The Measurement of Vitamin D

Similar documents
UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

D-Facts. Vitamin D Competitive Evaluation

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Introduction. Methods. Sample Processing

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Integrating Automated Systems for Regulated Bioanalysis Farmen, R.H., Struwe, P. and Groeschl, M.

Quality Assurance of Vitamins

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Optimizing the Post-implementation Monitoring of a LC-MS/MS Method

Overview. Purpose. Methods. Results

25-hydroxyvitamin D: from bone and mineral to general health marker

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

LC-MSMS - state of the art in endocrinology

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

Oasis HLB Cartridges and 96-Well Plates

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

How To Test For Contamination In Large Volume Water

Innovative vs Traditional

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

UPLC/MSMS in the analysis of physiological steroids. May Anders Feldthus Waters Corporation 1

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Purification of reaction mixtures using flash chromatography.

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

LC-MS/MS, the new reference method for mycotoxin analysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

A Novel Approach to Low Volume Sample Preparation

Vitamin D (serum, plasma)

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Glyphosate and AMPA. Medical Laboratory Bremen, Haferwende 12, Bremen, Germany. BUND, FoE

LC-MS/MS for Chromatographers

High Sensitivity MS Determination of Carryover in a New Autosampler Design

ApplicationNOTE Introduction

Vitamin D. Frequently Asked Questions

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

Mass Spectrometry and Separation Sciences for Laboratory Medicine. Measurement of Water-soluble Vitamins by UPLC-MS/MS

Press Information. Vitamin D deficiency

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Determination of Glyphosate residues in human urine samples from 18 European countries

The Facts on Equine Drug Testing

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

University Hospital Ulm Ulm, Germany. Prof. Dr. Dr. Dr. h.c. Max G. Bachem, Director Kerstin Stöhrer, Technical Supervisor

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS

METHODS OF VITAMIN ANALYSIS

THE PREVALENCE OF SUBOPTIMAL VITAMIN D STATUS IN A RANDOMLY SELECTED COHORT OF COLORADO FIREFIGHTERS

ProteinPilot Report for ProteinPilot Software

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Development and Validation of a LC-MS/MS Method for Plasma Analysis of the Serotonin Metabolite: 5-Hydroxyindoleacetic acid (5-HIAA)

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

La determinazione della Vitamina D: utilità e problemi analitici

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

To avoid potential inspection

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Validation and Calibration. Definitions and Terminology

ORGANIC SAMPLE PREPARATION

Sample Preparation Using Solid Phase Extraction

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

ASSURING THE QUALITY OF TEST RESULTS

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Sex Hormone Testing by Mass Spectrometry

INNOVATION TO MEET YOUR NEEDS

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

Transcription:

The Measurement of Vitamin D Solving a challenging assay in the clinical research laboratory 2008 Waters Corporation

Outline Introduction to Vitamin D Automated SPE approach to Vit D analysis 2008 Waters Corporation 2

Background Vitamin D Deficiency Worldwide an estimated 1 billion people don t get enough of the sunshine vitamin Hundreds of studies now link vitamin D deficiency with significantly higher rates of many forms of cancer as well as heart disease osteoporosis multiple sclerosis and many other conditions and diseases Vitamin D society.org 2008 Waters Corporation 3

Production of Vitamin D3 2008 Waters Corporation 4

What is Vitamin D? MJA 2002 177 (3) : 149-152 2008 Waters Corporation 5

Vitamin D There are two forms of Vitamin D; Vitamin D 3 produced by the body and Vitamin D 2 from the diet CH 3 H 3 C CH 3 H 3 C CH 3 CH 3 CH 3 H CH 3 CH 3 H H H CH 2 CH 2 HO Ergocalciferol Vitamin D 2 HO Cholecalciferol Vitamin D 3 MW 396.7 MW 384.6 2008 Waters Corporation 6

Why measure 25-OH Vit D? 25-OH vitamin D is the storage form of Vitamin D and therefore its concentration reflects vitamin D status 25-OH vitamin D analysis therefore provides information relating to either Vitamin D deficiency, insufficiency or toxicity Why measure 25-OH vitamin D 2 as well Common form of supplementation Measure to prevent toxicity and compliance 2008 Waters Corporation 7

Definitions of Vitamin D deficiency 25(OH) Vitamin D level ng/ml nmol/l Severe Deficiency <6 <15 Deficiency 6-16 Insufficiency 16-20 15-40 40-50 Normal >20 >50 Mosekilde L et al, Ugeskr Læger 167/1, 2005, 29-33 2008 Waters Corporation 8

Vitamin D Deficiency Worldwide an estimated 1 billion people don t get enough of the sunshine vitamin Hundreds of studies now link vitamin D deficiency with significantly higher rates of many forms of cancer as well as heart disease osteoporosis multiple sclerosis and many other conditions and diseases Vitamin D society.org 2008 Waters Corporation 9

Vitamin D: a test in demand Because of the varied ethnicities, latitudes and lifestyles in the United States and, most of Europe too, the only way to safely use vitamin D is test, test and retest Increased demand for Vitamin D assays USA o 90% increase over last 12-24 months o > 4 Million Vitamin D Assays UK o requests increased from 4000 in 2005 to >400.000 per year in 2011 2008 Waters Corporation 10

How are you currently measuring Vitamin D? Immunoassay or HPLC/UV? Do you know what you are measuring/reporting? 25(OH)D 3 only, 25(OH)D 3 and 25(OH)D 2 Can you be sure of this? Immunoassays o Prone to interferences o Variable recovery of 25(OH)D 2 2008 Waters Corporation 11

Why change to LC/MS/MS? Analytical Performance LC/MS/MS is recognised as the gold standard Measures both 25(OH) Vit D 3 and D 2 Increased specificity and selectivity from MRM and UPLC Economics Reimbursement (US) o 25 OH Vit D $45.02 o Immunoassay costs $10-$18 per sample Instrument Payback in < 2 yrs o 10,000 samples per year by Immunoassay o $180,000 in reagents costs alone 2008 Waters Corporation 12

LC/MS/MS Vitamin D analysis today The assay crying out for standardisation and harmonisation When eight labs all running validated, routine clinical LC/MS/MS assays for 25(OH) Vit D were asked to analyse 16 patient pooled samples Different LC and MS manufacturers Home-Brew Some using commercial standards (Recipe from Munich) 2008 Waters Corporation 13

Analysis of 25(OH) D 3 : In house calibrators Analysis of 25(OH) Vit D3 120 100 Conc (ng/ml) 80 60 40 Lab 1 Lab 2 Lab 3 Lab 4 Lab 5 Lab 6 Lab 7 Lab 8 20 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pool Number 2008 Waters Corporation 14

Analysis of 25(OH) D 3 : Harmonised calibrators Analysis of 25(OH) Vit D3 with harmonised calibrators 60 50 Conc (ng/ml) 40 30 20 Lab 1 Lab 2 Lab 3 Lab 4 Lab 5 Lab 6 Lab 7 Lab 8 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pool Number 2008 Waters Corporation 15

The need for standardisation and harmonisation Variation may explain the performance of MS in Proficiency Testing schemes Which lab is right? Is it important? Establish reference ranges Standardisation International Reference Standard Harmonisation Common calibrators and sample preparation will allow harmonisation of results between different labs 2008 Waters Corporation 16

Standardisation of materials Calibrators Preparation of in house calibrators is difficult Poor solubility of Vitamin D Stripped Serum, very difficult to obtain, batch to batch variation, cost Choice of matrix affects the calculated levels of Vit D Recipe supplies calibrators, controls and standards 2008 Waters Corporation 17

Requirements of a Vitamin D assay Easy to use assay Individual measurement of 25(OH)Vitamin D 2 and D 3 High Specificity Robust assay Sensitivity <5 ng/ml Fast analysis Automated 2008 Waters Corporation 18

Automated off-line Solid-phase extraction of 25-hydroxyvitamin D from serum for measurement by UPLC/MS/MS 2008 Waters Corporation 19

The Challenge and the Solution Method for the analysis of 25OHD2 and 25OHD3 Semi-automated using a Tecan Freedom EVO 100 High throughput µelution SPE Waters Oasis chemistry No evaporation step required Calibration range 2.5-150ng/mL (6-375nmol/L) <6ng/mL is severely deficient 25OHD >20ng/mL is sufficient 25OHD Sub 5-minute run time Aqueous methanol gradient 2008 Waters Corporation 20

Waters Semi-Automated 25OHD SPE Method Semi-automated SPE sample preparation Barcode reader Patient samples scanned as rack is loaded onto robot Tracking of labware and reagents Te-VacS Vacuum manifold allowing automation of SPE from plate equilibration through to sample elution Tecan Freedom EVO 100 2008 Waters Corporation 21

Waters Semi-Automated 25OHD SPE Method Sample preparation workflow 96 samples prepared in less than 2hrs All liquid handling steps executed by the robot eliminating operator error minimising operator intervention Only the centrifugation step does not take place on the Tecan Sample, labware and reagents tracking, connectivity to LIMS Identify components PPT proteins centrifugation Condition equilibrate Load supernatant wash Elute Transfer to UPLC 2008 Waters Corporation 22

MS/MS Conditions Water loss transition used for qualifier but not quantifier Water loss transitions not as specific Compound MRM transition (m/z) Cone voltage (V) Collision Energy (ev) 25OHD3 401.35>159.1 26 28 25OHD3 401.35>383.2 26 12 25OHD2 413.35>355.2 26 10 25OHD2 413.35>83.1 26 22 2008 Waters Corporation 23

Linearity 25OHD3 2008 Waters Corporation 24

Precision, Accuracy, Recovery Intra- and inter-assay precision for 25OHD3 QCs (pooled human serum) Level QC1 QC 2 QC 3 mean (ng/ml) 8 34 81 Intra-assay %CV Inter-assay %CV 7.13 6.15 4.33 8.67 9.75 7.99 Analysis of DEQAS samples within ±10.8% of LC/MS method mean Recovery: ~80% for both analytes No carryover observed following 200ng/mL injection 2008 Waters Corporation 25

Correlation Scatter Plot with Passing & Bablok Fit 70 60 50 Identity Waters 40 Passing & Bablok (I) fit (-1.45 + 1.01x) 30 95% CI bands 20 10 10 20 30 40 50 60 70 UHSM 2008 Waters Corporation 26

Patient sample: low [25OHD3] 2008 Waters Corporation 27

Patient sample: low [25OHD2] 2008 Waters Corporation 28

Vitamin D Summary Developed a sensitive assay for 25OHD2 and 25OHD3 that requires very little operator intervention µelution SPE is attractive as it lends itself well to automation Semi-automated sample preparation could be a solution for your increased sample throughput 2008 Waters Corporation 29

In Conclusion Sample preparation is required for endocrine applications Protein precipitation, liquid-liquid or solid-phase extraction are all suitable for analysis of steroids by LC/MS/MS As the test requests increase, automation of sample preparation is more attractive o minimal operator involvement For a robust method Ask Waters! Other methods currently under investigation o Plasma mets o Urinary free cortisol o Aldosterone 2008 Waters Corporation 30

2008 Waters Corporation 31