Parallax USB Oscilloscope (#28014)

Similar documents
SOFTWARE INSTALLATION INSTRUCTIONS

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Guide to Installing BBL Crystal MIND on Windows 7

File Management Utility. T u t o r i a l

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

Navigator Software. Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.

Installing a Westell USB Network Adapter

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

SharpdeskTM R3.1. Installation Guide Version

Fiery E100 Color Server. Welcome

AdminToys Suite. Installation & Setup Guide

Transferring Scans from your Dolphin into Destiny

Guide for Remote Control PDA

SoundLAB Software Download Software from the Bogen website:

Analyzer 2.0. Installation Guide. Contents

INDEX. 1. Introduction to RoMI/O Description of RoMI/O System Requirement Hardware Installation 6. 1) Hardware Installation 6

Client Program Installation Guide

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

The serial port is another kind of transmission mode in some outdated PC as a supplementary in failure of USB transmission.

Acer LCD Monitor Driver Installation Guide

Phone: Fax: Web: info@ctiautomation.net

USB CENTRAL NODE WN.CN.U(X) Installation

Embest DSO2300 USB Oscilloscope

VERITAS Backup Exec TM 10.0 for Windows Servers

Installing the Gerber P2C Plotter USB Driver

Model SL355 Noise Dosimeter/Datalogger

Quick Start Using DASYLab with your Measurement Computing USB device

WindO/I-NV2 Utility Pass-Through Tool

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

CS Digital Microscope User Manual

Centurion PLUS CPC4 Download Guide

KI6501 Data Manager. Software User Manual

Chapter 1 Downloading Images to Your Computer (Windows)

JVC Monitor Calibration 2 User's Guide

Installing Remote Desktop Connection

Power Log PC Application Software

AXIS Camera Station Quick Installation Guide

Computer Requirements

SMS (Server Management Software) Digital Video Recorder. User s Manual

Install Device Drivers and Toolkit for Windows 7

USB Driver Installation for Windows XP

Windows XP.. ELITE Firmware Update procedures.. v1.41

USB DATA Link Cable USER MANUAL. (Model: DA ) GO! Suite Quick Start Guide

USB DATA Link Cable USER MANUAL. (Model: DA ) GO! Suite Quick Start Guide

USB PC Adapter V4 Configuration

PropScope USB Oscilloscope

IXP120 Alarm Monitor Utility

Installation instructions satellite card Technisat

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

SMS Remote Software User Manual. Pro Series & Contender Series DVRs

24/48 Channel T-1 / PRI Logger. Installation Guide

Installing PowerLink on Windows 7 64-bit

Interfacing PC ChargePayment Server with Focus

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

CODESOFT Installation Scenarios

Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1

User Manual. Thermo Scientific Orion

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

TR-3 Channel Editor. Software Manual

Motorola Phone Tools. Quick Start

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

NEC Projector User Supportware 2 Software Utility Installation Guide

Bluetooth GPS with Navigation Software. Software Quick Start Guide (GBGPS201)

SA-9600 Surface Area Software Manual

Table of Contents. 2 Getting Started Guide

Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

PureEdge Viewer Training Guide

Paragon Backup Retention Wizard

Driver s License Camera Scanner Installation Guide

DataLINE Data Retrieval

Configuring Windows 7 64 bit for AutoVISION

ScanShell.Net Install Guide

RDC-7 Windows XP Installation Guide

Installation of USB Virtual COM. Version 1.02

SatTerm-G SOFTWARE MANUAL FOR A3LA-IG

How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini

Penpower WorldocScan. User's Guide

CashFlow Programming Module CPM

Caplio Utility for Windows

Installation Instructions for 9555 USB Driver

How to Download Images Using Olympus Auto-Connect USB Cameras and Olympus Master

FTP-628WSL-110 Bluetooth Configuration Guide

Windows XP Home Edition / Windows XP Professional

1. TIB388 about the Windows compatibility of all Mutoh devices subdivided in

User Guide. Introduction to 3M Digital Designs. User Guide Contents: Installing 3M Digital Designs Software. Setting up a Plotter

PLUS TV ANALOG USB STICK Installation Manual

DataSuite Installation and Activation Guide

Transmitter Interface Program

TEMP MONITOR_S2 Software operation instructions

EPSON USB/Parallel Adapter User s Guide

LABEL MATRIX7 VERSION. Japan Corporate Headquarters Canada. Europe. United States. Asia. Setting the Standard

USA MOBILITY CABLE CONNECTION AND SOFTWARE DRIVER INSTALLATION INSTRUCTIONS. For. Unication M90 Device USB To RS232 Adapter TABLE OF CONTENTS

EasyCAP Video Capture with Audio Quick Installation Guide

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

Transcription:

599 Menlo Drive, Suite 100 Rocklin, California 95765, USA Office: (916) 624-8333 Fax: (916) 624-8003 Toll-Free Tech Support 888-99-STAMP Technical Email: support@parallax.com Educational Email : stampsinclass@parallax.com Web Site: www.parallax.com Parallax USB Oscilloscope (#28014) Digital Real-time and Storage Oscilloscope Kit Contents Parallax USB Oscilloscope 3 sets of 1X probes 1 USB cable Parallax CD-ROM (not shown) General Information The Parallax USB Oscilloscope (formerly OPTAscope) is a digital real-time storage oscilloscope that connects to your PC via USB. The small, portable hardware package uses a high-speed USB cable for both data and power, so it requires no separate power supply. All oscilloscope controls are managed through a point-and-click PC software interface. This low-cost and easy-to-use oscilloscope is a perfect solution for students and hobbyists who need to measure and interpret signals for their projects. 2004 Parallax, Inc. Parallax USB Oscilloscope (#28014) Version 1.0 Page 1

The Understanding Signals Student Guide For a detailed introduction to using the Parallax USB oscilloscope, we recommend the Understanding Signals Student Guide by Doug Pientak of Parallax Inc. Each activity includes a BASIC Stamp -controlled example circuit and code, directions for configuring the oscilloscope and placing the probes, and screencaptures of the Parallax USB Software interface displaying the signal. Understanding Signals is included as a pdf on the Parallax CD under Documentation Educational Curriculum Understanding Signals v1.0. You may purchase a printed copy (part #70009) or download the latest version from www.parallax.com. (Understanding Signals v1.0 was written when this oscilloscope was sold under the name OPTAscope, but all the experiments in the text are valid for the Parallax USB Oscilloscope.) Specifications: 2 Channels view 2 signals at once 1 million samples per second maximum sample rate with one channel 500, 000 samples per second sample rate with 2 channels View sine waves up to 60 khz View square waves up to 100 khz 4 FFT functions: Black-Harris, Hamming, Rectangular, Hanning 20 Vpp maximum input for channel 1 and channel 2 200 khz bandwidth 8-Bit vertical resolution External trigger source: TTL rising edge, 5 V TTL maximum input Trigger on rising or falling edge at any voltage Variable trigger voltage on channels 1 and 2 Horizontal trigger position settings at 10%, 50%, and 90%. Auto and normal trigger modes Vertical, horizontal, and paired cursor functions Zoom feature with active cursors Built-in screen-capture bitmap function 1X probes included USB 1.1 for data and power supply no other power supply needed. Size: 5 x 2.25 x 1.5 (excluding cable and probes) Weight: 8 ounces System Requirements Minimum** configuration: Windows 98 or higher operating system* Pentium 233 MHz processor 32 MB of RAM At least 15 MB of free disk space Graphics card able to display an 800 X 600 resolution at 16-bit color depth. HTML Viewer Mouse or similar pointing device Recommended** configuration: Windows XP Pentium II 450 MHz processor 64 MB of RAM 20 MB free disk space Graphics card able to display a 1024 X 798 or higher resolution at 32-bit color depth. HTML Viewer Mouse or similar pointing device *Windows 95 and NT are not supported, Windows XP is recommended. ** Performance is based on CPU speed. 2004 Parallax, Inc. Parallax USB Oscilloscope (#28014) Version 1.0 Page 2

Software and Hardware Installation with Internet Access NOTE: These instructions replace those found in the README files. 1. We recommend downloading the latest version of the software (free) from http://www.parallax.com/html_pages/downloads/software/scope.asp However, you may install the software from the Parallax CD as noted in steps 1-3 in the section below, then return to these instructions. NOTE: setup_v4.0.exe (included on the October 2004 Parallax CD) does not contain help files. Check the web page listed above for Help files with separate installation instructions. 2. Install the software by following the Install Wizard directions. Ignore the README files. 3. Connect the Parallax USB Oscilloscope hardware to your computer's USB port. NOTE: You will get the best results if your Parallax USB Oscilloscope is the only device connected to the root, because this device is powered from the USB port. If you need to have other devices connected that are also powered from the same USB port, we recommend you purchase a powered USB hub. 4. If the Found New Hardware Wizard window pops up, you will be asked Can Windows connect to Windows Update to search for software? Click on Yes, this time only then continue to follow the prompts until installation is complete. 5. Go to the Running the Software for the First Time section on page 4. Software and Hardware Installation without Internet Access NOTE: These instructions replace those found in the README files. Also note: the Parallax USB Oscilloscope setup_v4.0.exe (included on the October 2004 Parallax CD) does not contain help files. Check the web page http://www.parallax.com/html_pages/downloads/software/scope.asp above for Help files with separate installation instructions. 1. Insert the Parallax CD into your CD drive. 2. From the Welcome screen, click on Software, select the Parallax USB Oscilloscope folder, then click on the Parallax USB Oscilloscope diskette icon. Note: if the Welcome screen does not launch, browse to the CD drive, and select 3. Install the software by following the Install Wizard prompts. Ignore the README files. 4. Connect the Parallax USB Oscilloscope hardware to your computer's USB port. NOTE: You will get the best results if your Parallax USB Oscilloscope is the only device connected to the root, because this device is powered from the USB port. If you need to have other devices connected that are also powered from the same USB port, we recommend you purchase a powered USB hub. 5. When the Found New Hardware Wizard window pops up, you will be asked Can Windows connect to Windows Update to search for software? Click on No, not this time then continue. 6. Click on Install from a list or specific location (Advanced) 7. Select Search for the best driver in these locations. 8. Also select Include this location in the search: 9. Click on Browse. 10. Locate C:\Program Files\Parallax\USB Oscilloscope\Driver. Note: These files were placed in this location using the default software installation. If you selected another location during the software installation, you will need to browse to that location to find this folder. 11. Click on Next. 12. A Hardware Installation warning window will appear. Click on Continue Anyway. 13. Completing the Found New Hardware Wizard should appear. Click Finish. 14. Since this device requires two separate drivers, after a brief pause the Found New Hardware Wizard will open again. Or, you may get an error message asking for an additional FTDI file. You must repeat the process from step 6 to complete the driver installation. 15. Go to the Running the Software for the First Time section on page 4. 2004 Parallax, Inc. Parallax USB Oscilloscope (#28014) Version 1.0 Page 3

Running the Software for the First Time NOTE: These instructions replace those found in the README files. 1. In your computer s Device Manager, look under Ports (Com& LPT) and note the number assigned to the new USB serial port. 2. Run the Parallax USB Oscilloscope software from the desktop icon, or from Start Parallax USB Oscilloscope USB Oscilloscope 4.0.0. 3. Click anywhere on the software identification window to open the interface. 4. From the menu bar, select File Set COM Port to open the window shown below. 5. In the Selected COM Port field, enter the COM port number that you identified as the new USB serial port. When the correct COM port number is entered, the dot indicator below the field will turn from red to green. 6. If you wish, follow the prompts to calibrate your probes. 7. Your Parallax USB Oscilloscope is ready to use! Safe Oscilloscope Use Before test-driving your Parallax USB Oscilloscope, it is important for you to be aware of the general safety guidelines for working with oscilloscopes. Working with oscilloscopes requires you to work on circuits with live voltage. It is your responsibility to learn the following safety guidelines and practice them faithfully while working with live circuits. Failing to do so can result in equipment damage, and severe personal injury or death. Below you will find a list of safety rules that you are to use as a guideline while working with live circuits and the Parallax USB Oscilloscope. Remove metallic jewelry and watches before starting. Make sure your hands are clean and dry while working with any oscilloscope. Work upon an anti-stat pad that is properly grounded. Keep your work area free from food and beverages. Do not attempt to measure any voltage that could be 20 Vpp or higher. If anything you are working on gets hot or smokes, turn it off immediately. ALWAYS disconnect the power supply to the circuit you are measuring before walking away from your workstation. 2004 Parallax, Inc. Parallax USB Oscilloscope (#28014) Version 1.0 Page 4

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Parallax: 28014