OEM Flow sensor type 200 for liquid media
|
|
|
- Joleen McDonald
- 9 years ago
- Views:
Transcription
1 OEM Flow sensor type 200 for liquid media Flow range l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement ÀC The flow sensor Type 200 is based on the arman Vortex principle. You can choose between various versions. The Type 200 is available with or without temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy. Low cost product with high levels of accuracy Temperature non-sensitive measuring principle Excellent media resistance (measuring element not in contact with the media) Wide application temperature range Marginal loss of pressure Measuring element not sensitive to debris Direct temperature measurement in the medium with PT1000 or NTC Drinking water approval TW, W270, WRAS, ACS 1/9
2 Technical overview Flow measurement Measuring principle Vortex Piezoelectric sensor element Measuring range l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Accuracy at < 50% fs (water) < 1% fs Accuracy at > 50% fs (water) < 2% measuring value Response time Immediately Signal delay < 100 ms Therefore suitable for spigot use. Response time < 5 ms Temperature measurement (> DN 8) Measuring principle PT1000 NTC Temperature influences Resistance Measuring range Accuracy Class B DIN EN Measuring range NTC ÀC Accuracy β = 4050 Self-heating at temperature sensor Conduction resistance to T = 0 T 0 T = +25 T < +25 T > +25 ÀC PT1000 NTC ÀC μ 0.3 μ 0.3 μ * ΔT ÀC μ 0.7 μ 0.7 μ * ΔT μ 0.7 μ * ΔT 1 /mw 0.8 Ohm Operating conditions Medium Suitable for heating circuit water with the usual additives Drinking water Other medium on request Media < +125 ÀC Temperature Ambient ÀC Storage ÀC (for lifetime) 12 bar at +40 ÀC (for lifetime) 6 bar at +100 ÀC Max pressure and (for 600 hours) 4 bar at +125 ÀC medium temperature (for 2 hours) 4 bar at +140 ÀC (max. test pressure) 18 bar at +40 ÀC Cavitation The following equation is valid to prevent cavitation: Pabs_oulet / Pdifference > 5.5 Materials in contact with medium (FDA-conform) Sensor paddle Case with damming body Sealing material ETFE PA6T/6I (40% GF) FPM EPDM (perox.) Electrical overview Power supply UIN 5 VDC μ5% Output flow (Q) Frequency Square pulse signal UOUT_Q_Frequency < > 4.75 V Output temperature (T) Resistant signal ROUT PT1000 PT1000 class B DIN EN ROUT NTC NTC ÀC; β = 4050 Electrical connection and protection class Connector RAST 2.5 / 2.54 IP 20 Connector M12x1 IP 65 Load against or IN > 10 kohm / < 10 nf Current consumption I IN load free standard < 6 ma enhanced EMC protection < 10 ma Weight DN 6 / 8 DN 10 DN 15 DN 20 DN 25 Test / Admissions Electromagnetic compatibility Drinking water approval ~ 47 g ~ 57 g ~ 68 g ~ 92 g ~ 100 g acc. to EN (no protection at surge) WRAS Plastic parts with TW and W270 approval ACS Packaging (multiple packaging) Connection copper tube Outside thread Outside thread G DN 6 Blister 30x Blister 30x DN 8 / 10 Blister 30x Blister 30x Blister 30x DN 15 Blister 30x Blister 30x Blister 20x DN 20 Blister 20x Blister 20x Blister 15x DN25 Blister 15x Blister 15x Minimum life span on high flow rate and high temperature Temperature in ÀC Temperatur in C Durchfluss Flow in in %% 2 hours Std 10 hours Std 100 hours Std 0.1 year Jahr 1 year Jahr 10 year Jahre 2/9
3 Nominal diameters dependent variables Nominal diameters DN 6 Tube connection G Measuring range Quantity per 50% fs Flow rate Frequency range Q 0 1), 2) f Pressure drop l/min ml m/s Hz * Q ml Hz DN 8 G l/min ml m/s Hz N ml Hz * Q ml Hz DN 10 G l/min ml m/s Hz N ml Hz * Q ml Hz DN 10 G l/min ml m/s Hz N ml Hz * Q ml Hz DN 15 G l/min ml m/s Hz N ml Hz * Q ml Hz DN 20 G l/min ml m/s Hz N ml Hz * Q 2 DN ml Hz l/min m/s -0.2 G ml Hz * Q 2 Characteristic line formula frequency output Q V = f * + Q 0 Formula quantity per pulse [litres/pulse] quantity = Q V * f pulse 60 * (Q V - Q 0 ) (Influence of viscosity for media other than water - see page 8) Legend Q V Volume flow rate [l/min] Q 0 Axis intercept [l/min] f Coefficient frequency output [(l/min) / ] Frequency [Hz] quantity litres Quantity per pulse pulse pulse 1) incl. 3xDi inlet and outlet side 2) Pv in Pa; Q in l/min 3/9
4 Accessories 2) Order code selection table 200. X X X X X X X Version Nominal diameters / flow range Output / power supply Electrical connection Sealing material Tube connection Flow 9 Flow and temperature (PT1000) 8 1 Flow and temperature (NTC) 7 1 DN l/min ,G DN l/min DN l/min. 1 0 DN l/min. 1 1 DN l/min. 1 5 DN l/min. 2 0 DN l/min. 2 5,G Frequency output, VDC (Square pulse signal) 5 VDC standard 9 0 Frequency output, VDC (Square pulse signal) 5 VDC enhanced EMC protection 1 3-pole connector RAST x3-pole connector RAST 2.5 7, pole connector RAST 2.5 (condensation protection) 9 2 2x3-pole connector RAST 2.5 (condensation protection) 7, pole circular connector M12x1 (condensation protection) pole circular connector M12x1 (condensation protection) 7,8 1 5 EPDM Ethylene propylene rubber (peroxidically cross-linked) 1 FPM 1) Fluoro elastomer 2 connection copper tube (max. DN 20) N Plastic PA6T/6I outside thread (see dimension diagram) outside thread G (see dimension diagram) G Order number Connection kit 3) DN 8, 10 with copper tube Connection kit 3) DN 8, 10 with adapter Rp ⅜ Stainless steel /AISI Connection kit 3) DN 15 with copper tube Connection kit 3) DN 15 with adapter Rp ½ Stainless steel /AISI Connection kit 3) DN 20 with copper tube Connection kit 3) DN 20 with adapter Rp ¾ Stainless steel /AISI Connector RAST 2.5 with cable 3-pole 30 cm Connector RAST 2.5 with cable 3-pole 110 cm Straight-wire box for connector M12x1 with cable 3-pole 200 cm Corner-wire box for connector M12x1 with cable 3-pole 200 cm Connector RAST 2.54 with cable 2x3 pole 110 cm (with temperature) Straight-wire box for connector M12x1 with cable 5-pole 200 cm (with temperature) Corner-wire box for connector M12x1 with cable 5-pole 200 cm (with temperature) Straight-wire box for connector M12x1 screwing terminal 5-pole Clip for DN 8, Clip for DN Clip for DN O-Ring for DN 8, DN 10 EPDM Œ x 2.62 Copper tube and adapter O-Ring for DN 15 EPDM Œ x 2.62 Copper tube and adapter O-Ring for DN 20 EPDM Œ x 2.62 Copper tube and adapter O-Ring for DN 25 EPDM Œ 31 x 3 (as a replacement, already assembled) Connection copper tube for DN 8, 10 L=150 mm Connection copper tube for DN 15 L=150 mm Connection copper tube for DN 20 L=150 mm Adapter for DN 8 und DN 10 Rp ⅜ Stainless steel /AISI Adapter for DN 15 Rp ½ Stainless steel /AISI Adapter for DN 20 Rp ¾ Stainless steel /AISI AMP connector 4) Manufacturers order number Colour for flexible wire grey 7 x 0.20 mm = 0.22 mm 2 12 x 0.20 mm = 0.35 mm beige 7 x 0.25 mm = 0.35 mm 2 1) No drinking water approval 2) Accessories supplied loose 3) Connection set includes: 2x Clip, 2x Copper tube or Adapter and 2x O-Ring 4) To order seperately directly from the manufacturer. Find further information in the manufacturers specification no /9
5 Dimension diagram DN 8, 10, 15, 20 1a 5a 2a 3a 4a 6a 1a 2a 3a 4a 5a 6a DN DN Dimension diagram DN 6, 8, 10, 15, 20, 25 1d 6d 2d 3d 3d 4d 1d 2d 3d 4d 5d 6d DN G ½ DN6 G G ¾ DN G ½ d DN8 G G ¾ DN G ½ DN10 G G ¾ G ¾ G G G G G 1¼ DN G 1¼ DN25 G G 1½ /9
6 Admissible locking torque DN6/8/10 G ½ DN6/8/10 G ¾ G ¾ G1 G1 G1 ¼ DN25 G1 ¼ DN25 G1 ½ M min [Nm] M max [Nm] Accessories DN 8, 10, 15, 20 adapter c inside thread clip 2c o-ring to adapter 4c 3c 7c 6c 5c 8c 9c 1c 2c 3c 4c 5c 6c 7c 8c 9c DN8 22 DN Rp ⅜ DIN 2999 lenght min. 9 Rp ⅜ DIN 2999 lenght min. 9 Rp ½ DIN 2999 length min Rp ¾ DIN 2999 lenght min Geometry of customers connection tube DN 8, 10, 15, 20 o-ring 1b clip 6b 5b 4b bevelled edge min b 7b 3b 8b 9b 1b 2b 3b 4b 5b 6b 7b 8b 9b DN8 Œ 13.95x μ μ 0.2 Œ 13 μ 0.2 Œ μ 0.08 Œ μ DN10 Œ 13.95x μ μ 0.2 Œ 13 μ0.2 Œ μ 0.08 Œ μ Œ 17.86x μ μ 0.3 Œ 16 μ 0.2 Œ Œ 21.89x μ μ 0.3 Œ 20 μ 0.2 Œ Œ μ Œ μ /9
7 Tube mounting instructions Consider the following to ensure the correct function of the sensor. Only diameter changes from large to small are allowed. Avoid repeated elbows in the same level at entryside minimum 5xDN for alternative elbows minimum 0.5xDN for recommended 90À elbow with min. R 1.8xDN Electrical connections IN + OUT Hz RAST 2.5 without temperature output IN + OUT Hz OUT T1 Ω T2 IN Connector 2x3-poles with temperature output OUT IN T2 T1 IN Hz 3 OUT Connector M12x1 without temperature output IN Hz OUT T2 T1 Ω Connector M12x1 with temperature output Pin Colour 1 brown 3 1 blue 4 black 1 brown 2 white 3 2 blue 4 black 5 gray 7/9
8 Influence of glycol With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity > 1.8 cst) in order to reach a measuring accuracy of 3% fs in the range of cst and of 4% in the range of 4-14 cst (υ = viscosity in cst). Definition of viscosity of glycol-water-compound inematic inematische Viskosität Ethylenglykol Wasser viscosity ethylene glycol water inematic inematische Viskosität Propylenglykol Wasser viscosity propylene glycol water Temperature Temperatur in C ÀC % 10% 20% 30% 40% 50% 60% 70% Temperature Temperatur in C ÀC % 10% 20% 30% 40% 50% 60% viscosity Viskosität in cst in viscosity Viskosität in cst in Definition of respond threshold Q min Definition of characteristic line formula Q V = k f * f + Q 0 Minimal Minimal detek rbarer detectable flow Durch uss Ein uss Influence der on Viskosität viscocity Q0auf Q Minimaler flow Durch uss in l/min in l/min DN10 DN25 DN32 characteristic Q0 in ennlinienformel line formula in l/min DN10 DN25 DN viscosity Viskosität in cst in cst viscosity Viskosität in cstin cst Formula respond threshold Q min in l/min < DN 10 not possible DN10: Q min = υ : Q min = υ : Q min = υ + 4 DN25: Q min = υ + 8 Formula characteristic line for Q > Q min in l/min < DN 10 not possible Frequency output: DN10: Q = f * f 0.40υ : Q = f * f 0.45υ : Q = f * f 0.55υ DN25: Q = f * f 0.80υ /9
9 Huba Control AG Headquarters Industriestrasse Würenlos Telefon +41 (0) Telefax +41 (0) Huba Control AG Niederlassung Deutschland Schlattgrabenstrasse Walddorfhäslach Telefon +49 (0) Telefax +49 (0) Huba Control SA Succursale France Rue Lavoisier Technopôle Forbach-Sud Forbach Cedex Téléphone +33 (0) Télécopieur +33 (0) Huba Control AG Vestiging Nederland Hamseweg 20A 3828 AD Hoogland Telefoon +31 (0) Telefax +31 (0) Huba Control AG Branch Office United ingdom Unit 13 Berkshire House County Park Business Centre Shrivenham Road Swindon - Wiltshire SN1 2NR Phone +44 (0) Fax +44 (0) [email protected] 9/9
Flow sensor type 210 for liquid media
Flow sensor type 0 for liquid media Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the ármán vortex trail principle.
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
OEM Relative and differential pressure switch type 605
OEM Relative and differential pressure switch type 605 Pressure range 20... 400 Pa Type 605 pressure switches are specially developed for use in gas fired heating systems. There are more than 10 million
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Product Catalogue. AP Automatyka +48 67 357 10 80 [email protected] www.apautomatyka.pl ISO 16949 ISO 14001 OHSAS 18001 ISO 9001.
Product Catalogue ISO 16949 ISO 14001 OHSAS 18001 ISO 9001 Marine Division Since 1945 your qualified partner 1945 Huba Control AG founded 1974 Taken over by Stäfa Control System AG 1990 Concentration
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011
Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...
B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Series description: Wilo-Yonos MAXO-D
ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
Line-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Catalogue Wilo- Stratos PARA
Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Capteur température et humidité pour HVAC
Capteur température et humidité pour HVAC oct-13 Type R 590 Type R 591 Cable Pvc / Pvc Cable Silicone / Silicone Sonde de température Pt100, Pt1000, Ni1000, KTY, NTC, autres sur demande Classe B ou A Raccordement
Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
DSE5J 83 280/112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05)
83 280/112 ED DSE5J DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO 4401-05 (CETOP 05) p max 320 bar Q max 180 l/min MOUNTING SURFACE OPERATING
RoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
maxon sensor maxon sensor
Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,
Operating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
Rotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
GRUNDFOS DIRECT SENSORS Flow Measurement
GRUNDFOS DIRECT SENSORS Flow Measurement Application Specification Functionality Validation Options I II III IV V Direct Sensors VFS 1-20, 2-40, 5-100 I. Application The Vortex Flow Sensors are combined
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05
D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05 GENERAL SECTION PAGE MOOG SERVO- AND PROPORTIONAL CONTROL VALVES General 2 enefits and Functionality 3 General
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
AMTRON E-30 Compact heat and cooling meter
AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution