Leader in Electrics & Automation Variable Frequency Drive / Inverter Starvert ih 30 55kW(40 HP) 3 phase 200 230Volts 30 220kW(40 300HP) 3 phase 380 400Volts, 440 460Volts Automation Equipment
Overview Standard features Contents Overview 02 Features & Selection Guide 04 Specifications 06 Wiring & Terminal Configuration 08 Keypad & Procedure of Setting Data 0 Program Parameter Descriptions 2 Dimension & Braking unit 6 Driveview 20 & Peripheral devices & RFI Filters 8 Dual rated ih, fits for HVAC applications with Space Vector Control KW / Voltage Ratings: 3055kW, 200230VAC, 3 phase 30220kW, 380460VAC, 3 phase Inverter Type : PWM with IGBT CPU : 32bits high speed DSP Control method: Volts/Hertz with Space Vector PWM Technology CT, VT dual ratings Enclosure : IP00 20kHz Carrier Frequency 05400 Output Frequency Removable Keypad(Able to read & write parameters) 6 Multifunction Inputs 5 Multifunction Outputs (3 Opencollectors, 2 Relays) 420mA Analog Output DC Injection Braking Options Dynamic Braking Units Communication Board RS485 FNet ModBusRTU Device Net Profibus Window based operating software(driveview 20) Application Fan/Blower Water/Waste Water Pump Conveyor Parking System Material Handling Industrial Washing Machine Packaging machine Conformity to global standards UL and cul listed for rth America CE marked for Europe Quality process controlled by ISO900, ISO4000 ISO900 ISO4000 02
Overview Standard features Contents Overview 02 Features & Selection Guide 04 Specifications 06 Wiring & Terminal Configuration 08 Keypad & Procedure of Setting Data 0 Program Parameter Descriptions 2 Dimension & Braking unit 6 Driveview 20 & Peripheral devices & RFI Filters 8 Dual rated ih, fits for HVAC applications with Space Vector Control KW / Voltage Ratings: 3055kW, 200230VAC, 3 phase 30220kW, 380460VAC, 3 phase Inverter Type : PWM with IGBT CPU : 32bits high speed DSP Control method: Volts/Hertz with Space Vector PWM Technology CT, VT dual ratings Enclosure : IP00 20kHz Carrier Frequency 05400 Output Frequency Removable Keypad(Able to read & write parameters) 6 Multifunction Inputs 5 Multifunction Outputs (3 Opencollectors, 2 Relays) 420mA Analog Output DC Injection Braking Options Dynamic Braking Units Communication Board RS485 FNet ModBusRTU Device Net Profibus Window based operating software(driveview 20) Application Fan/Blower Water/Waste Water Pump Conveyor Parking System Material Handling Industrial Washing Machine Packaging machine Conformity to global standards UL and cul listed for rth America CE marked for Europe Quality process controlled by ISO900, ISO4000 ISO900 ISO4000 02
Starvert ih Space vector PWM technology The Space vector technology is being adopted in all LG drives It features outstanding performance in its control characteristics It has low total harmonic distortion, low current ripple, low torque ripple, low motor temperature rise, and better voltage utilization It is a basic control platform of the ih The advantages of Space vector PWM technology are being provided in many applications Better Efficiency (Low Iron Loss in Motor) Low Total Harmonic Distortion Low Motor Heat (Extended Motor) Low Torque Ripple Low Current Ripple High Voltage Utilization (59%) Stable & Smooth Operation High and Stable Torque Builtin PI control It is valuable in process control The builtin PI controller controls flow, temperature, pressure, etc through the proportional and integral calculus between the feedback value and reference value in closed loop Convenient and Various Communication Interface The ih can be operated with communication interface such as RS485, ModBusRTU, DeviceNet, Profibus, and FNet, in order to be operated in various circumstances Driveview 20 software is a Window based tool that provides convenience of monitoring and controlling to user The Driveview 20 features a graph monitor, keypad emulator, parameter editor, and text monitor, to help user`s monitoring and controlling of drive It is applicable for all LG drives CT / VT Dual Ratings The ih features dual ratings in order to be used in both of constant torque and variable torque load conditions User can pick the most suitable drive through dual ratings for various load conditions In that way, user can be prevented from using an overpowered drive 03
Features & Selection Guide User friendly easy straight line programming The ih has simple grouping programming flow It enables quick and easy parameter change and monitoring through 32 character two line LCD display keypad High torque in overall speed range The ih has 50% torque at low speed Thus, its torque performance is proved in high duty applications Drive rating selection guide 30 40 SV030iH2 SV030iH4 37 50 SV037iH2 SV037iH4 45 60 SV045iH2 SV045iH4 55 SV055iH2 SV055iH4 00 SV0iH4 90 25 SV090iH4 0 50 SV0iH4 32 SV32iH4 60 25 SV60iH4 220 300 SV220iH4 Drive type nomenclature SV 30 ih 4 LG Starvert drive 030 30kW ig5 ig5 series 2 3 phase 200~230V 037 37kW is5 is5 series 4 3 phase 380~460V 045 45kW ih iv5 ih series iv5 series 220 220kW 04
Starvert ih Specifications 200 ~ 230V Class(40~ HP) Type SV030iH2 SV037iH2 SV045iH2 SV055iH2 Motor rating *) Output ratings Input ratings Weight[kg(lbs)] Constant Torque [HP] Constant Torque [kw] Constant Torque FLA [A] Constant Torque [kva]* 2) Voltage Frequency 40 30 46 22 42(93) 50 37 55 46 3phase, 200to 230V( 0%) 50 to 60Hz( 5%) 42(93) 60 45 68 80 56(23) 55 83 220 56(23) Specifications 380 ~ 400V Class(40~ 300HP) Type SV030iH4 SV037iH4 SV045iH4 SV055iH4 SV0iH4 Motor rating *) Output ratings Input ratings Weight[kg(lbs)] Constant Torque [HP] Constant Torque [kw] Variable Torque [HP] Variable Torque [kw] Constant Torque FLA [A] Constant Torque [kva] *3) Variable Torque FLA [A] Variable Torque [kva] *3) Voltage Frequency 40 30 50 37 6 40 80 52 45(99) 50 37 60 45 50 96 62 3phase, 380 to 400V( 0%) 50 to 60Hz( 5%) 45(99) 60 45 55 9 60 5 74 63(39) 55 00 0 70 25 80 63(39) 00 25 90 52 00 60 03 68(50) Type SV090iH4 SV0iH4 SV32iH4 SV60iH4 SV220iH4 Motor Rating *) Output ratings Input ratings Weight[kg(lbs)] Constant Torque [HP] Constant Torque [kw] Variable Torque [HP] Variable Torque [kw] Constant Torque FLA [A] Constant Torque [kva]* 3) Variable Torque FLA [A] Variable Torque [kva]* 3) Voltage Frequency 25 90 50 0 83 20 228 47 98(26) 50 0 32 223 45 264 70 3phase, 380 to 400V( 0%) 50 to 60Hz( 5%) 98(26) 32 25 60 264 70 330 23 22(269) 25 60 250 85 325 200 36 233 22(269) 300 220 350 280 432 280 477 307 (386) Specifications 440 ~ 460V Class(40~ 300HP) Type SV030iH4 SV037iH4 SV045iH4 SV055iH4 SV0iH4 Motor rating *) Output ratings Input ratings Weight[kg(lbs)] Constant Torque [HP] Constant Torque [kw] Variable Torque [HP] Variable Torque [kw] Constant Torque FLA [A] Constant Torque [kva] *4) Variable Torque FLA [A] Variable Torque [kva] *4) Voltage Frequency 40 30 50 37 6 45 80 60 45(99) 50 37 60 45 56 96 70 3phase, 440 to 460V( 0%) 50 to 60Hz( 5%) 45(99) 60 45 55 9 68 5 86 63(39) 55 00 0 82 25 93 63(39) 00 25 90 52 3 60 20 68(50) * ) Indicates the maximum applicable capacity when using a 4 Pole motor * 2) Rated kva ( 3*V*I) is based on 220V * 3) Rated kva ( 3*V*I) is based on 380V * 4) Rated kva ( 3*V*I) is based on 440V 05
Specifications Type SV090iH4 SV0iH4 SV32iH4 SV60iH4 SV220iH4 Motor rating *) Output ratings Input ratings Weight[kg(lbs)] Constant Torque [HP] Constant Torque [kw] Variable Torque [HP] Variable Torque [kw] Constant Torque FLA [A] Constant Torque [kva] *4) Variable Torque FLA [A] Variable Torque [kva] *4) Voltage Frequency 25 90 50 0 83 36 228 70 98(26) 50 0 200 32 223 66 264 200 3phase, 440 to 460V( 0%) 50 to 60Hz( 5%) 98(26) 32 250 85 264 97 330 246 22(269) 25 60 300 220 325 242 36 270 22(269) 300 220 350 280 432 322 477 356 (386) Common Specifications Output ratings Control Operating Programmable I/O Protective Functions Operating Conditions Max Frequency 05 to 400 Hz Output Voltage 3 Phase, 0 to Input Voltage Control Method Space Vector PWM Frequency Setting Resolution Digital Reference: 00 Hz (Below 00Hz), 0 Hz (Over 00Hz) Analog Reference: 003 Hz / 60Hz Frequency Accuracy Digital: 00% of Maximum Output Frequency Analog: 0% of Maximum Output Frequency V/F Ratio Linear, nlinear, User Programmable Braking Torque (w/o DB) About 20% Overload Capacity CT 50% of Rated Current for Minute, 200% for 05 Second Overload Capacity VT 0% of Rated Current for Minute, 50% for 05 Second Torque Boost Manual Torque Boost (0 to 20%), Auto Torque Boost Operation Method Keypad / Terminal / Remote (Optional) Frequency Setting Analog: 0 to 0 V / 4 to 20mA, Digital: Keypad Accel / Decel Time 0 to 6,000 sec, 8 PreDefined (Programmable) MultiStep 8 Preset Operational Speed Jog Jog Operation Operating Function DC Braking, Frequency Limit, Frequency Jump, Slip Compensation, PI Control, Stall Prevention Operating Status Frequency Detection Level, Overload Alarm, Stalling, Over Voltage, Under Voltage, Drive Overheat, Run, Stop, Constant Speed, Speed Searching Start Signal Forward, Reverse Programmable Input 6 Programmable Inputs Programmable Output 5 Programmable Outputs: 2 Form A Contact (NO) Fault Contact Output (A, C, B) 250VAC A, 30VDC A 3 Open Collector Outputs: 24V, 50mA Analog 4 ~ 20mA Meter RPM, Hz, Current, Voltage (Output Pulse: 500Hz, Output Voltage: 0 ~ 0V) Drive Trip Over Voltage, Under Voltage, Over Current, Drive Overload, Fuse Open, Ground Fault, Drive Overheat, Motor Overheat, Main CPU Error Stall Prevention Over Current Prevention Instant Power Loss Less Than 5msec: Continuous Operation, More Than 5msec: Auto Restart (Programmable) Ambient Temp 4 F ~ 04 F (0 C ~ 40 C), CE Certification: 4 F ~ 04 F (5 C ~ 40 C) Storage Temp 4 F ~ 49 F (20 C ~ 65 C) Humidity 90% RH Max (ncondensing), CE Certification: 5 ~ 85% (ncondensing) Altitude Vibration Below 3,300ft (,000m) Below 59m/sec 2 (06 g) Air Pressure 86 ~ 06kPa Application Site corrosive gas, combustible gas, oil mist, or dust Cooling Method Forced Air Cooling Enclosure IP00 International Standards CE Certified, UL Listed (UL508C) 06
Starvert ih Keypad LCD Control Panel PROG The Program Button is used to go into programming mode to change data 32 Character, back lit, LCD display The backlight is adjustable LCD Control Panel ENTER The Enter Button is used to enter changed parameters The button is used to move cursor across the display in a programming mode The Mode Button moves you through the three program groups : DRV, FUN, I/O PROG ENTER FWD The Forward Run Button blinks when the forward drive accels or decels The Up and Down Arrows are used to search parameters and change data REV RESET FWD STOP STOP RESET The Stop Button blinks when there is a fault The Reset Button is used to reset faults The Reverse Run Button blinks when the reverse drive accels or decels REV Parameter groups Group name Drive Group Function Group Input/Output Group LCD Keypad(Upper Left Coner) DRV FUN I/O Description Command frequency, Accel/Decel time Etc Basic parameters Maximum frequency, amount of torque boost etc Basic Related Parameters MultiFunction terminal settings Parameters needed for sequence operation Operation method Operation Method Function Function Setting Operation using keypad Operation using Control Terminals Operation using both Keypad and Control Terminals Option Run/Stop command and frequency are set only through the keypad Closing FX or RX terminal performs Run/Stop Frequency reference is set through V or I terminal Run/Stop is performed by the keypad Frequency reference is set through the V or I terminal Closing FX or RX terminal performs Run/Stop Frequency reference is set through the keypad Operation using RS485 communication between drive and computer Operation using ModBus RTU communication between drive and PLC Operation using FNet communication between drive and computer FUN 0: Key FUN 02: Key FUN 0: Terminal FUN 02: Terminal or Terminal2 FUN 0: Terminal FUN 02: Key FUN 0: Key FUN 02: Terminal or Terminal2 FUN 0: Remote FUN 02: Remote I/O 48: RS485 FUN 0: Remote FUN 02: Remote I/O 48: ModBus RTU FUN 0: Remote FUN 02: Remote I/O 48: FNet 09
Keypad & Procedure of Setting Data Procedure of Setting Data ßô To change command frequency from 3000Hz to 4550Hz : PROG DRV Manual K/K 00 REV 3000Hz Press PROG key and the cursor appears on the lowest digit DRV Manual K/K 00 REV 3000Hz DRV Manual K/K 00 REV 3050Hz Press LEFT key once to move digit Press UP key 5 time DRV Manual K/K 00 REV 3050Hz DRV Manual K/K 00 REV 3550Hz Press SHIFT key once to shift the cursor to next digit Press UP key 5 time DRV Manual K/K 00 REV 3550Hz DRV Manual K/K 00 REV 4550Hz Press SHIFT key once to shift the cursor to next digit Press UP key once to make 4 ENTER DRV Manual K/K 00 REV 4550Hz Press ENTER key to store new value The same procedure is applied to all other parameters While the drive is running, the output frequency can be change to a new command frequency *te : Some parameters cannot be changed while the drive is running (refer to the function group table in program parameter descriptions) 0
Starvert ih Parameter navigation Drive Group Function Group I / O Group DRV Manual K/K 00 FWD 6000Hz FUN Jump code 00 4 I/O Jump code 00 DRV Acc time 0 300sec FUN Freq set 0 Key I/O P input 0 SPD_L DRV Dec time 02 600sec FUN Run/stop set 02 Key I/O P2 input 02 SPD_M DRV Current 03 xx A FUN Run prohibit 03 ne I/O P3 input 03 SPD_H DRV Speed 04 xxxrpm FUN Freq max 04 6000Hz I/O P4 input 04 ACCT_L DRV Power 05 575kW FUN Freq base 05 6000 Hz I/O P5 input 05 ACCT_M DRV Fault 06 fault FUN Para lock 98 0 I/O FN:StID 6
Program Parameter descriptions Program parameter descriptions Drive Group Code [DRV] Description of Drive Group Keypad Display Setting Range Units Factory Default Adjustable during run 00 0 02 03 04 05 06 Output Frequency(During Run)or Reference Frequency(During Stop) Acceleration Time Deceleration Time Output Current Output Speed Output Power Display Fault Display Cmd Freq Acctime Dec time Current Speed Power Fault 0 to FUN04 The load current in RMS The motor speed in RPM Inverter Output Power 00 0 0 000 [Hz] 300 [sec] 600 [sec] [A] [rpm] [kw] 2 Function Group Code [FUN] Description of Function Group Keypad Display Setting Range Units 00 Jump to Desired Code # Jump Code to 98 0 Frequency Setting Mode Freqset Key,Terminal, Remote 02 Run / Stop Mode Selection Run/Stop set Key, Terminal,Terminal2, Remote 03 Run Prevention Run prohibit ne, FWD disable, REV disable 04 Maximum Frequency Output Set Point Freqmax 40 to 400 [Hz] 00 05 Base Frequency Freqbase 4 00 06 Starting Frequency Freqstart 05 to 5[Hz] 00 07 Starting Frequency Hold Time Hold time 0 to 0 [sec] 0 08 Volts / Hz Pattern V/F pattern Linear, 20(Squared), User, Auto 09 Torque Boost in Forward Direction Fwd boost 0 to 20 [%] 0 Torque Boost in Reverse Direction Rev boost 0 to 20 [%] Acceleration Pattern Acc pattern Linear, Scurve,Ucurve 2 Deceleration Pattern Dec pattern Linear, Scurve,Ucurve 3 Output Voltage Adjustment Volt control 40 to 0 [%] 4 Energy Savings Level Energy save 30 to 00 [%] 5 Stop Mode Selection Stop mode Decel, DCBR, Free Run 6 User V/F Frequency Userf 0 to 30 [Hz] 00 7 User V/F Voltage Userv 0 to 50 [%] 8 User V/F Frequency 2 User2f FUN 6 to FUN 04 9 User V/F Voltage 2 User2v FUN 7 to 00 [%] 20 Analog Speed Input Selection VI mode V, I, V+I, V2 2 Analog Speed Input Filter Gain Filter gain to 00 [%] 22 Analog Speed Input Gain Analog gain 50 to 250 [%] 23 Analog Speed Input Bias Analog bias 0 to 200 [%] 24 Analog Speed Input Direction Analog dir Direct, Invert 25 Frequency Limit Selection Freq limit, 26 Frequency High Limit Selection Flimit high 00 27 Frequency Low Limit Selection Flimit low 0 to FUN26 00 28 Jump Frequency Selection Freq jump, 29 Jump Frequency Freq jump f 00 30 Jump Frequency 2 Freq jump 2f 00 3 Jump Frequency 3 Freq jump 3f 00 32 Jump Frequency Bandwidth Freq band 0 to 30 [Hz] 00 33 DC Injection Braking Frequency DCbr freq 0 to 60 [Hz] 00 34 DC Injection Braking OnDelay Time DCbr block 05 to 5[sec] 0 35 DC Injection Braking Time DCbr time 0 to 250 [sec] 0 36 DC Injection Braking Voltage DCbr value to 20 [%] 37 Slip Compensation Slip compen, 38 Rated Motor Slip Rated slip 0 to 5 [Hz] 00 39 Rated Motor Current (in RMS) Mrated cur 0 to 999[A] 0 40 Load Motor Current in RMS load cur 0 to 300 [A] 0 4 Inverter Capacity Inv Capacity SV030iH2 SV037iH2 SV220iH4 42 Number of Auto Restart Retry number 0 to 0 43 Delay Time Before Auto Restart Retry time 0 to 0 [sec] 0 44 Fault Output Relay(A, B, C) Relay mode Retry0, All Trips, LV+Retry0, LV+All Trips Factory Default 4 Key Key ne 60 [Hz] 60 [Hz] 05 [Hz] 00 [sec] Linear 2 [%] 2 [%] Linear Linear 00 [%] 00 [%] Decel 000 [%] 5 [%] 3000 [%] 50 [%] V 25 [%] 00 [%] 0 [%] Direct 6000 [Hz] 000 [Hz] 000 [Hz] 2000 [Hz] 3000 [Hz] 500 [Hz] 05 [Hz] 2 [sec] 05 [sec] [%] 000 [Hz] 030 [A] *9) 0 [A] SV030iH2 *0) 0 0[sec] Retry 0 Adjustable during run 2
Starvert ih 2 Function Group Code [FUN] Description of Function Group Keypad Display Setting Range Units 45 46 47 48 49 50 5 52 53 54 55 56 57 58 59 60 6 62 63 64 65 66 67 68 69 70 7 72 94 *2) 95 96 97 98 Stall Prevention Mode Stall Prevention Level Overload Warning Level Overload Warning Hold Time Over Current Trip Limit Level Over Current Limit Time Electronic Thermal Selection Electronic Thermal Level Electronic Thermal Characteristic (Motor Type) Selection Number of Motor Poles IPF (Instant Power Failure) Restart Selection Speed Search Acceleration Time Speed Search Deceleration Time Speed Search Gain Restart after Fault Reset Selection PowerOn Start Selection Carrier Frequency PI Control Selection PI Proportional Gain PI Integral Gain PI Feedback Selection PI Feedback Filter Gain PI Feedback Gain PI Feedback Bias PI Feedback Direction PI I Gain Scale PI Controller Error Direction PI Control Bypass CT/VT Selection Read Parameters into Keypad from Drive Write Parameters to Drive from Keypad Initialize Parameters to Factory Default Settings Parameter Write Protection Stall mode Stall level OL level OL time OC lim level OC lim Time ETH select ETH level Motor type Pole number IPF select SS acc time SS dec Time SS gain RSTrestart Power on st Carrier Freq PIcontrol Pgain Igain PIfb select PIfb filtg PIfb gain PIfb bias PIfb dir I_term scale PI error dir Regul bypass CT/VT Para Read Para Write Para Init Para Lock ne, Acc, Steady, Acc + Steady, Dec, Acc + Dec, Dec + Steady, Acc + Dec+Steady CT: 30 to 50 [%] VT: 30 to 50 [%] CT: 30 to 50 [%] VT: 30 to 0 [%] to 30 [sec] CT: 30 to 200 [sec] VT: 30 to 50 [sec] 0 to 60 [sec], 30 to 50 [%] General, Special 2 to 2, 0 to 600 [sec] 0 to 600 [sec] 0 to 200 [%],, 2 to 0 [Hz], to 30000 to 30000 I, V, V2 to 00 [%] 50 to 250 [%] 0 to 200 [%] Direct,Invert to 00 [%] Direct,Invert, Constant Trq,Variable Trq,,, 0 to 255 0 0 0 0 0 Factory Default ne 50 [%] 0 [%] 50 [%] 0 [%] 0 [sec] 60 [%] 0 [%] 60 [sec] 50 [%] General 4 5 [sec] 0 [sec] 00 [%] 6 [Hz] *) 0 50 I 25 [%] 000 [%] 000 [%] Direct 00 [%] Direct Constant Trq 0 Adjustable during run * 9) Default value depends on the drive capacity * 0) FUN 4 is set at its drive capacity before shipping outside However, drive loses its capacity information after parameter initialization in FUN 97 If the parameters are initialized, be sure to reset the drive capacity to the right capacity * ) Carrier Frequency according to the drive Capacity (The Carrier Frequency is set to 3kHz for VT Rating) type SettingRange Factory Default type SettingRange Factory Default SV030iH2 2 to 0 6kHz SV0iH4 2 to 7 6kHz SV037iH2 2 to 0 6kHz SV090iH4 2 to 6 6kHz SV045iH2 2 to 8 6kHz SV0iH4 2 to 6 6kHz SV055iH2 2 to 8 6kHz SV32iH4 2 to 5 5kHz SV030iH4 2 to 0 6kHz SV60iH4 2 to 4 4kHz SV037iH4 2 to 0 6kHz SV220iH4 2 to 4 4kHz SV045iH4 2 to 8 6kHz SV35iH4 2 to 4 4kHz SV055iH4 2 to 8 6kHz SV3iH4 2 to 4 4kHz * 2) VT is available only for 440V class inverter 3
Program Parameter descriptions Program parameter descriptions 3 I / O Group Code [I/O] Description of I / O Group Keypad Display Setting Range Units 00 0 02 03 04 05 06 07 08 09 0 2 3 4 5 6 7 8 9 20 2 22 23 24 25 26 27 28 29 30 3 32 33 34 35 36 37 38 39 40 4 42 43 44 45 46 47 48 49 50 * 3) 5 52 53 54 55 56 57 58 59 60 6 Jump to Desired Code # Multifunction Input (P terminal) Multifunction Input 2 (P2 terminal) Multifunction Input 3 (P3 terminal) Multifunction Input 4 (P4 terminal) Multifunction Input 5 (P5 terminal) Multifunction Input 6 (P6 terminal) Multifunction Output (OC terminal) Multifunction Output 2 (OC2 terminal) Multifunction Output 3 (OC3 terminal) Multifunction Output 4 (Aux Relay term) Multifunction Output 5 (Aux 2 Relay term) Jog Frequency Step Speed Step Speed 2 Step Speed 3 Step Speed 4 Step Speed 5 Step Speed 6 Step Speed 7 Acceleration Time Deceleration Time Acceleration Time 2 Deceleration Time 2 Acceleration Time 3 Deceleration Time 3 Acceleration Time 4 Deceleration Time 4 Acceleration Time 5 Deceleration Time 5 Acceleration Time 6 Deceleration Time 6 Acceleration Time 7 Deceleration Time 7 Output Voltage / Current Meter (LM Meter) Selection Output Voltage / Current Meter (LM Meter) Adjustment (5V Pulse) FM Meter Output Adjustment (5V Pulse) IO Meter Output Adjustment (4 to 20mA) Frequency Steady Level Frequency Detection Level Frequency Detection Bandwidth Multiplier Constant for Speed Display in 'DRV 04' Divider Constant for Speed Display in 'DRV 04' Status of Input Terminals Status of Output Terminals Software Version Fault History Fault History 2 Option Selection Option 2 Selection Drive number for Option Baud rate for Option Communication Timeout PG Slip Frequency for PG Option PGP Gain for PG Option PGI Gain for PG Option PGFilter Gain for PG Option Encoder Selection for PG Option Digital Input for DI/DA Option Analog Output for DI/DA Option Analog Output Adjustment Drive Number for FNet Jump Code P Input P2 Input P3 Input P4 Input P5 Input P6 Input OC Output OC2 Output OC3 Output AUX Output AUX2 Output Jog freq Step freq Step freq2 Step freq3 Step freq4 Step freq5 Step freq6 Step freq7 Acc time Dec time Acc time2 Dec time2 Acc time3 Dec time3 Acc time4 Dec time4 Acc time5 Dec time5 Acc time6 Dec time6 Acc time7 Dec time7 Analog meter Analog adj FM adj DAC adj FSTfreq FDTfreq FDTband Mul Factor Div factor Ter Input Ter Output S/W version Last fault Last fault 2 Option Option 2 Inv Number Baudrate Comm Timeout PG Slip Freq PG PGain PG IGain PG FGain Enc pulse DI Mode DA Mode DA adj FN:StID to 60 SPD_L,SPD_M,SPD_H, JOG,ACCT_L,ACCT_M, ACCT_H,UP,DOWN, HOLD,DIS_OPT, COMM_CONN,EXT_DCBR, EXT_TRIP SPD_L FST_LO,FST_HI,FDT_HI, FDT_PULSE,FDT_BAND, OL,STALL,LV,RUN,COMM, STEP_L,STEP_M,STEP_H, Voltage,Current 0 to 20 [%] 0 to 20 [%] 0 to 20 [%] 0 to 30 [Hz] 0 to 999 to 999 Fault Status, Freq at Fault, Current at Fault ne,rs485,modbus RTU,FNet ne, MMC to 32 200,2400,4800,9600,9200 0 to 60 [sec] 0 to 0 [Hz] 0 to 225 0 to 225 0 to 225 00,500,52,000,024,2000,2048,4000 ne,freq,freq 2 Freq,Voltage,Current 80 to 20 [%] to 63 00 00 00 00 00 00 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 Factory Default SPD_L SPD_M SPD_H ACCT_L ACCT_M ACCT_H STEP_L STEP_M STEP_H COMM COMM 3000 [Hz] 000 [Hz] 2000 [Hz] 3000 [Hz] 4000 [Hz] 5000 [Hz] 4600 [Hz] 3700 [Hz] 0 [sec] 0 [sec] 20 [sec] 20 [sec] 30 [sec] 30 [sec] 40 [sec] 40 [sec] 50 [sec] 50 [sec] 60 [sec] 60 [sec] 70 [sec] 70 [sec] Voltage 00 [%] 00 [%] 00 [%] 050 [Hz] 6000 [Hz] 00 [Hz] 00 00 200 ne ne 9600 BPS 00 [Sec] 500 [Hz] 00 52 Pulse Freq Freq 00 [%] Adjustable during run * 3) Operation related parameters(fun50 ~ FUN6) Please refer to specific option manual 4
! Starvert ih Dimension(mm) VARIABLE FREQUENCY DRIVE H2 H W3 W2 W D2 D (unit : mm) Class Type W W2 W3 H H2 D D2 SV030iH2 3 360 2 65 5935 2775 2305 SV037iH2 3 360 2 65 5935 2775 2305 200230V SV045iH2 3 360 2 780 85 3007 2305 SV055iH2 3 360 2 780 85 3007 2305 SV030iH4 350 392 270 680 662 3082 2566 SV037iH4 350 392 270 680 662 3082 2566 SV045iH4 3 3596 2 780 7605 326 259 SV055iH4 3 3596 2 780 7605 326 259 SV0iH4 3 3596 2 780 7605 326 259 SV090iH4 530 507 430 780 762 335 2862 380460V SV0iH4 530 507 430 790 762 335 2862 SV32iH4 530 507 430 000 982 345 298 SV60iH4 530 507 430 000 982 345 298 SV220iH4 680 649 540 998 9685 403 343 5
Dimension & Braking unit Braking unit Model name Max DC Input Voltage Capacity Required resistor Applicable type & braking resistor combination Braking torque 50% Enable duty 5% ED Output signal Protection SV030iH2 SV037iH2 SV045iH2 SV055iH2 SV030iH4 SV037iH4 SV045iH4 SV055iH4 SV0iH4 SV090iH4 SV0iH4 SV32iH4 SV60iH4 SV220iH4 SV037DBH2 SV037DBH4 SV0DBH4 DC 400V (200V class) DC 800V (400V class) 37kW / 200V 37kW / 400V kw / 400V 5kW 3 5kW 2 0kW 6 unit (x5kw 3 ) unit (x5kw 3 ) Parallel 2 units (2x5kW 3 ) Parallel 2 units (2x5kW 3 ) unit (x5kw 2 ) unit (x5kw 2 ) unit (2x5kW 2 ) unit (2x5kW 2 ) unit (2x5kW 2 ) Parallel 2 units (4x5kW 2 ) Parallel 2 units (4x5kW 2 ) Parallel 2 units (4x5kW 2 ) Parallel 2 units (4x5kW 2 ) 50% 5% ED Fault output contact, Slave control signal Heat sink overheat, Inverter Overheat RS485 / ModbusRTU Category Performance Hardware Communication Item Specifications Communication method RS485 Transmission form Multidrop Link System Applicable type ih series Computer PC or FA computer (needs RS232485 converter) Number of drives Maximum 32 drives connectable Transmission distance Max 200m Installation On control PCB inside the drives Power Supply Control 5V DC from drive main PCB Communication 5V DC Max00mA (contained in Communication card) Communication speed 9200/9600/4800/2400/200 bps selectable Control procedure Asynchronous communication system Communication system Half duplex system Character system RS485 : ASCII (8 bit) / ModBusRTU : Binary Stop bit length bit Sum check 2 bytes Parity check ne Fnet Item Specifications Communication speed M bps Communication type Manchester BiphaseL, Frame Synchronous type Cable Twisted Pair Shielded Cable Name : LIRECAMESB ø(pc 77 6705) Manufacturer : LG Cable of node Max 64 per line Distance Max 0m Frame Format FieldBus (IEC TC65/SC65C/WG6 65C 908) 6
Starvert ih Driveview 20 Versatile, EasytoUse Software for LG Drives Provides Intuitive Means for Monitoring, Control and Commissioning of Drives Runs on RS232/485 Serial Network Connection Designed for Microsoft Windows 95 or later Keypad Emulator Graphic Monitor Parameter Editor Text monitor Peripheral devices Type kw Breaker Magnetic contactor Power terminal wire(mm 2 ) Earth Line (mm 2 ) DC reactor AC reactor Fuse SV030iH2 SV037iH2 SV045iH2 SV055iH2 SV030iH4 SV037iH4 SV045iH4 SV055iH4 SV0iH4 SV090iH4 SV0iH4 SV32iH4 SV60iH4 SV220iH4 30 ABS203/225 GMC50 60 22 035mH, 520A 008mH, 342A 50A 37 ABS203/225 GMC80 60 22 030mH, 800A 007mH, 606A 200A 45 ABS403/300 GMC220 00 38 028mH, 220A 006mH, 980A 250A 55 ABS403/350 GMC300 00 38 025mH, 2700A 005mH, 2420A 300A 30 ABS203/25 GMC85 22 4 9mH, 760A 033mH, 67A 00A 37 ABS203/50 GMC00 22 4 098mH, 930A 027mH, 825A 00A 45 ABS203/ GMC25 38 22 089mH, 20A 022mH, 00A 00A 55 ABS203/225 GMC50 38 22 0mH, 350A 08mH, 20A 50A ABS203/225 GMC80 60 22 044mH, 870A 03mH, 672A 200A 90 ABS203/300 GMC220 60 38 035mH, 2250A 0mH, 203A 250A 0 ABS403/300 GMC300 80 38 030mH, 2740A 009mH, 2453A 300A 32 ABS/403/400 GMC400 00 38 026mH, 3240A 008mH, 2904A 300A 60 ABS603/500 GMC400 00 60 022mH, 3990A 006mH, 3575A 400A 220 ABS603/600 GMC600 00x2 60 500A 7
Driveview 20 & RFI Filter RFI Filter IH Series Standard Filter type Power Code Current Voltage Leakage Current Dimensions L W H Mounting Y X Weight Mount Output Chokes THREE PHASE SV030iH2 SV037iH2 SV045iH2 SV055iH2 SV030iH4 SV037iH4 SV045iH4 SV055iH4 SV0iH4 SV090iH4 SV0iH4 SV32iH4 SV60iH4 SV220iH4 30kW 37kW 45kW 55kW 30kW 37kW 45kW 55kW kw 90kW 0kW 32kW 60kW 220kW FET502 FET702 FET2302 FET2802 FET0702 FET002 FET202 FET702 FET2302 FET2802 FET4002 FET4802 50A 70A 230A 280A 70A 00A 20A 70A 230A 280A 400A 480A 250VAC 250VAC 250VAC 250VAC 380VAC 380VAC 380VAC 380VAC 380VAC 380VAC 380VAC 380VAC m MAX 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 3A 50A 480 X 200 X 60 480 X 200 X 60 580 X 250 X 205 580 X 250 X 205 350 X 80 X 90 425 X 200 X 30 425 X 200 X 30 480 X 200 X 60 580 X 250 X 205 580 X 250 X 205 700 X 370 X 250 700 X 370 X 250 468 X 66 468 X 66 560 X 70 560 X 70 338 X 46 408 X 66 408 X 66 468 X 66 560 X 70 560 X 70 640 X 300 640 X 300 FS3 FS3 FS4 FS4 FS3 FS3 FS3 FS3 FS4 FS4 FS4 FS4 FF Series (Footprint) FE Series (Standard) H Y H Y W X RED CARGA W X L L FS Series (output chokes) D H Y X W Type FS FS2 FS3 FS4 D 2 285 48 58 W 85 05 50 200 H 46 62 0 70 X 7 90 25 x 30 80 x 45 O 5 5 5 5 8
Leader in Electrics & Automation Safety Instructions For your safety, please read user's manual thoroughly before operating Contact the nearest authorized service facility for examination, repair, or adjustment Please contact a qualified service technician when you need maintenance Do not disassemble or repair by yourself! Any maintenance and inspection shall be performed by the personnel having expertise concerned wwwlgiscom HEAD OFFICE LG TWIN TOWERS, 20 Yoidodong, Youngdungpogu, Seoul, 5072, Korea Tel (822)37774643~4649 Fax (822)37774879, 7804885 http://wwwlgiscom http://wwwfasolutioncom Specifications in this catalog are subject to change without notice due to continuous product development and improvement 2004 AUG Global Network LG Industrial Systems Tokyo Office Japan Address: 6F, HigashiKan, Akasaka Twin Towers 722, 2chome, Akasaka, Minatoku Tokyo 078470, Japan Tel: 833582928 Fax: 8335820065 email: dongjins@lgiscom LG Industrial Systems Dubai office UAE Address: POBox426, API World Tower, 303B, Sheikh Zayed road, Dubai, UAE Tel: 9743328289 Fax: 9743329444 email: hwyim@lgiscom LGVINA Industrial Systems Co, Ltd Vietnam Address: LGIS VINA Congty che tao may dien VietHung Dong Anh Hanoi, Vietnam Tel: 8448820222 Fax: 8448820220 email: srjo@hnvnnvn LG Industrial Systems Hanoi Office Vietnam Address: Room C2, 5Th Floor, Horison Hotel, 40 Cat Linh, Hanoi, Vietnam Tel: 8447366270/ Fax: 8447366269 Dalian LG Industrial Systems Co, Ltd China Address: 5 Liaohexi 3 Road, economic and technical development zone, Dalian, China Tel: 864873820 Fax: 864873060 email: youngeel@lgiscom LG Industrial Trading (Shanghai) Co, Ltd China Address: Room 705707, 7th Floor Xinda Commercial Building 322, Xian Xia Road Shanahai, China Tel: 8626252429 Fax: 86262784372 email: hgseo@lgiscom LG Industrial Systems Beijing Office China Address: Room 303, 3F rth B/D, EAS 2 XIAO YUN ROAD, Dong San Huan Bei Road, Chao Yang District, Beijing, China Tel: 86064623259/4 Fax: 86064623236 email: sclim@mxceigovcn LG Industrial Systems Shanghai Office China Address: Room 705707, 7th Floor Xinda Commercial Building 38, Xian Xia Road Shanahai, China Tel: 86262784370 Fax: 8626278430 email: sdhwang@lgiscom LG Industrial Systems Guangzhou Office China Address: Room 303, 3F, Zheng Sheng Building, 56, Tian He Bei Road, Guangzhou, China Tel: 862085340 Fax: 8620853408 email: lgisgz@publicguangzhougdcn Starvert ih 2002 4/(02) 2004 08 Printed in Korea STAFF