GRX-PWM Pulse Width Modulation Interface



Similar documents
LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

Switching Power Module

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

Phase-Adaptive Power Module

Control Interfaces. GRAFIKR Systems a LUT-DMX

How To Use A Lutron Power Supply

Remote Power Panels with Breakers

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

HomeWorks QS Processor

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Power Supplies 3. SDN-P DIN Rail Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RF Maestro Local Controls

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Dual Technology Ceiling Mount Sensor

Digital input modules

CompactLogix Power Supplies Specifications

QSE-CI-NWK-E Control Interface

LIEBERT VNSA Installation Sheet

12V Dimmable Driver EL-TMDRVR

QSE-CI-DMX Control Interface

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

LED-INTA-0024V-41-F-O

Electronic Control Devices The European Product Catalogue 2007

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Radiant Temperature Sensor TY7321

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electronic Control Devices The European Product Catalogue 2007

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Product and functional description

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

EFC Frequency converters

HMI display Installation Guide

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Adjustable room thermostat for heating only or cooling only systems

LOXONE 12 Channel Amplifier

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

QuickSpecs. HP 480/277 Volt Solutions. Overview

Three-phase monitoring relay CM-PFE

Surgelogic Surge Protective Device (SPD)

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

T7560A,B,C Digital Wall Module

Emergency lighting units EM powerled

INSTALLATION INSTRUCTIONS

ACS-30-EU-EMDR-10-MOD

15 Series - Electronic step relay and dimmer. Features SERIE

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

CO2 Alarm. Operation. Application

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

HERZ-Thermal Actuators

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

RM4TG20 three-phase network control relay RM4-T - range V

Reference Design. conference rooms

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

1756 ControlLogix Chassis Specifications

Analog signal converters CC-E I/I Current / current isolators

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Lightning Arresters P KVA P KVA. Description & Installation

Quick Connect. quick - simple - efficient.

SECTION LOW VOLTAGE LIGHTING CONTROLS

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Rotary Disconnect Switch Specifications

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

OMX-RS232 Control Interface

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Model: DC-A2IO Advanced HVAC Controller

T7079A,B Solid State Remote Temperature Controllers

Color Mark Sensor with Red or Green LED E3S-VS

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Lighting Control Systems

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Advantium 2 Plus Alarm

Operation Manual. Trans-Flo

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Transcription:

Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched Metal Halide eon/cold Cathode Motor Low Voltage 1 /4 HP@120V Metal Halide 1/2 HP@277V eon/cold Cathode Motor IH2 IDH2 Input Rating 0.02 A 0.1 A 12 V PWM ITERFACE COTROL Input: 012 V PWM 100240 ITERFACE V 50/60HzCOTROL Switched Input: Output: 100240 100127 V 50/60 Hz Switched Output: 100277 V 50/60 Hz Type 1 Enclosure Ind. Cont. Eq. Listed 243C Input Rating IH 2 0.02A IDH 2 0.1A 012V Output Rating Max. 0.4A Class 2 1/4 HP @ 120 V 1/2 HP @ 277 V Output Rating 012 V Output Rating Max. 0.4 A Class 2 Description Provides capability for a GRAFIK Eye 3000 Series control unit, GP, or LP to switch and dim fluorescent lights that have pulse width modulating (PWM) dimming ballasts. Switches and dims any PWM fluorescent dimming ballast powered by 100277 V that conforms to JISC81202. Switches up to of fluorescent, incandescent, lowvoltage, metal halide neon/cold cathode load. Switches motors up to 1/4 HP @ 100/120 V, 1/2 HP @ 200277 V Up to five PWM interfaces may be connected to one GRAFIK Eye 3000 control unit zone. This allows one zone to control up to five circuits of electronic dimming ballasts or five motors. Switches 100277 V 50/60 Hz power to loads. Requires 100/120 V 50/60 Hz power for internal operations. 1

pwm2 05.30.06 Specifications Standards UL listed Power Load (output) power (phase independent of lighting): 100277 V Input voltage rating (phase independent of lighting control): 100/120 V, 50/60 Hz Switched voltage rating: 100277 V, 50/60 Hz H2 terminal input rating: 200 ma DH2 terminal input rating: 100 ma 12 V PWM output rating: 400 ma sources current only Zone Capacity Up to five PWM interfaces per control unit zone. Key Design Features Complies with Standard UL 508. Provides a PELV (Class 2: USA) isolated 12 V at 1 khz with 400 ma max drive capability PWM output signal that conforms to IEC60929 and JIS C81202. Accepts a phasecontrol constantgate drive fluorescent input signal (100120 V 50/60 Hz) Physical Design Wallmounted, EMAType 1 enclosure, IP20 protection; #16 U.S. Gauge Steel. Indoors only. Weight: 4.25 lbs (2 kg) Mounting Surface mount between 16 in. (40 cm) studs Environment 32104 F (040 C). Relative humidity less than 90% noncondensing. Source/Load Type LowVoltage Metal Halide eon/cold Cathode Motors 1/4 HP @ 100120 V 1/2 HP @ 200277 V Switched Current 100277 V 2

Dimensions and Mounting pwm3 05.30.06 Mount only where ambient temperature is 32104 F ( 040 C); less than 90% noncondensing relative humidity. Allow 4.5 in. (114 mm) between interfaces when mounting several in a vertical layout. Mount so that line (mains) voltage wiring is at least 6 feet (1.8 m) from sound or electronic equipment and wiring. Mount within 7 of true vertical. Internal relays click while in operation; mount where audible noise is acceptable. Four Mounting Holes Diameter 0.25 in. (6mm) 4 mounting holes Diameter: 0.25 in. (6 mm) Four Screws Secure Cover 4 screws secure cover WALL 012 V PWM 12 V ITERFACE PWM COTROL Input: Input: Coopersburg, PA 18036 U.S.A. 100240 V 50/60Hz COOPERSBURG, PA 18036 U.S.A. P10 Switched Output: 100240 G 8 BR CB 100127 V 50/60 Hz 144317 GRXTVI 19 Switched Output: 0791275 100277 V 50/60 Hz Ratings Type 1 Enclosure Ind. Cont. Eq. Load T ype Switched Listed 243C Load Type Switched Input Rating Lowvoltage IH 2 0.02A IDH 2 0.1A Metal Halide eon/cold CathodeLow Voltage 012V Output Rating Motor Metal Halide 1 /4 HP@120V Max. 0.4A Class 2 eon/cold 1/2 Cathode HP@277V Motor 1/4 HP @ 120 V 1/2 HP @ 277 V 11.75 in. (298 mm) 11.75 in. (298 mm) Input Rating IH2 0.02 A 0.1 A IDH2 Output Rating 012 V Output Rating Max. 0.4 A Class 2 12.5 in. 12.50 (318 mm) in. (318 mm) 3.35 in. (85 mm) 1.6 in. (41 mm) 4.0 in. (102 mm) (102 6.10 in. (155 mm) (155 1.3 in. (34 mm) 3.30 in. (84 (84 mm) mm) All dimensions in inches (mm). 3

LUTRO R 220 100 2 DL2/DH2 L1/H1 SL1/SH 1 240V 127V 100 L2/H 2 277V 010V Inputs Load Switched Max 0.3A Wiring From Two s or Circuit Breakers pwm4 05.30.06 Each terminal can accept up to two #12 AWG (2.5 mm 2 ) conductors. H1 is the feed to power the load. H2 (on the control circuit terminals) supplies operating power for the PWM interface. Wire control circuit terminals correctly: Leave second terminal empty. Do not connect 200277 V to H2 terminal. Make sure H2 is on the same phase as DH2 (Dimmed ) from the lighting control. Run separate neutrals for load circuit no common neutrals. s can have different phases and/or voltages. Wiring Diagram A: 100277 V : 2 s L2/H 2 220240V L2/H2 100120V 2 DL2/D H2 L1/H 1 SL1/SH 1 010 Volt Line Voltage: 100277 V H2 is the feed that powers the internal circuitry of the. Use H2 only if your line voltage is 100/120 V. GRX3000 Use 20 A maximum circuit breaker/mcb Dimmed EAR TH/GROUD COECTIOS EUTRA L 100/120 V H2 2 DH2 100277 V H1 connections 12 V PWM Switched PWM Signal Wires DO OT COECT TO LIE VOLTAGE. Lutron is not liable for damage due to miswiring. To additional ballasts (50 max.) 4

LUTRO R 220 100 2 DL2/DH2 L1/H1 SL1/SH 1 240V 127V 100 L2/H2 277V 010V Input s Load Switched Max 0.3A Wiring From One s or Circuit Breaker pwm5 05.30.06 Each terminal can accept up to two #12 AWG (2.5 mm 2 ) conductors. H1 is the feed to power the load. H2 (on the control circuit terminals) supplies operating power for the PWM interface. Wire control circuit terminals correctly: Leave second terminal empty. Do not connect 200277 V Run separate neutrals for load circuit no common neutrals. Use this wiring only if maximum circuit breaker/mcb rating will not be exceeded. Wiring Diagram B: 100/120 V : 1 L2/H 2 220240V L2/H2 100120V 2 DL2/D H2 L1/H 1 SL1/SH 1 010 Volt Line Voltage: 100/120 V H2 is the feed that powers the internal circuitry of the. Use H2 only if your line voltage is 100/120 V. GRX3000 Use 20 A maximum circuit breaker/mcb Dimmed EAR TH/GROUD COECTIOS EUTRAL H2 100/120 V 2 DH2 H1 connections 12 V PWM Switched PWM Signal Wires: DO OT COECT TO LIE VOLTAGE. Lutron is not liable for damage due to miswiring. To additional ballasts (50 max.) H1 is the Switched feed to the load. Use a separate lead to H1 if your line voltage is 100277 V. 5