Sartorius Basic ph Meter PB-20

Similar documents
UltraBasic Benchtop ph Meter Operation Manual

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

ExStik TM ph Waterproof Meters

ph Measurement and Control

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

USEPA Electrode Method Method 8156

SenTix 950 SenTix 980

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

ph 200 ph-/redox-/temperature Meter Operating instructions

Care and use guide. Contents. a handy solution made easy. page

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

Milwaukee USER MANUAL

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

ph Measurements of Common Substances

Portable Waterproof ph/dissolved Oxygen Meter

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Operating Instructions

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

ph and Acidity in Wine and Fruit Juice

Duct Humidity Transmitter

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

AXIS T81B22 DC 30W Midspan

EPSON USB/Parallel Adapter User s Guide

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

BTX180 Wireless Bluetooth Speaker

Features, Limitations & Potential Errors

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

PN /rev. D December Theory and Practice of ph Measurement

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Measurement by Ion Selective Electrodes

User Manual USB Laptop KVM Switch. GCS661U Part No. M1069

PrintPAD CN3/4/3e/4e. User Guide

Refer to page 6 to page 19 for detailed instructions.

USB VoIP Phone Adapter. User s Manual

CONSOLE REMOTE I /O AC 9V

USB Scrolling Optical Mini Mouse

Point of View Mobii 10 Tegra Tablet. Notice... 2

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

PS/2 KVM Console Extender User Manual (GCE250)

Model 4510 Conductivity/TDS Meter Operating Manual

ph Test #1: Scaling Common Liquids (From a series of 5)

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

IP Box Camera ACM Ver Hardware User s Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

4.3-inch Back-Up Camera

GA/7 Potentiometric Titration

Care and use guide. soil ph meter. Contents. page

Global Water Instrumentation, Inc.

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

Care and use guide. Contents. a handy solution made easy. page

DISSOLVED OXYGEN PROBE

Model UT713 OPERATING MANUAL

Instruction Manual Temp 4/5/6 Temperature Meter Series

USB KVM Console Extender User Manual (GCE700)

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

Wireless Indoor/ Outdoor Thermometer

Bluelab Soil ph Meter Instruction Manual

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Wireless Optical Mouse

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

Experiment 4 (Future - Lab needs an unknown)

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

USER GUIDE. Access to the Server is via the following webpage:

Ground Resistance Clamp On Tester

ph and Acidity in Tomato Sauce

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has

Drop Counter Sensor Product Number: ENDRP-AD100

User Guide for the Wireless Headset (HS-11W) Issue 1

Wave/PC Interactive System USB Adapter Kit. Installation Guide

Instant Ear Thermometer

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

BCS1 Bluetooth Aux Car Adapter Kit

StructureScan HD Module. Installation Guide ENGLISH

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

General Purpose ph/orp Sensors

MiniView Micro USB Plus

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

ES-CAM2A IP Camera.

Kinivo 301BN HDMI Switch

Thermistor Thermometer MODEL NO

Transcription:

98648-009-18 Sartorius Basic ph Meter PB-20 Operation Manual

Contents Page General View 4 Warning and Safety Information 5 Basic ph Meter Quick Reference 6 Installing and Maintaining Electrodes 8 Standardizing for ph Measurement 10 Using Setup 14 Standardizing for Millivolt Measurement 16 Measuring ph or Millivolts 18 Understanding ph Theory 20 Measuring ph 21 Troubleshooting 22 Meter Specifications 24 Accessories 25 C Marking 26 3

General View Digital Display Stability Icon ph/mv press to toggle between ph and mv mode Standardize press to enter each buffer Enter press to select options Setup press to clear buffers, review electrode calibration or select new autorecognized buffers 1. Front Panel Controls 2. Digital Display S 100.0 C %slope rel mv ph -18.0.0.0 Good Electrode Error FET Standardizing Clear Measuring Set Buffers 2 4 7 10 12 1 3 5 8 10 13 1.68 4.01 6.86 9.18 12.46 1.08 3.06 4.86 6.79 9.23 12.76 Operation Icons Electrode Check Icons Temperature Buffer Icons Mode Result Prompts FET Electrode Connector ATC (Automatic Temperature Compensation Probe Connector AC Adapter Power Cable Connector power ref input FET ATC power ref input FET ATC Reference Electrode Connector (used with separate Reference Electrodes) BNC Glass ph or Ion Electrode Connector Power Connector 3. Rear Panel Connectors 4. Connecting to a Power Source 4

Warning and Safety Information For safety and operating reasons, only authorized service technicians may open the Basic Meter PB-20 housing. Therefore, only authorized technicians may repair or perform maintenance on this ph meter. Any tampering with the ph meter or negligent or intentional damage to this equipment will void any warranty claims against the manufacturer. If liquid gets into the ph meter, unplug it from AC power (mains supply) and have an authorized service technician check the ph meter. If you do not plan to use this ph meter for a relatively long period, please disconnect it from AC power. For safety reasons, use this equipment only for the application described in this operation manual. Make sure that the buffers used for standardizing have exactly the same values that are stored. Information on Radio Frequency Interference Warning! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference, when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. 5

Basic ph Meter Quick Reference 1. Connect power cable to meter power jack and to AC power source. power ref input FET ATC power ref input FET ATC 2. Connect a glass ph electrode to the input and ATC connectors, or connect the FET ph electrode to the FET connector. rel mv ph 3. Press ph/mv until the display indicates the appropriate measurement mode (ph or mv/relative mv). 4. Standardize the meter using up to three buffers by immersing the electrode in a buffer, stirring, then pressing Standardize to enter each buffer. Standardizing 6

S 5. The display shows the current reading in ph, mv, or relative mv units. Measuring %slope 6. Press Setup to review electrode calibration and to clear or select buffer sets. Clear Set Buffers 7

Installing and Maintaining Electrodes This PB-20 meter allows you to use two types of ph electrodes: a glass ph electrode and the FET (field effect transistor) ph/atc electrode. If both types of electrodes are installed, the meter will read the FET electrode. Note: If both electrodes are connected to the meter, do not put them in a solution together because you will get inaccurate measurements. 1. Remove the protective end cover from electrode. 2. Before first use of your glass ph electrode, or whenever the electrode is dry, soak over night in an Electrode Filling Solution, KCI solution or Electrode Storage Solution. power ref input FET ATC 3. Remove the shorting cap on the BNC connector. Install the combination glass ph/atc electrode by plugging it into the input connection (push on and twist to lock) and the ATC connector into the ATC jack. 8

power ref input FET ATC 4. Option: Install the optional FET ph/atc electrode by plugging it into the FET jack on the back of the meter panel. Allow the FET electrode to stabilize for one minute prior to use. power ref input FET ATC ISE 5. Option: Install ORP or Ion Selective Electrode pairs by removing the BNC shorting cap and plugging the BNC connector (twist-lock) into the BNC jack. If a separate reference electrode is used, plug the reference electrode into the ref pin. Reference Electrode 6. Rinse and blot-dry electrodes between each measurement (do not wipe). Rinse electrodes with distilled water or deionized water, or part of the next solution to be measured. 7. Store glass ph electrodes in Electrode Filling Solution, KCI solution or Electrode Storage Solution. Always leave the filling hole open and refill with Filling Solution when the internal solution level gets low. Store FET ph/atc electrodes dry. 9

Standardizing for ph Measurement Because electrodes vary in their response, you must standardize your ph meter and electrode to compensate for electrode variation. The more frequently you standardize, the more accurate your measurements. Standardize daily, or more often, for accurate results. This ph meter allows automatic standardization using up to three buffers. When you enter a fourth buffer, the buffer farthest away is replaced by the new buffer ph. The ph meter performs automatic temperature compensation. 1. Immerse electrode in a buffer solution. Stir gently. Allow the electrode to reach a stable value. Setup Enter BASIC ph 4.12 2. Press and release the ph/mv button until your digital display indicates ph mode. This button toggles between ph and mv modes. ph Clear Buffers 3. Clear existing buffers when doing a new 2 or 3 point standardization. Use the Setup and Enter buttons to clear existing buffers and to select a new set of buffers. See page 13 14. 10

ph 4.00 Standardizing 4 4. Press Standardize. The meter recognizes the buffer and flashes a buffer icon. When the signal is stable, or when you press Enter, the buffer is entered. %slope 100.0 4 5. The meter displays the %slope of the electrode as 100.0%. On entering a second or third buffer, the meter performs a diagnostic check on the electrode and displays the slope. ph 7.00 Standardizing 4 7 6. To enter a second buffer, place the electrode in the second buffer solution, stir, allow time for the electrode to stabilize, and press Standardize again. The meter recognizes the buffer and displays the first and second buffer icons. %slope 99.4 Good Electrode 4 7 7. Next, the meter performs a diagnostic test of the electrode. The display indicates either Good Electrode or Electrode Error. The meter displays the %slope of the electrode. 11

%slope 82.3 Electrode Error 4 8. Electrode Error indicates that your electrode is not working properly. The electrode response must be between 90 and 105% slope. Measurements causing Electrode Error are not accepted, used or stored by the meter (see Troubleshooting on page 22). Press Enter to clear the Error, then try re-entering the buffer as described in step 6. ph 10.00 Standardizing 4 7 10 9. To set a third standard, place the electrode in the third buffer solution, stir, allow to stabilize, and press Standardize. The results will be the same as in steps 7 and 8, except the display will show three buffer icons. 22.5 C ph 10.03 Standardizing 4 7 10 10. After entering each buffer, the Standardizing icon goes off and the Measuring icon appears on the display to indicate that the meter returns to Measuring operation. Note: The meter continually adjusts for temperature. Therefore, buffers may vary slightly from the nominal values because of temperature. 11. Standardize your meter and electrode using at least two buffers with ph values bracketing the expected ph of your samples. Stirring with a magnetic stir bar and stirrer provides faster electrode response. 12

25 C Set Buffers 2 4 7 10 12 12. The first set of buffers in the meter is used at 25 C in North America and, typically, at 20 C in Europe. In ph mode, press Standardize and Setup together to show the current buffer temperature setting. Press both Standardize and Setup again to toggle between the temperature settings. Press Enter to select the displayed temperature setting and to return to Measuring. 13

Using Setup ph Clear Buffers The Setup button lets you clear all the buffers that you have entered, review calibration information, or select the buffer set that you want. Note: You can escape the setup mode at any time by pressing ph/mv. 1. Press Setup and the meter displays a flashing Clear Buffers icon. Use this step only when you wish to clear all buffers you have entered. To clear all existing buffers, press Enter. The meter clears all buffers and returns to Measuring. %slope 99.4 Good Electrode 4 7 2. Press Setup again to show electrode performance. If the meter has accepted two buffers, it will display Good Electrode, display the slope between the first and second buffers and display the two buffer icons. %slope 98.7 Good Electrode 7 10 3. Pressing Setup again shows the electrode slope between the second and third buffers (if three buffers have been entered) and shows the second and third buffer icons. 14

ph 4. Press Setup again to display a flashing Set Buffers icon and to display the first buffer set icons. Set Buffers 2 4 7 10 12 ph Set Buffers 1 3 5 8 10 13 5. Press Enter to select the set of buffers shown on the display or Press Setup again to view the next set of buffers. Continue pressing Setup to view the third and fourth buffer sets. ph Set Buffers 1.68 4.01 6.86 9.18 12.46 6. Press Enter to select the displayed buffer set that contains the buffer you want to use. Press Setup again, or press ph/mv at any time, to return to Measuring. Note: You may mix buffers from different sets. 15

Standardizing for Millivolt Measurement (Relative Millivolts) You use millivolt measurement for determining ion concentration and for measuring redox potential (also called ORP, oxidation reduction potential). You will normally use an ion selective electrode (ISE), combined with a reference electrode, to measure ion concentration. The ISE senses the ion concentration and responds with a millivolt potential. The millivolt readings are then used to determine ion concentrations. You will normally use a platinum indicator electrode, combined with a reference electrode, to measure redox potential (ORP). ORP measurements indicate the oxidizing or reducing capability of a solution. You can use ORP values to monitor or control solutions requiring a set amount of oxidants or reductants. 1. Immerse electrode in a standard solution. Setup Enter BASIC mv 100.0 2. Press the ph/mv button until your digital display indicates mv mode. 16

mv 100.0 Standardizing 3. Press Standardize to enter a mv standard and read relative mv. Note: Relative mv mode is not allowed with the FET electrode. rel mv 0.0 Measuring 4. When the signal becomes stable, or when you press Enter, the current absolute mv value becomes zero relative millivolts. rel mv 100.0 Clear 5. To clear a mv offset and return to absolute millivolt mode, press Setup. The meter displays a flashing Clear icon, and shows the current relative millivolt offset. mv 6. To clear the mv standard, press Enter. You then return to absolute mv mode. Measuring 17

Measuring ph or Millivolts 1. Standardize your meter. See page 21(pH) or page 16 (mv). Standardizing 2. Rinse electrode and immerse in sample solution. Stir gently. rel mv ph 3. Press ph/mv until your display indicates the correct mode (ph, mv or relative mv). S Measuring 4. The display shows the current reading in ph, mv, or relative mv units. When the signal is stable, the meter displays the S icon. The S icon means the signal is changing less than 0.007 ph or 0.08 mv from the prior reading. 18

rel mv ph Err Electrode Error Measuring 5. You may receive an out of range error, Err, if your electrode is not immersed in a solution. To correct the error, immerse the electrode in a solution. power ref input FET ATC 6. Separate calibrations for the glass and FET electrodes are stored in memory. Plugging the FET in recalls its calibration; unplugging the FET recalls the glass electrode calibration. 19

Understanding ph Theory Defining ph The measurement of ph plays an important role in identifying and controlling acidity and alkalinity levels for industry and research. ph is a measure of the acidity or alkalinity of a solution and can be represented by this equation: ph = -log [H + ] with [H + ] representing the concentration of hydrogen ions in the solution. ph is sometimes referred to as the power of the hydrogen ion in a solution. By using a ph meter, you can determine exact ph levels of solutions. For example, rather than say that lemon juice is quite acidic, you can say that lemon juice has a ph of 2.4. An exact ph value can be used to control or measure acidity levels for manufacturing processes or for basic research. ph values generally range from 0 to14, with a ph value of 7 being the neutral point, or the value of pure water. ph values greater than 7 represent increasing alkalinity, whereas ph values below 7 represent increasing acidity (Figure1). Neutral Strong Acid Lemon Juice Tomato Juice Coffee Pure water Baking Soda Ammonia Strong Base Figure 1. 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 more acidic ph ph Scale showing the relative acidity or basicity of some common substances. more basic

Measuring ph To measure ph with a conventional glass ph electrode, the meter uses a phsensing glass bulb that is sensitive to hydrogen ions. The potential developed at the glass membrane is directly related to the ph of the solution. The glass electrode is paired with a reference electrode which completes the electrical measuring circuit and provides a stable reference point. These two electrodes are joined to create a combination electrode. The combination glass electrode is connected to the ph meter which reads the voltage, converts it to ph units, and displays the result. Porous Junction ATC Temperature Sensor ph Sensor Reference Electrode Combination Glass ph Electrode This meter can also use the Field Effect Transistor (FET) electrode for measuring ph. The FET uses an ion-sensitive solid state membrane attached to the transistor to measure the hydrogen ion concentration of a solution. The FET is paired with a reference electrode that maintains a constant potential while the FET responds to the sample. ph-sensitive FET ATC Temperature Sensor Reference Electrode 21

Troubleshooting Err Electrode Error 1. If the signal from the electrode is out of range, the display will show Err. This may happen when the electrode is not in a solution. Electrode Error 2. The meter will display Electrode Error when it detects an error in electrode response. During standardization, the message indicates that the electrode is less than 90% or more than 105% of the correct response. The Electrode Error message can indicate either a bad electrode or bad buffer(s). Error Err C 3. If the meter detects an error in the temperature probe, the display shows Err C. If you do not use a temperature probe, the meter uses the default temperature that you set, either 20 C or 25 C. Electrode Test ph 7 0 ± 30 mv ph 4 169 to 186 mv more than ph 7 ph10 159 to 185 mv less than ph 7 4. To test the ph electrode, place it in a good ph 7 buffer. Press ph/mv to use the mv mode, and note the millivolt reading. Make sure the meter is in mv mode and not relative mv mode. Repeat for either a ph 4 or ph 10 buffer. The electrode signal must be within the limits shown below (when temperature is near 25 C). 22

power ref input FET ATC 5. To test the meter for correct operation, install the BNC (input) shorting cap. Press ph/mv to select the mv mode, and note the mv reading. Make sure the meter is in mv mode and not relative mv mode.if the meter reads 0 ± 0.3 mv, it is measuring correctly. Note that a long-term drift of 0.1 mv/month since last calibration is specified. Cal Error 6. If the meter detects a loss of calibration or a hardware error during its power-up self-test, the display shows CAL Error. This means the mv accuracy may be reduced, but ph accuracy after standardization will be the same. Press Enter to continue using the meter. 23

Meter Specifications ph 1.99 to 19.990 displayed to 0.010 accurate to ±0.005 mv 1800.0 to 1800.0 mv displayed to 0.1 mv accurate to ±0.3 mv Temperature 5.0 to 105.0 C displayed to 0.1 C accurate to ±0.4 C Standardization 0, 1, 2 or 3 buffers Auto buffer recognition 22 buffers 2, 4, 7, 10, 12 1, 3, 6, 8, 10, 13 1.68, 4.0, 6.86, 9.18, 12.46 1.09, 3.06, 4.65, 6.79, 9.23, 12.75 Auto Temperature Compensation (ATC) Automatic electrode slope correction for 90 105% Direct reading with both a glass and FET ph electrode 24

Accessories You can order the following accessories for your ph meter: Plastic-body ph/atc Electrode, with built-in temperature sensor 3mol/l KCI liquid-filled Glass body ph/atc Electrode, 3mol/l KCI liquid-filled, platinum junction Plastic body ph Electrode, gell-filled Glass body ph Electrode, platinum junction FET ph/atc Electrode, with built-in temperature sensor ATC Temperature Probe PY-P10 PY-P11 PY-20 PY-21 PY-P30 PY-T01 Other electrodes, such as ion selective electrodes and redox electrodes are also available. Call your sales representative. 25

C Marking The C marking affixed to the equipment indicates that the equipment meets the requirements of the following Directive(s): Council Directive 89/336/EEC Electromagnetic compatibility (EMC) Applicable European Standards: Limitation of emissions: EN 50081-2 Industrial environment Defined immunity to interference: EN 50082-1 Residential, commercial and light industry EN 50082-2 Industrial environment Warning This is a Class A device that can cause radio interference in residential areas. If this should occur, the user may be required to take suitable measures to correct and eliminate such interference, and to pay the costs incurred as a result. Important Note: The operator shall be responsible for any modifications to Sartorius equipment and for any connections of cables or equipment not supplied by Sartorius and must check and, if necessary, correct these modifications and connections. On request, Sartorius will provide information on the minimum operating specifications (in accordance with the Standards listed above for defined immunity to interference). Council Directive 73/23/EEC Electrical equipment designed for use within certain voltage limits Applicable European Standards: EN 60950 Safety of information technology equipment including electrical business equipment EN 61010 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements If you use electrical equipment in installations and under ambient conditions requiring higher safety standards, you must comply with the provisions as specified in the applicable regulations for installation in your country. 26

Sartorius AG b 37070 Goettingen, Germany p Weender Landstrasse 94 108, 37075 Goettingen, Germany t (+49/551) 308-0, f (+49/551) 308-3289 Internet: http://www.sartorius.com Copyright by Sartorius AG, Goettingen, Germany. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG. The status of the information, specifications and illustrations in this manual is indicated by the date given below. Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. Status: June 2000, Sartorius AG, Goettingen, Germany Printed in Germany on paper that has been bleached without any use of chlorine W3A000.Basic ph meter PB-20 KT Publication No.: WPB6001-e00062