OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Similar documents
Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure transmitter For general industrial applications Model A-10

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Features. Picture. Specifications

Electronic Pressure Monitoring New Products

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Electronic Pressure Switch EDS 3000

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Assisted lift operated 2/2-way solenoid valves Type EV250B

How To Use A Flowmeter

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Turbine Flow Sensor Series VTR

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Data Sheet PS1B Pressure Switch

Datalogger DL/N 70 Version:

psens Pressure Measurement

Electronic Pressure Switch EDS 300

Heavy Duty Pressure Sensors/ Transducers Line Guide

Plastic tube flowmeters Series PT/PS

Relative and absolute pressure switch type 529

Relative pressure transmitter type 520

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Actuators and Sensors. Products

Solenoid valves 2/2-way direct-operated Type EV210A

4 Posiflow Proportional Solenoid Valves

Analog signal converters CC-E I/I Current / current isolators

Digital inductive conductivity transmitter

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Conductive Level Switch FK 2 Technical Data:

Liquid Level Limit Switch liquiphant T FTL 20

Inductive sensor NI10-M18-Y1X-H1141

Flow switches Series AD/VH

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

MicroMachined Silicon modular pressure sensor

OEM Flow sensor type 200 for liquid media

Digital input modules

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Sensors OXYGEN SENSORS PRESSURE SENSORS TEMPERATURE SENSORS ROTARY POTENTIOMETER SPEED SENSORS UEGO LAMBDA BOX STAND-ALONE PRT 02/03/06 P002P010 OPS04

Hand-held thermometer Model CTH7000

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Differential Charge Amplifier

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Digital Pressure Measuring Instrument MDR480

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Electric Rotary Actuator - On/Off or programmable control actuator

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

SITRANS F flowmeters SITRANS F M

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Digital display DA 48

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

How To Use A Corona Mdi 110

Technical Data. Dimensions

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Maximum Input Current Vin=18V, 100% Load A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Hydraulic Control Solutions

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Series description: Wilo-Yonos MAXO

Flow sensor type 210 for liquid media

Honeywell Pressure Switches Line Guide

Centro-Matic Automatic Lubrication Systems System Controls

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

DPI 260 SERIES: Digital Pressure Indicators

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Givare NC-SRS 280 och 880

Duct Humidity Transmitter

VSO MAX HP High Flow Proportional Valve

9000 Series Accelerometers Specifications

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

GRUNDFOS DIRECT SENSORS Flow Measurement

38 Series - Relay interface modules A

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Contents. Document information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Transcription:

MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme consists of two series: y MBS 1200 without integrated pulse-snubber y MBS 1250 with integrated pulse-snubber The integrated pulse-snubber offers a high degree of protection against cavitations and liquid hammer, and the well thought out design results in excellent vibration stability and an exceptional robustness. The high degree of EMI protection equips the pressure transmitter to meet most requirements. Features y Designed for use in severe OEM applications y For medium and ambient temperatures up to 125 C y All standard output signals: 4 20 ma, 0 5 V, 1 5 V, 1 6 V, 0 10 V, 10 90% ratiometric voltage y Wetted parts made of stainless steel y A wide range of pressure and electrical connections y EMC protection up to 100 V/m y Dual output transmitter for further information please contact Danfoss Approvals UL 508 recognized ISO 7637 pulse 1-4 IC.PD.P21.A8.02 / 520B5106

Pulse-snubber in MBS 1250 Application Cavitation, liquid hammer and pressure peaks may occur in liquid filled systems with changes in flow velocity, e.g. fast closing of a valve or pump starts and stops. The problem may occur on the inlet and outlet side, even at rather low operating pressures. The media viscosity has only little effect on the response time. Even at viscosities up to 100 cst, the response time will not exceed 4 ms. Technical data Performance (EN 60770) Accuracy (incl. nonlinearity, hysteresis and repeatability) ± 0.5% FS Thermal zero point shift <± 0.15% FS / 10K Thermal span shift <± 0.15% FS / 10K Response time liquids (10 90%) > 0.5 ms Durability, P: 10 90% FS >10 106 cycles Overload and burst pressure without pulse-snubber (MBS 1200) Nominal pressure [bar] 10 16 25 40 60 100 160 250 400 500 600 1000* 1600* 2200* Overload pressure 30 48 80 80 140 200 320 500 800 1400 1400 2000 2500 3000 Burst pressure 400 640 800 800 1400 2000 1600 2500 4000 >4000 >4000 >4000 >4000 >4000 * Only available with M12 1 1.5 P high pressure port, type FC06. Please contact Danfoss. Overload and burst pressure with integrated pulse-snubber (MBS 1250) Nominal pressure [bar] 10 16 25 40 60 100 160 250 400 500 600 Overload pressure 30 48 120 120 210 300 480 750 1200 2100 2100 Burst pressure 400 640 800 800 1400 2000 1600 2500 4000 >4000 >4000 Electrical specifications Nom. output signal (Short-circuit protected) 4 20 ma (2 wire) 0 5, 1 5 1 6 V 0 10 V 10 90% ratiometric Supply voltage [U B], polarity protected 8 30 V 8 30 V 12 30 V 5 V ± 0.5 V Supply current consumption 4.5 ma 4.5 ma 4.5 ma Output impedance 90 Ω 90 Ω 90 Ω Load [R L ] (connected to 0 V ) See chart below R L 10 kω R L 10 kω R L 5 kω Load [R L ] (connected to + V ) See chart below Not possible Not possible R L 5 kω 4 20 ma output min. / max. resistance vs. supply voltage Current Output (Load Resistor Range) Loop current should not exceed 22 ma continuous or 25 ma temporarily due to pressure peaks. Customer Load Ressistor (Ohms) Max. Resistor (RL) Current Supply Voltage (V) Min. Resistor (RL) 2 IC.PD.P21.A8.02 / 520B5106

Technical data (continued) Environmental conditions Media temperature range - 40 125 C Ambient temperature range See page 5 Compensated temperature range - 40 125 C Transport temperature range -55 150 C EMC Emission EN 61326-2-3 EMC Directive EMC Immunity RF field 100 V/m, 26 Mhz 1 Ghz 3 V/m, 1.4 GHz 2.7 GHz 2004/108/Ec EN 61326-2-3 Cable < 30 m Electrical performance comply with ISO 7637 pulse 1 4, 24V Vibration stability 20 g, 10 2000 Hz, sinus EN 60068-2-6 Shock resistance 100 g EN 60068-2-27 Enclosure (depending on electrical connection) See page 5 Mechanical conditions Materials Wetted parts Enclosure Pressure connection 17 4 PH AISI 304 or plastic 17 4 PH Electrical connection See page 5 Ordering standard MBS 12.. 1 Standard 0 0 Gasket with pulse-snubber 5 0 Defined type of pressureconnection Measuring range 1) (Gauge) 0 10 bar 2 0 Pressure connections (HEX 22 mm) 0 16 bar 2 2 G B 0 4 G ¼ A DIN 3852-E 2) 0 25 bar 2 4 A C 0 4 ¼ 18 NPT 0 40 bar 2 6 A C 0 2 1 8 27 NPT 0 60 bar 2 8 B D 0 8 7 16 20 UNF-2A 2) 0 100 bar 3 0 A F 0 4 ¼ 18 NPTF 0 160 bar 3 2 A F 0 2 1 8 27 NPTF 0 250 bar 3 4 P T 0 4 ¼ 19 PT 0 400 bar 3 6 0 500 bar 3 7 0 600 bar 3 8 Electrical connections C 1 M12 1 EN60947-5-2 Pressure reference C 2 Round Packard Metri-Pack Gauge(relative) 1 C 3 Deutsch DT04-4P C 4 AMP superseal Output signal C 7 Deutsch DT04-3P 4 20 ma 1 0 5 V 2 1 5 V 3 1 6 V 4 1) For pressure range < 10 bar or >600 bar, 0 10 V 5 please contact Danfoss Ratiometric, 10 90% 6 2) Incl. Viton gasket. Min. medium temperature is -25 C IC.PD.P21.A8.02 / 520B5106 3

Dimensions / Combinations* Type code C1 C2 C3 C4 C7 M12 1 EN60947-5-2 Round Packard Metri-Pack Deutsch DT04-4P AMP Superseal 1.5 Deutsch DT04-3P The diameter of all housings is 19 mm. HEX is 22 mm across flats. 7 16 20 UNF-2A 1 4 19 Pt 1 4 18 NPT / NPTF 1 8 27 NPT / NPTF G 1 4 A DIN 3852-E Type code BD08 PT04 AC04/AF04 AC02/AF02 GB04 Recommended torque 2) 18 20 Nm 30 35 Nm * For other combinations please contact Danfoss 2) Depends of different parameters as packing material, mating material, thread lubrication and pressure level. 4 IC.PD.P21.A8.02 / 520B5106

Electrical connections Type code C1 C2 C3 C4 C7 Key M12x1 EN60947-5-2 Round Packard Metri-Pack Deutsch DT04-4P AMP Superseal 1.5 Deutsch DT04-3P Ambient temperature 4 20 ma Ambient temperature, 0 5 V, 1 5 V, 1 6 V, 0 10 V, ratiometric 10 90% Enclosure (IP protection fulfilled together with mating connector) - 40 100 C - 40 100 C - 40 100 C - 40 100 C - 40 100 C - 40 125 C - 40 125 C - 40 125 C - 40 125 C - 40 125 C IP67 IP67 IP67 IP67 IP67 Material SS, PBT 30% GFR Gold (Au) plated GFR Gold (Au) plated Electrical connections, 4 20 ma (2 wire) Pin 1: + supply Pin 2: not connect Pin 3: supply Pin 4: PE, connected Pin A: supply Pin B: + supply Pin C: do not connect Pin 1: supply Pin 2: + supply Pin 3: PE, connected Pin 4: do not connect Pin 1: do not connect Pin 2: supply Pin 3: + supply Pin A: + supply Pin B: supply Pin C: do not connect Electrical connections, 0 5 V, 1 5 V, 1 6 V, 0 10 V, ratiometric 10 90% Pin 1: + supply Pin 2: output Pin 3: supply Pin 4: PE, connected Pin A: supply Pin B: + supply Pin C: output Pin 1: supply Pin 2: + supply Pin 3: PE, connected Pin 4: output Pin 1: output Pin 2: supply Pin 3: + supply Pin A: + supply Pin B: supply Pin C: output Danfoss A/S (IA-MO / jmn), 2012-12 IC.PD.P21.A8.02 / 520B5106 5