How To Know If You Can Get A Drink Of Water

Similar documents
Bacteria Control Troubleshooting Guide for Automated Watering Systems

Water Quality For Poultry

Parts per million (ppm) or Milligrams per liter (mg/l): one part by weight of analyte to 1 million parts by weight of the water sample.

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

CENTRAL LABORATORY. Frontline Service : Conduct of Routine Laboratory Analysis. Customer : Government Agencies, FDA Inspectors, Other Stake Holders

Biological Contamination in the HVAC System

WHY IS THIS IMPORTANT?

Pigeon Spike Stainless Economy Bird Spikes Includes specifications for: Pigeon Spike Stainless models, hardware and surface cleaning.

A Guide to Trouble-Free Cooling Towers

CHAPTER V: DISPOSAL OF WASTES CONTAMINATED WITH INFECTIOUS AGENTS

Water System Disinfection

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

Bacteria vs. Virus: What s the Difference? Grade 11-12

Division of Epidemiology, Environmental and Occupational Health Consumer and Environmental Health Services

A little information goes a long way

The Oral Administration of Antibiotics to Research Mice

Lead and Copper Corrosion Control in New Construction [Project #4164]

Basics of UV Disinfection

7- Master s Degree in Public Health and Public Health Sciences (Majoring Microbiology)

Effective Cleaning and Sanitizing Procedures

Edith Cowan University Faculty of Health, Engineering and Science Work Health and Safety Committee

BOIL WATER NOTICE FREQUENTLY ASKED QUESTIONS

More inside :: Tackle even the toughest water treatment piping challenges with

FAMILY PROTECTION FROM WATERBORNE DISEASES

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

Environmental Management of Staph and MRSA in Community Settings July 2008

Supporting Guidance (WAT-SG-41)

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

Clinic Infectious Disease Control

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

AFDO 2010, Norfolk, VA James Marsden Regents Distinguished Professor Jasdeep Saini Kansas State University

Chapter 18: Applications of Immunology

Includes specifications for: Surface Cleaning & Mounting Hardware.

Approaches to Infection Control

Corrosivity of Water Supplies

Extended experimental investigation: The effect of sunlight on the chlorine levels in pools

Isolation and Identification of Bacteria Present in the Activated Sludge Unit, in the Treatment of Industrial Waste Water

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

C-Difficile Infection Control and Prevention Strategies

Bloodborne Pathogens (BBPs) Louisiana Delta Community College

GUIDELINES FOR THE REGISTRATION OF BIOLOGICAL PEST CONTROL AGENTS FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS

Water Management in Helsinki. Water supply. Mikael Sillfors

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

STUDIES ON THE AIR QUALITY IN A DAIRY PROCESSING PLANT

Professional Certification in Biological Waste Management Examination Content, Sample Questions & References

Course Descriptions. I. Professional Courses: MSEG 7216: Introduction to Infectious Diseases (Medical Students)

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

CONTROLLING MICROBIAL GROWTH IN WINE

Notes Chapter 9 Limiting Reagent Sample Problems Page 1

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

The Ultimate Swimming Experience

Lead Understanding Lead Exposure

Overview of the Cattle Immune System 1

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

FACULTY OF MEDICAL SCIENCE

Functions of Blood. Collects O 2 from lungs, nutrients from digestive tract, and waste products from tissues Helps maintain homeostasis

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

Fungi and Industry. Can you think of any products that depend on the use of fungi at any stage during manufacture?

2010 Annual Drinking Water Quality Report Collier County Water Department

water quality 2007 annual report Huntington District Our Customer Charter Dear West Virginia American Water Customer,

Immunity Unit Test Z

Introduction to Microbiology The Microbial World and You (Chapter 1) Lecture Materials for Amy Warenda Czura, Ph.D. Suffolk County Community College

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Public Water System. Consumer Confidence Report Template

Presented By: Fred J. Sánchez Water Quality Operations Supervisor

TECHNICAL REPORT on the disinfection systems in dental unit water lines.

New Jersey Private Well Water Test Reporting Form

Storage-stable Aqueous Solutions of Chlorine Dioxide

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Biological Drain Maintenance Systems

Raw Milk Quality Tests Do They Predict Fluid Milk Shelf-life or Is it time for new tests?

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

Use of Chlorine in the Food Industry

Ozone Inactivation Kinetics of Multiple Antibiotic Resistant Strains of Bacteria in Water.

Selection of Disinfectants for Use in the Pharmaceutical Industry. Tim Sandle Head of Microbiology Bio Products Laboratory

Ultra Violet Disinfection

Total Suspended Solids Total Dissolved Solids Hardness

GCSE COMBINED SCIENCE: TRILOGY

Lab Exercise 3: Media, incubation, and aseptic technique

8 Chemicals from water treatment and distribution

PPM or ORP: Which Should Be Used?

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Mechanical Systems Competency 1.20

Predictive microbiological models

Collection and disposal of wastewater

Guidance Document Infectious Substances

Current methods: late results (2 to 3 days) contamination spread in the distribution system water consumed

Focus on Preventing Disease. keeping an eye on a healthy bottom line. Cattle Industry

Biological Sciences Initiative

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

Purification of Floodwater by Electrolysis

9/16/2014. Michelle Peninger, BSMT, CIC Inova Health System

Transcription:

Revised 11/03 Drinking Water Acidification Edstrom Industries www.edstrom.com 819 Bakke Ave. Waterford, Wisconsin 53185 4230-MI4179

Copyright 2003 Edstrom Industries, Inc. All rights reserved. Other brand and product names are trademarks or registered trademarks of their respective holders. No part of this manual may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of Edstrom Industries. Although we've taken every precaution when preparing this manual, we assume no responsibility for errors or omissions, nor do we assume liability for damages to your system resulting from the use of the information in this manual. Information in this document is subject to change without notice and does not represent a commitment on the part of Edstrom Industries. Edstrom Industries, Inc. 819 Bakke Avenue Waterford, WI 53185-5913 (262) 534-5181 (800) 558-5913 (262) 534-5184 FAX

Laboratory animal drinking water is sometimes acidified continuously for disinfection. Edstrom Industries provides equipment for continuous acidification of automated watering systems (Central Proportioner) and for acidification of bottled water (Bottle Filling Proportioner / Station). This document provides answers to some common questions on the application of acidification for laboratory animals, such as: What ph level should the water be adjusted to? What type of acid should be used? What are the effects of acidified water on laboratory animals? If you have any further questions or comments about acidification and drinking water quality, please contact Edstrom Industries at 800-558-5913. What are the Benefits of Acidification? Low ph water is bactericidal against Pseudomonas aeruginosa (an opportunistic pathogen common in water) and other Gram-negative bacteria. Acidification is used to prevent the spread of bacterial disease among laboratory animals through drinking water. "Acidified water will not eliminate P. aeruginosa from infected mice nor necessarily prevent transfer of organisms from infected to non-infected cagemates via the fecal oral route. However, the elimination of the spread of P. aeruginosa and other bacteria through the water can be expected." (Small, 1983). What ph is Recommended for Animal Drinking Water Disinfection? As a general guideline, drinking water should be acidified to a ph of 2.5 to 3.0. One basis for this ph range is a study by Tanner and Samantha (1992) that concluded "solutions with a ph of 3 or lower had a bactericidal effect within 60 seconds against Pseudomonas aeruginosa and other Gram-negative eubacteria." Some earlier studies on acidified water and animals used a ph as low as 2.0. However, because acidified water is quite corrosive, the ph should not be lower than necessary. What Type of Acid Should be Used to Lower Drinking Water ph? Hydrochloric acid (HCl) is most often used. Hermann (1982) reported using Tetracycline to acidify drinking water. Tetracycline has the advantage of having direct antibiotic activity. Hall (1980) tested the effects of both hydrochloric and sulfuric acid treatment of drinking water on mice. This study found that water treated with sulfuric acid caused more pronounced health effects in irradiated mice than did water treated with hydrochloric acid. The effectiveness of other acids against Pseudomonas aeruginosa can be found in Morton (1983) and Tanner and Samantha (1992). 3

What Piping Materials Can be Used With Acidified Drinking Water? Water acidified to ph 2.5 3.0 is corrosive and must be used only in a system (or in water bottles) totally constructed of corrosion-resistant material. Acceptable materials include 316 stainless steel and plastics. Do not use brass, copper, or a lesser grade (304) of stainless steel. Even type 316 stainless steel, which is quite resistant, will be attacked to some degree by acidified water. Can Any Microbes Grow in Acidified Water? Yes, some microorganisms can multiply in low-ph water and others can survive (but not multiply). "Filamentous fungi and actinomycetes (filamentous bacteria like Nocardia) can adapt and multiply in ph 2 water. Spore-forming bacilli can resist ph of 2; however, they cannot multiply under those conditions." (Meltzer, 1993). Tanner and Samantha (1992) found that solutions with a ph of 3 or lower are bactericidal against Pseudomonas and other Gram-negative bacteria within 60 seconds. This effect was not observed on Gram-positive bacteria and yeasts. Three animal facilities have reported acid-resistant microorganisms to Edstrom Industries: The first facility to report an acid-resistant organism found a fungus and a free living parasite in water acidified to ph 2.8. No exact I.D. was given. The second facility found a filamentous organism with spores in acidified water taken from wall-mounted manifolds that were never flushed. They chlorine sanitized and flushed out the manifolds and this cleared up the microbial growth. The third facility found Penicillium fungi and Exophiala (another fungus) in acidified drinking water. The Penicillium was also present in the incoming water supply. They chlorine sanitized the automated watering system to remove the growth. Automated watering systems that deliver acidified drinking water should be periodically (monthly, quarterly, or annually as required) sanitized and flushed with a 20 ppm chlorine solution to kill acid-resistant microbes. Acid-resistant microorganisms aren t usually a concern with bottled water since the bottles are already washed and sanitized regularly. Caution In an automated watering system, do not acidify chlorinated water below ph 5.0. At lower ph, chlorine will be present as dissolved chlorine gas (Cl 2 ) which may cause swelling of the silicon O-ring in animal drinking valves. Where and When should ph be Measured? Unlike chlorine in water, the ph of acidified water is relatively stable, so samples from various points in an automated watering system should have approximately the same ph. Initially, you will want to verify that samples taken from the farthest ends of an automated watering system have the same ph as samples from the Proportioner outlet. Daily sampling from the Proportioner outlet is recommended to ensure the acidified water is in the acceptable ph range. Or, an in-line ph analyzer can be installed to automatically monitor the treated water s ph. 4

Sample holding time For ph measurements, test a water sample immediately. Do not store samples to be analyzed for ph. What are the Health Effects of Acidified Drinking Water? Health effects on humans In the ph range of 2.5 to 3.0, there is no immediate direct effect of ph in health of humans. Carbonated beverages have ph values between 2.0 to 4.0. The same can be said for foods (ex. apples 2.9 to 3.3) generally on the acid side of the scale. (DeZuane, 1990) Health effects on laboratory animals Several papers have been written on the effects of acidified water on mice. Please refer to the referenced papers for more details. Les (1968): This study of the effect of acidified-chlorinated water (ph 2.5 and 10 ppm chlorine) on reproduction in C3H/HeJ and C57BL/6J mice during a period of 6 months indicated no detrimental effect of the water treatment. Caution In an automated watering system, do not acidify chlorinated water below ph 5.0. At lower ph, chlorine will be present as dissolved chlorine gas (Cl 2 ) which may cause swelling of the silicon O-ring in animal drinking valves. Hall, White, and Lang (1980): In this study, water acidified with either hydrochloric or sulfuric acid to ph levels of 2.0 or 2.5 was given for 6 weeks to normal and immuno-suppressed male, random-bred mice. The only significant changes in both normal and immunosuppressed mice were declines in weight gain and water consumption when the ph was 2.0. Water consumption wasn t effected when the ph was 2.5. Some of the observed changes were greater in the immuno-suppressed animals. When sulfuric-acidified water at ph 2.0 was consumed, the number of bacterial species isolated from the terminal ileum was reduced. Hermann, White, and Lang (1982): In this study, water treated with hydrochloric acid, tetracycline, or sodium hypochlorite was given to mice for 120 days. Mice drinking water acidified to ph 2.0 had lower spleen weights and reduced spleen-tobody-weight ratios, which may reflect a slower growth rate. Overall, consumption of acidified drinking water did not appear to significantly affect the in vivo immune function of mice. They concluded that these additives do not appear to be a serious health hazard to laboratory animals, but they do represent potential experimental variables. Tober-Meyer, Bieniek, and Kupke (1981): The reaction of rats and rabbits to long-term acidified drinking water (ph 2.3 to 2.5) was observed over a 7-month period. The following parameters were studied: growth curves initiated at weaning, haematology, blood glucose, total serum protein, creatinine, electrolytes, and serum enzymes chosen to monitor the function of major organ systems. The results indicated that in rats and rabbits, the acidification of drinking water with hydro- 5

chloric acid to ph 2.3 to 2.5 did not have any adverse effect on the parameters examined. Based on the current evidence, it is unlikely that acidified water represents a serious health hazard to laboratory animals at a ph of 2.5 to 3.0, but it should be evaluated as an environmental variable. What is the Allowable ph Range for Public Water Supplies? The minimum and maximum allowable ph range for potability is 6.5 to 8.5. This range is included in the secondary drinking water parameters of the Safe Drinking Water Act. Secondary maximum contaminant levels are federally non-enforceable and establish limits for contaminants in drinking water that may affect the aesthetic qualities and the public s acceptance of drinking water. Unlike primary drinking water parameters, secondary means not directly related to health. The lower limit for ph is set to minimize corrosivity of water in municipal and residential distribution piping. DeZuane (1990) identified some problems caused by corrosivity: Contaminants like lead and cadmium can be picked up by corrosive water flowing through lead and galvanized pipe. Similarly, copper, iron, and zinc levels can increase when corrosive water is used in copper, galvanized, and unlined ductile and cast iron pipes. Concrete or asbestos-cement pipes are subject to corrosion at low ph that can release asbestos fibers into drinking water. Microorganisms may find protection in corrosive products, a common problem in municipal distribution systems of corrosive water. The reason for establishing a lower ph limit does not apply in a laboratory animal automated drinking water designed to deliver acidified or purified water because all wetted materials are corrosion-resistant stainless steels or plastics. References DeZuane, J. 1990. Handbook of Drinking Water Quality: Standards and Controls, Van Nostrand Reinhold, New York, NY. Hall, J.E., W.J. White, and C.M. Lang. 1980. Acidification of drinking water: Its effects on selected biologic phenomena in male mice. Lab. Anim. Sci. 30:4:643-651. Hermann, L.M., W.J. White, and C.M. Lang. 1982. Prolonged exposure to acid, chlorine, or tetracycline in drinking water: Effects on delayed-type hypersensitivity, hemagglutination titers, and reticulo-endothelial clearance rates in mice. Lab. Anim. Sci. 32:603-608. Les, E.P. 1968. Effect of acidified chlorinated water on reproduction in C3H/HeJ an C57BL/6J mice. Lab. Anim. Care 18:210-213. McPherson, C.W. 1963. Reduction of and coliform bacteria in mouse drinking water following treatment with hydrochloric acid or chlorine. Lab. Anim. Care 13:737-744. 6

Meltzer, T.H. 1993. High Purity Water Preparation For the Semiconductor, Pharmaceutical, and Power Industires. Tall Oaks Publishing, Inc. Littleton, CO. pp. 57-59. Morton, H.E. 1983. Pseudomonas. In: Disinfection, Sterilization and Preservation, 3rd Edn. (Block, S.S., ed.), pp. 401-413, Lea & Febiger, Philadelphia, PA. Small. J.D. 1983. Experimental and Equipment Monitoring. The Mouse in Biomedical Research (H.L. Foster, J. D. Small, and J.G. Fox, eds.), Vol. 3, pg. 90, Academic Press, New York. Tanner, R.S., and J.A. Samantha. 1992. Rapid bactericidal effect of low ph against Pseudomonas aeruginosa. J. of Industrial Microbiology 10:3-4:229-232. Tober-Meyer, B.K., Bieniek, H.J., and I.R. Kupke. 1981. Studies on the hygiene of drinking water for laboratory animals. 2: Clinical and biochemical studies in rats and rabbits during long-term provision of acidified drinking water. Laboratory Animal. 15:111-117. 7