Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014)

Similar documents
Sample Table. Columns. Column 1 Column 2 Column 3 Row 1 Cell 1 Cell 2 Cell 3 Row 2 Cell 4 Cell 5 Cell 6 Row 3 Cell 7 Cell 8 Cell 9.

All V7 registers support barcode printing, except the Sharp 410/420 1A ROM and that limitation is based upon the register.

Instructions for Formatting APA Style Papers in Microsoft Word 2010

Merging Labels, Letters, and Envelopes Word 2013

Create a Poster Using Publisher

RP Pocket PC Scanner Reference Manual For PPT8800

WHAT S NEW IN WORD 2010 & HOW TO CUSTOMIZE IT

CALIBRATING YOUR SYSTEM. Follow our guidelines carefully to ensure proper system function. EQUIPMENT

Generative Drafting. Page DASSAULT SYSTEMES. IBM Product Lifecycle Management Solutions / Dassault Systemes

5. Tutorial. Starting FlashCut CNC

Instructions for Formatting MLA Style Papers in Microsoft Word 2010

Protocol for Microscope Calibration

Microsoft Word 2010 Prepared by Computing Services at the Eastman School of Music July 2010

In this session, we will explain some of the basics of word processing. 1. Start Microsoft Word 11. Edit the Document cut & move

NVMS User Manual

Task Card #2 SMART Board: Notebook

Kitchen and Bath Design Tutorial

Getting Started Guide

Virtual Office Remote Installation Guide

Lesson 7 - Creating Animation II

1. Installing The Monitoring Software

Access I Tables, Queries, Forms, Reports. Lourdes Day, Technology Specialist, FDLRS Sunrise

Excel 2003 A Beginners Guide

EPSON SCANNING TIPS AND TROUBLESHOOTING GUIDE Epson Perfection 3170 Scanner

Excel 2007 A Beginners Guide

Royal Mail Despatch Manager Online Printer Installation Guide

MS Word 2007 practical notes

End User Guide. July 22, 2015

Kitchen and Bath Design Tutorial

OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G

Pictorial User s Guide

Working with Video in PowerPoint 2010

Getting Started. Getting Started with Time Warner Cable Business Class. Voice Manager. A Guide for Administrators and Users

State of Ohio DMS Solution for Personnel Records Training

AUDIO l VIDEO END-USER GUIDE. Fernwood 3E02 Conference Room System New Touch Panel

Digital Marketing EasyEditor Guide Dynamic

Getting Started Guide

Multi Client (Integration)

Kitchen and Bath Design Tutorial

Introduction to OpenOffice Writer 2.0 Jessica Kubik Information Technology Lab School of Information University of Texas at Austin Fall 2005

Horizon Patient Folder User s Guide

Excel -- Creating Charts

NIS-Elements Viewer. User's Guide

Central Management Software CV3-M1024

Welcome to The Grid 2

Professional Surveillance System User s Manual

To Install EdiView IP camera utility on Android device, follow the following instructions:

OPERATION MANUAL. IWB Setup Software/EyeRIS NEC edition

How to use the Microfilm Reader/Scanner

Project Setup and Data Management Tutorial

SEMTech Solutions. Leaders in Refurbished SEMs. SEMTech Solutions Windows 7 SOFTWARE CONTROL SYSTEM

Microsoft Access 2010 handout

Test Generator. Creating Tests

CORSAIR GAMING KEYBOARD SOFTWARE USER MANUAL

idisplay v.2.0 User Guide

Appendix A. CMS(Client Management Software)

Tutorial for Tracker and Supporting Software By David Chandler

Contents. A July 2008 i

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

PowerPoint 2007 Basics Website:

Working with SQL Server Integration Services

WPI Laser Cutter User Guide

Creating a Poster in PowerPoint A. Set Up Your Poster

ONBASE OUTLOOK CLIENT GUIDE for 2010 and 2013

Embroidery Fonts Plus ( EFP ) Tutorial Guide Version

Introduction to Autodesk Inventor for F1 in Schools

Introduction to CATIA V5

6. If you want to enter specific formats, click the Format Tab to auto format the information that is entered into the field.

Excel 2007 Basic knowledge

Tutorial for Basic Editing in Adobe Premiere Pro CS5

Planning and Managing Projects with Microsoft Project Professional 2013

Migrating to Excel 2010 from Excel Excel - Microsoft Office 1 of 1

SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL

Scientific Graphing in Excel 2010

Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424

NVMS USER MANUAL. Version 2.1.0

Quick-Start Guide. Remote Surveillance & Playback SUPER DVR MONITORING SOFTWARE. For use on Q-See s QSDT series of PC Securitiy Surveillance Cards

Intro to Excel spreadsheets

SketchUp Instructions

Microsoft Excel 2013 Splitting Windows and Fixing Panes (Level 3)

KViewCenter Software User Manual 2012 / 04 / 20 Version

Internet Explorer 7. Getting Started The Internet Explorer Window. Tabs NEW! Working with the Tab Row. Microsoft QUICK Source

Introduction to Autodesk Inventor for F1 in Schools

Corsair Link v2.4 Manual. Initial Set-up. Placing devices within the chassis

SpaceClaim Introduction Training Session. A SpaceClaim Support Document

Communicate: In Print

MICROSOFT OUTLOOK 2010 WORK WITH CONTACTS

MC Talent Management System. Goals Module Guidebook

User Manual of Web Client

TouchKit Software User manual for Windows 7 Version:

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

Unified Communicator Advanced Training Handout

How To Set Up Flir Cloud Client For Pc Or Mac Or Mac (For Pc Or Ipad) On A Pc Or Pc Or Mouse (For Mac) On An Iphone Or Ipa) On Pc Or Tv (For Ipa

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

PowerPoint 2013: Basic Skills

Micro Cam Software. User Manual V1.3

Banner Document Management Suite (BDMS) Web Access Help

Post Processing GPS raw observations using data obtained from Continuously Operating Reference Stations (CORS)

Excel Tutorial. Bio 150B Excel Tutorial 1

Transcription:

Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014) [The beige shaded areas introduce the user interface in detail. For turn on and run operation, you may skip these descriptions. The blue shaded areas highlight important information you should be familiar with for successful use of the instrument.] Please send feedback on this manual to admin@janscientific.com

Turn on the UVEX, place the crystallization tray on the microscope stage and launch the control program CrystalDetect. As the program initializes, it checks for the presence camera, light controller, motors, and database connection. On successful discovery, the corresponding buttons turn green. If a button is not green, check to make sure none of the cables have been disconnected and if the problem persists, contact JAN Scientific. Database may require Ethernet connection. The X, Y & Z positions are homed and you will be asked to enter details about the plate, starting with the barcode.

Scan the barcode with the scanner or enter it by hand. The barcode is assumed to be unique to each crystallization plate. If the plate is scanned for the first time, you will be asked to enter more details, such as plate type and user name. If the plate has already been scanned at least once, these details will be autofilled. If you cancel at this point, the UVEX enters a hybrid mode whereby the plate can be moved with the help of the joystick (physical or virtual), and objectives can be positioned with the buttons, but the well position information will be missing. The grid will be greyed out and autoscanning will be disabled but individual drops can be imaged and the images stored. To continue with the automated mode, right click under Plate and select the appropriate plate type. To define a new plate type select Add New / Edit. This opens the Manage Plates window where you can modify existing plate definitions or create new ones by copying an existing plate type and editing it.

Let s illustrate this by creating a new plate LCP-glass, for 96-well LCP glass plate. Start with another 96-well plate (1 drop per well), by double clicking on Corning 3551. Click on Copy Plate which opens a naming window for the copied plate. We ll type LCP-glass for the name of the new plate and click OK. This will add LCP-glass with the same definitions as Corning 3551 under Available Plates on the left. You can modify the row and column spaces as necessary as well as change the number of drops and the spacing between them.

Click Save to store the new parameters. If you close the Manage Plates window at this point, the plate type for the current plate will be LCP-glass. This of course can be changed by right clicking and choosing a different plate from the drop down list. Let s build the definition table for a plate with 3 drops in a triangular pattern in each well as an exercise. Let the X (horizontal) and Y (vertical) offset between the centers of the drops be 2 mm. Let s start with a 4-drop configuration (2x2) with 2 mm separation between the drops in X & Y The first drop (top left) is always set as drop 00 (row 0, column 0) and the plate calibration is always done with reference to this drop. Therefore, to generate the triangle, we will keep the 00 drop in place and shift the bottom row to the left and then expunge the second drop of the top row. Our counting starts with 0 which makes the first row an even-numbered row. We shift the second row (odd-numbered) to the left by 1 mm, or by -1 mm and click on the 2 nd drop on the top row to un-highlight it leaving us with a triangle. We can build pretty much any pattern along these lines.

Enter the user name by right clicking and selecting from the list or click Add New and add the new user name in the pop-up window. Project ID, if desired, can be entered similarly.

Click Continue and the plate will be moved to default X, Y and Z values set for that plate type (MRC 2 well, etc.) If you have created a new plate type by copying an existing one, the default X, Y and Z values also are copied. Because the UVEX is designed to accommodate plates of differing heights, ranging from flat glass plates to Linbro plates, setting of the Z default value such that a certain distance is maintained between the longest objective lens and the plate is very important. In these circumstances, it would be best not to load the plate on the stage, go through the process of scanning the barcode and creating the new plate type, etc. and once the default X, Y and Z distances are reached, activate the manual button and lower the stage with the joystick (physical or virtual). Click Set Focus, load the stage with the plate, move to the first well and first drop (A01_00), Calibrate Plate and Set Focus again. Choose this as the default setting for the new plate type. Controls: Motion Control: move the plate by clicking anywhere on the grid (well) and/or on the drop matrix on the top right. The current position is displayed under the grid. Manual on activates joystick, Calibrate and Set Focus allow the alignment of the wells/drops in X, Y and Z. Objective lenses may be moved by clicking on the lens buttons. Fusion on activates Extended Depth Imaging. Start and End values are the Z range for EDI and the slices are the number of Z images taken per drop. Light Control: Center and Edge Lighting sliders adjust the intensities of the brightfield light source. The sliders are on a log scale. Preview opens the video window and the video image can be toggled between Normal and zoom Imaging Control: Brightfield (transmission image) and UV fluorescence exposure times are varied by tapping the up and down arrows. Images are obtained by pressing the buttons labeled respectively, Brightfield and UVFL. Save BF and Save UVFL save the last obtained image. Autosave saves all images. Storage Path at the bottom points to the folder where the images are saved. Autoscan saves images obtained during a scan and writes the relevant information into the database. Where applicable, there may be a third button UVABS (UV absorption) or X-pol (crossed polarization). Autoscan + drop find scan a plate for brightfield images only for drop find

In the case of virtual joystick, the controls are as shown here. The X, Y and Z speed sliders are set to a log scale. Red buttons stop the motion in an emergency. Display Panels: Brightfield UV FL UVABS or POL (if available) Main display Main display shows the current image. The small panels on the right show zoomed images of the latest, BF, UVFL or UVABS/POL images. As you move the cursor over the main display the zoom panels are updated. The main display can be switched to BF, UVFL or UVABS/POL image by clicking on the corresponding zoom panel. The contrast of each image can be changed first by clicking on the zoom panel and adjusting the slider. The saved image is not affected by contrast adjustment here.

To measure a feature size in the main display only, activate the ruler icon and draw line on the feature with left button of the mouse pressed. You also can measure the feature size in a zoom panel by left clicking on the feature in the main display and activating the ruler. Now you will be able to draw a line either in the main display or any of the zoom panels. Left click again on the main display to unfreeze the cursor and click on ruler icon to clear the measurement. Once the plate is loaded, calibrate the plate with respect to the first drop. Activate joystick ( Manual on ), start preview, and center and focus the first drop. Click Set Focus. Click Calibrate Plate which activates the calibration buttons below the control panels. With the first well, first drop centered, click on 1 Point Calibration and the A1_00 Selected button is activated. If the drop is centered in preview window no further selection is necessary. Another way to select the first drop is to take a brightfield image, and left click on the center of the drop even if it were not centered in the image panel. This will cancel the offset of drop center from image center. This method also is more useful since there always is some mismatch between the centers of the video image and brightfield image. Click A1_00 Selected and then Done. The calibration is finished.

In many cases, calibrating with respect to the well center, rather than the drop center may be sufficient. With small volume drops, or hanging drops or LCP sandwich plates, the well center may not always coincide with the drop center and the drops may not even be parallel to the sides of the crystallization plate. In these cases, 2-point calibration or drop finding would be more helpful. 2-point calibration: In LCP sandwich plates and robot-pipetted hanging drop plates with an adhesive layer in between, the rows and columns of drops may not be parallel to the plate edges. In these instances, calibrating the positions of the first drop in wells A01 and A12 and interpolating the positions of the intermediate drops (02 through 11) would align the drops correctly. After activating Calibrate Plate, select 2 Point Calibration, center A01_00 either in Preview or Brightfield as before and click A1_00 Selected. Center A12_00 and click A12_00 Selected and click Done. The positions of each drop will be recalculated based on these measurements and stored for current and future scans.

Drop finding: After setting the focus and centering the first well and first drop, Select the Drop Find radio button and click Auto Scan. The plate will be scanned and the Plugins tab will be opened.

The drop images and calculated centers will be displayed in the form of cross hairs. Where needed, you can drag the cross hair and center it correctly. You can move through the different drops by clicking on them under Drop Location box. Click Accept New Centers and you will be taken back to CrystalDetect tab. If you wish to reset the drop centers, click Disable Drop Find.

Lighting: The UV light intensity is fixed. However, in difficult cases, you can achieve the same effect as higher-intensity UV excitation by lengthening UV exposure time to up to 5s. Brightfield lighting has two components Center Lighting and Edge Lighting, the intensity of either can be changed via the appropriate slider. Edge Lighting is useful in cases where the drop edge is dark and in some cases to highlight features that are not otherwise obvious. Center Lighting only example: Edge Lighting only example:

For the 5x lens, these are similar to bright field and dark field images in microscopy. Autoscanning: When you are ready to scan a plate, click Auto Scan and a Scan Setup Dialog box will pop up where you will be asked to choose between different lenses and modes of scanning (Brightfield, UV Fluorescence and UV Absorbance or Polarization, if available). In order to speed up this process, you can set the Default profile to be the one most commonly used. To edit a current profile or create a new one, select the lenses and the modes, right click under Profile Name and select Add New, and give the profile a name. If the profile name exists previously it will be updated with the current selection. Click Continue and the scanning will begin. The scanning will be in the order of 1 st lens Brightfield and UVFL, 2 nd lens Brightfield and UVFL, etc., and 1 st lens UVABS or POL, 2 nd lens UVABS or POL. Click Stop Scan and click OK to abort a scan in process.

Extended Depth Imaging or Image Fusion or Z Slices Reconstruction: Activate EDI by clicking Fusion Off upon which the manual button and the set start and end buttons are activated. Adjust start focus value manually until features are on the verge of blurring and click Set Start. Adjust Z through clear focus and until image starts to blur again and click Set End. Select the number of slices.

Click Auto Scan and the Scan Profile window will pop up. Continue if no changes are required and the individual images and fused images will be acquired and stored in the main directory indicated below the image panel (:Z/HTXL/ in this example). Scanning selected wells: If you wish to scan only a few wells, you may select them in the grid by right clicking them one at a time or dragging the cursor while holding the CTRL key and left button on the mouse. Right click on any well to remove it. With this approach, you can select any combination of wells for scanning. See the example below. The selection will remain active until Clear Selection is pressed. All drops within selected wells will be scanned.