Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...



Similar documents
- White Paper - Data Centre Cooling. Best Practice

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Installation, operation and maintenance manual TX 35A

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

UDSA - UDSBD unit heater

HEATER, AIR CONDITIONING AND VENTILATION

Lesson 36 Selection Of Air Conditioning Systems

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

CE6500 Energy Recovery Ventilator

Integrated Solar Radiant Systems

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Handbook for Basement

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

HVAC Processes. Lecture 7

SWIMMING POOL HEAT PUMP

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Making Your Home Ready For Solar Water Heating

Energy Efficiency HOSPITALITY.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Combi Unit Genius. The energy efficient Building Service Centre

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

RPV - RP - RA air handling units

HEAVY DUTY STORAGE GAS

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Dehumidifier D 850E. - Instruction manual version 02

Installation and maintenance instructions. Danfoss Vent

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

HDA

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Key energy-efficient features of your new home

Operation and Installation Manual. Max Series

ASTACEA4 Inspect complex/central air conditioning systems

Pool Dehumidification Basics

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

1 DESCRIPTION OF THE APPLIANCE

Glossary of Heating, Ventilation and Air Conditioning Terms

Element D Services Heating, Ventilating, and Air Conditioning

FLEXIT S4 R S6 R S7 R

Comparison between Decentralised and Centralised Air Conditioning Systems

Drain Back systems Made in Germany

Managing Heat Stress in Poultry

ECOCIAT. Domestic hot water heat recovery unit

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

imagine SOLAR AIR CONDITIONING MADE EASY

Solar Air Heating. Objectives. Review basics of Solar Air Heating (SAH) systems. Illustrate key considerations for SAH project analysis

Energy savings in the residential area are essential in

Solar Pool Heating Proposal

New Trends in the Field of Automobile Air Conditioning

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Benefits of Cold Aisle Containment During Cooling Failure

Flexit air handling unit K2 R

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

Owner s Manual

Diesel Engine Driven Generators Page 1 of 6

An Introduction to Solar Energy. Applications for Agriculture. State of New York. George E. Pataki, Governor

Energy efficient home design

Test Report No. C829QPEN

The Animal Welfare Act Regulations for the Transportation of Wildlife

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Energy Efficiency. Bars & RestauRants.

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

Energy Saving Tips. They can have a dramatic impact on your bill. The cheapest energy is the energy you don t use.

Energy Efficiency in Buildings

Klosterenga, Oslo, Norway, page - 1

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

High-efficient gas boiler CompactGas

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

The following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!

In addition to the equipment heat load the room / enclosure will also provide heat gains through the building structure and environment.

Module 2.2. Heat transfer mechanisms

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

york air-conditioning products Residential & VRF News 2015

Floor Heating Warehouse.co.uk

Bring the fresh in. Dedicated Outside Air Systems

Photovoltaic System Technology

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

KONRAD. Hybrid Fancoil Series

Lecture No Active summer cooling systems Fan-and Pad cooling system Fog cooling system

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Rooflighting and Glazing

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

We have been working in an ideal climate for thirty years.

The compact unit series

Kobelco Extended Warranty Program.

Accessory Manual Ventilation Section Model Comfort Circle

Elements of Energy Efficiency in Data Centre Cooling Architecture

Transcription:

Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free...

This booklet contains information about SolarVenti Industrial air solar system. The system is patented in the most relevant countries, including throughout Europe, Eurasia, China, Japan, USA, Canada etc.. In Canada and the U.S. are patent used by one of the leading companies in the industry: Energy Concept and marketed under the name Luba. See their website at www.enerconcept.com SolarVenti Industrial can be placed on the roof or ground with no or little slope. For building facades, it is recommended to use the Canadian system Lubi, as SolarVenti A / S dealer in Scandinavia. Table of Contents General information page 2 Principal of collector construction. page 2 Data and specifications...page 3 Applications... page 3 Installation... page 3 Placement on the roof... page 4 Connecting to manifolds with throttle valves... page 5 Anchoring the building... page 5 Connecting to the ventilation system... page 6 Operation of the system... page 7 Recommend airflow... page 7 Efficiency of the collectors... page 7 Temperature rise under different conditions... page 8 Pressure drop across the system... page 8 Cleaning the collector, maintenance... page 9 Filter cleaning... page 9 warranty... page 9 Photo Gallery... page 10

General information SolarVenti Industrial solar air collectors significantly reduces the cost of heating large halls and buildings which require an air exchange. It is highly effective and very easy to install. The main advantage is a system that brings fresh and dry air into the building. The air enters the collector by a patented double-perforated rear wall. The air passes through the absorber which consists of a black technical material that is resistant to high temperature, and which also acts as a filter.. Unique to this collector is how it converts solar radiation to warm, fresh air. The air gap between the back wall and absorber provides sufficient thermal resistance to transfer solar energy to the incoming air, and eliminates the need for isolation. All in all, this is a lighter and more compact solar air collector than seen before, which is also very effective. Another great advantage, which can easily be overlooked is that the filter, which is also the absorber automatically will be cleaned by the solar heat, when the fan is switched off in the sun. When the temperature exceeds 80 degrees, the solar heating is cleaning and disinfecting the felt - which means: zero maintenance. The following descriptions provide technical information for designers and suppliers of SolarVenti Industrial Free air space Perforated back plate 10 mm Polycarbonat Warm air out Absorber felt Fig 1: principal of SolarVenti Industrial air collector

Data: Dimensions L x W x H: 1975 x 1004 x 450 mm Absorber area D x H: 1935 x 964 mm Efficient solar surface: 1.87 m2/element Panel height from the roof: 20-90 cm (depending on the project) Net Weight of an item: 7 kg applications Preheating of new air for industrial, commercial, institutional and agricultural buildings in cold climates. Preheating of air to air heat pumps (heat recovery) "air-air" or 'air-water'. Drying of grains / crops in agriculture. installation When planning the system, the collectors should be orientated as much south as possible. A minor deviation up to max 45 degrees from the south can be compensated by increasing the area. The length of each row can be adjusted as needed to avoid, for example. roof exhaust pipes or chimneys N Ø S Figure 2. Planning the placing on the roof

W N S E Figure 3. Row of SolarVenti Industrial air collectors connected in series The length of the collector areas: The length of a series of solar panels can be a maximum of 20 meters = 10 pcs. SolarVenti Industrial collector. The distance between rows Because the sun's changing position in different seasons, it is necessary to calculate a minimum distance between rows of collectors. This ensures the best solar radiation in all seasons The most critical period is just before the winter solstice, ie between November 21 and 21 January, when the sun is low over the horizon. Recommended minimum distance: Has to be calculated from the current conditions, avoiding as much as possible shade of winter. Also, one should consider the snow in the winter. In regions with much snow the racks should be extended, meaning that the collectors are placed higher above the roof. Choosing a location collectors Sometimes a roof is quite bare, with no obstructions. In most cases, there is something on the roof that should be taken into account. It is important to take account of existing or new ventilation and exhaust systems, chimneys and other Be careful that no other than fresh, clean air is sucked in through the solar air panels.

Connecting to manifold with throttle valves To balance the flow of air in each series of SolarVenti Industrial collector a damper valve is installed at the beginning of each row. Manifold Valve for flow regulation Fig. 4: Regulation of flow Anchoring to the building Industrial SolarVenti solar panels must be anchored to the roof to withstand wind and snow. Selection of materials and anchoring of solar collectors for each project depends on: The size of the roof with space available for solar panels roof construction the roof pitch and type of roofing static roof load Building height and local wind load Is there space between the existing components (ventilation hoods, ventilators, chimneys, etc.) The composition and size of the existing ventilation system If the roof does not allow the anchor directly to the roof construction, it is possible to use anchor rods and steel cables that are connected with each other. The whole system is then fastened to the edge of the roof or the rods can be anchored to the roof or otherwise, so it's completely safe. In some cases it is necessary to anchor the entire system in a single device. So we recommend the use of solid, stabilizing metal rods.

Stabilising steel rods Anchoring W Fig. 5: Anchoring to the roof N S E Connecting to the ventilation system SolarVenti Industrial is connected to the existing ventilation system with pipes that has to be insulated. The collectors are either preheating or heating the fresh air to be blown into the building. A balancing damper for the intake of solar heated air. A balancing damper for the intake of cold fresh air (bypass damper) Two actuators Temperature sensor to the tube (T) Solar and bypass dampers are controlled automatically by the control unit and temperature sensors installed in the ventilation duct. The purpose of the air control system is to prevent overheating of the air inside the building. When the air from the solar panels is too hot, the controller will automatically begin to open the bypass damper. Through the bypass damper flows the cooler air. The system is thus self regulating to maintain a constant indoor temperature by mixing warm and cold air. Existing ventilation system Damper motor Damper for warm air Temperature sensor Regulator By pass damper Figur 6. air regulation system

Operation of the system SolarVenti Industrial air collectors are designed to operate as "open circuit", which means that they heat the fresh air directly from the outside. It is not possible to recirculate the air from inside the building into collectors. SolarVenti Industrial can also be installed in front of an air heat pump, a heat recovery or for the most used air heating systems. In contrast to other solar heating systems, such as water-borne, SolarVenti Industrial requires very little control, etc.. Everything works when the existing ventilation system is turned on. If the existing ventilation is switched on, fresh air is drawn through SolarVenti Industrial collectors, as long as you need new air and heat. When the desired temperature is reached, normally about 20-22 C the regulator begins to mix the cold air in the intake air through the by-pass system. Recommended airflow SolarVenti Industrial solar panels can work with air flow in the range of 20-220 m³ / h / m² of collector area. From an economic perspective, the optimum air flow 100 to 175 m³ / h / m². There are situations where it is required to have a higher temperature rise, such as drying or the usage in connection with a heat pump. In these cases, the air flow is less than 80 m³ / h / m², which results in up to 25 C increase in temperature above ambient temperature. Normally, it does not pay off to increase air flow over the 175 m³ / h / m². Collector efficiency SolarVenti Industrial The efficiency rise when the air flow rise Efficiency in % Air flow: m 3 /h/m 2

Temperature rise depends on air flow and solar radiation Air flow: Temperature rise Solar radiation W/m 2 The same thing shown in another way Air flow Temperature rise Pressure drop on 1 m2 of Industrial collector Pressure drop Pa Messured by: Fraunhofer Institut

Further information Cleaning the collector In most cases, there is enough rain to keep the collectors clean. However, if there is an abnormal accumulation of dust, leaves or other debris on the transparent part, you can manually clean with a soft, wet sponge. Do not use solvents etc. Not more than a little soap. The cleanliness of the filter. This is a particular advantage of the SolarVenti principle. Filter is also the absorber, and the material can withstand very high temperatures (above 200 C o.). When turning off the fan = air passageway through the collectors while the sun is shining, the temperature rises on the felt for over 80 C o. This high temperature for many hours, will have an antiseptic effect on the filter, which is thereby kept clean for years without special effort. Usually, you have turned off the intake of hot air the summer in warm periods when the bypass function is active. Then it comes all by itself. Many years of experience with this technique has shown good results, and SolarVenti A/S work together with knowledge institutes in various countries, to provide documentation and further guidance regarding to this. The preliminary experience indicates that the filters stay cleaner by turning off the fan once in a while in warm periods. Exclusive distributor for Scandinavia: SolarVenti A / S - also applies to Lubi system. warranty See SolarVenti A / S normal commercial terms. Separate 10-year warranty on PC cover in terms of light transmission 14 m2 system at Den jyske Håndværkerskole (Technical scool in Hadsten, Denmark)

SolarVenti A/S Fabriksvej 8 DK 8881 Thorsø, Danmark www.solarventi.dk tlf: 0045 8696 6700