Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched Metal Halide eon/cold Cathode Motor Low Voltage 1 /4 HP@120V Metal Halide 1/2 HP@277V eon/cold Cathode Motor IH2 IDH2 Input Rating 0.02 A 0.1 A 12 V PWM ITERFACE COTROL Input: 012 V PWM 100240 ITERFACE V 50/60HzCOTROL Switched Input: Output: 100240 100127 V 50/60 Hz Switched Output: 100277 V 50/60 Hz Type 1 Enclosure Ind. Cont. Eq. Listed 243C Input Rating IH 2 0.02A IDH 2 0.1A 012V Output Rating Max. 0.4A Class 2 1/4 HP @ 120 V 1/2 HP @ 277 V Output Rating 012 V Output Rating Max. 0.4 A Class 2 Description Provides capability for a GRAFIK Eye 3000 Series control unit, GP, or LP to switch and dim fluorescent lights that have pulse width modulating (PWM) dimming ballasts. Switches and dims any PWM fluorescent dimming ballast powered by 100277 V that conforms to JISC81202. Switches up to of fluorescent, incandescent, lowvoltage, metal halide neon/cold cathode load. Switches motors up to 1/4 HP @ 100/120 V, 1/2 HP @ 200277 V Up to five PWM interfaces may be connected to one GRAFIK Eye 3000 control unit zone. This allows one zone to control up to five circuits of electronic dimming ballasts or five motors. Switches 100277 V 50/60 Hz power to loads. Requires 100/120 V 50/60 Hz power for internal operations. 1
pwm2 05.30.06 Specifications Standards UL listed Power Load (output) power (phase independent of lighting): 100277 V Input voltage rating (phase independent of lighting control): 100/120 V, 50/60 Hz Switched voltage rating: 100277 V, 50/60 Hz H2 terminal input rating: 200 ma DH2 terminal input rating: 100 ma 12 V PWM output rating: 400 ma sources current only Zone Capacity Up to five PWM interfaces per control unit zone. Key Design Features Complies with Standard UL 508. Provides a PELV (Class 2: USA) isolated 12 V at 1 khz with 400 ma max drive capability PWM output signal that conforms to IEC60929 and JIS C81202. Accepts a phasecontrol constantgate drive fluorescent input signal (100120 V 50/60 Hz) Physical Design Wallmounted, EMAType 1 enclosure, IP20 protection; #16 U.S. Gauge Steel. Indoors only. Weight: 4.25 lbs (2 kg) Mounting Surface mount between 16 in. (40 cm) studs Environment 32104 F (040 C). Relative humidity less than 90% noncondensing. Source/Load Type LowVoltage Metal Halide eon/cold Cathode Motors 1/4 HP @ 100120 V 1/2 HP @ 200277 V Switched Current 100277 V 2
Dimensions and Mounting pwm3 05.30.06 Mount only where ambient temperature is 32104 F ( 040 C); less than 90% noncondensing relative humidity. Allow 4.5 in. (114 mm) between interfaces when mounting several in a vertical layout. Mount so that line (mains) voltage wiring is at least 6 feet (1.8 m) from sound or electronic equipment and wiring. Mount within 7 of true vertical. Internal relays click while in operation; mount where audible noise is acceptable. Four Mounting Holes Diameter 0.25 in. (6mm) 4 mounting holes Diameter: 0.25 in. (6 mm) Four Screws Secure Cover 4 screws secure cover WALL 012 V PWM 12 V ITERFACE PWM COTROL Input: Input: Coopersburg, PA 18036 U.S.A. 100240 V 50/60Hz COOPERSBURG, PA 18036 U.S.A. P10 Switched Output: 100240 G 8 BR CB 100127 V 50/60 Hz 144317 GRXTVI 19 Switched Output: 0791275 100277 V 50/60 Hz Ratings Type 1 Enclosure Ind. Cont. Eq. Load T ype Switched Listed 243C Load Type Switched Input Rating Lowvoltage IH 2 0.02A IDH 2 0.1A Metal Halide eon/cold CathodeLow Voltage 012V Output Rating Motor Metal Halide 1 /4 HP@120V Max. 0.4A Class 2 eon/cold 1/2 Cathode HP@277V Motor 1/4 HP @ 120 V 1/2 HP @ 277 V 11.75 in. (298 mm) 11.75 in. (298 mm) Input Rating IH2 0.02 A 0.1 A IDH2 Output Rating 012 V Output Rating Max. 0.4 A Class 2 12.5 in. 12.50 (318 mm) in. (318 mm) 3.35 in. (85 mm) 1.6 in. (41 mm) 4.0 in. (102 mm) (102 6.10 in. (155 mm) (155 1.3 in. (34 mm) 3.30 in. (84 (84 mm) mm) All dimensions in inches (mm). 3
LUTRO R 220 100 2 DL2/DH2 L1/H1 SL1/SH 1 240V 127V 100 L2/H 2 277V 010V Inputs Load Switched Max 0.3A Wiring From Two s or Circuit Breakers pwm4 05.30.06 Each terminal can accept up to two #12 AWG (2.5 mm 2 ) conductors. H1 is the feed to power the load. H2 (on the control circuit terminals) supplies operating power for the PWM interface. Wire control circuit terminals correctly: Leave second terminal empty. Do not connect 200277 V to H2 terminal. Make sure H2 is on the same phase as DH2 (Dimmed ) from the lighting control. Run separate neutrals for load circuit no common neutrals. s can have different phases and/or voltages. Wiring Diagram A: 100277 V : 2 s L2/H 2 220240V L2/H2 100120V 2 DL2/D H2 L1/H 1 SL1/SH 1 010 Volt Line Voltage: 100277 V H2 is the feed that powers the internal circuitry of the. Use H2 only if your line voltage is 100/120 V. GRX3000 Use 20 A maximum circuit breaker/mcb Dimmed EAR TH/GROUD COECTIOS EUTRA L 100/120 V H2 2 DH2 100277 V H1 connections 12 V PWM Switched PWM Signal Wires DO OT COECT TO LIE VOLTAGE. Lutron is not liable for damage due to miswiring. To additional ballasts (50 max.) 4
LUTRO R 220 100 2 DL2/DH2 L1/H1 SL1/SH 1 240V 127V 100 L2/H2 277V 010V Input s Load Switched Max 0.3A Wiring From One s or Circuit Breaker pwm5 05.30.06 Each terminal can accept up to two #12 AWG (2.5 mm 2 ) conductors. H1 is the feed to power the load. H2 (on the control circuit terminals) supplies operating power for the PWM interface. Wire control circuit terminals correctly: Leave second terminal empty. Do not connect 200277 V Run separate neutrals for load circuit no common neutrals. Use this wiring only if maximum circuit breaker/mcb rating will not be exceeded. Wiring Diagram B: 100/120 V : 1 L2/H 2 220240V L2/H2 100120V 2 DL2/D H2 L1/H 1 SL1/SH 1 010 Volt Line Voltage: 100/120 V H2 is the feed that powers the internal circuitry of the. Use H2 only if your line voltage is 100/120 V. GRX3000 Use 20 A maximum circuit breaker/mcb Dimmed EAR TH/GROUD COECTIOS EUTRAL H2 100/120 V 2 DH2 H1 connections 12 V PWM Switched PWM Signal Wires: DO OT COECT TO LIE VOLTAGE. Lutron is not liable for damage due to miswiring. To additional ballasts (50 max.) H1 is the Switched feed to the load. Use a separate lead to H1 if your line voltage is 100277 V. 5