Air Flow Calibrations

Similar documents
I. PUMP OPERATION AND FLOW CALIBRATION. II. Readings Manuals for Pumps, particularly SKC 224-PCXR7 and MSA Elf

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE ABSORPTION OF CARBON DIOXIDE INTO WATER

Fundamentals of Mass Flow Control

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

KNC Model 3666 Automatic Pressure Calibration System

Signature and ISX CM870 Fuel System

Fire Pump Plan Review March 2010

Fundamental Principles of Rotary Displacement Meters

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Stack Sampling Stack sampling or source sampling

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Air Eliminators and Combination Air Eliminators Strainers

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

400B SERIES DIAPHRAGM PUMP

Hygro-Thermometer + InfraRed Thermometer Model RH101

Typical Aluminum GFM Mass Flow Meter

BB-18 Black Body High Vacuum System Technical Description

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Class 5 to 7 Truck and Bus Hydraulic Brake System

TABLE OF CONTENT

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

OEM-EP Pressure Controllers

Pressure calibration equipment

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Instruction Manual. T3111 T3111L T3111P T3111Ex

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

CHAPTER 3: FORCES AND PRESSURE

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

Installing a Probe. Typical Installation

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Gas Custody Transfer Calibration

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS

Introduction. Concept. Advantages PRIMING OF BEARINGLESS PUMP SYSTEMS

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Why and How we Use Capacity Control

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Precision Mass Flow Metering For CVD Applications.

Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014

6 Crankcase Ventilation

Model 43AP Pneumatic Controller, Style B

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

RITTER Multiple Sonic Nozzle Calibration System

Calibrating Differential Pressure Sensors

FLUID FLOW Introduction General Description

Flow System Calibration in Medical and Bio-medical Production Processes.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

289 SERIES FLOW METER TRANSMITTERS

Model 1210C Battery Powered Pump Shown. Description

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Vapor Pressure Curves

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Submersion/Insertion Toroidal Sensor

Overheating limit control

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

Portable Density/Specific Gravity/Concentration Meter DMA 35

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Unit 24: Applications of Pneumatics and Hydraulics

Example. Fluid Power. Circuits

Online Infrared Flue Gas Analyzer Gasboard 3000

Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating

Kobelco Extended Warranty Program.

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cooking at the Speed of light!

How To Order A Direct Flow Air Cleaner

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

Liquid level measurement using hydrostatic pressure and buoyancy

2003 ACCORD - Automatic Transmission Removal

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

The Fundamentals of Gas Flow Calibration

Microwave Meter. Instruction Manual

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

Air Pollution Control Division. Technical Services Program

AABC Specifications for Testing and Balancing HVAC Systems

MODEL INSTALLATION INSTRUCTIONS

3Portable Compressed Air Filter and Regulator Panel , with Carbon Monoxide Filtration and Monitor

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Streaming Potential System (SPT1000, SPD1000)

CG PTFE Diaphragm Liquid Transfer Pump

Mixing Valves. ARGUS Application Note: Mixing Valves

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

Air Flow Calibrations Steven E. Guffey, PhD, CIH I. Introduction A. Evaluation of exposures B. Direct measurement C. Collection and analysis of samples for TWA 1

A. Evaluation of Exposures Measure a concentration of contaminant in air - Collect sample of contaminant using sampling pump or by other means - Measure amount of air drawn during sampling - Measure amount of contaminant collected - Calculate the concentration B. Direct Measurement Device that directly quantifies the amount of contaminant in the air - Real time measurement - Series of instantaneous concentrations, or - Continuous indication of the concentration 2

C. Collection and Analysis of Samples for Time Weighted Average (TWA) Sampling device collects the contaminant and separates it from a volume of air Single, integrated measurement over a length of time allows only a time average concentration Later analysis of the collected contaminant(s) More topics * Air flow measuring devices * Advantages and limitations of each type of device. * Proper use of each type. * Calibration of pumps and secondary standard devices 3

Steps in sampling air Sample with a collection device Draw air with an air mover Measure the volume of air accurately - The accuracy of the concentration depends on the accuracy of the measurement of the air volume. - The volume is measured by control of flow for a set time. Vocabulary Flow--the volume of air drawn per time Flow (Q) = Volume (Vol) / time (t), Usually in terms of liters per minute (LPM or L/min) or ml/min. 4

A. Pumps - 1. Hand operated II. Air Movers» Single, fixed volume (detector tube pumps)» Continuous sampling (obsolete) - 2. Motor driven» diaphragm, piston, vane» adjustable flow, constant flow, pressure regulated. B. Pumps Location/size: Portable (personal) vs stationary (area) High volume: usually too large for person to wear. Used for bulk sampling (e.g., for free silica analyses) and for collection of fine particulates. Low flow (10 ml/min to 1.0 L/min): typical for personal sampling of gases and vapors on activated charcoal Moderate flow (1.0 L/min to 2.0 L/min): typical for personal sampling of aerosols Line operated vs. battery operated vs. rechargeable 5

Pumps (Continued) Manual Adjustable flow Flow controlled Pressure controlled Feedback control Programmable III. Measurement of Flow Flow is measured by the volume of air moved per unit amount of time.» Q = V / t,» Where Q = flow, V = Volume, and t is time. 6

Standard Levels of Flow Measurement Primary - Measurements generally involve a direct measurement of volume on the basis of the physical dimensions of an enclosed space. Secondary - Standards are reference instruments or meters which trace their calibration to primary standards and are capable of maintaining their accuracy. Intermediate A. Primary Standard Flow Measuring Devices 1. Instruments measure volume based on measured dimensions (i.e., length) 2. Examples» Soap Bubble Meters» Spirometers» Sealed piston Devices. 7

Primary standard Can be directly related to measured dimensions & time Simple, light weight, accurate, stable Fragile, messy liquids for field applications 1. Soap Bubble Meters ²h Buret Soap bubble A=š(D/2) 2 To pu Schematic drawing of a spirometer Primary standard Can be directly related to measured dimensions & time Accurate, used for medical applications Bulky, difficult to move, require liquid Not a field instrument. Scale Counterweight Bell Air Cavity Fluid Three-way valve Stand pipe 8

Secondary Standard Devices Require calibration against a primary device May need repeated calibrations May not be as accurate as primary B. Secondary Flow Measuring Equipment 1. Rotameters 2. Wet test meters 3. Dry gas meters 9

1. Rotameters Upper bushing O-ring seal Handy for field work. Need calibration. Accurate and precise when calibrated and maintained. Glass or plastic Measurement dependent on temperature and pressure Upper stop Flowmeter tube Plastic shield Flowmeter ball Lower stop O-ring seal Lower bushing Six kinds of rotameter floats Float reading taken here Dual floats (glass and stainless-steel spheres) Plumb-bob float Viscositystable float Ultraviscositystable float T-shaped float Combination float 10

Typical Rotameter Floats (Read float at widest dimension!) Read here Spherical Plumb bob Read here Spool Cylindrical (marked) 1. Rotameters (Continued) Measurement dependent on temperature (T) and pressure (P) of airstream passing through it Q 2 = Q 1 (den 1 /den 2 ) 0.5 = Q 1 (P 1 T 2 / P 2 T 1 ) 0.5 11

Calibration of Rotameters Calibrate against a primary flow measuring device Measure the indicated flow against the actual flow Repeat across the working range of the meter Rotamet er f low rat e (lpm) 4 3.5 3 2.5 2 1.5 1 0.5 0 0 0.5 1 1.5 2 2.5 3 3.5 4 Burette flow rate (lpm) Revised calibration curve for rotameter using bubble meter 3.5 3 Measured flow rate ( lpm) 2.5 2 1.5 1 0.5 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Rotometer flow rate (lpm) 12

Effect of Loading and Restricted Flow on Rotameter Readings 10 Comparison of changes in filter resistance for five filters Nucleopore AA Millipore Glass filter Metricel "Dirty" Vacuum (inches w at er) 9 8 7 6 5 4 3 2 1 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Rotometer flow rate (lpm) Pressure effects on pump & rotameter functioning Pump calibration vs. a standard at different pressures Ambient r 2 =0.99 15 inches water r 2 =0.99 25 inches water r 2 =0.99 Buret te f low rat e (lpm) 3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0.0 1.0 2.0 3.0 4.0 Rotameter flow rate (lpm) 13

B. Other Secondary Flow Measuring Equipment 2. Wet test meter - Bulky - Liquid filled - Atmospheric pressure Water funnel for filling Water level sight glass Water level Calibrating point 3 2 1 0 1 2 3 Gas pressure gauge Gas thermometer Gas outlet on back of meter Gas inlet on back of meter Partitioned drum (rotor) B. Other Secondary Flow Measuring Equipment Mechanical valve and counter mechanism Meter readout index 3. Dry Gas Meters - Non-portable - Large - Higher flow - Stable - Industrial applications Bellows or diaphragm cubic feet 14

Dry Gas Meters Schematic diagram showing principle of operation of twinlobed positive displacement meter C. Other Flow measuring Devices 1.Electronic bubble meters 2.Dry cal meters 3.Mass flow meters (Perkins, Pg. 732) 15

The Gilibrator (legend) 2 1 2A Nomenclature: 1. Bubble generator assembly 2. Damper plate 26 25 24 3 4 5 2a. Pulsation damper 2b. O ring 3. Spacer 22 23 6 7 8 4. Plate, bubble breaker 5. Cable assembly 6. Sensor block connecting jack 7. Sensor block locking screw 18 19 20 21 9 10 8. Sensor block 9. Base plate assembly 10. Mounting base 11. Charging indicator 12. On-off 17 16 15 14 13 12 11 The Gilibrator (legend) 2 1 2A Nomenclature: 13. Charging jack 14. Control unit 26 25 24 3 4 5 15. Average and Sample # switch 16. Delete switch 22 23 6 7 8 17. Reset switch 18. Printer jack 20 21 9 19. LCD display 20. Run indicator 18 19 10 21. Bubble generator ring 22. Bubble initiate button 23. Air inlet boss 17 11 24. Flow tube 16 12 25. Storage tubing 26. Air outlet boss 15 14 13 16

IV. Calibration of Air Flows Secondary devices are calibrated against primary. Calibration should be done under identical conditions to that of the actual sampling. See diagrams of calibration apparatus. Evaluation of pump errors. Calibrate before, during, and after sampling Diagrams of Calibration Apparatus. Bubble meter Key to diagram - Soap bubble meter - Rotometer - Pump - Pressure gauge (not shown) Pump Rotameter 17

Diagrams of Calibration Apparatus. Key to diagram - Electronic soap bubble meter - Rotometer - Pump - Pressure gauge (not shown) Built-in rotometer E. Preview of Lab Experiment I. In this experiment we will use the different air flow measuring instruments and apply them to calibrate each other. - Part 1: Calibration of rotameter using bubble burette. - Part 2: Calibration of sampling pump using rotameter. - Part 3: Evaluating the effects of filters on pump performance. - Part 4: Evaluating the effects of atmospheric pressure on rotameter performance. - Part 5: Comparison of a mass flow meter and rotameter as a function of pressure. - Part 6: Calibration of a rotameter with a (Gilibrator) electronic flow meter. 18

Pressure Gauge Layout Bubble - meter Trap Valve Electronic bubble or dry cell Mass flow meter Rotameter Pump Calibration fastest if put all devices in series All devices except bubble meters must be corrected for density Remember that mass flow devices may read out in L/min, but they control mass per time Mass flow meters: Vol/time = MassFlow/density Rotameters: calibrate at density will use (too confusing otherwise) Best to calibrate at altitude will use Density in Sealevel Lab With Resistance 1.0 Lpm Pressure Gauge 1.05 1.00 1.10 1.00 or 1.10 Bubble - meter Trap Valve Electronic bubble or dry cell Mass flow meter Rotameter * If high resistance at needle-valve, get high SP * Bubble meter reads value at NTP * Air expanded downstream of valve * Electronic bubble meter reads correct expanded value * Rotameter values must be corrected for effects of density * Mass flow meter correct for air entering bubble meter Pump 19

Density in Denver With No Resistance 1.0 Lpm Pressure Gauge 1.0 1.0 Lpm 0.88 Bubble - meter Trap Valve Electronic bubble or dry cell Mass flow meter Rotameter Pump * If no resistance at needle-valve, get room pressure * Bubble meter reads value at Denver barometric pressure * Same mass of air expanded compared to Seattle * Electronic bubble meter reads correct value * Mass flow meter and rotameter values must be corrected for effects of density unless flowrates from them calibrated in Denver REFERENCES - PERKINS, CHAPTER 18 - AIR SAMPLING INSTRUMENTS, ACGIH, Chapter 7, 1995. 20