W-BT ESCALATOR INSTALLATION GUIDE BOOK NOTICE 1) This guidebook is for the use of mechanical part of W-BT Type Escalators Only. 2) This guidebook does not cover safety related subjects. 3) Contact us for your detail queries which this guidebook dose not cover.
CONTENTS 1. GENERAL 1 2. PIT & WELLWAY CHECK 5 3. TRUSS JOINING & HOISTING 6 4. INTERMEDIATE SUPPORT BEAM WORK 7 5. TRUSS WIRING.FIRST RUNNING TEST & STEP INSTALLATION 8 6. PANEL SUPPORT EXTRUSION INSTALLATION 9 7. OUTER DECK INSTALLATION 11 8. GLASS PANEL INSTALLATION 12 9. HANDRAIL FRAME INSTALATION 13 10. HANDRAIL & RETURN GUIDE INSTALLATION 15 11. SKIRT PANEL INSTALLATION 18 12. SECOND RUNNING TEST& SWITCH ADJUSTMENT 19 13. INNER DECK INSTALLATION 20 14. NEWEL SKIRT INSTALLATION 21 HYUNDAI ELEVATOR CO., LTD.
1. GENERAL W-BT ESCALATOR INSTALLATION GUIDE BOOK 1.1 INSTALLATION PROCEDURE JOBSITE ARRIVAL TRUSS FIRST RUNNING PIT & WELL INSTALLATION TEST & STEP WAY CHECK & LEVELING INSTALLATION TRUSS JOINT & (INTERMEDIATE SUPPORT AXLE CHAIN SUPPORT BEAM EXTRUSION JOINT INSTALLATION) INSTALLATION OUTER DECK HANDRAIL FRAME HANDRAIL SKIRT PANEL INSTALLATION INSTALLATION INSTALLATION INSTALLATION GLASS INSTALLATION GUIDE STRIP INSTALLATION SWITCH ADJUSTMENT & SECOND RUNNING TEST INNER DECK INSTALLATION NEWEL SKIRT INSTALLATION TEST RUNNING Figure 1.1 Escalator installation procedures HYUNDAI ELEVATOR CO., LTD. - 1 -
1.2 ESCALATOR MAJOR COMPONENTS Figure 1.2 Escalator major components HYUNDAI ELEVATOR CO., LTD. - 2 -
1.3 BALUSTRADE DIMENSION Figure 1.3 Escalator section Figure 1.4 Sample balustrade part dimension drawing HYUNDAI ELEVATOR CO., LTD. - 3 -
For actual job site dimension, refer to the balustrade parts dimension drawing which is contained in each escalator shipment package. Figure 1.5 section dimension of escalator HYUNDAI ELEVATOR CO., LTD. - 4 -
2. PIT & WELL WAY CHECK Check the job site to install escalator by referring layout drawing and actual site dimension such as rise, wellway length, pit depth, base plate size, etc. Figure 2-1 Typical Truss and Wellway Layout Figure 2-2 Typical Layout Check Check the Base Plate location and Welding condition. Prearrange below with the General Contractor before starting installation ; 1 Temporary Power Supply. 2 Storage Area. 3 Access to the building for Truss & Overhead support for hoisting Truss assembly. HYUNDAI ELEVATOR CO., LTD. - 5 -
3. TRUSS JOINING & HOISTING 3.1 TRUSS JOINING Join truss by aligning and bolting "match holes" which is already drilled from our factory. Make sure that shim plate shall not be slipped out while joining truss. Figure 3-1 Truss joining 3.2 AXLE CHAIN ASSEMBLY Join the axle chain by joining lower part of chain first and then upper part of chain by using chain block with some force. NOTICE: Always use brand-new split pin. Never use even once used split pin. Figure 3-2 Step chain jointing Figure 3-3 Truss moving HYUNDAI ELEVATOR CO., LTD. - 6 -
3.3 TRUSS HOISTING & LEVELING Hoist truss horizontally to prevent twist or damage of truss. Adjust truss angle, floor finish line of building and floor plate with maintaining the horizontal level at 4 (four) parts such as support angle, floor plate, W.P.(Working point)and step by using truss-leveling bolt. Insert shim between base plate and support angle, then weld base plate by using angle to fix truss as shown on Figure 3-5. NOTICE: Weld angle after installing Intermediate support beam, if Intermediate support beam is required. Figure 3-4 Floor leveling Figure 3-5 Truss base plate work NOTICE : Handrail will be worn out or slanted, if there are level difference between left and right hand side of Truss after truss installation. 4. INTERMEDIATE SUPPORT BEAM WORK Install intermediate support beam to prevent from sagging of Truss, if intermediate support beam is shown on layout drawing. Weld and install support beam. (Figure 4-1) HYUNDAI ELEVATOR CO., LTD. - 7 -
Figure 4-1 Intermediate support beam work 5. TRUSS WIRING, FIRST RUNNING TEST & STEP INSTALLATION 5.1 TRUSS WIRING Connect the cables in the upper truss to the cables (or junction box) in the lower truss. Test all the pre-installed safety switches and emergency stop switch. 5.2 FIRST RUNNING TEST Do the first running test. 5.3 STEP INSTALLATION NOTICE : Step installation or step removal can only be done at the inclination part of escalator. Figure 5-1 Step Installation & removal HYUNDAI ELEVATOR CO., LTD. - 8 -
6. PANEL SUPPORT EXTRUSION INSTALLATION NOTICE: Adjust length [X] of mounting clamp assembly. (Figure 6-1) Install Panel Support Extrusion from the lower part. Adjust length [A] of panel support extrusion by bolting. (Figure 6-2) Check whether panel support extrusion is horizontal or not and then adjust it to be leveled by using machinist level. (UNIT: mm) 800TYPE FOR 606 FOR 588 STEP STEP 1000 TYP E 1200 TYPE [X] 427.5 436.5 536 636 Figure 6-1 adjustment Mark joint line of inner & outer deck and glass panel. (Figure 6-2) ESCALATOR DEGREE (UNIT: mm) [A] [B] [C] 30 477 220 903 Figure 6-2 Marking joint line of inner & outer deck and glass panel NOTICE: If the level of mounting clamp is all different, glass lining-up work will not be easy. Moreover, glass will be shaken and frictional resistance of inner surface of handrail will be increased. HYUNDAI ELEVATOR CO., LTD. - 9 -
Figure 6-3 Panel support extrusion installation HYUNDAI ELEVATOR CO., LTD. - 10 -
7. OUTER DECK INSTALLATION Install a splice plate into the upper end of the lower curve deck. (Figure 7-2) NOTICE: In case of parallel installation, the outer deck at the middle part shall be assembled first. Fasten bolts securely and finish all outer deck installation works before taking next step. NOTICE: Overall clearance between the tops and bottoms at the joint of two units of escalators shall be same. Figure 7-1 Outer deck installation Figure 7-2 Outer deck splicing Figure 7-3 Mounting clamp HYUNDAI ELEVATOR CO., LTD. - 11 -
909.7 909.7 W-BT ESCALATOR INSTALLATION GUIDE BOOK 8. GLASS PANEL INSTALLATION 3 3 23 23 573 2 22 2 22 1 1 21 21 1380 Figure 8-1 Glass panel installation *REMOVE AFTER GLASS SETTING SHIM (3mm) 2 GLASS 2 mm PANEL SUPPORT EXTRUSION JOINT 1 GLASS GLASS JOINT LINE Figure 8-2 3mm shims between glasses Figure 8-3 Glass panel section NOTICE: Install a Glass vertically. Adjust high and low, left and right side width of handrail return guide. Assemble a Glass accurately starting from bottom curve by setting the W.P. as standard. Adjust 3mm gap for top and bottom part of joint of adjacent glasses by pre-assembling variable glass. Check whether Glass is being installed vertically or not by using machinist level. Assemble top curve glass finally and then inspect vertical & horizontal level once more. Readjust it by using mounting clamp, if required. NOTICE: Two pieces of roughly 1/8" (3mm) thick padding will maintain space of panels until all the glasses are installed and then shims will be removed. Leave 1/8"(3mm) gap between each panels. NOTICE: Maintain 3mm space between glasses. In case of 3mm gap is not maintained then handrail tension will be affected. HYUNDAI ELEVATOR CO., LTD. - 12 -
9. HANDRAIL FRAME INSTALLATION 9.1 NEWEL HANDRAIL FRAME Remove joint bars from the ends of the plastic handrail return guides and bolt them onto the lower ends of the handrail newel guides. Slip the lower newel guide onto the newel panel, and insert the joint block (with four holes) to connect the newel with the panel support extrusion. Drill holes into the newel to align with the holes in the joint block, and insert the connecting bolts Figure 9-1 Newel frame assembly Figure 9-2 Newel frame fixed HYUNDAI ELEVATOR CO., LTD. - 13 -
9.2 HANDRAIL FRAME Inspect the gripper to make sure that it is fully seated on the panels. Install lower curve handrail guide on the gripper. Figure 9-3 Handrail frame assembly Install upper curve handrail guide on the gripper. The holes for the splice block for the last piece must also be drilled. Carefully measure and cut the last handrail guide piece to the required length. Figure 9-4 Cut the variable Handrail frame NOTICE: Cut 30-40mm surplus part of variable handrail frame as shown on Figure 9-4 while assembling variable handrail frame. NOTICE: Readjust glass installation condition, if cutting part is out of the range of 30-40mm. HYUNDAI ELEVATOR CO., LTD. - 14 -
9.3 GUIDE STRIP INSTALLATION (ONLY FOR ALUMINIUM FRAME) NOTICE: Do not splice Handrail Guide Strips. Figure 9-5 Guide strip installation Figure 9-6 Trimming ends of guide strip 10. HANDRAIL & RETURN GUIDE INSTALLATION 10.1 PRELIMINARY SETUP Figure 10-1 Return guide installation Figure 10-2 Do not handrail bent Figure 10-3 Section of return guide HYUNDAI ELEVATOR CO., LTD. - 15 -
NOTICE : Thoroughly clean debris, especially along the path of the handrail, inside of aluminum and plastic handrail guides. NOTICE : Upper curve handrail return guide shall not be getting resistance. 10.2 HANDRAIL INSTALLATION & ADJUSTMENT 1) Handrail guide system Confirm the return guide is located so there is enough clearance for the handrail under the guide and between the guide and truss. Install the newel return guide as following handrail adjusting guide. (Figure 10-4) 1 Line up disconnected part of return guide and adjusting guide. Mark and cut adjusting guide 12mm below the point where guides over lap. 2 Install handrail on remaining adjusting guide. 3 Temporarily connect guides with Inner splice bar. Install outer splicing bar on return guide, and tighten bolts. The outer splice bar on the adjusting guide is not installed until step 7 mentioned below, so that the inner splice bar is free to move while the adjusting guide is adjusted. 4 700mm below splice, lift adjusting guide and handrail up toward top of balustrade. On inner splice bar, mark end of adjusting guide. Release handrail and adjusting guide. (Figure 10-4) 5 700mm below splice, push adjusting guide and handrail down away from balustrade. On inner splice bar, mark end of adjusting guide. Release handrail and adjusting guide. (Figure 10-4) 6 Find the midpoint of tension marks made by push adjusting guide up and down. Adjust adjusting guide that the end of adjusting guide is located at midpoint of tension marks. Attach outer splice bar on adjusting guide and tighten bolts. Figure 10-4 Handrail tension adjustment HYUNDAI ELEVATOR CO., LTD. - 16 -
2) Installation of handrail system Handrail system is subassembly with circular moving handrail, which is supported for holding by passenger. Because of limit of transportation, subassemblies of handrail system are not convenience to install on the escalator (except special). Handrail system assembling is divided to two times to finished. in the first time, debugging checking and remove to park are finished in workshop, the second installation will be finished on building site, which is a systemic engineering. See the appendix installation drawing. Handrail system are composed of handrail driver guide panel handrail handrail entry device skirt panel inner and outer deck and top and bottom turning parts. The handrail in the handrail system is a motional parts for holding by passenger, which speed should be accordance with speed of step,and should be ahead of step for 0-2.0%, Which can be done by adjusting handrail drivers. Handrail driving system is a subassembly to drive handrail to move circularly (Figure 10-5). Figure 10-5 Handrail drive 1 Tension screw 2 Press tape 3 Friction wheel 4 Handrail 5 Tension rod 6 Screw 7 Locknut 8 Nut 9 Press spring Handrail are drove by friction wheel (3) with rubber tire, tension of handrail (4) may be done by adjusting the nut 8 on the tension rod, and press handrail with press tape (4), tension of press tape is adjusted with tension screw. Tension force of handrail and press tape should be proper, and friction wheel will drive handrail normally, at this time, it will take more strength to stop handrail. Tension of press tape are kept continuously by spring (9), while operating tension rod (5), it must be done to removed inner deck and skirt panel, and loose screw 6, release locknut (7), and adjust tension rod with nut (8). While finished adjusting it must be remembered to tighten the locknut (7). HYUNDAI ELEVATOR CO., LTD. - 17 -
11. SKIRT PANEL INSTALLATION Install the lower curve skirt section onto the skirt support angle on the lower truss. Check the skirt face is vertical to the steps. Both sides' gap between skirt panel and step shall be within 4mm. If the skirt is not vertical to the steps, loosen bolt with holding the skirt support angle. Readjust it as required. Figure 11-1 Skirt panel installation 1200TYPE:506.5 1000TYPE:405 800TYPE:304.5 TRUSS CHORD SKIRT PLATE SKIRT SUPPORT ANGLE Figure 11-2 Skirt panel installation HYUNDAI ELEVATOR CO., LTD. - 18 -
12. SECOND RUNNING TEST & SWITCH ADJUSTMENT NOTICE : Remove dust on surface of track and dust in the machine room first and then do second running test to prevent from breakage of step. Adjust upper & lower skirt switch gap. Check handrail running condition, skirt panel & step interference. Combplate & step guide roller adjustment 1 The teeth of the comb section "A"-"A" must mesh correctly with the cleats of the step tread. If comb needs adjustment, see Figure 12-1. 2 The step guide rollers guide steps running smoothly without knocking. Adjust the rollers or the skirt panels, if necessary. 3 There shall be clearance of 0.2~0.3mm between rollers and steps. 4 The top of the step guide rollers must be 5 ± 2mm below from the top of the step tread. Adjust rollers, if necessary. 5 Teeth of the combfinger shall be engaged with the grooves of the step tread by approximately 6mm depth. Raise or lower the combplate, if necessary. Figure 12-1 Combplate adjustment Figure 12-2 Step guide roller adjustment HYUNDAI ELEVATOR CO., LTD. - 19 -
13. INNER DECK INSTALLATION Figure 13-1 Inner deck installation Figure 13-2 Inner deck installation HYUNDAI ELEVATOR CO., LTD. - 20 -
14. NEWEL SKIRT INSTALLATION Figure 14-1 Top newel dimension Figure 14-2 Bottom newel dimension HYUNDAI ELEVATOR CO., LTD. - 21 -
1. Part Name W-BT ESCALATOR INSTALLATION GUIDE BOOK 1) Skirt Panel 2) Inner Deck 3) Outer Deck 4) Handrail Frame 5) Newel Skirt(Inner, Outer Side) 6) Floor Plate 7) M4 Screw (dish head) 2. Structure HYUNDAI ELEVATOR CO., LTD. - 22 -
Part Part Part Name Remark No. No. Part Name Remark 1 Direction Indicator Option 10 M5 Nut 2 Fixing Panel See Note 1 11 Newel Skirt(inner) 3 Acrylic Panel See Note 1 12 Sensor For Autostart Option 4 Newel Skirt(outer) 13 M5 Screw 5 Strip 14 Fixing Screw (ST2.9*9.5) 6 Inlet Guard See Note 2 15 M5 Nut 7 Stud Bolt 16 Connect Panel 8 Spring 17 Fixing Screw (ST4.2*9.5) 9 Plain Washer Note:1. Fixing panel ( 2 ) and Acrylic ( 3 ) are installed as part of direction indicator( 1 ). 2.Use Inlet Guard ( 6 ) according to Handrail Frame ( Aluminum Alloy Type or Stainless Steel Type ). 3. Installation and Adjustment * The Sequence of Installation 1) Check Parts before installation Install the Inner Deck, Outer Deck, Skirt Panel and Handrail Frame. Note: Please refer to related dimensions in attached drawing when installing the parts above and adjust in time if the measured dimensions are not matched. HYUNDAI ELEVATOR CO., LTD. - 23 -
2) Install the Outer Newel Skirt(Part No. 4) 3) Install the Outer Deck ( Part No.11 ) If the direction indicator is equipped, install it first and connect the related wiring, then install the outer deck. Note: The arrow displayed in the Direction Indicator panel indicates Escalator running direction. If the escalator is equipped with sensor for autostart, please install it first and connect related wiring before installing the Outer Deck. Note: Install the Inner Newel Skirt after fixing Special Nut on the skirt panel and fasten it with Dish Head Nut(M4). 4) Install Screw (M5 and M4) M5 Screw (Pan Head) : Part No.7 M4 Screw (Dish Head) : Part No.13 in Structure drawing Note: Do not fasten M4 Screw now, wait till the final installation and adjustment is over and fasten it at that time. 5) Install Handrail Inlet Guard (Part No. 6) (1) Split the top of the Inlet Guard by some degrees (but not too much), put in the Handrail, then install the Inlet Guard According to the Arrow in the picture. (2) Stud Bolt, Spring and Plain Washer (Part No.7,8,9) are needed when installing the Inlet Guard. Take care whether these parts go loose when installing. HYUNDAI ELEVATOR CO., LTD. - 24 -
6) Fasten the Handrail Guard and install the connecting parts (Part No. 9,10,16) Install Sequence: Newel Skirt Plain Washer Nut Connect Panel (For Switch Operation) Nut Enlarged A 7) Install the Inner Deck (Part No.2) First overlap the two decks by about 15mm in the direction indicated by Arrow 1, then push the deck in the direction indicated by Arrow 2 with considerable force till the two decks are aligned to each other. Note: Make sure the related wiring is connected before installing. If possible, wiring in this part should be connected in a socket way for the convenience of installation and maintenance. 8) Ajustment and Test Run (1) Please refer to related dimensions in installation drawing and installation site. Adjust the relative position of the parts and finally fasten all the Screws. (2) Start the escalator, check if Direction Indicator (Part No.1) and Sensor for Autostart (Part No.12) are normally working. (3) After installation, check if the Inlet Rubber interferes with Handrail, if yes, adjust in time. HYUNDAI ELEVATOR CO., LTD. - 25 -
5. Requirements of Packing, Transportation, and Storage Top, Bottom, Left and Right Newel Skirt should be packed in a carton after separately packed with vinyl. The carton should be labeled a packing list, and stabilize the parts inside in case of possible damage during transportation. Escalator Balustrade Installation Dimensions W-BT Model ( 30 and 35 degree) S I Z E 2 Flat Steps 3 Flat Steps TOP BOTTOM TOP BOTTOM 30degree 35degree 30degree 35degree 30degree 35degree 30degree 35degree a 804 1131 601 601 b 1195 1321.5 990.4 990.8 c 1219 1345.9 1015 1015 d 1413.6 1541.1 1209.5 1210.4 Dimensions [a, b, c, d, e ](of 2 Flat Steps) + 407 e 236.4 236.4 236.4 236.4 HYUNDAI ELEVATOR CO., LTD. - 26 -
Brief Newel Assy Install Instruction ( ) HYUNDAI ELEVATOR CO., LTD. - 27 -
W-BT SERIES ESCALATOR INSTALLTION MANUAL February. 2008 Revision 2 Hyundai Elevator Co.,Ltd. Head office & Factory San136-1, Ami-ri,Bubal-eud,Ichon-shi,Kyonggi-do,Korea P.C:467734 Tel:82-31-644-5114 Fax:82-2-745-4227 Seoul Office 1-83 Dongsoong-dong,Jongro-ku,Seoul,Korea P.C:11050 Tel:82-2-3670-0660 Fax:82-2-3672-8763/4 Shanghai Hyundai Elevator Mfg.Co.,Ltd. Head office & Factory No.182 Zhenxi (South)Liantang Town,Qinpu District, Shanghai,China P.C:201716 Tel:(021) 5981-3900 Fax:(021) 5981-3903 Shanghai Office #E-G,27 th fl..jinxuan Bldg.,No.238 Nandan Road(East), Shanghai,Chian P.C:200030 Tel:(021) 6468-6767/6427-8406/9527/5879/9677 Fax:(021) 6427-4428 Beijing Office Room#518,Gaolan Bldg.,No.32 Liangmaqiao Road Chaoyang District,Beijing,China P.C:100004 Tel:(010) 6464-3509 Fax:(010) 6464-3394 Shanghai Hyundai Elevator Installing Co.,Ltd. No.182 Zhenxi (South)Liantang Town,Qinpu District, Shanghai,China P.C:201716 Tel:(021) 5981-3993 Fax:(021) 5981-3987