Chapter 17 Operation Instruction of Soap Bubble Meter

Similar documents
MEMBRANE VACUUM MINI PUMPS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

DENSITY MEASURING SYSTEMS

OPERATING INSTRUCTIONS

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PORTABLE AIR CONDITIONER

Operation Manual For NDJ-8S Digital Rotary Viscometer

National- Spencer Inc.

CG PTFE Diaphragm Liquid Transfer Pump

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

SenTix 950 SenTix 980

WIKA INSTRUMENT CORPORATION

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

I. PUMP OPERATION AND FLOW CALIBRATION. II. Readings Manuals for Pumps, particularly SKC 224-PCXR7 and MSA Elf

Flow Measurement Options for Pipeline and Open Channel Flow

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Environment-Laboratory Ambient Conditions

Solvent Cementing Instructions For Plastic Pipe & Fittings

1. The Determination of Boiling Point

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Laminar Flow Elements

Stack Sampling Stack sampling or source sampling

Plant components, selected for sound performance

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Professional Thermohygrometer

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Typical Aluminum GFM Mass Flow Meter

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Installer s Guide 18-AH39D1-13

Scotchgard Multi-Layer Protective Film 1004

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Instruction Manual Temp 4/5/6 Temperature Meter Series

Operating instructions Platform/floor scales

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

Periodic Verification System Model 775PVS

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

Model 1210C Battery Powered Pump Shown. Description

1. SAFETY INFORMATION

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Triple Point Experiment

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Global Water Instrumentation, Inc.

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Ultrasonic Reference Blocks

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Flow-Through Cell ph SENSOR PROBES. Instruction Manual

Battery Powered Thermal Mass Flow Meters for Gases

You have just purchased the most portable and economical spray chrome system in the world!

TECHANGLE November 30, 2005 TECHNICAL PAGE

Recommended Compressor Installation Practices

Experiment SURFACE TENSION OF LIQUIDS. Experiment 1, page 1 Version of June 17, 2016

Protocol: HPLC (amino acids)

Accurate Air Flow Measurement in Electronics Cooling

OCS-S High Resolution Digital Crane Scale

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Thermocouple Thermometer Models

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Density/Specific Gravity/ Concentration Meter DMA 500

Single-Use Flow-Through Cell ph FTC-SU-HP8

Air Eliminators and Combination Air Eliminators Strainers

Thermostatic valve Type AVTA

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

LG Wireless Remote Controller

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

Laboratory Manual for Air Quality Sampling and Analysis

Battery Powered Thermal Mass Flow Meters for Gases

, User s Manual

Instruction manual for Firstline FCS12000CH

KNC Model 3666 Automatic Pressure Calibration System

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

Ultrasonic Distance Meter. Operation Manual

Steam Coil Installation, Operation and Maintenance

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Pressure calibration equipment

GLS Sampler Selection Guide

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

List of instruments required for Innovation Projects sanctioned in Deshbandhu College for the year

RGC-IR Remote Gas Calibrator for IR400

Fundamental Principles of Rotary Displacement Meters

Threaded Inline Air Heaters

FC6 FOOT CONTROLLER OWNER S MANUAL

PRDUCT SPECIFICATON TFT LCD MODULE Model : ELT240320ATP

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Transcription:

Chapter 17 Operation Instruction of Soap Bubble Meter PRINCIPLE OF OPERATION The APM 520A Flow Calibrator is designed for use as a primary standard for calibrating flow meter in the low or medium flow range. For determining the flow-rate, the traveling time of the soap film through a fixed volume marked on the glass tube is determined by the calibrated stopwatch. Figure.1 shows a typical set-up interconnecting the soap-film calibrator, flow meter under test and the Suction pump needed to cause airflow through the system. Note that air enters the calibrator at atmospheric pressure and only a soap-film and short tubing separate the Rotameter from the calibrator. As such the flow meter and calibrator operate at virtually the same pressure and temperature, no pressure and temperature correction is needed. The glass-tube provides a fixed volume with inert material that remains stable over the operating life of the calibrator. Record the s and calculate the flow rate:- Flow rate (LPM) = Volume Between two fixed point (Litres) x 60. Time taken by film to travel between fixed points (Seconds) 115

Envirotech APM 520 Flow Calibrator The Envirotech APM 520 Flow Calibrator is designed to provide a reliable and portable flow standard for flow verification of environmental sampling systems. The APM 520 is a primary flow calibrator based on a standard glass body soap bubble meter. A portable vacuum pump is provided to motion through a fixed volume and a calibrated watch is also provided to read the traveling time of soap film through a fixed volume. Each APM 520 calibrator is calibrated using a standard volume traceable to NPL maintained at Envirotech. Features Primary Standard based on Soap bubble meter. Dimensional & timing accuracy traceable to national standards. Suitable for verifying rotameters used in air monitoring systems. Specifications Flow Range : 500 ml/min to 3 Liters/min Accuracy : + 2% Operating Model : Single cycle with manual restart Temp. range : 5-50º C Humidity range : 0-70% non-condensing Power req. : 220 Volts AC single-phase AC mains. Warranty : 1 Year Optional Accessories Rotary Vane type pump with 3lpm free air displacement for providing suction pressure. For prices and clarifications contact: Envirotech Instruments Pvt. Ltd. A-271, Okhla Industrial Area Phase-1 New Delhi-110020 Ph. 26813887,6814139 Fax 26811833 116

1.0 System Configuration The soap bubble meter Envirotech APM 520 Calibrator consists of three units: - 1. Glass Tube: This unit provides the fixed volume through which air is displaced. As it is made of glass the volume does not vary with temperature and age of the instrument. 2. Suction Pump: This unit provides the suction for air displacement through the glass tube. It is portable and 220V mains operated pump. 3. Stop Watch: It is portable and battery operated it gives reading in min: sec: milliseconds. 2.0 Operation Procedure Following steps are to be used for the operation:- 1. Switch on the pump unit. 2. Generate a few films by closing the lower opening of glass tube using figure and passing them through the tube to moisten the inner surface of the tube. 3. Now set the flow rate on a Rotameter at the value you wish to check. 4. Generate a clear film and record the traveling time through the fixed volume of glass tube using the stopwatch. 5. Take 2-3 readings at different flow rates on a Rotameter and calculate flow reading and record average flow rate. Some time, if the glass tube inner surface is dry a soap film may get ruptured midway through its travel path. Repeat the steps again after stopping stop watch Attn: - If the system repeatedly fails to generate a soap-film or if multiple films are being formed check the soap solution level in the bottom portion of the glass tube. Frequent misses in generations of film indicates the level should be topped up while formation of multiple films can be corrected by removing some liquid from the system. Format for Data recording enclosed in following page 117

3.0 Precautions The APM 520 calibrator is a sensitive instrument designed for precise measurements therefore its operation and handling must be done very carefully. Points given below must be always in mind while using the equipment. 1. System contains a fragile glass part so it must be handled carefully or it may be damaged. 2. Never run the pump unit freely continuously for more than 2hrs. 3. Keep the stopwatch away from high temperature. 4. Test Piece Rotameter should be clean and dry; rotor should be move freely in side the rotameter tube. 5. Vibrations must not be present at the system while in use. So putting the system on firm structure and horizontal surface is recommended. 6. While you are making air flow connections no sharp bends to be present in the piping. Also avoid long pipes. 7. While you are filling soap solution in equipment or before use it must be filled up to an appropriate level. 8. Only qualified professionals must attempt service of this instrument. 9. Recalibration of the system recommended after every one year of use. 118

Calibration Test Data Sheet for Flow Meter Instrument Name & Sl. No.: - Rotameter No.: - Rotameter (lpm) 0.50 1.00 1.50 2.00 2.50 3.00 Time Taken in Sec. for passing 500 cc air in soap bubble tube 1 st 2 nd 1 st Actual Flow Rate (lpm) 2 nd Average (lpm) Calibration on Factor Tube Flow/ Test Piece (Calibrated by) 119

120