Similar documents
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

SDX Submersible Depth Transmitter User Manual

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Features. Picture. Specifications

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Measurement & Control. Features. Applications. High accuracy. Bore hole monitoring

PART 1 - INTRODUCTION...

Models SFP33 & SFP32 Pressure Transmitters

The Do s and Don ts of Pressure Transducers

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

PIEZOMETER AIRFLOW MEASURING RING

Pressure transmitter For general industrial applications Model A-10

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Liquid Level Limit Switch liquiphant T FTL 20

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

General Purpose ph/orp Sensors

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Series 510 Submersible Level Transmitters

PRODUCT PROFILE FEATURES

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Excellence through Versatility

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MicroMachined Silicon modular pressure sensor

4 Posiflow Proportional Solenoid Valves

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Microcor Wireless Transmitter (MWT)

Electronic Flow Switches

OPTIMASS 1400 Technical Datasheet

HIH-4000 Series Humidity Sensors

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Temperature & Humidity SMS Alert Controller

2.24. Pump Controller 704. Data Sheet

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Typical Aluminum GFM Mass Flow Meter

The Unique Accelabar Flow Meter

Global Water Instrumentation, Inc.

OEM-EP Pressure Controllers

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Centro-Matic Automatic Lubrication Systems System Controls

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

RAEGuard EC FGM-13XX

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

IFC 070 Technical Datasheet

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

VSO MAX HP High Flow Proportional Valve

Turbine Flowmeters for Gas Applications

nvision Reference Recorder

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Micro Motion Model D and DL Coriolis Flow and Density Meters

Plastic tube flowmeters Series PT/PS

Mass Flow Meters & Controllers

3500/62 Process Variable Monitor

Electronic Pressure Switch EDS 300

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Sanitary Type Electronic Flow Switches

SELECT MOUNT MONITOR

For Multi-Parameter Meters see mvx

Data Sheet PS1B Pressure Switch

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Morrison Bros. Co. General Product Specifications

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Operating Instructions

Smart Sensing Solutions Since 1954

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Inductive sensor NI10-M18-Y1X-H1141

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electromagnetic Flow Meter

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Duct Humidity Transmitter

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Micro Motion 3098 Gas Specific Gravity Meter

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

The L&J Engineering Model MCG 1500SFI Servo Gauge

Microwave Meter. Instruction Manual

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

ATL Fuel Level Sender Probes

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Transcription:

PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal for clean liquids 1.98 50.4 mm 1 1/2 tri-clover fitting Ideal for sanitary C US The PT-500 is a rugged submersible pressure transmitter designed for tank liquid level measurement, water and wastewater applications, well depth measurement, and offshore water depth measurement. Features Simple to install High precision, solid state signal: 4-20 ma Exclusive, removable and reusable cage 1/2 NPTM on cable end for use with conduit Durable transducer face Intrinsically safe for Class 1, Div 1/Zone 0 (4-20mA only) Built-in lightning protection on every model

The Only One In Its Class Built-In Lightning Protection Lightning strikes are always a threat to exposed electrical infrastructure - especially when it s 40 feet underground. That s why we ve included built-in lightning protection as a standard feature for every model (including intrinsically safe version). So forget about buying a $300 industrial surge protector. It s included. Class 1, Divizion 1/Zone 0 The PT-500 is built to handle tough applications - including hazardous locations. It s intinsically safe design means it s suitable for even the most explosive environments. Field Adjustable Zero Even the best submersible pressure transducers drift a little over time. Ours stands apart from the others because you can adjust the zero point in the field - bringing it back within spec. All it takes is a simple magnet (included). It s easy to do and means you won t need to have it recalibrated as often. Re-Usable Cage Need to protect your sensor? The cage is the ideal solution. But it costs extra no matter who you buy from. Ours can be removed and reused when it s finally time to replace your sensor - saving you money. Tight budgets can be challenging. Why not save as much of it as you can. Low Power Consumption The Modbus and voltage output versions use very little power and have a very fast response time - ideal for battery-powered installations. 2

Impressively Thoughtful Design At the end of the day, the PT-500 submersible pressure transducer is modeled after your needs. An accurate, robust sensor was the priority, then we simply thought of you and took it a few steps further! Visit our website at www.apgsensors.com to learn more. Contact us at 435-753-7300 to discuss your application and get a quote. Tank Cloud Compatible As stated, the PT-500 s low power consumption make it ideal for remote monitoring applications - especially when you re relying on solar or battery power. The Modbus version is compatible with our online remote monitoring software, Tank Cloud. View level readings online for free on our Tank Cloud portal - levelandflow.com. You can even add in low cost data logging and alarms. Tank Cloud means you can keep an eye on your remote tanks and wells from your office or your smartphone. Contact us today to discuss how remote monitoring with Tank Cloud can help you save time and money! 3

Applications The veratility and reliability of the PT-500 makes it a great multi-purpose level sensor. It exceeds at water and hydrocarbon based liquids where the density of the liquid is consistent. Here are typical applications where you ll find our PT-500 submersible pressure transducer: Lift Stations Retainer Ponds Well Level Monitoring Process Tanks Remote Level Monitoring Chemical Tanks Water Storage Oil Storage Featured Configuration: PT-500 + MND Modbus Display Our Modbus version expands the compatibility of PT-500. However, it also makes it compatible with our Tank Cloud remote monitoring solution, and our various other Modbus products - including our MND display. The MND is a powerful display that can be programmed as a master, a slave, or a snooper. When combined in master mode with the PT-500 submersible pressure transmitter it makes an accurate and easy-touse digital stick level measurement tool. This setup is great for both a stationary installation or a mobile instrument. This is made possible, largely, by the ability the MND has to power another sensor with its battery. The MND can both display the PT-500 s reading and provide it power. The wiring is also flexible. We can integrate the two by wiring them together in the factory, provide you with a connector on the display, or get you a wiring tee. Contact us to learn more about using the MND and PT-500 together. We can help you get both configured correctly and ordered together. Refer to the MND datasheet for more information. 4

PT-500 Specifications Performance Accuracy (linearity, hysteresis, & repeatability): 0.50% of span (BFSL) 1 Year Stability: 0-20,000 PSIS Temp Compensation Range: 0º - 130ºF (-17º - 54ºC) Temp Effects on Zero & Span: 0.025% FS/ºF @ 70º Connectivity Output: 4-20 ma 0-5, 0-10, 1-5, 1-10 VDC mv/v Environmental Maximum Depth: Submersible up to 450 ft. Certification 4-20 ma Output Only CSA Intrinsically Safe: Class 1, Division 1; Groups C & D Ex ia IIB T4 Class 1, Zone 0, AEx ia IIB T4 Ambient: -40-85ºC Electrical Supply Voltage: 4-20 ma, 0-5 VDC, 1-5 VDC: 9-28 VDC 0-10 VDC, 1-10 VDC: 14-28 VDC mv/v: 10 VDC Current Draw: 4-20 ma: 3-30 ma 0-5 / 0-10 VDC, 1-5 / 1-10 VDC: 3 ma Electrical Connection: Vented watertight cable w/free ends Up to 200 lbs tensile strength Electrical Protection: Lightning and Surge protection is built in. Protected against reverse polarity, surge per IEC 61000-4-5 Physical Housing: 316L SS Cable: Polyurethane Protective Cone: Delrin Overmolded Cable 5

PT-500 Common Model Configurations Waste Water Configurations Model Number PT-500-C-5-PSI-G-L1-E0-P39-40-N0 PT-500-C-10-PSI-G-L1-E0-P39-40-N0 PT-500-C-15-PSI-G-L1-E0-P39-60-N0 PT-500-C-20-PSI-G-L1-E0-P39-60-N0 Model Description 4-20mA Output, 0-5 PSI, Removable cage and 1-1/2 Tri-clover, 40 ft. PUR cable 4-20mA Output, 0-10 PSI, Removable cage and 1-1/2 Tri-clover, 40 ft. PUR cable 4-20mA Output, 0-15 PSI, Removable cage and 1-1/2 Tri-clover, 60 ft. PUR cable 4-20mA Output, 0-20 PSI, Removable cage and 1-1/2 Tri-clover, 60 ft. PUR cable Clean Water Configurations Model Number PT-500-C-5-PSI-G-L1-E0-P1-40-N0 PT-500-C-10-PSI-G-L1-E0-P1-40-N0 PT-500-C-15-PSI-G-L1-E0-P1-60-N0 PT-500-C-20-PSI-G-L1-E0-P1-60-N0 Model Description 4-20mA Output, 0-5 PSI, 1/2 NPTM and removable nose cone, 40 ft. PUR cable 4-20mA Output, 0-10 PSI, 1/2 NPTM and removable nose cone, 40 ft. PUR cable 4-20mA Output, 0-15 PSI, 1/2 NPTM and removable nose cone, 60 ft. PUR cable 4-20mA Output, 0-20 PSI, 1/2 NPTM and removable nose cone, 60 ft. PUR cable PT-500 Accessories Please order separately, by part number. Description Part Number 316L SS hex coupler, 1/2 NPTF to 1/2 NPTF 511414 Desiccant drying cartridge for breathing tube 122774-0028 Cage assembly 548001-8888 6

Model Configuration Options Model Number: PT-500 - - - - - - - A B C D E F G H A. Cable Type - Urethane - Blue (with vent tube) A PVC - Black (no vent tube - sealed unit) B Hytrel.31 Ø - Black (with vent tube) C PVC - Black (with vent tube) D Hytrel.25 Ø - Black (with vent tube) B. Pressure Range Specify range in desired unit of measure Max Water Depth 462.2 ft. (140.9 m), 300 psig C. Standard Units of Measure PSI FTH2O INWC INH2O MMH2O FWC D. Output L1 4-20 ma, 2-wire L3 0-5V, 4-wire* L9 10 mv/v, 4-wire* L10 0-10V, 4-wire* L12 1-5V, 4-wire* L21 1-10V, 4-wire* E. Overmold E0 No overmold for 1/2 NPTM fitting for conduit E37 Pigtail with overmolded cable F. Process Connection P1 1/2 NPTM with removable plastic nose cone P5 1/4 NPTF P37 Welded Cage (anti-snag 1 piece fitting) P38 1-1/2 tri-clover with 3/4 diaphragm P39 Reusable Cage (includes P38 fitting) G. Cable Length (specify length of cable needed in feet) H. Accuracy N0 ±0.25% N1 ±0.25% with NIST certification N2 ±0.1% with NIST certification Note: Indicates this option is standard. L5 Modbus RTU, 4-wire RS-485* Pressure reading only L31 Modbus RTU, 4-wire RS-485 * Level calculations, tank volume Note: *Indicates this option does not yet have CSA Approvals. Note: Indicates Field Adjustable Zero feature is not included. 7

PT-500 Submersible Pressure Transducer Robust from Top to Bottom This fully welded body is ready for the most demanding applications. And with it s long list of features, the PT-500 from APG is in a class of it s own. Give us a call at (435) 525-7300 to learn more. 1/2 NPT Fitting Mount to a conduit pipe Hang from a steel wire Saves cable from wear Avoid interference with pumps CSA Class 1, Div 1 Safe for operation around flammable gas Field Adjustable Adjust zero point with simple magnet Magnet provided with the sensor Don t have to send to the manufacturer for simple adjustments High Strength Cable Custom made to our spec High tensile strength with Kevlar (200 lbs) Safe transducer ventilation Laser Welds Superior laser welds Extremely durable No cracks or leaks Built-In Surge and Lightning Protection No surge-protector necessary Protection built right into the sensor IEC 61000-4-5 compliant Auto Temp Compensation Embedded temperature sensor Automatic compensation Durable Transducer Face Can be handled freely Will not be damaged from simple touch State-of-the-art MEMs transducer Patented Re-Usable Cage Only re-usable cage on the market Keeping the cage saves money on replacement sensors Document #9004534