ph METERS, HYDROLYSIS, AND BUFFER CAPACITY

Similar documents
ph: Measurement and Uses

Experiment 17: Potentiometric Titration

Acid Dissociation Constants and the Titration of a Weak Acid

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Experiment 6 Titration II Acid Dissociation Constant

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

Electrical Conductivity of Aqueous Solutions

Properties of Acids and Bases

Acid Base Titrations

Neutralizing an Acid and a Base

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

EXPERIMENT 4 Acid Strength

The Determination of Acid Content in Vinegar

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Chem101: General Chemistry Lecture 9 Acids and Bases

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

3 The Preparation of Buffers at Desired ph

Determining the Identity of an Unknown Weak Acid

ph Measurements of Common Substances

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Health Science Chemistry I CHEM-1180 Experiment No. 12 Acids, Bases, ph, Hydrolysis and Buffers (Revised 05/27/2015)

Chemistry 52. Reacts with active metals to produce hydrogen gas. Have a slippery, soapy feeling. React with carbonates to produce CO 2

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

Lab #10 How much Acetic Acid (%) is in Vinegar?

Experiment 7: Titration of an Antacid

CHAPTERS 15 FAKE TEST QUESTIONS. 1. According to the Brønsted Lowry definition, which species can function both as an acid and as a base?

Q.1 Classify the following according to Lewis theory and Brønsted-Lowry theory.

Name period Unit 9: acid/base equilibrium

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Q.1 Classify the following according to Lewis theory and Brønsted-Lowry theory.

Experiment 8 - Double Displacement Reactions

QUESTION (2012:3) (a) (i) Complete the table below showing the conjugate acids and bases. CO 3 H 2 O OH HCN CN -

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

AP FREE RESPONSE QUESTIONS ACIDS/BASES

UNIT (6) ACIDS AND BASES

EXPERIMENT 10: TITRATION AND STANDARDIZATION

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Chapter 17. The best buffer choice for ph 7 is NaH 2 PO 4 /Na 2 HPO 4. 19)

18 Conductometric Titration

Review for Solving ph Problems:

Acid-Base Titrations. Setup for a Typical Titration. Titration 1

CHM1 Review for Exam 12

POTENTIOMETRIC TITRATION OF A WEAK ACID

Chapter 17. How are acids different from bases? Acid Physical properties. Base. Explaining the difference in properties of acids and bases

CHM 130LL: ph, Buffers, and Indicators

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

Juice Titration. Background. Acid/Base Titration

Experiment 9: Acids and Bases Adapted from: Chemistry, Experimental Foundations, 4th Ed. Laboratory Manual, by Merrill, Parry & Bassow.

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Notes on Unit 4 Acids and Bases

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Titrations. Acid-Base Indicators and Titration Curves. Shapes of Titration Curves. A titration curve is a graphical history of a titration

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Note: (H 3 O + = hydronium ion = H + = proton) Example: HS - + H 2 O H 3 O + + S 2-

Solubility Product Constants

Acids and Bases: A Brief Review

The Determination of an Equilibrium Constant

FAJANS DETERMINATION OF CHLORIDE

Chemical equilibria Buffer solutions

Chapter 9 Lecture Notes: Acids, Bases and Equilibrium

A Potentiometric Analysis of Fluoride Ion in Toothpaste

EXPERIMENT 20: Determination of ph of Common Substances

Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1

Acids and Bases. An Introduction. David A Katz Department of Chemistry Pima Community College, Tucson, AZ, USA

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

Auto-ionization of Water

Copyright 2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved.

Experiment 3 Limiting Reactants

PERCENT ACETIC ACID IN VINEGAR EXPERIMENT 15

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Chapter 14 - Acids and Bases

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Chapter 10 Acid-Base titrations Problems 1, 2, 5, 7, 13, 16, 18, 21, 25

Acids, Bases, and ph

Experiment 16-Acids, Bases and ph

Neutralization Reactions. Evaluation copy

4.1 Stoichiometry. 3 Basic Steps. 4. Stoichiometry. Stoichiometry. Butane Lighter 2C 4 H O 2 10H 2 O + 8CO 2

Separation by Solvent Extraction

Determination of a Chemical Formula

Acid-Base Chemistry. Brønsted-Lowry Acids & Bases

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

Topic 18 Acids and Bases Exercises

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

CHAPTER 16: ACIDS AND BASES

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

stoichiometry = the numerical relationships between chemical amounts in a reaction.

Net ionic equation: 2I (aq) + 2H (aq) + H O (aq) I (s) + 2H O(l)

Determination of Citric Acid in Powdered Drink Mixes

Experiment 4 (Future - Lab needs an unknown)

An acid is a substance that produces H + (H 3 O + ) Ions in aqueous solution. A base is a substance that produces OH - ions in aqueous solution.

Acids and Bases HW PSI Chemistry

Upon completion of this lab, the student will be able to: H3O + (aq) + A (aq) BH + (aq) + OH (aq) O + ] [H 3. ph = log[h 3.

Transcription:

Experiment 9 ph METERS, HYDROLYSIS, AND BUFFER CAPACITY Prepared by Stephen E. Schullery and Ross S. Nord, Eastern Michigan University PURPOSE Learn to use a ph meter. Measure the ph of a variety of solutions, including observing the effect of hydrolysis. Determine the ph and buffer capacity of an unknown buffer solution. STRONG VERSUS WEAK ACIDS AND BASES A strong acid is commonly defined as one whose ionizable hydrogens dissociate completely in water to produce H + (or H3O + hydronium ions). By contrast, when a weak acid is dissolved in water, only a small fraction of the hydrogens dissociate. Parallel definitions in terms of hydroxide ion apply for strong and weak bases. The strengths of weak acids and bases range over a very broad continuum, from almost-strong to having negligible strength. S RENSEN'S ph SCALE In 1909 the Danish chemist S. P. L. Sørensen proposed a useful way to quantify the total amount of free H + as ph = log[h + ] or [H + ] = 10 ph (1) where the p is from the words Potenz, puissance and power literally, "hydrogen power." [H + ] indicates molarity of free hydrogen ions. The minus sign before the log results in ph usually being positive, because [H + ] is usually less than 1, and logarithms of such numbers are negative. Why is ph convenient? Given water's Kw = 1.0 x 10-14 (at 25 C), the range of hydrogen ion concentrations commonly encountered is from 1 to 10-14 M. The ph scale compresses this range of 14 orders of magnitude (involving negative exponents) into a simple, positive scale from 0 to 14. The ph of a neutral solution at 25 C falls in the middle of the scale, at ph 7.00. So, ph < 7.00 means acidic, and ph > 7.00 means basic. Scientists have embraced Sørensen's "p operator", and now use it as a general shorthand notation for the negative logarithm of anything. For example, pk = -log K and poh = -log [OH - ]. HOW CAN ph BE MEASURED? Because of the great sensitivity of many chemical reactions to [H + ], a convenient method of measuring ph is essential. A ph meter is just a voltmeter that draws very little current (high input impedance). What does voltage have to do with ph? The trick with this method is to take advantage of a special kind of glass which is permeable to H + ions but not to other ions. H + ions can diffuse from solution into this glass, but other ions can not follow. When a piece of this glass is used to separate two solutions of different [H + ], the high [H + ] side of the glass develops a slight positive charge as more H + 9-1

ions diffuse into that side than the other. The result is a measurable voltage difference across the two sides of the glass. Only the fragile bulb on the end of the electrode is made from the special ph-sensitive glass. Because the ph electrodes rely on electrical conduction through the test solution, the method doesn't work very well with nonaqueous solutions or even for aqueous solutions with very few ions in it (e.g., distilled water and rain water). The meter reading will either drift meaninglessly, or give a reading that is highly dependent on stirring rate and the ph of the previous solution in which it was used. Like any instrument, a ph meter must be calibrated using known, or standard, samples. Theoretically, a change of 1 ph unit causes a change of 59.2 mv in the measured voltage. In practice, this number can vary, particularly as the electrode ages. Thus, the voltage is measured at two different ph values and the equation of a line can then be extrapolated which gives the relationship between ph and voltage. Typically, standard buffer solutions with ph s of 4, 7, or 10 are used. Buffer solutions are used since their ph s aren t significantly affected by slight contamination or dilution. HYDROLYSIS WHY SOME SALT SOLUTIONS AREN'T NEUTRAL Many ions react with water to change its ph. Such a reaction is called hydrolysis meaning, "water splitting." For example, a cation RH + could react to make a solution acidic: RH + (aq) + H 2 O(l) R(aq) + H 3 O + (aq) (2) An anion A - could react to make a solution basic: A (aq) + H 2 O(l) HA(aq) + OH (aq) (3) You should study these reactions, and convince yourself that hydrolysis only happens if R is a weak base, or HA is a weak acid. NaCl doesn't change the ph of water because NaOH is a strong base and HCl is a strong acid. However, a NaF solution would be basic, because F - hydrolyzes water to form OH - and the weak acid HF. Similarly, a CH3NH3Cl solution would be acidic because the CH3NH3 + ion hydrolyzes water to form H3O + and the weak base CH3NH2. WHAT IS A BUFFER? A solution is said to be buffered or to be a buffer if its ph doesn't change much when either a strong acid or base is added. Clearly, a buffer must contain chemicals capable of neutralizing either an acid or base. That must mean a buffer contains both a base and an acid. How is this possible? Why don't the acid and base neutralize each other? The trick is to use a mixture of a weak acid (HA) and its conjugate weak base (A - ) which cannot neutralize each other. However, they will react nearly completely with any strong base or acid that is added. The weak acid will neutralize most of any strong base added, as follows: HA(aq) + OH (aq) A (aq) + H 2 O(l) (4) and the conjugate base will neutralize most of any strong acid that is added, as follows: H + (aq) + A (aq) H 2 O(l) (5) Notice that although the above reactions produce the base A - and the acid HA, they have effectively removed H + and OH - from the solution, and thereby preserved the ph. There are many important naturally occurring buffers. Our blood is buffered to hold around ph 7.4; if it weren't buffered, the increased acidity from lactic acid produced during exercise would be fatal. Unbuffered mountain lakes and streams are much more susceptible to acid rain than are the so-called limestone streams. WHAT IS BUFFER CAPACITY AND HOW IS IT MEASURED? Obviously if lots of acid or base were dumped into a buffer solution, the buffering ability could be overwhelmed. The ability of a buffer to resist ph change is referred to as its buffer capacity. Buffer capacity is defined as the moles of strong acid or base required to change the ph of 1 liter of the buffer by 1 ph unit (either higher or lower). It has units of moles/l. 9-2

The procedure for determining buffer capacity is simple: Measure the volume of standard acid or base needed to change a known volume of the buffer by exactly 1 ph unit. Calculate the moles of standard acid or base used. Divide this by the number of liters of buffer used to obtain the buffer capacity in units of moles/l. Sample Problem: Suppose you start with 10.0 ml of buffer to which 75 ml of water is added and the ph is read as 6.3. After the addition of 37.2 ml of 0.123M HCl from a buret, the ph has changed to 5.3. What is the buffer capacity? Solution: First, how many moles of standard acid were added? ( 37.2 ml of acid 1000 ml L ) (0.123 mol ) = 0.00458 mol L Next, divide by the liters of buffer used. In this example, only 10.0 ml of buffer were used. The 75 ml of water are irrelevant. This water was only added so that there would be sufficient solution present to immerse the ph electrode. 0.00458 mol 0.0100 L IN THIS EXPERIMENT = 0.458 mol/l You will learn how to calibrate a ph electrode, and then try to read the ph of tap and distilled water. You will prepare a series of HCl dilutions and see the effect of concentration on ph. The ph of equal concentrations of a strong acid and a weak acid will be compared. You will prepare three salt solutions, and measure the phs to test for hydrolysis. Finally, you will measure the buffer capacity of an unknown buffer solution. WARNING. THE FOLLOWING SECTION IS RATED PG-21. Teachers should consider whether they wish to allow their students under the age of 21 to read this section without professorial guidance. THE DARK SIDE OF THE FORCE There is a dark side to ph which is normally kept hidden from general chemistry students. The number reported by a ph meter does not exactly equal -log[h + ]. In fact, experimental ph values have no theoretically precise meaning. Some books will tell you that the problem is resolved by defining ph in terms of the H + activity, or effective concentration. Thus, Equation (6) is sometimes offered as an improvement over Equation (1). ph = log(h + activity) (6) According to the principles of thermodynamics, the activity of one kind of ion (e.g., H + ) is unknowable. So, Equation 6 can't be legitimate, at least as far as experimental measurement is concerned. This is because thermodynamics deals with properties of matter on a bulk scale, rather than a microscopic or molecular scale, and it is impossible to prepare a bulk sample of just one kind of ion. The counterions will always be present, and any measured property, including ph, will represent some sort of ill-defined average of that property for all ions in the solution. Thus, although a ph meter reading is certainly related to H + activity, it also depends in an indefinite way on the activities of everything else in the solution. The U.S. National Bureau of Standards has assigned ph values to certain buffer solutions, which everyone (in the U.S.) uses to "calibrate" their ph meters. So, at least we can all measure the same thing, even if no one is sure exactly what it means. Other countries' bureaus of standards have assigned slightly different values to some of these very same solutions! In practice, measured ph values correspond approximately to Equation (1), and we usually assume it is valid to the nearest 0.01 for ordinary solutions between about ph 3 and 10. The error increases at the extremes of the ph scale and at high salt concentrations. For example, a properly calibrated ph meter will record a ph of 1.10 for 0.10M HCl, rather than 1.00 as predicted by Equation (1). Similarly, 0.10M NaOH has a ph of 12.88, rather than the expected value of 13.00. 9-3

PRE-LABORATORY PREPARATION 1. Read the procedure and data analysis sections of the experiment. 2. Complete the computer-generated PRELAB assignment. Refer to the procedure and data analysis sections of the experiment as needed. The prelab questions for this experiment replicate the questions in the data analysis section. Additionally, they aid in the preparation of several necessary solutions. EXPERIMENTAL SECTION REAGENTS PROVIDED HCl, Hydrochloric acid, 0.10 M. HC 2H 3O 2, Acetic acid, 0.10 M. NaOH, Sodium hydroxide, roughly 0.05 M. NH 4Cl(s), Ammonium chloride, 53.49 g/mol. NaC 2H 3O 2(s), Sodium acetate, 82.03 g/mol. Na 2CO 3(s), Sodium carbonate, 105.99 g/mol. Unknown buffer solution. Hazardous Chemicals Handle the acid and base solutions with care. WASTE DISPOSAL All of the chemicals used in this experiment may be safely disposed of by washing down the sink. PROCEDURE Ordinarily, you will do this experiment with a partner (or two, if necessary). Each student will do his/her own buffer capacity determination. LEARNING TO MAKE ph MEASUREMENTS It is easy to get poor results when making ph measurements. This is almost always due to contaminated solutions. TO AVOID CONTAMINATION: (1) BE SURE TO RINSE THE ph ELECTRODE THOROUGHLY BEFORE PLACING IT IN ANY SOLUTION! (2) WASH AND RINSE YOUR GLASSWARE BEFORE USING IT! 1. Setup and do a two-buffer calibration of your ph electrode following the directions in the Techniques section (located after the procedure section). In this experiment we are primarily measuring the ph of acidic solutions, so we will use ph 4 and 7 buffers to calibrate the ph electrodes. Leave the buffer solutions in the glass bottles and do NOT pour them into other beakers. Avoid leaving the ph electrode out of solution for long periods. It is best to keep the electrode in a beaker of distilled water between readings. 2. Read and record the ph of tap water. After placing the electrode in a new solution, swirl it for a few seconds to homogenize the solution near the electrode. Record all ph readings to the nearest 0.01 ph unit. If the reading fluctuates randomly, wait a few seconds and record the average reading. If the readings are drifting in one direction, wait a minute or two until the reading stabilizes. A slow drift usually indicates that either (1) there are few ions present and the meter is having trouble getting an accurate reading; (2) gas is being adsorbed from the air (if the solution is sufficiently dilute); or (3) a slight contaminant is diffusing through the solution. 9-4

3. Try to read the ph of distilled water. Record your observations. Do not spend all period staring at the ph meter while the reading slowly drifts. After a minute or two, take your reading and move on. ACID ph MEASUREMENTS 4. Read and record the ph of the 0.10 M HCl solution provided. 5. Prepare 0.010, 0.0010 and 0.00010 M HCl solutions using the stock solution of 0.10 M HCl provided. Read and record the ph of each of these solutions. Follow the plan described in your prelab for preparing these solutions. If you make 100 ml of each solution you will have plenty to prepare the next solution and measure the ph. Rinse pipets thoroughly before using them in a new solution: (1) run some distilled water through them; (2) wipe the outside dry; (3) rinse/fill the pipet with the new solution and then drain it completely. After these three steps, it should be ready to use to measure the new solution. 6. Read and record the ph of 0.10 M acetic acid solution provided. HYDROLYSIS STUDY 7. Prepare 100 ml of 0.10 M aqueous solutions of the salts ammonium chloride, sodium acetate, and sodium carbonate (see prelab calculations). 8. Read and record the ph of each solution. BUFFER CAPACITY DETERMINATION Each student should do this section individually. 9. Give the laboratory assistant a clean, dry 50 ml beaker for your unknown. You will be given approximately 25 ml of unknown. Record the unknown number. 10. Measure out 10.0 ml of your unknown buffer solution into a 250 ml beaker and add about 100 ml of distilled water. The 100 ml of water are added to ensure there is sufficient solution present to accurately read the ph. The water has no effect on the measured or calculated buffer capacity. 11. Read and record the ph of your buffer solution and the initial buret reading (to the nearest 0.01 ml). 12. With the ph electrode immersed in the (diluted) buffer solution, add standard NaOH from a buret until the ph has increased by 1.00 ph units. Record the actual concentration of the NaOH on your data sheet. The contents must be stirred during the addition. This can be done either by careful swirling of the beaker, or stirring with the ph electrode. Be careful not to hit the glass electrode on the sides of the beaker. The electrode should not be removed from the solution until the titration is complete. 13. Record the final ph and buret readings. CLEAN UP 14. Rinse the ph electrode, wipe it with a Kimwipe and return it to its storage bottle. Dump leftover solutions down the drain. Rinse, dry, and store your glassware. It is always a good idea to wash your hands at the end of lab. 9-5

TECHNIQUES CALIBRATION AND USE OF A ph PROBE 1. Start LOGGER PRO. Connect the ph electrode/amplifier to CH 1 on the interface box. 2. If Logger Pro does not automatically recognize the ph probe, set it up as follows: (a) Click on the interface box icon to open the LabPro interface window. (b) Select the ph probe from the scroll box of Analog Probes and then click and drag it into the box for CH 1. (Alternately, click on the white box for CH 1 and click on Choose Sensor, then ph/mv/orp Amplifier and then ph.) Leave the interface window open. 3. Prepare the electrode for use. Remove the electrode from its small plastic storage bottle by unscrewing the top until you can slide the electrode out of the bottle. Set the bottle aside where it will not get knocked over. Rinse it off thoroughly (see the RINSING A ph ELECTRODE section, below). 4. Calibrate the electrode. (a) Click on the white box for CH 1. From the menu click on Calibrate. Then click on the Calibrate Now box. (b) Immerse the electrode in a ph 4 or 7 buffer solution and swirl it briefly (a couple of seconds) to remove any air bubbles or dilute any water droplets clinging to the end of the electrode. The bulb at the bottom of the electrode must be completely submerged in order to get an accurate reading. (c) Enter the ph of the buffer solution (that the electrode is in) in the box for Reading 1. (d) Wait until the voltage reading stabilizes and then click on Keep. Frequently, the last digit will be fluctuating this is normal. (e) Remove the electrode from the solution and rinse it thoroughly. (f) Place the electrode in the other buffer solution and swirl it briefly (a few seconds). (g) Enter the ph of the second buffer solution in the box for Reading 2. (h) Wait until the voltage reading stabilizes and then click Keep. The two readings should differ by 0.6 0.7 V. (i) Click on Done. (j) Close the LabPro interface window. If the calibration was done properly, the ph reading at the bottom of the screen should be approximately equal to the ph of the last buffer solution ( 0.03). You are now ready to measure the ph of solutions. Simply immerse the ph electrode in a solution, swirl briefly to equilibrate, and read the ph when it stabilizes. RINSING A ph ELECTRODE 1. Thoroughly rinse the electrode by spraying it with distilled water from a wash bottle. Be sure to spray the bottom where the sensitive ph glass is located. 2. Wipe the outside with a Kimwipe, and then give it a couple of firm shakes to remove the water from the bulb. Do NOT dry the bulb of the electrode with a Kimwipe or a paper towel. The glass bulb of the ph electrode is very fragile. Be careful not to drop the electrode or hit it against something (like the edge of the sink or your lab partner), electrodes are expensive (and lab partners are valuable)! 9-6

Name Station Used Instructor/Day/Time Partner Partner Station Checked & Approved PRELAB CALCULATIONS It is essential that this section be completed before coming to lab in order to have time to complete the experiment. The instructor may check that you have done this before you are permitted to start work. 1. Describe exactly how you will prepare 100 ml each of 0.010, 0.0010 and 0.00010M HCl solutions by dilution of the 0.10M HCl provided. 9-7

DATA SHEET & DATA ANALYSIS Record all values to the proper number of significant figures and with appropriate units (when applicable). ph of tap water ph of distilled water ph of HCl: 0.10M ; 0.010M ; 0.0010M ; 0.00010M ph of 0.10M acetic acid 1. Typically, how much does the ph increase each time the [HCl] decreases by a factor of ten? 2. Based upon the measured ph of the 0.10 M HCl and acetic acid solutions, which is the stronger acid: HCl or acetic acid? How can you tell based upon your data? 9-8

Hydrolysis Study (for each salt, a single hydrolysis reaction should occur): ph of 0.10M ammonium chloride Write the hydrolysis reaction that should have occurred for this salt. ph of 0.10M sodium acetate Write the hydrolysis reaction that should have occurred for this salt. ph of 0.10M sodium carbonate Write the hydrolysis reaction that should have occurred for this salt. 9-9

DATA SHEET & DATA ANALYSIS (Continued) Each individual should attach this sheet containing his/her own buffer capacity results. Buffer Capacity Determination: Name Unknown Number ph reading Buret reading Initial Final Change in Volume Concentration of standard NaOH solution Calculate the buffer capacity of the undiluted, unknown buffer. Show your calculation, as always. buffer capacity 9-10