How To Build A Data Center For Afir



Similar documents
ITB2 Datacenters Informationbrochure 2015 Page: 2


PRIMERGY server-based High Performance Computing solutions

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

World s Greenest High Performance Data Center

Kriterien für ein PetaFlop System

Introduction to Datacenters & the Cloud

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Data Center Technology: Physical Infrastructure

Green Computing: Datacentres

HPC and Big Data. EPCC The University of Edinburgh. Adrian Jackson Technical Architect

Scalable. Affordable. Flexible. Fast.

Global Data Center & Colocation Facilities

DATA CENTERS BEST IN CLASS

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

GREEN DATA CENTER DESIGN

Low-cost BYO Mass Storage Project. James Cizek Unix Systems Manager Academic Computing and Networking Services

Welcome to the. Jülich Supercomputing Centre. D. Rohe and N. Attig Jülich Supercomputing Centre (JSC), Forschungszentrum Jülich

Data Center Planning. PUE Overview

IBM Spectrum Scale vs EMC Isilon for IBM Spectrum Protect Workloads

The L-CSC cluster: Optimizing power efficiency to become the greenest supercomputer in the world in the Green500 list of November 2014

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Green Data Centre Design

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

PAYGO for Data Center -- Modular Infrastructure

Enabling an agile Data Centre in a (Fr)agile market

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers

Eni Green Data Center - Specification

greendatacenter Lupfig

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Specialty Environment Design Mission Critical Facilities

Europe s greenest data center

KIT Site Report. Andreas Petzold. STEINBUCH CENTRE FOR COMPUTING - SCC

European Business Reliance Centres when Commodity serves Green IT

Five Essential Components for Highly Reliable Data Centers

Fujitsu PRIMERGY Servers Portfolio

Building a Top500-class Supercomputing Cluster at LNS-BUAP

Green Computing: Datacentres

DATA CENTER ASSESSMENT SERVICES

Leveraging Renewable Energy in Data Centers: Present and Future

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Our Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security.

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

Case Study. Cool and green: Citigroup s Frankfurt Data Center

ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford

Siemens SAP Cloud - Infrastructure as a Service

HPC TCO: Cooling and Computer Room Efficiency

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

Computational infrastructure for NGS data analysis. José Carbonell Caballero Pablo Escobar

How To Design A Data Center

Warehouse-scale Design Reaches Retail Colocation High Density, Modern And Green

DATACENTER COLOCATION. Flexible, Secure and Connected

DATASHEET FUJITSU ETERNUS LT250 TAPE LIBRARY

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

Capgemini UK Infrastructure Outsourcing

Direct Fresh Air Free Cooling of Data Centres

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

DataCenter 2020: first results for energy-optimization at existing data centers

Improve competiveness of IDC and enterprise data centers with DCIM

Energy Efficient High-tech Buildings

Data Centre Testing and Commissioning

Fujitsu PRIMERGY Servers Portfolio

I don t want to move to the Arctic - a HPC Data Center Take on PUE and Energy Efficiency

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Data Center Infrastructure Management. Experience the inner calm that comes with successful data center management.

Three Steps To Perfectly Green

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Datasheet FUJITSU Storage ETERNUS LT250 TAPE LIBRARY

Data Sheet Fujitsu ETERNUS CS High End V5.1 Data Protection Appliance

Mississippi State University High Performance Computing Collaboratory Brief Overview. Trey Breckenridge Director, HPC

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

CEDA Storage. Dr Matt Pritchard. Centre for Environmental Data Archival (CEDA)

Direct Contact Liquid Cooling (DCLC ) PRODUCT GUIDE. Industry leading data center solutions for HPC, Cloud and Enterprise markets.

Case Study: Guaranteed efficiency through standardised data centres

Bill Younger, Manager Business Energy Management Puget Sound Energy Bellevue, Washington

Server Consolidation for SAP ERP on IBM ex5 enterprise systems with Intel Xeon Processors:

University of St Andrews. Energy Efficient Data Centre Cooling

How to build your Data Center Digitice roadshow Vaasa

Transcription:

Green Cube GSI FAIR Tier 0 Thorsten Kollegger FAIR & GSI 30. March 2015 AIME Big Data - Budapest

Green Cube New data center at GSI, mainly for FAIR Tier0 6 floors, ~25x35 sqm footprint T. Kollegger AIME Big Data, Budapest 30. March 2015 2

GSI & FAIR GSI Helmholtz Center for Heavy Ion Research FAIR Facility for Antiproton and Ion Research Located in Darmstadt, Germany ~1.300 employees and ~3.000 worldwide users T. Kollegger AIME Big Data, Budapest 30. March 2015 3

FAIR Currently under construction Fully operational in the next decade, ~1B EUR investment European project of 8 member states + ~50 international partners T. Kollegger AIME Big Data, Budapest 30. March 2015 4

FAIR Science time Atomic, applied and plasma physics - APPA Hadron structure - PANDA Astrophysics and nuclear structure - NUSTAR QCD phase transition - CBM temperature big bang T. Kollegger 21.11.2014

FAIR Computing The FAIR experiments will produce tens of PetaBytes of raw data per year, with up to 1 TByte/s from the experiments to the Tier0, which need to be safely and permanently stored analyze these datasets over several years, requiring also extensive simulations and theory calculations T. Kollegger AIME Big Data, Budapest 30. March 2015 6

FAIR Computing FAIR Tier 0 @ full FAIR operation 300.000 CPU-cores 35 PByte/year Online-Storage (HDD) 30 Pbyte/year Permanent-Storage (Tape) Comparable resources in FAIR partner countries Key Points Few big, highly efficient data centers Further partner connected via regional federations Co-T0(s) in FAIR Partner Country(-ies) T0@FAIR/GSI T0 Teralink Federation Partners (~T2) T1 s or Regional Federations in FAIR Partner Countries (T1+T2) T. Kollegger AIME Big Data, Budapest 30. March 2015 7

FAIR Tier 0 @ GSI FAIR Tier 0 is the core of the FAIR Computing Model Experiment Online Farms connected via ~4000 fibres to Experiments Experiment Storage Systems Experiment Processing Farm Integration of HPC Centers of surrounding partners (Teralink) Co-T0(s) in FAIR Partner Country(-ies) Distribution of experimental data to FAIR Partners; several 100 Gb/s links T0@FAIR/GSI T0 Teralink Federa on Partners T1 s or Regional Federa ons in FAIR Partner Countries (T1+T2) T. Kollegger AIME Big Data, Budapest 30. March 2015 8

FAIR Data Center A common data center for FAIR (Green Cube) Key Facts 6 floors, 4.645 sqm Space for 768 19 racks (2,2m) 4 MW cooling (baseline) Max cooling power 12 MW Fully redundant (N+1) PUE <1.07 T. Kollegger AIME Big Data, Budapest 30. March 2015 9

An Alarming Truth World wide air-traffic causes around 2 % of the global CO 2 emission just as much as commercial IT! (ca. 30 GW) [Gartner] Volker Lindenstruth (www.compeng.de) May 22, 2012 Copyright, Goethe Uni, Alle Rechte vorbehalten 10

Data Center State of the Art Electrical Power UPS 10% Data Center Cooling 12% Light, etc. 3% IT Equipment 50% PUE = Total Facility Power IT Equipment Power Power Usage Effectiveness Back Cooling 25% PUE = 2 (typical PUE = 1,6 to 3,5) Note: 12C/kWh 1W = 1,05 /a Source: EYP Mission Critical Facilities Inc., New York Volker Lindenstruth (www.compeng.de) May 22, 2012 Copyright, Goethe Uni, Alle Rechte vorbehalten 11

Innovative Cooling System Architecture Cooling Overhead 5% of computer power evaporation cooling tower data center building server room draw-off air air cooling tower fixtures makekupwater equipment container M M Primary Cooling circuit Secondary Works with every commercial computer cooling circuit secondary pump heat exchanger primary pump Volker Lindenstruth (www.compeng.de) 30. März 2015 Copyright, Goethe Uni, alle Rechte vorbehalten

Wet bulb temperature 2010 Volker Lindenstruth (www.compeng.de) 30. März 2015 Copyright, Goethe Uni, alle Rechte vorbehalten 13

Volker Lindenstruth (www.compeng.de) 30. März 2015 Copyright, Goethe Uni, alle Rechte vorbehalten Heiko Ebermann 14

Prizes Green-IT Award Bundesregierung Visionäre Gesamtkonzepte Deutscher Rechenzentrumpreis 2012 energy efficiency Deutscher Rechenzentrumspreis 2013 Visionary Datacenter Architecture Nominated for Deutscher Rechenzentrumspreis 2014 energy efficency DataCenterDynamics EMEA Award 2013 Data Center Blueprint BroadGroup EMEA Awards Special Commendation Energy Efficiency Land der Ideen 2012 for LOEWE-CSC Green Cube Project of the Month, BMBF 5 Nominations with 4 ranks at Data Center Dynamics EMEA Awards 2011, 2012, 2013 2nd rank at Deutsche Internet Awards 2012 Volker Lindenstruth (www.compeng.de) 30. März 2015 Copyright, Goethe Uni, alle Rechte vorbehalten 15

The FAIR Data Center (Green Cube) Space for 768 19 racks (2,2m) 4 MW cooling (baseline) Max cooling power 12 MW Fully redundant (N+1) Can be used for any commercial IT No battery backup required PUE <1.07 Baseline building cost 12 M Volker Lindenstruth (www.compeng.de) 30. März 2015 Copyright, Goethe Uni, alle Rechte vorbehalten 16

Green Cube Construction started in Dec 2014 On schedule for start of operation in Q4/2015 T. Kollegger AIME Big Data, Budapest 30. March 2015 17

Green Cube T. Kollegger AIME Big Data, Budapest 30. March 2015 18

Green Cube Prototype Two floor prototype in Testinghalle @ GSI Home of current GSI Computing Systems T. Kollegger AIME Big Data, Budapest 30. March 2015 19

GSI Scientific Computing Systems Compute clusters Prometheus ~10.000 cores Kronus L-CSC Storage systems ~4.000 cores + HT ~3.000 cores + 4 GPUs/node (AMD S9150/S10000) Hera ~7 PByte netto (Lustre) Nyx ~5 PByte netto (Lustre) x2 by end of year Used for FAIR&GSI Experiments, ALICE Tier2 & National Analysis Facility, Theory T. Kollegger AIME Big Data, Budapest 30. March 2015 20

GSI Scientific Computing Systems Compute clusters Prometheus ~10.000 cores Kronus L-CSC Storage systems ~4.000 cores + HT ~3.000 cores + 4 GPUs/node (AMD S9150/S10000) Hera ~7 PByte netto (Lustre) Nyx ~5 PByte netto (Lustre) x2 by end of year Used for FAIR&GSI Experiments, ALICE Tier2 & National Analysis Facility, Theory #1 in Green 500 list (Nov 2014) 5,27 GFLOPS/W T. Kollegger AIME Big Data, Budapest 30. March 2015 21

TeraLink Tight integration of LOEWE-CSC Computing Center in Frankfurt (~30km away; 84km in fibres) Router cluster (LNET) for the TeraLink 12 x 10 Gbit Ethernet => lustre IB loadbalancing T. Kollegger AIME Big Data, Budapest 30. March 2015 22

TeraLink lustre clients at Gauss Supercomputer Frankfurt Hera lustre cluster at GSI Reading: 13.5 GB/s Writing: 14GB/s Offloading of jobs to Frankfurt, opportunistic resource usage Additional storage system for selected users in Frankfurt T. Kollegger AIME Big Data, Budapest 30. March 2015 23

Software Stack FairRoot Common Software Framework for Simulation, Reconstruction and Analysis for the FAIR Experiments https://github.com/fairrootgroup/fairroot T. Kollegger AIME Big Data, Budapest 30. March 2015 24

Protocol Buffers BOOST ROOT ZeroMQ CMake Geant4 Genat4_VMC Geant3 VGM???? DDS Building configuraion Testing Fair MQ Fair DB MC Application Module Detector Magnetic Field Event Generator Runtime DB FairRoot and ALFA AliRoot6 (O 2 ) CbmRoot PandaRoot R3BRoot SofiaRoot MPDRoot AsyEosRoot FopiRoot EICRoot ALFA FairRoot Libraries and Tools T. Kollegger AIME Big Data, Budapest 30. March 2015 25

Summary Green Cube Data Center at GSI under contruction PUE < 1.07, low Cap. and Op. Exp Supplemented by Software Development and System Design Program for FAIR Computing T. Kollegger AIME Big Data, Budapest 30. March 2015 26