Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers.

Similar documents
GE Power Controls. MiniFORM Switchboards

P System Cubicles. Certified for more safety

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

PITCHED ROOF STRUCTURES

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Distribution Boards & Consumer Units

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

INSTRUCTIONS: LocknCharge Laptop Carts

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

The complete guide to Low Voltage switchgear

Andersen Electric Window Opener for Andersen Awning and Roof Windows

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

LIEBERT VNSA Installation Sheet

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

AM/FM ANTENNA RELOCATION KIT

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

CDGRD-10. Grounding. Solutions For Comm/Data Applications

R O A D M A S T E R, I N C.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

39HQ Airovision Air Handling Units

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

R O A D M A S T E R, I N C.

MCC Ratings. Voltage Rating

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

EZ-Steer Assisted Steering System

Standard Sleep Pod Side Entry Assembly Instructions

OPERATING INSTRUCTIONS

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

MGB Chrome Bumper Conversion

How To Wire Wireline Cable To A Cell Phone (New Zealand)

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

R O A D M A S T E R, I N C.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

R O A D M A S T E R, I N C.

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Contractors Guide Central Inverter System Installation

These Installation Instructions are valid for antennas in the following version:

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

SHUTTER INSTALLATION INSTRUCTIONS. AUGUST 2006 Version 2

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

Volkswagen B3 Passat Manual Transmission 02A 34 Manual Transmission - Controls, Assembly (Page GR-34) 02A 5-speed. Gearshift cable/lever installing

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

Unified requirements for systems with voltages above 1 kv up to 15 kv

R O A D M A S T E R, I N C.

Quadrant Shower Enclosure. Telephone Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C.

HP 16/18-Port Cable Management Kit Installation Guide

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

FG MOISTURE MONITOR Installation & Operation Manual

AMPSEAL* Automotive Plug Connector and Header Assembly

R O A D M A S T E R, I N C.

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Rating when used as a weight carrying hitch without spring bars:

Expanding a 40-Type Cabinet

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

Triac Printed Circuit Board Replacement

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Advantages of Fixed Circuit Breaker Switchgear

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Toroidal Conductivity Sensor

Installation Manual. BYD Wall-mounted AC Charging Box

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

Page 2 of 6. Fittings Checklist. Care & Maintenance. Additional Tools Required. General Hints & Tips When

Go-kart for little race-drivers

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

Assembly Instruction CAI- Connector with universal Endbell

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &

R O A D M A S T E R, I N C.

Section Grounding and Bonding for Communications

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

5800 Temperature Sensor Cable Assembly

Vehicle Power Install Kit

MCR1900 Media Converter 19-Slot Chassis

CA-6050 Solar Power Unit. User Guide. Designed to work with the Norsonic range of sound level meters to provide a DC supply in remote locations.

with installation dynafact boost GAUGE this manual is for use with systems

Important Information

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Transcription:

Document No. 79001865A RevA Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers. 1 Switch Fuse and Switch Fuse Disconnectors 1.1 Installation Instructions 1.2 Operation and Maintenance 1.3 Voltage Test Points 2 Busbar Chambers for Switch Fuse 3 Fuse Switch and Fuse Switch Disconnectors 3.1 Installation Instructions 3.2 Replacement Fuse Links 4 Busbar Chambers for Fuse Switch 4.1 Busbar cable connections 4.2 Busbar extension kits 4.3 Switch-disconnector busbar connections 4.4 Voltage Test Points 5 Dimensions 5.1 Switch Disconnector Fuse 5.2 Fuse Switch Disconnector 5.3 Busbar chambers Safety The equipment must be installed and maintained by competent personnel in accordance with the appropriate statutory regulations and codes of practice e.g. Electricity at Work Regulations, IEE. Wiring regulations (BS7671) Etc. Ensure the source is isolated elsewhere, locked off and labelled prior to work being carried out on the board. It is the responsibility of the installer to ensure that all electrical connections are tight and satisfactory earth continuity has been achieved. Following completion of installation these instructions should be left with the equipment/end user. 1 Schneider Electric Limited Stafford Park 5, Telford, TF3 3BL Tel: 0870 608 8 608 Fax: 0870 608 8 606 www.schneider.co.uk

1 Switch Fuse and Switch Fuse Disconnectors 1.1 Installation Instructions All wiring should be carefully routed to avoid interference with the switch mechanism. Procedure a. Move operating handle to the OFF position, release the door screw(s) and open the door (which can be lifted vertically off its hinges for easier access) b. Remove transparent line terminal protection cover. c. Mark out and drill fixings on vertical mounting surface to suit internal mounting holes and secure to surface. d. Remove top and bottom gland plates. e. Prepare cable accommodation as required and refit. f. Prepare and connect incoming and outgoing phase and neutral conductors. See table below of tightening torques. g. Ensure unit is free of swarf and wall debris. Rating Phase Connection Earth Bolt Neutral Connection Neutral Link Fuse Links SP&N TP&N Switch Disconnector Switch Disconnector Fuse Maximum Maximum Conductor Size Conductor Size mm Tightening Tightening mm Rigid Flexible Torque Nm Bolt Size Torque Nm Rigid Flexible Tightening Torque Nm Tightening Torque Nm Tightening Torque Nm BS88 Fuse Ref 20A 20A 10 10 2 M6 8 10 10 2 2 2 A1, A2 32A 32A 10 10 2 M6 8 10 10 2 2 2 A1, A2 63A 63A 25 25 3.5 M6 8 25 25 3.5 3.5 2 A2, A3 100A 100A 50 35 3.5 M6 8 50 35 3.5 3.5 2 A2, A3, A4 20A 20A 10 10 2 M6 8 10 10 2 2.5 2 A1, A2 32A 32A 10 10 2 M6 8 10 10 2 2.5 2 A1, A2 63A 63A 25 25 3.5 M6 8 25 25 3.5 3.5 2 A2, A3 100A 100A 50 35 3.5 M6 8 50 35 3.5 3.5 2 A2, A3, A4 125A - 70 50 10 M6 8 70 50 4.5 4.5 - - 160A - 70 50 10 M6 8 70 50 4.5 4.5 - - Connecting the supply Ensure that connection from supply is connected to LINE terminals which are positioned under the incoming terminal screen. Connect the main earth and earth bonding conductors via one of the alternative hole positions in the enclosure using the separately packaged main earth bolt assembly, ensuring the serrated washer is interposed between the earth bolt and enclosure. See Earth Bolt Assembly drawing for fitting details and table for tightening torque. Fit plug to remaining unused bolt hole. Check fuse link ratings and connections. See table for tightening torques. Refit line terminal protective cover and replace door if previously removed. When commissioning tests are satisfactorily completed, ensure door is closed and secure. 1.2 Operation and Maintenance The switch handle can be padlocked in the On or Off position using up to 4 padlocks via the built-in-handle locking lever. When not padlocked the door interlock can be defeated for test purposes by pressing inwards the lever situated directly below the handle locking lever. If this is carried out it should be noted that the device is electrically live. 2

Note: Dimensions for the shackle of the padlock Shackle diameter = 5 to 10mm Check terminals for tightness every 6 months. 1.3 Voltage Test Points Typical Voltage Test Point Label 2.0 Busbar Chambers for Switch Fuse Typical Switch Fuse Busbar Chamber All busbar chambers come with a kit. Each kit contains M8 coachbolts for making the interconnections. Recommended tightening torque 11Nm. 3

3 Fuse Switch and Fuse Switch Disconnectors 3.1 Installation Instructions a. Ensure operating handle is in the Off position, release door-fastening screw and open the door. The door may be lifted off its hinges for ease of access. b. To access terminals; remove the clear protective barriers. c. To install cables, remove the gland plate and fit cable extension box (if required) using the screws removed from the gland plate. For ease of cable access, the cross rails of the enclosure may be removed. d. Install cables and tighten bolts in accordance with the following torque settings. 100 and 160A frame 25Nm 250, 400, 500 and 630A frame 40Nm e. Replace cross rails and protective barriers. The mouldings should not be dismantled for any reason. 3.2 Replacement Fuse Links Rating 100A 160A 200A 250A 315A 400A 500A 630A BS88 Reference B1 111mm B2 111mm B2 111mm B3/B4 111mm C1 133mm C1 133mm C2 133mm C2 133mm 4 Busbar Chambers for Fuse Switch Typical Fuse Switch Busbar Chamber The busbar chambers allow traditional wall mounted electrical distribution equipment to be built up to suit each application. Connections are available to join most combinations of components to give a rigid, fault rated assembly. 4

4.1 Busbar Cable Connections To enable crimped cable ends to be connected to the busbar chamber bars. (Fig 1). Fig 1 Kit contents: 8 x busbar clamps, 4 x M10 bolts, nuts, plain and spring washers. Tightening torque: 40Nm for all ratings. a. Pass fixing bolt with one busbar clamp through the busbars from behind. b. Place second busbar clamp over bolt and locate on top of the busbars. c. Position cable lug onto bolt and secure using nuts and washers to the torque detailed. 4.2 Busbar Extension Kits To electrically and mechanically join busbar chambers. Fig 2 Kit contents: 200-400A: 4 x busbar links, 8 x busbar clamps, 8 x M10 bolts, nuts, plain and spring washers, 6 x M8 bolts, nuts and washers. 400-630A: 8 x busbar links, 8 x busbar clamps, 8 x M10 bolts, nuts, plain and spring washers, 6 x M8 bolts, nuts and washers. Tightening torque: 40Nm for all ratings. Fig 3 a. Remove end covers from busbar chambers to be joined. b. Position busbar chambers together and secure together using M8 fixing bolts (Fig 2). c. Place flat washer and insulated copper, if 600-800A rating onto bolt and pass the bolt between the busbars. d. Place copper link on top of the bars. Fit flat spring washers and nuts onto fixing bolts and tighten to the specified torque. e. Refit covers when all other connections made. 4.3 Switch Disconnector Busbar Connections To electrically connect switch-disconnetor to the busbars. Fig 4 Fig 5 Kit contents: 4 copper connections, front and rear insulated barriers, M5 screws, plain and spring washers, busbar clamps, M10 nuts, bolts and washers (Fig 3). Note: the busbar chambers should always be mounted securely before switch units and other accessories are fitted. a. Remove door, gland plate and terminal shields from switch unit and covers from the busbar chamber. b. Using the two insulated barriers as a template mark the fixing holes for the switch unit on the top cover of the busbar chamber keeping the units flush at the rear. c. Use the switch unit to mark the positions of the wall fixings. d. Drill holes previously marked and then loosely secure the switch unit to the wall. e. Place the notched insulation shield between the switch unit and the busbar chamber, towards the rear and loosely fit the rear fixing bolts. 5

Fig 6 Fig 7 f. Remove terminal bolts from the switch unit and fit the copper connections between these terminals and the busbars ensuring correct phase alignment, using the M10 bolts, nuts and washers. Leave connections loose (Fig 4 & 5). g. Slide the front insulation shield between the busbar chamber and the switch unit. Fit remaining bolts to secure the switch unit to the busbar chamber and the wall. The insulation sheets should now provide a complete shield between the two units (Fig 6). h. For 315-800A units the gland plate removed earlier must be cut to fill the space between the front of the busbar chamber and the switch unit using the existing fixing holes. i. Cut the busbar chamber cover to length to cover all apertures in the busbar chamber (Fig 7). j. Tighten all mechanical fixings between units and to the wall. k. Tighten all electrical connections to the required torque of 40Nm for all ratings. l. Refit terminal shields and doors to the units and covers to the busbar chamber. 4.4 Voltage Test Points Typical Voltage Test Point Label 6

5. Dimensions 5.1 Switch Disconnector Fuse All dimensions in mm Rating A B C D E F G H J 20A 210 240 105 160 50 51 44 20 25 32A 210 240 105 160 50 51 44 20 25 63A 235 350 105 270 55 51 50 32 32 100A 260 400 120 320 65 51 60 40 40 125A 292 521 121 421 94.5 51 60 40 40 160A 292 521 121 421 94.5 51 60 40 40 5.2 Fuse Switch Disconnector All dimensions in mm Rating A B C D E F G H J K L 63A 380 292 200 260 130 81 142 226 100 292 200 100A 380 292 200 260 130 81 142 226 100 292 200 160A 380 292 200 260 130 81 142 226 150 292 200 200/250A 380 340 200 260 180 81 142 274 180 340 200 315/400A 455 489 270 335 289 100 212 423 300 489 270 500A 455 489 270 335 289 100 212 423 300 489 270 630A 455 489 270 335 289 100 212 423 400 489 270 800A 455 489 270 335 289 100 212 423 400 489 270 7

5.3 Switch Fuse and Switch Fuse Disconnector Busbar Chambers All dimensions in mm Reference Rating A B C SBC106 160A 600 350 120 SBC109 160A 900 350 120 5.4 Fuse Switch and Fuse Switch Disconnector Busbar Chambers All dimensions in mm Rating A B A B A B For 750 long For 1200 long For 1800 long 200A 750 670 1200 1120 1800 1720 400A 750 670 1200 1120 1800 1720 630A 750 670 1200 1120 1800 1720 800A 750 670 1200 1120 1800 1720 8