Isover Solutions Guide

Similar documents
ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Rockwool Flexi Insulation Application Guide

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Timber Frame Walls Rethinking Construction

The Kingspan Insulation Price List 1 st January 2013

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Acoustics factsheet Requirements for new homes and how NHBC can help

Rev Code of Practice. SIP Technology.

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Module 3.7. Thermal bridging

Multi-layer Insulation Blanket for Roofs

SIP (STRUCTURAL INSULATED PANEL)

Rockwool Cladding Roll

Guide to domestic building renovation. Telephone: Fax:

The Pocket Guide To Insulation August 2013

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Energy Company Obligation (ECO): Technical Monitoring Questions

Innovation - High performance roof, wall and floor insulation board. delivering better performance

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

Building Regulations for the Conservation of Fuel and Power

Manual lifting and handling

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

Internal wall insulation in existing housing

ProRox Slabs (formerly known as RW slabs)

Building Control Guidance Note

Understanding BS EN 771-3: Aggregate concrete masonry units

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

British Gypsum Guide to Timber Frame Construction. March 1998

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Agrément Certificate 06/4300 Product Sheet 1

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Lightweight Partition Design for Residential and Commercial Buildings

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Including. Rubershield-Pro. Breather Membrane

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

BER Assessors Dwellings Technical Bulletin

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

SIG SIG CAVITY WALL INSULATION

The Real Value of Space

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

PB301 July Lightweight Building Solutions. Bushfire Protection.

Composite Panel Firewall Systems

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

DOMESTIC & GENERAL INSULATION LTD BLOWN-IN CAVITY WALL INSULATION THERMABEAD, THERMABEAD CARBON SAVER AND THERMABEAD DIAMOND CWI

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

Low Energy Low Carbon Buildings

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

PRODUCT GUIDE lower tolerances high quality

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Steel-framed Walls. Insulation

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

2014 British Columbia Building Code Changes

Airtight Intelligence

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings.

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Asphalt Shingle Application Requirements

How To Certify The Scottsdale Construction System

sound reduction systems for commercial, educational and industrial environments

Low Energy Low Carbon Buildings

Roof Insulation Building. Energy. Environment friendly e-library

Chapter 2 Basis of design and materials

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION

Sixth Issue March Kingspan. Building System. CERTIFICATE No. 02/0158. Low Energy - Low Carbon Buildings

Guide to the safe installation of downlighters in dwellings

Roofers Guide to Underslating Membranes

INSTABEAD CAVITY WALL INSULATION SYSTEM INSTABEAD WHITE, INSTABEAD CARBON SAVER AND INSTABEAD DIAMOND CAVITY WALL INSULATION

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

Mineral fibreglass insulation

Residential Refurbishment. September ThermoShell Internal Wall Insulation System Design Guide

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE.

fire separating walls #2

0331 Brick and block construction

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

H-Stud Area Separation Wall System

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Conventions for U-value calculations

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

Transcription:

Isover Solutions Guide Specifying Separating Masonry Cavity Wall Insulation

About Saint-Gobain Isover As a world leader in designing, manufacturing and distributing building materials, Saint-Gobain is committed to providing innovative solutions to the most fundamental challenges facing the world today; reducing energy consumption, limiting our impact on the environment and creating a new generation of buildings which are safe, comfortable and energy efficient. Saint-Gobain: one of the top 100 industrial groups in the world and the global leaders in the construction market. Isover consistently deliver innovative solutions that minimise noise disruption and provide a peaceful environment. At Saint-Gobain Isover we develop sustainable insulation solutions to protect both your built environment and the natural environment. To maintain our focus we have placed environmental responsibility at the heart of our business strategy. Our vision to lead the UK mineral wool market in energy efficiency and acoustic insulation solutions will be achieved with products that meet the highest thermal, acoustic and fire safety performance levels. We will meet changing regulations first and surpass current regulations for those that wish to excel. Our products will provide best value solutions for the residential, commercial, RMI and technical building environments, be safe to use and help to protect the environment. According to the European Noise Policy, 80 million EU citizens (20% of the EU population) are exposed to undesirably high noise levels, which lead to sleep disturbance and other adverse health effects such as: high blood pressure, mental stress, heart attacks and hearing damage. In addition, noise and poor room acoustics can have a negative effect on learning and working. For these reasons, noise reduction is an increasing priority in both residential and non-residential projects. At Saint-Gobain Isover we consistently deliver innovative solutions that minimise noise disruption and provide a peaceful environment. 2 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Benefits of using Isover Since Approved Document L regulation changes in 2010, designers and contractors now have the added complication of meeting both acoustic and thermal requirements for separating walls. Isover provides solutions to meet and exceed these regulations, whilst improving the time and cost of installing products on-site. Thermal insulation Robust Detail compliant Isover has the widest choice of proprietary Robust Details on the market. E-WM-17, E-WM-20 and E-WM-24 all provide: Proven practical site solutions delivering thermal and acoustic performance. No requirements for PCT (Pre-Completion Testing). Thermal bypass solutions can be used in a fully-filled cavity with effective edge sealing to deliver zero U-values for separating walls as defined in Building Regulations Approved Document L1A (England and Wales) and Section 6 (Scotland). No requirement for render or parge-coating E-WM-17, E-WM-20 and E-WM-24 dry-finish solutions with no requirement for render or parge-coating prior to drylining. Environmental leadership Isover insulation has excellent environmental credentials and helps towards valuable credits for the Code for Sustainable Homes. Isover separating cavity wall insulation achieves the highest BRE Global Green Guide online summary rating. See the Product Overviews on pages 16 and 17 for more information. Recycled content of up to 86%. Zero Ozone Depletion Potential (ODP). Global Warming Potential (GWP) of less than 5. Single block and plasterboard solution E-WM-24 incorporating Isover RD Party Wall Roll uses aircrete blocks and standard 8kg/m 3 plasterboard so both can be used for the party and external wall. See page 14 for further details Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 3

Building regulations & standards Approved Document E 2003 Clause E1 Separating wall constructions (often refered to as party wall constructions) must be built to comply with Building Regulations Approved Document E clause E1 and are subject to Pre-Completion Testing unless a Robust Detail construction is used. Clause E1 of Approved Document E stipulates the following: Dwelling-houses, flats and rooms for residential purposes shall be designed and constructed in such a way that they provide reasonable resistance to sound from other parts of the same building and from adjoining buildings. Approved Document E 2003 Performance standards The following table is adapted from Approved Document E and highlights the minimum performance standards required for separating walls. Please note that the requirement is for airborne sound insulation only. Performance standards for separating walls that have a separating function Airborne sound insulation DnTw + Ctr db (Minimum values) Purpose built dwelling-houses and flats 45 - Dwelling-houses and flats formed from material change of use 43 - Impact sound insulation L nt, w db (Minimum values) Section 5 Scotland Section 5 (Scotland) stipulates a minimum airborne sound performance for separating walls of 56 db Dntw. Please be aware that Scottish Regulations do not recognise a correction factor for low frequency sound. Separating walls 56 Airborne sound insulation db DnTw (Minimum values) How to comply Robust Details All Robust Details have been approved as capable of meeting or exceeding the E1 performance criteria, providing they are built correctly. Following these specifications means the construction can be exempt from undertaking Pre-Completion Testing. The Robust Details scheme applies to new-build houses and apartments only. Plots must be registered with Robust Details Limited prior to construction. NB It is important to check the compatibility of the Robust Detail separating walls with the Robust Detail separating floors. Please refer to www.robustdetails.com for more information. Manufacturers Proprietary Systems These constructions, provided they are built correctly, have the potential to achieve E1 performance criteria required for new-build houses and apartments separating wall constructions and new-build rooms for residential purposes. Pre-Completion Testing must be executed on a 10% sample (by type) to demonstrate compliance. The Code for Sustainable Homes Within category 7 of the Code for Sustainable Homes, Health and Wellbeing, section Hea 2 states that up to four credits are available for achieving higher standards of sound insulation than those given in Building Regulations Approved Document E and demonstrating it by using either Pre-Completion Testing or Robust Details. This stamp highlights construction details which have the potential to achieve the number of credits stated, provided they are built correctly. See the Isover Installation Guide - Installing Separating Masonry Cavity Wall Insulation for guidance. 4 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Building regulations & standards Approved Document L1A 2010 Thermal requirements The revisions to Approved Document L1A 2010 will no longer treat separating cavity walls as a zero heat loss element, due to a phenomenon known as the 'thermal bypass' or 'party wall bypass' effect. The heat loss can be reduced by measures that restrict air movement through the party cavity, either by means of fully-filling the cavity and/or by providing effective sealing around the perimeter. Table 3 U-values for party walls Party wall construction U-value (W/m 2 K) U-value (W/m 2 K) Solid 0.0 Unfilled cavity with no effective edge sealing 0.5 Unfilled cavity with effective edge sealing around all exposed edges 0.2 and in line with insulation layers in abutting elements A fully filled cavity with effective sealing at all exposed edges and in 0.0 line with insulation layers in abutting elements Scotland Scottish regulations also recognise that separating walls should no longer be treated as zero heat loss. Section 6 stipulates the following: To limit heat loss, a separating wall cavity should have effective perimeter sealing around all exposed edges and in line with insulation layers in abutting elements which separate the dwelling from another building or from an unheated space. Further reduction in heat loss can be achieved where the cavity separating wall is also fully-filled with a material that limits air movement. What is meant by thermal bypass? Thermal bypass is simply where heat bypasses insulation and escapes to the external environment. This can occur where a cavity internal to the insulation layer is able to communicate with the external environment, thus causing heat loss from a location in the building that isn t considered to be so affected or allows the transport of heat around the insulation. Thermal bypasses can render the insulation layer completely irrelevant to the flow of heat in localised areas and significantly worsen the fabric energy efficiency of the building. Isover party wall thermal bypass solutions Zero U-value solutions This stamp highlights construction details which have potential to achieve a zero U-value, provided they are built correctly. Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 5

Isover thermal bypass solution In order to eliminate heat loss from a property into a separating cavity or reduce heat transfer between properties, a zero U-value separating cavity wall must be achieved. As highlighted in Approved Document L1A, Table 3, this can be achieved by attaining the following two elements: Filling of the cavity Effective edge sealing The Isover solution to thermal bypass meets the requirements for both fully-filling the cavity and effective edge sealing, therefore achieving a zero U-value separating wall. Filling of the cavity The purpose of a fully-filled cavity is twofold, to prevent air movement within the cavity, and to provide thermal insulation to reduce heat flow to the separating cavity or the adjoining property. is a full-fill glass mineral wool rolls for use in masonry separating wall cavities. The products meet the full-fill requirement to help deliver a zero U-value for separating walls as defined in Building Regulations (Approved Document L1A, Table 3). Effective edge sealing The purpose of additional edge sealing is to eliminate the possibility of air movement from the separating cavity to the external environment, or vice versa. By fully-filling the external cavity with Isover insulation and tightly butting the insulation at the separating wall junction, additional edge sealing will not be required. However, an Isover ULTIMATE Cavity Barrier will be required to achieve effective edge sealing if the external wall is partially-filled with a rigid foam board. The information detailed above is guidance only and it is up to the designer / specifier to ensure that they speak with the local building control officer / NHBC officer to determine the acceptability of this statement or request for cavity barriers. The following pages show guidance details for external wall, roof and ground floor junction detailing. On-site performance testing The thermal performance of the Isover solution has been proven by means of in-situ testing. The reports state that by fully-filling the separating cavity with Isover insulation, the system eliminates heat loss from the separating wall to the external environment through convection, therefore achieving a zero U-value and escaping penalties in SAP2009 calculations. Wall Ties separating The following text gives generic guidance for the installation of cavity wall ties. For a detailed installation procedure and guidance, advice should be sought from the wall tie manufacturer. Wall ties are vital for securing the structural integrity of a wall. Installing them incorrectly can lead to acoustic weak spots, cracking or even the collapse of walls. Spacing For walls where both leaves are thicker than 90mm, position wall ties at a maximum of 900mm horizontal x 450mm vertical centres (2.5 per m²). Ties should be evenly distributed over the wall area and should preferably be staggered. Around openings, position wall ties with a minimum vertical spacing of 300mm (usually 225mm to suit one block course) and no more than 225mm from the edge of the opening. Additional guidance Wall ties are a primary source of acoustic transmission. For this reason it is important to prevent mortar build up around the wall ties and at the foot of the cavity. Bridging effects can lead to significant sound transmission between attached properties, by-passing any useful isolation effect that the cavity provides and may result in significant reduction in acoustic isolation performance. BRE Green Guide Construction statements For the full BRE Green Guide online generic construction rating specification, please visit: www.bre.co.uk/ greenguide 6 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Guidance detailing External (flanking) wall junction Fully-filled cavity Masonry outer leaf External cavity fully-filled with Isover CWS 32 or Isover CWS 36 Separating cavity fully-filled with Insulation at the external wall junction must be tightly butted to provide effective edge sealing Partial-filled cavity Masonry outer leaf External cavity partially-filled Separating cavity fully-filled with Isover ULTIMATE cavity barrier compression fit with the external wall cavity to provide effective edge sealing (minimum of 50mm overlap either side of the separating cavity) Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 7

Robust detailing - Roof junction Roof junction - pitched roof without room-in-roof Junction between separating wall and roof filled with flexible closer Cavity masonry separating wall continuous to underside of roof. Alternatively use spandrel panel External wall cavity closed at eaves level with a suitable flexible material (e.g. mineral wool). If a rigid material is used, then it should only be bonded to one leaf 300mm (min) 100mm Isover ULTIMATE Cavity Barrier (CAP) Edge Seal 100mm (min) mineral wool insulation 10kg/m 2 (no gaps to remain) Section Continuous horizontal ribbon of adhesive Roof junction - pitched roof with room-in-roof Junction between separating wall and roof filled with flexible closer 100mm (min) mineral wool insulation minimum density 10kg/m 3 or 60mm (min) foil faced PUR or PIR insulation, minimum density 30kg/m 3 (See Appendix A) Section Room-inroof Room-inroof 2 layers of nominal 8kg/m 2 gypsum-based board. Where used rigid insulation may be placed between and/or directly beneath rafters Continuous horizontal ribbon of adhesive Cavity masonry separating wall continuous to underside of roof covering (no gaps to remain) External wall cavity closed at eaves level with a suitable flexible material (e.g. mineral wool). If a rigid material is used, then it should only be bonded to one leaf 8 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Isover guidance detailing Roof junction Cold roof Isover ULTIMATE cavity barrier compression fit between the top of the separating wall and roof covering, spanning the full width of the cavity to provide effective edge sealing and fire protection Continuous separating wall up to roof level Separating cavity fully-filled with 170-300mm Isover loft insulation over joists 100mm Isover loft insulation between joists Room-in-the-roof Isover ULTIMATE cavity barrier compression fit between the top of the separating wall and roof covering, spanning the full width of the cavity to provide effective edge sealing and fire protection Isover Room-in-the-Roof insulation installed between rafters to meet building regulations Continuous separating wall up to roof level Separating cavity fully-filled with Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 9

Isover guidance detailing Ground floor junction Concrete floor Cavity fully-filled with Ground floor not continuous between dwellings in order to prevent acoustic transfer Damp proof membrane Cavity carried down a minimum of 225mm below the ground floor level to prevent any acoustic bridging Timber floor Cavity fully-filled with Ground floor not continuous between dwellings in order to prevent acoustic transfer Damp proof membrane Cavity carried down a minimum of 225mm below the ground floor level to prevent any acoustic bridging caused by mortar build up at the base of the cavity. 10 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

E-WM-24 E-WM-24 Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Solutions overview The separating masonry cavity wall solutions detailed in this section of the guide are proprietary Robust Detail constructions, incorporating Isover insulation. These constructions have been tested and proven to meet or exceed the sound insulation values given in the table on page 4. Construction to meet = Approved Document E 2003 1 CfSH Credit 3 CfSH Credits 4 CfSH Credits Separating Wall Solutions (DnTw + Ctr db) 42 43 44 45 46 47 48 49 50 51 52 53 54 E-WM-17 Lightweight aggregate blockwork ( and Gyproc plasterboard) E-WM-20 Lightweight aggregate blockwork ( and Gyproc plasterboard) E-WM-24 Aircrete blockwork (Isover RD Party Wall and Gyproc plasterboard) Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 11

Solution overview Robust Detail E-WM-17 corresponds to the BRE Global Green Guide online generic specification 'Robust Detail E-WM-17' ref 918190009 which achieves a summary rating of B within Domestic. E-WM-17 Lightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Robust Detail approved construction 1 1350 to 1600kg/m 3 Plasmor Aglite Ultima 1050kg/m 3 or Besblock 'Star performer' cavity wall block 2 Minimum 75mm cavity between leaves 3 Minimum 75mm Isover RD Party Wall Roll in the cavity 4 Drylined with dot and dabbed 12.5mm Gyproc WallBoard ten, 15mm Gyproc WallBoard or 12.5mm Gyproc SoundBloc 9.8kg/m 2 2 3 1 4 Use this solution to: 3 Achieve three credits towards The Code for Sustainable Homes whilst keeping wall footprint to a minimum 3 Meet the full-fill requirement to help deliver a zero U-value party wall 3 Have no requirement for render or parge coating prior to drylining 3 Have no requirement for PCT (Pre-Completion Testing) 12 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Solution overview E-WM-20 Lightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Robust Detail approved construction 1 Lightweight aggregate cavity block wall, minimum 100mm blocks (density 1350 1600kg/m 3 ) 2 Minimum 100mm cavity between leaves 3 Minimum 100mm Isover RD Party Wall Roll in the cavity 4 Drylined with dot and dabbed 12.5mm Gyproc WallBoard ten, 15mm Gyproc WallBoard or 12.5mm Gyproc SoundBloc 9.8kg/m 2 2 E-WM-20 3 E-WM-20 1 4 B Green Guide Robust Detail E-WM-20 corresponds to the BRE Global Green Guide online generic specification 'Robust Detail E-WM-20' ref 918190009 which achieves a summary rating of B within Domestic Use this solution to: 3 Achieve three credits towards The Code for Sustainable Homes 3 Meet the full-fill requirement to help deliver a zero U-value party wall 3 Have no requirement for render or parge coating prior to drylining 3 Have no requirement for PCT (Pre-Completion Testing) Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 13

Solution overview B Robust Detail E-WM-24 corresponds to the BRE Global Green Guide online generic specification 'Robust Detail E-WM-24' ref 918190001 which achieves a summary rating of B within Domestic. E-WM-24 Aircrete blockwork ( and Gyproc plasterboard) Robust Detail approved construction 1 Aircrete cavity block wall, minimum 100mm blocks (density 600 800kg/m 3 ) 2 Minimum 100mm cavity between leaves 3 in the cavity 4 Drylined with 12.5mm Gyproc WallBoard dot and dabbed (DriLyner basic system) E-WM-24 3 E-WM-24 1 4 2 Use this solution to: 3 Use a single block and plasterboard for both the party and external wall 3 Improve SAP score through improved PSI value at external wall junction 3 Meet the full-fill requirement to help deliver a zero U-value party wall 3 Have no requirement for render or parge coating prior to drylining 3 Have no requirement for PCT (Pre-Completion Testing) 14 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Solutions overview Non Proprietary Robust Details also conforms to the Robust Details generic full-fill mineral wool specification for the following non-proprietary details. Fully-filling these details with either 75mm or 100mm will help deliver a zero U- value for the party wall as defined in Building Regulations (Approved Document L1A, Table 3). RD Ref Description Isover product E-WM-1 E-WM-2 E-WM-3 E-WM-4 E-WM-5 E-WM-6 E-WM-10 E-WM-11 E-WM-12 E-WM-13 E-WM-16 E-WM-18 E-WM-19 E-WM-21 Dense aggregate blockwork (wet plaster) Lightweight aggregate blockwork (wet plaster) Dense aggregate blockwork (render and gypsum-based board) Lightweight aggregate blockwork (render and gypsumbased board) Besblock 'Star performer' cellular blockwork (render and gypsum-based board) Aircrete blockwork (render and gypsum-based board) Thin-joint aircrete blockwork (render and gypsumbased board) Lightweight aggregate blockwork (render and gypsumbased board) with 100mm (min) cavity Plasmor 'Aglite Ultima' lightweight aggregate blockwork (render and gypsum-based board) Untied thin-joint aircrete blockwork (render and gypsum-based board) Dense aggregate blockwork (render and gypsum-based board) with 100mm (min) cavity Dense aggregate blockwork (wet plaster) with 100mm (min) cavity Dense or lightweight aggregate blockwork (render and gypsum-based board) with 100mm (min) cavity and MONARFLOOR BRIDGESTOP system Lightweight aggregate blockwork (wet plaster) and 100mm (min) cavity 75mm or 100mm 75mm or 100mm 75mm or 100mm 75mm or 100mm 75mm or 100mm 75mm or 100mm 75mm or 100mm 100mm 75mm or 100mm 75mm or 100mm 100mm 100mm 100mm 100mm CfSH credits 0 1 1 1 1 1 0 3 0 3 3 3 4 3 Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 15

Product overview A glass mineral wool roll designed for use in E-WM-17, E-WM-20 and E-WM-24 Robust Details wall constructions to exceed acoustic performance requirements set out in Building Regulations Approved Document E (England and Wales). The product also conforms to the Robust Details generic full-fill mineral wool specification for all other masonry cavity separating details. 3 Thermal bypass solution meets the full requirement to help deliver zero U-value for party walls as defined in Building Regulations (Approved Document L1A, Table 3) 3 Robust Detail accredited 'dry-finish' solution with no requirement for render or parge coating prior to drylining 3 No requirements for PCT (Pre-Completion Testing) Easy to install Proven practical site solutions delivering thermal and acoustic performance Assured quality of installation roll format ensures minimal or no vertical joints is manufactured from high quality glass mineral wool which makes it lightweight and easy to handle, cut and install Water resistant Resilient to moisture damage in storage, during transportation and on-site during installation. Euroclass A1 fire rating Totally non-combustible and fire safe. Protected planet Excellent environmental credentials and helps towards valuable credits for the Code for Sustainable Homes. corresponds to the BRE Global Green Guide online generic specification Glass wool insulation density 24kg/m³ (ref. 815320002) which achieves a summary rating of A+ within all building types Recycled content of up to 86% Zero Ozone Depletion Potential (ODP) Global Warming Potential (GWP) of less than 5 Product Thickness (mm) Width (mm) Length (mm) 75 2 x 455 8500 7.74 100 2 x 455 6000 5.46 125 2 x 455 5000 4.55 150 2 x 455 4000 3.64 Pack area (m²) 16 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Insulation solution for dual purpose cavity walls 125mm and 150mm is designed for use in dual purpose walls, which have separating and external functions. The product brings the following benefits for Housebuilders: Achieve the required external wall U-value without the requirement for corbelling Comply with Robust Details E-WM-17, E-WM-20 or E-WM-24 with a cavity greater than 100mm Meet the full-fill requirement to help deliver a zero U-value party wall www.isover.co.uk

Product overview Isover ULTIMATE Cavity Barriers An ULTIMATE mineral wool cavity barrier providing a solution to acoustic flanking, excellent fire performance Fire performance: 30, 60 or 120 minutes integrity - 30, 60 or 120 minutes insulation Typical applications: Excellent fire protection in the following details 3 External and separating cavity wall junction 3 External cavity walls at eaves level 3 Separating cavity wall and roof junction 3 External cavity wall and compartment wall junction 3 External cavity wall and separating floor junction Fire performance 30, 60 or 120 minute fire performance. Provides 30, 60 or 120 minutes fire protection in concealed cavities to help meet the requirements of Part B Fire Building Regulations (England and Wales) and Section 2 (Scotland). Acoustic insulation Helps to meet the requirements of Approved Document E Acoustic Building Regulations 2003 (England and Wales) and Section 5 (Scotland) by minimising flanking sound transmission along the wall cavity. Easy to install Excellent compression properties, which allows for the barrier to be easily installed into cavities without risking damage to brickwork. Colour-coded packaging prevents installation of the incorrect barrier sizes on-site Euroclass A1 fire rating Totally non-combustible and fire safe Protected planet Environmental Credentials Zero Ozone Depletion Potential (ODP) Global Warming Potential (GWP) of less than 5 Product Cavity Size (mm) Length (mm) Width (mm) Isover ULTIMATE Cavity Barrier - 30 minute 50-65 1200 100 Yellow Isover ULTIMATE Cavity Barrier - 30 minute 66-80 1200 100 Blue Isover ULTIMATE Cavity Barrier - 30 minute 81-100 1200 100 White Isover ULTIMATE Cavity Barrier - 60 minute 50-65 1200 200 Yellow Isover ULTIMATE Cavity Barrier - 60 minute 66-80 1200 200 Blue Isover ULTIMATE Cavity Barrier - 60 minute 81-100 1200 200 White Isover ULTIMATE Cavity Barrier - Party Wall 50-65 1200 300 Yellow Isover ULTIMATE Cavity Barrier - Party Wall 66-80 1200 300 Blue Isover ULTIMATE Cavity Barrier - Party Wall 81-100 1200 300 White Isover ULTIMATE Cavity Barrier - Storey Height 50-65 2400 300 Yellow Isover ULTIMATE Cavity Barrier - Storey Height 66-80 2400 300 Blue Isover ULTIMATE Cavity Barrier - Storey Height 81-100 2400 300 White Sleeve colour 18 www.isover.co.uk Isover Technical Advice Tel: 0115 945 1143

Achieving high levels of acoustic and thermal comfort in separating masonry cavity walls Installation guide Isover also publish an installation guide for separating masonry cavity wall insulation. The objective of the guide is to support the industry with best practice guidance to achieve efficient installation with consistently high levels of on-site performance. The guide includes: 3 Preparation details and generic guidance 3 A step-by-step guide to installing Isover party wall insulation 3 An overview of Isover's party wall products Isover Installation Guide Installing Separating Masonry Cavity Wall Insulation For more information or to order a copy of the guide please visit www.isover.co.uk Isover Technical Advice: isover.enquiries@saint-gobain.com www.isover.co.uk 19

www.3pointplan.co.uk www.isover.co.uk Isover Order Placement or Order Enquiries: Tel: 0800 032 2555 Fax: 0800 917 9188 Published Date: July 2014 Isover Document Reference: I-SMW-SG-1402 Isover Technical Advice Buildings Insulation: Tel: 0115 945 1143 Email: isover.enquiries@saint-gobain.com Saint-Gobain Isover Gotham Road East Leake Loughborough Leicestershire LE12 6HX Tel: +44 (0) 115 969 8010 Email: isover@saint-gobain.com Isover reserves the right to revise product specifications without notice. The information in this document was correct to the best of our knowledge at the time of publication. It is the users responsibility to ensure that it remains current prior to use. The information in this document is for guidance only and should not be read in isolation. Users should read and familiarise themselves with all the information contained in this document and ensure that they are fully conversant with the products and systems being used, before subsequent specification or installation. For a comprehensive and up to date library of information visit the Isover website.