. Nailable Beam Clamps: Grinnell Figure #218, MSS Type 30. E. Inserts: NFPA 13, UL, FM 1. Concrete insert: Grinnell Figure #281, MSS Type 18, universal concrete insert, adequately sized and correctly positioned to support full load. 2. Lightweight concrete: Grinnell #285. 3. Continuous Concrete Insert: Grinnell Powerstrut #PS-349, pregalvanized. 4. Power inserts shall not be used in post tension construction unless approved by Structural Engineer. 2.4 SLEEVES A. Sleeves for Pipes Through Non-fire Rated Beams, Walls, Footings, and Floors: Schedule 40 galvanized steel pipe. B. Sealant for Non-fire Rated Construction: Acrylic caulk. C. Sleeves for Pipes Through Fire Rated Construction : Schedule 40 galvanized steel pipe. Provide suitable listed penetration assembly. 2.5 SPRINKLERS A. Manufacturers: Gem, Central, Grinnell. B. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. C. General Requirements: UL Listed and FM approved except that full recessed type quick response sprinkler head may be UL listed only. Slip-type escutcheons not allowed. D. Brass Upright: Gem Model F980 designer, bulb type, ½ orifice, upright. Quick response Gem, Model FR-1, solder type, ½ orifice, upright. Wayfinding, Visitor Center, and Museum Improvements 211000-5

E. Chrome Pendent: Gem Model F980 designer, bulb type, ½ orifice, pendent. Quick response Gem, Model FR-1, solder type, ½ orifice, pendent. F. Horizontal Sidewall: Gem Model F950/Q-46, solder, ½ orifice. Quick response Gem, Model F A-I/Q-46, solder type, ½ orifice. G. Fully Recessed: Gem Model F946 cleanline, solder type, ½ orifice. Quick response Gem, model F975 bulb type, ½ orifice. H. Semi-recessed: Gem Model F948, solder type, ½ orifice Quick response Gem, model FA-IR, solder type, ½ orifice. I. Chrome Pendent Quick Response: Gem Model FR- 1, solder type, ½ orifice, pendent and upright. Provide quick response sprinkler head throughout smoke compartments containing patient sleeping rooms. J. Spare Sprinklers: Provide one sprinkler cabinet with 12 extra sprinkler heads and sprinkler wrench for emergency use. Locate cabinet in maintenance area. Provide a minimum of two extra sprinkler heads of each type sprinkler head used for the project. Add an extra sprinkler cabinet if necessary to house the spare heads. 2.6 SPECIALTIES A. Flow switch: 1. Manufacturers: Notifier, Potter, Simplex. 2. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. 3. Notifier Model No. WFD-6 vane type flow switch with pneumatic retard adjustable from 0 to 90 seconds, complete with double pole, double throw micro feature. B. Tamper switch: 1. Manufacturers: Notifier, Potter, Simplex. 2. Substitutions: Submit under provisions of relevant sections of the General and Supplemental General Conditions and Division 1 Specifications Sections. 3. Notifier Model No. SGV for 4 and larger, Potter Model No. OSYSU-A2 for pipe size less than 4, tamper switch double pole, double throw micro feature for 1/12-inch to 12-inch valves. PART 3 EXECUTION 3.1 DESIGN A. Comply with NFPA, NCSBC SCO and local jurisdiction. Provide complete system design for sprinkler system as indicated on the drawings and specified herein. B. Coordinate layout of sprinkler system with architectural, structural, plumbing, mechanical, and electrical work Wayfinding, Visitor Center, and Museum Improvements 211000-6

C. Design to utilize existing sprinkler system to extent appropriate to meet design requirements. 3.2 INSTALLATION A. Document existing conditions. B. Install in accordance with NFPA 13, NCSBC, SCO and local requirements. C. Arrange work to be in coordination with work of other trades. Remove/rework existing sprinkler systems as necessary. D. Remove any existing sprinkler piping, hangers, wiring, etc. rendered obsolete by new work. E. Existing sprinkler heads and device which remain as is may be reused. Install new sprinkler heads and devices where renovations are required. F. Arrange renovations so as not block access to existing valves, inspector s test connections, etc. G. Place pipe runs to minimize obstruction to other work. H. In areas with ceilings, place piping in concealed spaces above ceilings. I. Where lay-in ceilings are used, center sprinklers in two directions in ceiling tile and provide piping offsets as required. J. Install specified hangers in accordance with NFPA 13. Other NFPA 13 approved hangers are not allowed. Provide hangers on arm-outs of 12 or more. Support vertical risers 12' o.c. maximum or at each floor. For cloud ceilings, drop piping from existing ceiling above as required. Arrange drops so as to minimize visual effect from floor. K. Sleeve pipes passing through rated or non-rated partitions, walls and floors. Smokeproof all penetrations rated or non-rated per NCSBC. Provide suitable listed penetration assemblies for piping penetrating rated construction. L. Prepare exposed, unfinished pipe, fittings, supports, and accessories in finished areas ready for finish painting by General Contractor. Refer to Division 9. M. Apply masking tape or paper cover to ensure concealed sprinklers, cover plates, and sprinkler escutcheons do not receive field paint finish. Remove after painting. N. Flush piping system of foreign matter. O. Install guards on sprinklers where required. Wayfinding, Visitor Center, and Museum Improvements 211000-7

3.3 INTERFACE WITH OTHER PRODUCTS A. Ensure required devices are installed and connected as required to fire alarm system. 3.4 INSPECTION AND TESTING A. Obtain inspections as required by local jurisdiction. B. Provide system pressure test after modifications are complete. C. Provide system operational tests in accordance with NFPA 13 and local jurisdiction. D. Submit written test reports and certificates as required by NFPA 13 and local jurisdiction prior to request for Certificate of Occupancy. END OF SECTION Wayfinding, Visitor Center, and Museum Improvements 211000-8