Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Similar documents
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Horizontal Jet Pumps 1/3-1-1/2 HP

MODEL INSTALLATION INSTRUCTIONS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

300 Series PA Pump and Cooler Assemblies

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

APCO SLOW CLOSING AIR/VACUUM VALVES

MAC-120HE-01 Air-Cooled Chiller

What Does A Sump Pump Do?

Fire Pump Plan Review March 2010

Goulds Water Technology

Pump Maintenance - Repair

CRN A-F-G-E-HQQE 3x400D 50 HZ

Explosion-Proof Electric Unit Heaters

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

1/3 HP Submersible Sump Pump with Vertical Float Switch

Multistage high-pressure multistage centrifugal pumps

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

BOWIE PUMPS OPERATION - MAINTENANCE

Dry Pit Solids Handling Pumps

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Series description: Wilo-Drain TC 40

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

HORIZONTAL PUMPING SYSTEM

Model 1210C Battery Powered Pump Shown. Description

Project: Model: Chk d: Date: Model 32DGUII61.5S

Morrison Bros. Co. General Product Specifications

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Frequently Asked Questions Generators

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

WGL20, WGL20H, WGL20F Grinder Pumps

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

BASIS RANGE TMB SERIES

AC Electric Motors best practice

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Multi-Pitch Pitching Machine USER MANUAL

accidents which arise due to nonobservance and the safety information herein.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

Conlift1, Conlift2, Conlift2 ph+

PRESSURE REDUCING CONTROL VALVE

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Transformer oil cooler ALFA A02

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

TECHNICAL INFORMATION Bulletin

CRK A-W-A-BUBV

REGULATORS 175/153 Series

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

American- Darling 5¼" B-84-B-5.

SELECTION, APPLICATION AND MAINTENANCE

Wilo Building Services - Price Book

Tube Type Oil Skimmer Comparison

Laing industrial pumps

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Basic Nameplate Information

HYDROSTATIC TEST PUMPS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

TROUBLESHOOTING GUIDE

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

FAIRBANKS NIJHUIS FIRE PUMPS.

Dehumidifier Users manual. For Models: DH45S DH65S

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

COMPRESSED AIR DRYER

Installation, Operating and Maintenance Instructions

Pumps SELECTION OF A PUMP

ROOF TOP MOUNTED Air Handler Specification

Midwest Industrial Tanks

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

SECTION AIR CONDITIONING UNIT

Specifications SHA Series

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

MDT5N25 & MTD5N40 SERVICE PARTS

Brushless DC Motor Controller Product Specification Assembly 025F0129

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

OUTPUT CABLE CONNECTIONS:

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Transcription:

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Dimensional Data 405 SERIES DIMENSIONAL 405_P2 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Electrical Data MODEL HP VOLTAGE PHASE FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 405 1/2 115 1 7.3 16 140 C / 284 F F 10 2 YES 405-HV 1/2 208/230 1 3.5 7 140 C / 284 F F 10 2 YES 405-Series Technical Data IMPELLER VORTEX HIGH TEMPERATUER ENGINEERED POLYMER SOLIDS HANDLING 3/8 PAINT (PUMP) MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING VOLUTE SHAFT HARDWARE ORINGS SHAFT SEAL WEIGHT TANK MATERIAL INLET SIZE DISCHARGE SIZE VENT SIZE POWDER COAT 82 C / 180 F CLASS F 155 C/ 311 F 140 C/ 284 F SJTOOW DEEP FINNED POWDER COATED ALUMINUM ENGINEERED POLYMER STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP WITH STAINLESS SPRINGS 23 LBS POLYPROPYLENE 405_P3 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) commercial drain pumps as specified herein. The pump models covered in this specification are Series 405 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps, and have a maximum fluid temperature rating of 180 degrees F. 2.01 OPERATING CONDITIONS: Each drain pump shall be rated at 1/2 hp volts, single phase, 60 Hz. 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The drain pump shall be capable of handling effluent with 3/8 solid handling capability. The drain pump shall have a shut-off head of 34 feet and a maximum flow of 48 GPM @ 5 feet of total dynamic head. The pump shall be controlled with a piggy back style on/off float switch. 3.01 CONSTRUCTION: Each drain pump shall be equal to the certified Series 405 SERIES pumps as manufactured by Liberty Pumps, Bergen NY. The motor housing shall be constructed of a deep finned powder coated aluminum. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The tank shall be made of polypropylene. 4.01 ELECTRICAL POWER CORD The drain pump shall be supplied with 10 feet of multiconductor power cord. It shall be cord type SJTOOW, capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class F insulated, NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 155 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 405_P4 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be molded engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All units are supplied with CSA and UL approved automatic wide angle tilt float switches. The switches shall be equipped with piggy back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. The switches shall be mounted under a separately sealed access cover and tethered to a removable stainless steel rod for easy removal and serviceability. 10.01 PAINT The exterior of the casting shall be protected with powder coat paint. 11.01 SUPPORT The polyolefin tank shall be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 14.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 15.01 WARRANTY Standard limited warranty shall be 3 years. 405_P5 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.