IMO Resolution A.754(18) Fire Resistance Tests Fire Safety Onboard Ships BY



Similar documents
Rules for Classification and Construction Additional Rules and Guidelines

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Tremco Fire Protection Systems Group Technical Bulletin

Terms and Definitions In Canada

INSTALLATION INSTRUCTIONS RISE SEALING SYSTEM FOR MULTI-CABLE TRANSITS

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

TARIFF CODE and updates standard

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

GK Packing System Welding Instructions

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

GPD Rubber Press Seals

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

Free piston Stirling engine for rural development

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

European Organisation for Technical Approvals

A World Class Manufacturer of Induction Bends

Excerpts from the Canadian National Building Code (NBC)

Company and Product Presentation

Report Number BTC 17755F

4 Installation Requirements

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

BRE Global Test Report

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Marine & Offshore Insulation. - products and constructions November 2009

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Solid shape molding is not desired in injection molding due to following reasons.

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Stainless steel cable fixing solutions for critical environments

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

SIGRAFLEX . Properties. Applications

Material test chamber with mechanical convection

Fire Performance Standard

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

Light-Weight Panels. High quality panels.

SCHOTT PYRANOVA Planline System

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

This will also provide you with the knowledge to insure long life for your Investment

Fire Stopping and Sealing Product: Penetration Seals

Sense it! Connect it! Bus it! Solve it! EncoderS

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

Steel Millimetres Length '4,2" Internal Width '8,6" Dimensions Height '10" Door

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

SPREFIX SPRAY INSULATION _ in the marine market.

ENAiKOON ultrasonic fuel-level sensor

COLD Heat Fire

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Aluminium Standard. Technical Data. Included in delivery

EcoTouch Insulation with PureFiber Technology

Fire Testing of Recycled Materials for Building Applications

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Hose and Tube Fittings Series 1-3

Eurooppalainen tekninen hyväksyntä ETA-12/0045 European Technical Approval

Built to Last. Built for Beauty. Good. Solid. Logix. TM

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

NFPA : Basic Requirements for Storage Tanks

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Screw Plug Immersion Heaters

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Terminal Boxes Series 8146

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Perfection in packaging

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

building applications copper - redefined

Portable digital microprocessor thermometers with interchangeable probes

Fire Security Systems

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Code of Practice for fire resisting metal doorsets

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Incubator with mechanical convection

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

TRITON CONTAINER INTERNATIONAL. Reefer Technical Bulletins. Version 4.0

FIREDEX Conventional Fire Panels

Fire Doors Explained. Presented by - Peter Barker

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Light Duty Commercial Electric Water Heater

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Transcription:

IMO Resolution A.754(18) Fire Resistance Tests Fire Safety Onboard Ships BY Hans van de Weijgert MSc MIFireE MBEng Senior Consultant INTERNATIONAL FIRE CONSULTANTS LTD 20 Park Street Princes Risborough Buckinghamshire HP27 9AH - UK Tel: + 44 (0)1844 275500 Fax: + 44(0)1844 274002

Fire is all around Düsseldorf Airport (Germany) King s Cross Underground (UK) Tunnel Fires Gotthard Alpine Tunnel Mont Blanc Tunnel Channel Tunnel Piper Alpha Campos Basin Shipping Fires Limburg Scandinavian Star Diamond Princess

Objective of IMO Resolution A.754(18) Test method for the determination of the fire resistance of separating constructions Steel Bulkheads Steel Decks Separating constructions Steel Divisions, special functions Water tight Flame integrity

Design Criteria Classification A Class B Class C Class Allowable Temperature Rise (unexposed side) Average, T av = 140 C Maximum, T max = 180 C Insulation Classification A-60, A-30, A-15, A-0 (Steel) B-30, B-15, B-0 F-30, F-15, F-0

Test Specimen Size Minimum Dimensions are: 3040 2440 (length Width) Steel Decks 2500 2440 (Height Width) Steel Bulkheads

The Test Specimen Before Heating

Design Consideration Steel Deck or Bulkhead (Orientation of the division) Fire resistance requirement, A0 A60 Dimensions of the conduit sleeve Material Diameter Wall Thickness of pipe Insulation: type, thickness, length Division Pipe Conduit Sleeve

Tricks to Enhance Fire Performance A barrier/plug inside of pipe

LEGEND LOCATION OF THERMOCOUPLES 1(5) 25 EXPOSED 25 1(5) 3(7) Open Blanked Off 4(8) 2(6) EXPOSED Position of the plug in the pipe

Tricks to Enhance Fire Performance Thicker Insulation on the division Fully insulated exposed pipe ends

LEGEND LOCATION OF THERMOCOUPLES 1(5) 25 EXPOSED 25 1(5) 3(7) Open Blanked Off 4(8) 500 2(6) EXPOSED Pipe penetration in accordance with IMO resolution A 754 (18)

Tricks to Enhance Fire Performance Non-rigid steel support construction for pipes

The Test Specimen During Heating Without rigid pipe supports. (pipe supports not strong enough)

The Test Specimen During Heating With fixings in accordance with IMO A 754 (18) for pipe support.

Tricks to Enhance Fire Performance Increasing the length of conduit sleeve (coaming)

Steel Deck Rise Seal Exposed Side Exposed Side a = 88 88 a. Insulation for H120

Exposed Side Seal a. a. Steel Bulkhead Exposed Side a. Insulation for H120

Furnace 1150 C T h o o r 1 r 2 T h i i Air r 3 Insulation Ri R1 R2 R0 Ti T1 T2 T3 T0

Certificates Generalised Weaknesses Density of pipes Insulation Length Thicknesses Position of transit Example A-60

Product Selection Maximum aperture size of penetration Maximum combination of transits Maximum cable/pipe size Density of fill Spacing between cables/pipes Position of transit in deck/bulkhead Use of insulation Test Evidence Deck and/or Bulkhead Classification, ie A-60, A-0 Pipe Construction Material ie Steel, Aluminium, Plastic Wall thickness

Safety Lifetime of Vessel Maintenance Extra cables Removal of cables Cable coating Drilling The Solution Product Development Modification of IMO Resolution Precise and Uniform Approval Certificates

Product Development ACTIFIRE technology Impact on steel construction Deformation Displacement Safety First ORMoney First

Recommendations to IMO Resolution A.754(18) Specify minimum cable configuration Specify the cables to be tested Specify minimum cable fill (Density) Specify insulation, Divisions, Pipes, Length, Thickness Specify Pipe Construction Material limitations, melting points Wall thickness limitation, max?

Reccommendations to the Classification Societies Specify maximum size cable/pipe penetrations Specify spacing between transits Specify position of non-symmetrical transits Level of insulation Specify cable/pipe specifications (limitations) Installation details i.e Instructions, drawings